Hyperspectral Imaging Instrument
Filter
Showing 1–30 of 61 results
| Brand | ABB |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MR-i |
| Price | USD 2,000,000 |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | CS2000 |
| Luminance Range | 0.003–300 cd/m² |
| Contrast Ratio Measurement Capability | Up to 100,000:1 |
| Spectral Bandwidth (FWHM) | 5 nm |
| Polarization Error | ≤2% (at 1° field of view) |
| Measurement Angles | 1°, 0.2°, 0.1° |
| Minimum Measurable Spot Size | Ø0.1 mm (with close-up lens) |
| Measurement Time at 1 cd/m² (Fast Mode) | ~5 s |
| Warm-up Time | 30 s |
| Operating Temperature | 5–35 °C |
| Compliance | JIS Z 8724-1997, CIE 122-1996 |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | AFX1000-IR |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Deployment Mode | Ground-based & UAV-mounted |
| Spectral Range | 400–1000 nm (HSI) + 8–14 µm (LWIR) |
| Thermal Imaging Resolution | 640 × 512 pixels (full-frame radiometric temperature mapping) |
| Frame Acquisition Rate | ≥300 Hz (full spectral cube acquisition) |
| Total Field of View (TFOV) | 30.5° |
| Instantaneous Field of View (IFOV) | 2.7 mrad |
| RGB Camera | 26 MP synchronized capture |
| System Mass | <2.5 kg |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AFX1700-IR |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Platform Compatibility | Ground-based and UAV-mounted |
| Spectral Range | 900–1700 nm (VNIR/SWIR HSI) + 8–14 µm (LWIR thermal) |
| Thermal Spatial Resolution | 640 × 512 pixels (full-frame radiometric temperature mapping) |
| Maximum Data Acquisition Rate | ≥500 Hz across full spectral bands |
| Total Field of View (TFOV) | 35.5° |
| Instantaneous Field of View (IFOV) | 3.5 mrad |
| RGB Camera Resolution | 26 MP |
| System Mass | <2.5 kg |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Hyper-Cam |
| Pricing | Available Upon Request |
| Operating Principle | Fourier Transform Infrared (FTIR) Spectroscopy |
| Imaging Architecture | Dispersive (Grating-Based) |
| Deployment Mode | Ground-Based & Airborne Compatible |
| Spectral Range | 7.7–12.5 µm (MWIR) |
| Spectral Resolution | Up to 0.25 cm⁻¹ |
| Spatial Resolution (IFOV) | 0.45 mrad (typical, lens-dependent) |
| Detector Format | 320 × 256 HgCdTe FPA |
| Field of View (TFOV) | 6.4° × 5.1° |
| Frame Rate | Up to 60 Hz (full-frame, binning-dependent) |
| Calibration | Onboard Blackbody + Ambient Reference |
| Compliance | ISO/IEC 17025-aligned calibration traceability, GLP-compliant data acquisition workflow |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | X20P-IR |
| Spectral Range | 350–1000 nm (VNIR) + 7.5–13.5 µm (LWIR) |
| Spectral Resolution | 164 bands (VNIR), 640 × 512 pixels (LWIR) |
| Spatial Resolution | 1886 × 1886 pixels per hyperspectral cube |
| Frame Rate | 2 cubes/s |
| Field of View (TFOV) | 35° |
| Instantaneous Field of View (IFOV) | < 1.5 mrad (typ.) |
| Imaging Modality | Snapshot-based dispersive hyperspectral imaging with concurrent uncooled microbolometer LWIR imaging |
| Platform Compatibility | Ground-based tripod mounting and UAV-integrated operation (multirotor & fixed-wing) |
| Integrated Stabilization | Brushless gimbal with SkyPort digital interface |
| Onboard Storage | Embedded solid-state storage |
| Data Synchronization | Hardware-triggered, frame-locked VNIR/LWIR acquisition |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Model | X20P-LIR |
| Spectral Range | 350–1000 nm (VIS-NIR) + 905 nm (LiDAR) + 7.5–13.5 µm (MWIR/LWIR) |
| Spectral Resolution | ≥2 cubes/s (1886 × 1886 pixels per cube) |
| Spatial Resolution (IFOV) | ≤0.008° |
| Field of View (TFOV) | 0.008° |
| Frame Rate | ≥2 hyperspectral cubes per second |
