Incubator Equipment
Filter
Showing 31–60 of 419 results
| Brand | AnYuJie |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HWS-150B |
| Heating Method | Air-Jacketed Heating |
| Cooling Method | Compressor-Based Refrigeration |
| Humidification System | External Water Reservoir with Ultrasonic Humidifier |
| Temperature Range (with Humidification) | 5–50 °C |
| Temperature Range (without Humidification) | 5–50 °C |
| Temperature Fluctuation | ±1 °C |
| Temperature Uniformity | ±1 °C |
| Humidity Range | 40–95 %RH |
| Humidity Accuracy | ±5 %RH |
| Chamber Capacity | 150 L |
| External Dimensions (W×D×H) | 600 × 640 × 1340 mm |
| Brand | AnYuJie |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HWS-2000 |
| Heating Method | Air-Jacketed (Forced-Air) |
| Cooling Method | Hermetic Compressor-Based Refrigeration |
| Humidification System | External Water Reservoir with Ultrasonic Humidifier |
| Temperature Range (with Humidification) | 5–50 °C |
| Temperature Range (without Humidification) | 5–50 °C |
| Temperature Fluctuation | ±1 °C |
| Temperature Uniformity | ±1 °C |
| Humidity Range | 40–95 %RH |
| Humidity Accuracy | ±5 %RH |
| Chamber Capacity | 2000 L |
| External Dimensions (W×D×H) | 2400 × 760 × 1880 mm |
| Brand | AnYuJie |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HWS-250B |
| Heating Method | Air-jacketed |
| Cooling Method | Compressor-based refrigeration |
| Humidification System | External water reservoir |
| Temperature Range (with humidification) | 5–50°C |
| Temperature Range (without humidification) | 5–50°C |
| Temperature Fluctuation | ±1°C |
| Temperature Uniformity | ±1°C |
| Humidity Range | 40–95% RH |
| Humidity Accuracy | ±5% RH |
| Chamber Capacity | 250 L |
| External Dimensions (W×D×H) | 600 × 640 × 1340 mm |
| Brand | AnYuJie |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HWS-350B |
| Heating Method | Air-jacketed Heating |
| Cooling Method | Compressor-based Refrigeration |
| Humidification System | External Water Reservoir with Ultrasonic Humidifier |
| Temperature Range (with Humidification) | 5–50 °C |
| Temperature Range (without Humidification) | 5–50 °C |
| Temperature Fluctuation | ±1 °C |
| Temperature Uniformity | ±1 °C |
| Humidity Range | 40–95 %RH |
| Humidity Accuracy | ±5 %RH |
| Chamber Capacity | 350 L |
| External Dimensions (W×D×H) | 730 × 740 × 1690 mm |
| Brand | AnYuJie |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HWS-450 |
| Heating Method | Air-Jacketed Heating |
| Cooling Method | Compressor-Based Refrigeration |
| Humidification Water Tank | External Reservoir |
| Temperature Range (with Humidification) | 5–50 °C |
| Temperature Range (without Humidification) | 5–50 °C |
| Temperature Fluctuation | ±1 °C |
| Temperature Uniformity | ±1 °C |
| Humidity Range | 40–95 %RH |
| Humidity Accuracy | ±5 %RH |
| Chamber Capacity | 450 L |
| External Dimensions (W×D×H) | 640 × 640 × 1850 mm |
| Brand | AnYuJie |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HWS-600 |
| Heating Method | Air-Jacketed |
| Cooling Method | Compressor-Based Refrigeration |
| Humidification Reservoir | External Water Tank |
| Temperature Range (with Humidification) | 5–50 °C |
| Temperature Range (without Humidification) | 5–50 °C |
| Temperature Fluctuation | ±1 °C |
| Temperature Uniformity | ±1 °C |
