BrandFangyuan Scientific Instruments
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelFY2700-00
Detection Limitsα: 3–10 MeV
β0–5 MeV
StabilityCount rate drift < 0.2% over 24 h
Resolution0.01 (channel width in keV per channel, typical for digital pulse-height analysis)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFangyuan Scientific Instruments
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelFYYDHN
PriceUSD 28,000 (FOB)
Cooling PrincipleStirling-cycle cryocooler coupled with nitrogen vapor recondensation
Nominal LN₂ Capacity30 L
Cold Finger CompatibilityØ31.5–33 mm
LN₂ Consumption<2 L/day (standby, no detector installed)
Acoustic Noise<60 dB(A) at 1 m
Cooling Power160 W (typ.), 240 W (max.)
Total System Power Draw<400 W
Input Voltage85–264 VAC, 47–63 Hz
Dimensions (Ø × H)460 × 680 mm
Weight55 kg (dry, without LN₂ or detector)
Operating Temperature5–35 °C (optimal ≤25 °C)
Operating Humidity10–80% RH (non-condensing)
Display5-inch capacitive touchscreen
Data InterfaceUSB 2.0 (Type-A to Type-B), .NET-based PC software
SafetyDual pressure-relief valves, liquid level & temperature alarms
ComplianceGB/T 43535-2023 “High-Purity Germanium Gamma Spectrometers”
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFangyuan Scientific Instruments
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic
ModelFY3104-00
Instrument TypeLaboratory Alpha Spectrometer
Measurement MediumSolid Samples
Detector InterfaceCompatible with Commercial PIPS Detectors (International & Domestic)
Radiation TypeAlpha Particles
Sensitivity0.01 cpm (counts per minute) in 3–10 MeV range
Energy Range3–10 MeV
Background Count Rate<1 count/hour (3–10 MeV)
Energy ResolutionFWHM ≤18 keV at 5.486 MeV (with 300 mm² PIPS detector, source-to-detector distance = detector diameter)
Multichannel Scaling512 / 1024 / 2048 / 4096 channels (software-selectable)
Bias Voltage0–180 V (digital, 0.2 V resolution)
Leakage Current Monitoring–3 to +150 nA (accuracy <1 nA)
Vacuum ControlAdjustable vacuum hold, pump-down, and vent modes
Sample ChamberRecoil suppression design
Sample StageManually adjustable vertical positioning (4 mm resolution)
Detector Active Area300–1200 mm²
Operating Temperature0–40 °C
Relative Humidity10–80 % RH
Communication InterfacesUSB, RS-232, Ethernet, Wi-Fi
SoftwareAlphaSense — spectral acquisition, energy/efficiency calibration, nuclide library (built-in + user-defined), peak deconvolution, and GLP-compliant data logging