| Image Format | 1886 × 1886 pixels per spectral cube |
| Thermal Imaging | 640 × 512 uncooled microbolometer, radiometrically calibrated |
| LiDAR Range | 450 m (@80% reflectivity) |
| Platform Compatibility | UAV-mounted (ground & airborne operation) |
| Onboard Systems | Integrated IMU, real-time georeferencing engine, solid-state storage, embedded control unit |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Model | X20P-LV |
| Spectral Range | 350–1000 nm (hyperspectral) + 905 nm (LiDAR) |
| Spatial Resolution | 1886 × 1886 pixels per hyperspectral cube |
| Frame Rate | 2 cubes/s |
| Spectral Channels | 164 (expandable) |
| LiDAR Range | 450 m (@ 80% reflectivity) |
| LiDAR Accuracy | ±2 cm (1σ @ 20 m) |
| FOV | 0.008° |
| IFOV | 2 cubes/s, 1886 × 1886 pixels/cube |
| IMU Accuracy | Heading ±0.038°, Attitude ±0.008° |
| Data Interface | 2× GigE, 2× USB, HDMI |
| Onboard Storage | 256 GB SSD + 8 GB RAM |
| Sensor Configuration | 20 MP hyperspectral CMOS + 3.5 MP panchromatic sensor + solid-state 905 nm LiDAR |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | AISA Eagle, AISA Hawk, AISA Dual |
| Spectral Range | 400–970 nm (Eagle), 970–2450 nm (Hawk), 400–2450 nm (Dual) |
| Spatial Pixels | 512 or 1024 (Eagle), 320 (Hawk and Dual) |
| Spectral Bands | 488 (Eagle), 256 (Hawk), 500 (Dual) |
| Frame Rate | 160 Hz (Eagle), 100 Hz (Hawk and Dual) |
| Weight | < 12 kg (system total) |
| Integration | GPS/INS-aided georeferencing module included |
| Data Acquisition | Real-time onboard storage with lossless compression |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model Series | Kymera 193i, Kymera 328i, Shamrock 500i, Shamrock 750, Mechelle 5000 |
| Spectral Resolution | 0.02 nm (Shamrock 750) |
| Imaging Resolution | 6000 (Mechelle 5000) |
| Optical Design | Czerny-Turner or Echelle |
| Configuration | Filter-based spectroscopy |
| Platform Compatibility | Ground- and airborne deployment |
| Detector Interface | Dual-input/dual-output architecture |
| Focal Length Range | 193 mm to 750 mm |
| Aperture Range | f/3.6 to f/9.7 |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | Mechelle 5000 |
| Spectral Range | 200–975 nm |
| Optical Architecture | Fixed, pre-aligned echelle spectrograph with no moving parts |
| Detector Format | Integrated CCD or sCMOS detector (user-selectable) |
| Resolution | High-resolution echelle dispersion (R ≈ 20,000–40,000 depending on slit and detector configuration) |
| Wavelength Coverage | Simultaneous full-range acquisition without scanning |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | Shamrock 163i |
| Focal Length | 163 mm |
| f-number | f/3.6 |
| Optical Design | Czerny-Turner |
| Grating Compatibility | Interchangeable ruled and holographic gratings |
| Input Options | Adjustable slit (10–200 µm), fiber optic coupling (SMA905, FC/PC), free-space input |
| Detector Interface | Standard Andor camera mounting (C-mount, F-mount, or direct sensor integration) |
| Wavelength Range | UV-Vis-NIR (dependent on grating and detector choice) |
| Resolution | <0.1 nm (typical, with 1200 grooves/mm grating and 10 µm slit) |
| Stray Light Rejection | <1×10⁻⁴ |
| Brand | Anyty |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | 3R-PPSC410 |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 5 nm |
| Spatial Resolution | 1920 × 1920 pixels |
| Total Field of View (TFOV) | 25° |
| Platform Compatibility | Ground-based and UAV-mounted operation |
| Working Principle | Push-broom hyperspectral imaging with integrated CMOS sensor and transmission grating spectrometer |
| Brand | Anyty |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | 3R-PPSC417 |
| Pricing | Upon Request |