| Humidity Range | 40–95 %RH |
| Humidity Accuracy | ±5 %RH |
| Chamber Capacity | 600 L |
| External Dimensions (W×D×H) | 1260 × 590 × 1525 mm |
| Brand | AnYuJie |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HWS-70B |
| Price Range | USD 700–1,150 (FOB) |
| Heating Method | Air-Jacketed Heating |
| Cooling Method | Compressor-Based Refrigeration |
| Humidification System | External Water Reservoir with Ultrasonic Humidifier |
| Temperature Range (with Humidification) | 5–50 °C |
| Temperature Range (without Humidification) | 5–50 °C |
| Temperature Fluctuation | ±1 °C |
| Temperature Uniformity | ±1 °C |
| Humidity Range | 40–95 %RH |
| Humidity Accuracy | ±5 %RH |
| Chamber Capacity | 70 L |
| External Dimensions (W×D×H) | 540 × 540 × 1100 mm |
| Brand | ARALAB |
|---|---|
| Model | FitoClima 600 |
| Internal Volume | 600 L |
| Temperature Range | −5 °C to +45 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity | ±1.0 °C (at setpoint) |
| Temperature Fluctuation | ±0.5 °C (1σ) |
| Humidity Range | 20–95% RH |
| Humidity Uniformity | ±2% RH |
| Humidity Fluctuation | ±0.5% RH (1σ) |
| Shelf Dimensions | 630 mm × 510 mm |
| Shelf Load Capacity | 18 kg per shelf |
| Standard Shelves | 4 stainless steel shelves |
| Max. Shelves | 10 |
| Total Standard Shelf Area | 1.33 m² |
| External Dimensions (H×W×D) | 1980 × 745 × 950 mm |
| Net Weight | 175 kg |
| Power Supply | 1/N/PE, 230 V ±10%, 50 Hz, 16 A |
| Water Supply | Deionized or distilled water, 1–5 bar, conductivity <40 μS/cm |
| Brand | ARALAB |
|---|---|
| Model | FitoClima 600 PLH / FitoClima 1200 PLH |
| Temperature Range | 5°C to +45°C (±0.1°C) |
| Humidity Range | 40–90% RH (±0.1% RH) |
| Light Intensity | 0–300 µmol/m²·s (up to 21,500 Lux) |
| Internal Volume | 600 L / 1200 L |
| Illumination Type | White LED or Fluorescent Plant-Growth Lighting |
| Temperature Uniformity | ±1.0°C |
| Humidity Uniformity | ±2% RH |
| Airflow Control | 1–100% adjustable (0.3–1 m/s) |
| Compliance | EN 60068-3-5, IEC 61000-6-3, EMC 2004/108/EC, MD 2006/42/CE, LVD 2006/95/CE, EN 14509-CPR 305/2011/EU, EN 13823:2010+A1:2014 |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | BD 56 / BD 115 / BD 260 / BD 720 |
| External Dimensions (W×H×D, mm) | 560×625×565 / 710×735×605 / 810×965×760 / 1165×1590×870 |
| Internal Dimensions (W×H×D, mm) | 360×420×380 / 510×530×420 / 610×760×545 / 960×1280×600 |
| Internal Volume (L) | 57 / 112 / 253 / 737 |
| Net Weight (kg) | 39 / 54 / 85 / 170 |
| Max. Total Load (kg) | 70 / 150 / 270 / — |
| Max. Load per Shelf (kg) | 30 / 30 / 40 / 40 |
| Temp. Range | Ambient +5 °C to 100 °C |
| Temp. Uniformity (±K @37°C) | 0.3 / 0.3 / 0.3 / 0.7 |
| Temp. Fluctuation (±K @37°C) | 0.1 / 0.1 / 0.2 / 0.1 |
| Heating Time to 37°C (min) | 42 / 55 / 60 / 70 |
| Recovery Time after 30s Door Opening (min @37°C) | 15 / 15 / 16 / 23 |
| Rated Power (230 V, kW) | 0.3 / 0.35 / 0.85 / 1.65 |
| Standard/Max. Shelving | 2/4 / 2/5 / 2/8 / 2/16 |
| Safety Class | Independent Temperature Safety Device Class 3.1 (DIN 12880) with Optical Alarm |
| Interior Door | Tempered Safety Glass (ESG) |
| Control Interface | LCD Display with APT.line™ Technology |
| Ventilation | Mechanical Exhaust Valve |
| Data Logging | USB Interface for Recording |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model(s) | BD115, BD240, BD400 |
