Hydrogen Air Integrated Generator
Filter
Showing all 5 results
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | RACK-PG Plus |
| Purity | 99.9996% (standard), 99.99996% (optional) |
| Max Flow | 100–600 mL/min |
| Max Pressure | 11 bar (160 psig) |
| Pressure Accuracy | ±0.1 bar (±5%) |
| Gas Volume in System | <50 mL |
| Water Resistivity Requirement | ≥1 MΩ·cm (recommended ≥5 MΩ·cm) |
| Power Consumption | 65–250 W |
| Noise Level | ≤46 dB(A) |
| Dimensions | 19″ rack-mount (483 × 500 × 350 mm, H×W×D) |
| Weight | 17–19 kg |
| Certifications | CE, CSA, FCC |
| Operating Environment | 15–40 °C, 0–80% RH (non-condensing) |
| Display | 128×64-pixel LCD with tactile buttons |
| Gas Outlet | 1/8″ Swagelock |
| Brand | Hailong |
|---|---|
| Origin | Shanghai, China |
| Model | HLHA-500II |
| Hydrogen Purity | 99.999% |
| Hydrogen Flow Rate | 0–500 mL/min |
| Hydrogen Output Pressure | 0–0.4 MPa (factory-set at 0.3 MPa) |
| Air Flow Rate | 0–5000 mL/min |
| Air Output Pressure | 0–0.5 MPa |
| Air Hydrocarbon Content (Output) | <0.1 ppm |
| Max Input Air Hydrocarbon Content | <100 ppm |
| Pressure Stability (H₂) | <0.0001 MPa |
| Max Power Consumption | 350 W |
| Operating Temperature | 0–40 °C |
| Operating Humidity | <85% RH |
| Electrolyte Type | Aqueous KOH |
| Compressor | Domestic Diaphragm-Type |
| Warranty | 1-year system warranty, 3-year electrolyzer warranty |
| Brand | Parker |
|---|---|
| Origin | USA |
| Model | FID-2500 |
| Output Purity | 99.9995% H₂ |
| Zero Air THC | <0.1 ppm |
| Capacity | Supports up to 11 FID detectors |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions | 483 × 584 × 356 mm (W × D × H) |
| Weight | 42 kg |
| Compliance | CE, UL 61010-1, ISO 8573-1 Class 1 for compressed air feed |
| Brand | Ruinen Instrument |
|---|---|
| Model | RNHA-300 |
| Output Flow | H₂ 0–300 mL/min, Air 0–3000 mL/min |
| Purity | H₂ >99.999% |
| Output Pressure | 0–0.4 MPa |
| Pressure Stability | <0.2% |
| H₂ Reservoir Volume | 3 L |
| Feed Water Resistivity | ≥1 MΩ·cm |
| Air Noise Level | <35 dB(A) |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Operating Temperature | 0–40 °C |
| Operating Humidity | <85% RH |
| Brand | Zhonghui Pu |
|---|---|
| Model | HA6800 |
| Output H₂ Flow | 0–300/500 mL/min |
| H₂ Purity | 99.999% |
| H₂ Output Pressure | 0.4 MPa (4 bar) |
| H₂ Pressure Stability | < 0.001 MPa |
| Zero Air Flow | 0–1.5/3/5 L/min |
| Hydrocarbon Content in Zero Air | < 20 ppb |
| Zero Air Particle Filtration | < 0.01 µm |
| Zero Air Dew Point | −10 °C |
| Operating Ambient | 5–40 °C, ≤85% RH |
| Max Power Consumption | 900 W |
| Input Voltage | 220 V ±10% |
| Dimensions (L×W×H) | 600 × 430 × 355 mm |
| Net Weight | ~45 kg |