| Operating Principle | Reflectance-Based Hyperspectral Imaging |
| Deployment Modes | Ground-Based & Airborne (UAV-Compatible) |
| Spectral Range | 390–1710 nm |
| Spectral Resolution | 18 nm |
| Spatial Resolution | 640 × 640 pixels |
| Total Field of View (TFOV) | 25° |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | SS-120 |
| Spectral Range | 635–1100 nm |
| Spectral Sampling Interval | 1.0 nm |
| Spectral Resolution | 3.0 nm |
| Spectral Accuracy | ±0.5 nm |
| Spectral Repeatability | ±0.2 nm |
| A/D Conversion | 14-bit |
| Signal-to-Noise Ratio | 1500:1 |
| Stray Light | ≤0.25% at 850 nm |
| Noise Level | ≤3 counts |
| Integration Time | 10 ms – 10 s |
| Linearity | <1% or 0.5% |
| Quantum Efficiency | >10% (λ < 1030 nm) |
| Radiometric Repeatability | <1% (λ < 1020 nm) |
| Cosine Response Error | ±5% at 75° zenith angle |
| Field of View | 25° or 150° (downward-facing configuration) |
| Operating Temperature | −20 to +70 °C |
| Relative Humidity | 0–100% RH |
| Power Consumption | 1 W (USB-powered) |
| Current Draw | 190 mA |
| Weight | 300 g |
| Dimensions | 89.3 × 50.8 × 38.1 mm (H × W × L) |
| Communication Interface | USB |
| Software Compatibility | Windows XP and later |
| Irradiance Calibration Uncertainty | ±5% |
| Temperature Coefficient | −0.1 ± 0.1 %/°C |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | ArtScanner |
| Pricing | Available Upon Request |
| Brand | ASD |
|---|---|
| Origin | United Kingdom |
| Distributor Type | Authorized General Distributor |
| Import Status | Imported |
| Model | FSA (FieldSpec Assistant) Smart Handle |
| Pricing | Available Upon Request |
| Brand | AZUP |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | AZ-UX20 |
| Operating Principle | Snapshot (Snapshot Fourier-transform–free, lenslet-based light-field hyperspectral imaging) |
| Imaging Mode | Dispersive (prism-grating hybrid dispersion with tiled detector architecture) |
| Deployment | Ground-based and UAV-mounted |
| Spectral Range | 350–1000 nm |
| Spectral Sampling Interval | 4 nm |
| Spectral Resolution | 8 nm @ 532 nm |
| Number of Spectral Bands | 164 (expandable) |
| Spatial Resolution (IFOV) | >3.5 MP × 2 CMOS/CCD sensor array |
| Field of View (TFOV) | 35° |
| Frame Rate | 5 hyperspectral data cubes per second |
| Radiometric Resolution | 12-bit digitization |
| Integration Time | 0.1–1000 ms |
| Data Interface | Dual Gigabit Ethernet |
| Geotagging | GPS/BeiDou coordinate triggering supported |
| Weight | ≤600 g |
| Operating Temperature | 0–40 °C |
| Calibration Support | Reflectance calibration with 30 cm × 30 cm diffuse white reference panel |
| Brand | Batop |
|---|---|
| Origin | Germany |
| Model | TDS10XX |
| Spectral Range | 0.05–4 THz (laser-dependent) |
| Spectral Resolution | 2 GHz (equivalent to ~0.025 cm⁻¹) |
| Imaging Resolution | 1280 × 1024 pixels |
| Field of View (TFOV) | 8° |
| Instantaneous Field of View (IFOV) | 0.18 mrad |
| Frame Rate | 15 fps |
| Beam Diameter | 22 mm (collimated), 1 mm @ 1 THz (focused) |
| Sample Size Support | up to 30 × 30 mm (collimated), ≥5 × 5 mm (focused) |
| Dynamic Range | >65–75 dB |
| Scan Range | 500–650 ps |
| THz Pulse Repetition Rate | 1–30 kHz (10 kHz default) |
| Bias Voltage for PCA Emitter | 10 V |
| Operating Mode | Free-space or fiber-coupled (1550 nm / 1060 nm options) |
| Environmental Compatibility | N₂-purged sample chamber |
| Brand | BaySpec |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | OCI-M |
| Operating Principle | Pushbroom Scanning |
| Imaging Modality | 3D Hyperspectral Data Cube Acquisition |
| Deployment Platform | Ground-based and Airborne Compatible |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 5 nm (FWHM) |