| External Dimensions (W×H×D mm) | 435×495×520 (BD115), 1235×1025×765 (BD400) |
| Internal Dimensions (W×H×D mm) | 222×330×277 (BD115), 1000×800×500 (BD400) |
| Internal Volume | 20 L (BD115), 400 L (BD400) |
| Net Weight (empty) | 27 kg (BD115), 135 kg (BD400) |
| Max. Total Load | 25 kg (BD115), 90 kg (BD400) |
| Max. Load per Shelf | 12 kg (BD115), 35 kg (BD400) |
| Temp. Range | Ambient +5 °C to 100 °C |
| Temp. Uniformity (±K @37°C) | 0.5 K |
| Temp. Stability (±K @37°C) | 0.2 K (BD115), 0.1 K (BD400) |
| Heating Time to 37°C | 59 min (BD115), 120 min (BD400) |
| Recovery Time after 30s Door Opening (@37°C) | 20 min (BD115), 10 min (BD400) |
| Rated Power (230 V) | 0.2 kW (BD115), 0.85 kW (BD400) |
| Standard/Max. Shelves | 2/4 (BD115), 2/9 (BD400) |
| Safety Class | Temperature Safety Device Class 3.1 (DIN 12880), Optical Alarm |
| Controller | Time-Programmable, RS 422 Interface |
| Construction | ESG (Tempered Safety Glass) Inner Door, Adjustable Exhaust Valve, Apt.line™ Preheating Chamber Technology, Natural Convection Design |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | BD-S 56 / BD-S 115 |
| External Dimensions (W×H×D) | 560×580×515 mm / 740×790×555 mm |
| Internal Dimensions (W×H×D) | 400×400×350 mm / 550×550×390 mm |
| Internal Volume | 62 L / 118 L |
| Net Weight (empty) | 41 kg / 57 kg |
| Temperature Range | Ambient +5 °C to 70 °C |
| Temperature Uniformity (±K @ 37 °C) | 0.7 / 0.5 |
| Temperature Fluctuation (±K @ 37 °C) | 0.1 / 0.2 |
| Recovery Time (min @ 37 °C, 30 s door opening) | 15 / 15 |
| Power Consumption (Wh/h @ 37 °C) | 25 / 25 |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | BD/BF |
| Temperature Range | +5 °C to 99.9 °C (above ambient) |
| Temperature Accuracy | ±0.1 °C |
| Control System | Microprocessor-based PID controller with LED display |
| Timer Function | 0–99:59 h |
| Safety Device | Class 3.1 temperature safety device (DIN 12880) |
| Communication Interface | RS422 for APT-COM software integration |
| Interior Door | Smooth tempered glass |
| Air Circulation | Forced convection (BF series) |
| Sterilization Capability | Dry-heat decontamination at 99 °C |
| Preconditioning Technology | APT-Line® preheating chamber |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | BF56 / BF115 / BF260 / BF720 |
| External Dimensions (W×H×D, mm) | 560×625×565 / 710×735×605 / 810×965×760 / 1165×1590×870 |
| Internal Dimensions (W×H×D, mm) | 400×440×340 / 550×550×380 / 650×780×510 / 1000×1300×560 |
| Internal Volume (L) | 59 / 114 / 257 / 734 |
| Net Weight (kg) | 39 / 54 / 85 / 165 |
| Max. Total Load (kg) | 70 / 150 / 270 / 120 |
| Max. Load per Shelf (kg) | 30 / 30 / 40 / 40 |
| Temp. Range | Ambient +8 °C to 100 °C (BF56–BF260) |
| Temp. Uniformity (±K @37°C) | 0.2 / 0.3 / 0.2 / 0.3 |
| Temp. Fluctuation (±K @37°C) | 0.1 across all models |
| Time to Reach 37°C (min) | 6 / 8 / 7 / 15 |
| Recovery Time after 30s Door Opening (min @37°C) | 3 / 3 / 3 / 4 |
| Rated Power (230 V, kW) | 0.4 / 0.4 / 0.9 / 1.75 |
| Standard/Max. Shelves | 2/4 / 2/5 / 2/8 / 2/16 |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | BF |
| Internal Volume | 400 L |
| External Dimensions (W×H×D) | 1235 × 1025 × 765 mm |
| Internal Dimensions (W×H×D) | 1000 × 800 × 500 mm |
| Net Weight (empty) | 145 kg |
| Max. Total Load | 90 kg |
| Max. Load per Shelf | 35 kg |
