Impedance Analyzer
Filter
Showing all 6 results
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | MTIA |
| Instrument Type | Mid-Frequency Impedance Analyzer |
| Frequency Range | 0.05 Hz – 10 MHz |
| Frequency Resolution | 0.05% of set frequency |
| Basic Measurement Accuracy | ±0.05% |
| Impedance Range | 20 mΩ – 1 GΩ |
| Measurement Speed | 10,000 samples/s |
| Measurement Modes | Four-Terminal (Kelvin), Multi-Channel (up to 128 channels) |
| Excitation Voltage Range | 0.02 V – 2.0 V (10 mV resolution) |
| Compensation Methods | Open-Short-Load, Open-Load, Short-Load, Load-only |
| Supported Parameters | Z, θ, R, X, Ls/Lp, Cs/Cp, D, Q, Y, G, B |
| Equivalent Circuit Modeling | Yes |
| Data Visualization | Sweep plots, multi-channel mapping, time-series traces |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | MTIA-8 |
| Instrument Type | Medium-Frequency Impedance Analyzer |
| Frequency Range | 0.01 Hz – 10 MHz |
| Frequency Resolution | 0.05 Hz |
| Basic Measurement Accuracy | ±0.05% |
| Impedance Range | 20 mΩ – 1 GΩ |
| Measurement Speed | 10,000 samples per second |
| Channel Capacity | Up to 128 parallel measurement channels (hardware-expandable) |
| Measurement Modes | Four-Terminal (Kelvin), Multi-Channel Synchronized Acquisition |
| Excitation Voltage Range | 0.02 V – 2.0 V (10 mV resolution) |
| Compensation Methods | Open-Short-Load, Open-Load, Short-Load, Load-only |
| Supported Parameters | Z, θ, R, X, Ls/Lp, Cs/Cp, D, Q, Y, G, B, Rs, Rp |
| Equivalent Circuit Fitting | Up to 7-element models (e.g., R-C, R-L-C, R-(C//R), etc.) |
| Brand | Novocontrol Technologies |
|---|---|
| Origin | Germany |
| Model | Alpha-A |
| Frequency Range | 3 µHz – 40 MHz (up to 3 GHz with Keysight E4991B RF Impedance Analyzer) |
| Temperature Range | −160 °C to +1600 °C |
| Impedance Range | 10 mΩ to 100 TΩ |
| Measurement Voltage | 10⁻⁶ V to 3 V RMS |
| DC Bias Voltage | ±40 V |
| Sample Compatibility | Solids, thin films, liquids, powders, ceramics, polymers, electrolytes |
| Software | Novocontrol WinDETA v5.x with real-time multi-parameter acquisition (≥30 parameters), audit trail, GLP-compliant reporting |
| Brand | Novocontrol Technologies |
|---|---|
| Origin | Germany |
| Model | Alpha-A |
| Frequency Range | 3 µHz – 40 MHz (up to 3 GHz with Keysight E4991B RF Impedance Analyzer) |
| Temperature Range | −160 °C to +1600 °C |
| Impedance Range | 10 mΩ to 100 TΩ |
| AC Voltage Range | 10⁻⁶ V to 3 V RMS |
| DC Bias Voltage | ±40 V |
| Compliance | ASTM D150, ISO 257-1/2, IEC 60250, USP <1058>, FDA 21 CFR Part 11 (software-enabled audit trail) |
| Brand | Novocontrol Technologies |
|---|---|
| Origin | Germany |
| Model | MKW4200 |
| Frequency Range | 3 µHz – 40 MHz (up to 3 GHz with Keysight E4991B) |
| Temperature Range | −160 °C to +1600 °C |
| Impedance Range | 10 mΩ to 100 TΩ |
| AC Voltage Range | 10⁻⁶ V to 3 V |
| DC Bias Voltage | ±40 V |
| Sample Compatibility | Solids, thin films, liquids, powders, pastes |
| Compliance | ASTM D150, ISO 257-3, IEC 60250, USP <1058>, FDA 21 CFR Part 11 (software audit trail enabled) |
| Brand | ROOKO |
|---|---|
| Model | FT-305 |
| Origin | Zhejiang, China |
| Impedance Range | 10³–10¹⁷ Ω |
| Test Voltage | 0–1000 V (adjustable) |
| Accuracy | ±1% for <1 GΩ, ±20% for ≥10 TΩ |
| Power Consumption | 5 W |
| Interface | USB + RS-232 |
| Operation Modes | Local LCD/Keypad & PC Software Control |
| Compliance | Designed for ASTM D257, IEC 62631-3-1, GB/T 1410 |