| Spatial Resolution | 1000 pixels across track × L pixels along track |
| Total Field of View (TFOV) | 18° |
| Frame Rate | 120 fps |
| Interface | USB 3.0 |
| Dimensions | 30 mm × 30 mm × 75 mm |
| Weight | 117 g |
| Real-time Preview | Yes |
| Scan Time per Cube | ≤5 s |
| Data Cube Generation Time | ≤10 s |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Sichuan, China |
| Model | GaiaField Pro |
| Spectral Range | 400–2500 nm (configurable by variant) |
| Spectral Resolution | 2.8–10 nm |
| Spatial Resolution | Up to 640 × 700 pixels (spatial × spectral) |
| FOV | 18°–24° (lens-dependent) |
| IFOV | ≤ 0.5 mrad (with standard 23–30 mm lenses) |
| Frame Rate | 4–8 s per hyperspectral cube |
| Detector Types | CCD, InGaAs, T2SL |
| Dynamic Range | 12–14 bits |
| Interface | USB 3.0 / GigE / USB 2.0 |
| Weight | 3–8.5 kg |
| Integrated Battery | 80–120 Wh (≥2 h operation) |
| Onboard Processing | ARM-based real-time analysis engine |
| Wireless Control | Wi-Fi (Android/iOS/iPadOS) |
| Data Output Format | ENVI-compatible .hdr/.bil, Evince, SpecSight-ready |
| Calibration | Radiometric, reflectance, flat-field, lens distortion, and non-uniformity correction |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | GaiaField-ImgFluo |
| Spectral Range | 670–780 nm (extendable to 650–800 nm) |
| Spectral Resolution | 0.3–0.4 nm |
| Spectral Sampling Interval | 0.1 nm |
| Number of Spectral Bands | 100–1000 |
| Peak SNR | >1000:1 |
| Slit Width | 30 µm |
| Lens | 25 mm Fixed-Focal-Length |
| Spatial Resolution | ≥1200 × 1000 pixels |
| Frame Rate | 1–100 fps |
| Interface | USB 3.0 |
| Weight | <2.27 kg |
| Imaging Mode | Push-broom |
| Deployment Platform | Ground-based (tripod-mounted or vehicle-integrated), compatible with UAV integration via optional gimbal and power interface |
| Cooling | Thermoelectrically cooled or uncooled sCMOS sensor |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Beijing, China |
| Model | GaiaMicro-G |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 3.5 nm |
| Imaging Principle | Push-broom scanning |
| Optical Configuration | Transmission (visible–NIR) and semi-reflective (NIR) |
| Detector Type | CCD/SCMOS/InGaAs |
| Spatial Scanning | Motorized XY precision translation stage |
| Numerical Aperture | F/2.8 (GaiaMicro-G-V10-LU) |
| Slit Size | 30 µm × 9.6 mm |
| Pixel Array | 1392 × 1040 (spatial × spectral) |
| Spectral Channels | 256 (240 effective) |
| Data Depth | 14-bit |
| Interface | USB 2.0 |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GaiaSorter |
| Price | USD 21,000 (FOB) |
| Operating Principle | Push-broom Hyperspectral Imaging |
| Imaging Mode | 3D Data Cube Acquisition |
| Deployment | Benchtop & Airborne-Compatible |
| Spectral Range | 350–2500 nm (configurable bands: 400–1000 nm, 900–1700 nm, 1000–2500 nm) |
| Spectral Resolution | ≤2.8 nm (FWHM) |
| Spatial Resolution (IFOV) | 30 µm / 50 µm (selectable via optics) |
| Detector Resolution | 1392 × 1040 pixels |
| Field of View (TFOV) | 20° |
| Frame Rate | 25–120 fps |
| Illumination Uniformity | ≥90% |
| Sample Chamber Max Dimensions | 300 × 300 × 200 mm |
| Working Distance Adjustment Range | 180–600 mm (dependent on sample height) |
| Power Input | AC 220 V ±10% |
| Light Source | DC 12 V adjustable-intensity uniform LED array (~200 W total) |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Model | GaiaField |
| Operating Principle | Push-broom |
| Imaging Mode | 3D spatial-spectral data cube |
| Deployment | Ground-based |
| Spectral Range | 400–1000 nm (visible to near-infrared) |
| Spectral Resolution | <3 nm (VIS), ≤5 nm (NIR) |
| Spatial Resolution (IFOV) | Configurable via interchangeable lenses |
| Field of View (TFOV) | Lens-dependent |
| Frame Rate | Up to 120 fps (at full resolution, system-limited) |
| Battery Life | >4 hours continuous operation |
| Environmental Rating | IP5X dust resistant, IP1X water resistant |
| Interface | USB 3.0 |
| Data Format | ENVI-compatible BIL/BIP, TIFF, and raw binary |
| OS Compatibility | Windows 7/8/10 (32- & 64-bit) |
| Calibration | Radiometric, reflectance, flat-field, lens distortion, and non-uniformity correction |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Sichuan, China |
| Model | GaiaMicro-G |
| Spectral Range | 400–1000 nm (Visible-NIR) / 900–1700 nm (NIR) |
| Spectral Resolution | 2.8–5.0 nm |
| Spatial Resolution | Configurable via interchangeable infinity-corrected objectives (5×–100×) |
| Numerical Aperture | F/2.0–F/2.8 |
| Detector | CCD / sCMOS / InGaAs |
| Pixel Array | Up to 2048 × 2048 (spatial × spectral) |
| Bit Depth | 14–16 bits |
| Interface | USB 2.0 / USB 3.0 / GigE |
| Imaging Mode | Push-broom scanning with motorized XY stage |
| FOV & IFOV | Objective-dependent (e.g., 10× objective: ~1.0 mm FOV, ~0.5 µm IFOV at diffraction limit) |
| Frame Rate | Variable (up to 60 fps for snapshot LCTF variants |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Sichuan, China |
| Model | GaiaSky-mini2-VN |
| Imaging Principle | Push-broom scanning |
| Platform Compatibility | Rotary-wing UAVs (e.g., DJI M600 Pro, S1000+), airships, helicopters |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 3.5 nm (at 30 µm slit width) |
| Numerical Aperture | f/2.8 |
| Sensor | Sony ICX674 CCD |
| Pixel Pitch | 4.54 µm |
| Output Bit Depth | 14-bit |
| Interface | USB 3.0 |
| Operating Voltage | 12–19 V DC |
| Power Consumption | 45 W |
| Image Resolution | 960 × 1040 pixels |
| Spatial Sampling (IFOV) | 0.16 m @ 300 m AGL, 17 mm lens |
| Horizontal FOV | 28.7° (@17 mm), 26.7° (@18.5 mm), 21.5° (@23 mm) |
| Ground Coverage Width | 154 m (@17 mm, 300 m) |
| Scan Rate | 160 line images/s |
| Weight | 1.5 kg (integrated camera + controller) |
| Storage | 240 GB SSD |
| Mounting Envelope | ≥330 × 200 × 260 mm (H×W×D) |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GaiaSorter-Dual |
| Spectral Range | 350–2500 nm |
| Spectral Resolution | 2.8 nm |
| Spatial Resolution (IFOV) | 30 µm and 50 µm |
| Field of View (TFOV) | 20° |
| Imaging Resolution | 1392 × 1040 pixels |
| Frame Rate | 25–120 fps |
| Imaging Modality | 3D Scanning |
| Operational Mode | Airborne-Compatible Benchtop Configuration |
| Power Input | AC 220 V ±10% / DC 12 V |
| Total System Power Consumption | ~500 W |
| Sample Chamber Max Dimensions | 300 × 300 × 100 mm |
| Working Distance Adjustment Range | 100–600 mm |
| Scan Travel | 800 mm |
| Output Interfaces | USB, Ethernet, RS-232 |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Sichuan, China |
| Model | GaiaTracer |
| Imaging Modality | Hyperspectral (Push-broom & Tunable Filter variants) |
| Deployment | Benchtop Laboratory |
| Spectral Range | 250–2500 nm (configurable by variant) |
| Spectral Resolution | 8–20 nm (FWHM, wavelength-dependent) |
| Spatial Resolution | ≤100 µm at 300 mm working distance |
| Field of View (TFOV) | ±7° |
| Instantaneous Field of View (IFOV) | <0.1 mrad |
| Frame Rate | 22–25 fps (GigE data interface) |
| Optical Interface | USB 2.0 (control), GigE (image data) |
| Illumination | Dual 300 W adjustable broadband source (VIS–SWIR), UV optional |
| Sample Stage | Motorized Z-axis (0–800 mm), X/Y translation (300 mm travel), tilt/height-adjustable line source |
| Compliance | Designed for ISO/IEC 17025-aligned forensic laboratories |
| Software | Proprietary acquisition & spectral unmixing suite with spectral library matching and PCA-based anomaly detection |