| Temperature Range | Ambient +5 °C to 100 °C |
| Temp. Uniformity (±K @37°C) | 0.4 |
| Temp. Fluctuation (±K @37°C) | 0.1 |
| Heating Time to 37°C | 12 min |
| Recovery Time (30 s door opening @37°C) | 5 min |
| Rated Power (230 V) | 0.85 kW |
| Standard Shelves | 2 (up to 9 optional) |
| Preheating Chamber Technology | ACT.line™ |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | CB |
| Internal Volume (L) | 53 / 170 / 260 |
| Net Weight (kg, empty) | 53 / 98 / 125 |
| Max Total Load (kg) | 30 / 30 / 40 |
| Max Load per Shelf (kg) | 10 / 10 / 10 |
| Rear Wall Clearance (mm) | 100 / 100 / 100 |
| Side Wall Clearance (mm) | 50 / 50 / 50 |
| Internal Dimensions (W×H×D, mm) | 400×400×330 / 560×600×505 / 620×750×575 |
| External Dimensions (W×H×D, mm) | 528×674×545 / 680×870×715 / 740×1020×785 |
| Temp. Range | RT+4–6°C to 60°C |
| Temp. Uniformity (±K @37°C) | 0.3 / 0.3 / 0.4 |
| Temp. Stability (±K @37°C) | 0.1 / 0.1 / 0.13 |
| Humidity Range | 90–95% RH |
| CO₂ Range | 0–20 vol.% |
| CO₂ Measurement Principle | Single-beam IR sensor |
| Recovery Time after 30-sec Door Opening (min @37°C) | 5 / 6 / 6 |
| Rated Power (230 V, kW) | 0.8 / 1.4 / 1.5 |
| Standard/Max Shelf Quantity | 2/3 / 3/6 / 3/8 |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | CB Series |
| Sterilization | Dry-heat sterilization (180 °C, 2–4 h) |
| CO₂ Control Range | 0–20 % (±0.1 % typical accuracy) |
| Temperature Range | Ambient +5 °C to 50 °C (±0.1 °C stability at 37 °C) |
| Humidity Control | Active humidification with integrated water pan and saturation monitoring |
| Chamber Volume Options | 53 L to 216 L |
| Construction | Stainless steel interior (AISI 304), double-wall insulated chamber, HEPA-filtered air circulation (ISO Class 5 compliant) |
| Compliance | IEC 61010-1, EN 61326-1, CE marked for in vitro diagnostic use (IVDR Annex II) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | CB-S Solid.Line |
| Internal Volume (L) | 170 / 267 |
| Net Weight (kg, empty) | 96 / 122 |
| Max. Total Load (kg) | 30 / 40 |
| Max. Load per Shelf (kg) | 10 / 10 |
| Rear Clearance (mm) | 100 / 100 |
| Side Clearance (mm) | 50 / 50 |
| Internal Dimensions – W×H×D (mm) | 560×600×505 / 620×750×575 |
| External Dimensions – W×H×D (mm) | 680×870×715 / 740×1020×785 |
| Temp. Range | Ambient +6 °C to 50 °C |
| Temp. Uniformity (±K @37 °C) | 0.3 / 0.4 |
| Temp. Stability (±K @37 °C) | 0.1 / 0.13 |
| Recovery Time (min @37 °C, 30 s door open) | 6 / 8 |
| Humidity Range | 90–95 % RH |
| CO₂ Range | 0–20 vol.% |
| CO₂ Sensing Principle | Infrared (IR) |
| Rated Power (230 V) | 1.3 kW / 1.5 kW |
| Standard/Max. Shelves | 2 / 6 or 2 / 8 |
| Sterilization | Dry-heat at 180 °C |
| Interface | Ethernet, USB, Dry Contact Alarm Output |
| Data Logging | Internal, USB exportable |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | CBF Series |
| Internal Volume | 170 L / 267 L |
| Net Weight (empty) | 95 kg / 125 kg |
| Max. Total Load | 30 kg / 40 kg |
| Max. Load per Shelf | 10 kg |
| Rear Wall Clearance | 100 mm |
| Side Wall Clearance | 50 mm |
| Internal Dimensions (W×H×D) | 560×600×505 mm / 620×750×575 mm |
| External Dimensions (W×H×D) | 680×870×715 mm / 740×1020×785 mm |
| Temp. Range | RT + 6 °C to 60 °C |
| Temp. Uniformity | ±0.4 K @ 37 °C |
| Temp. Stability | ±0.1 K @ 37 °C |
| Temp. Recovery Time (30 s door open) | 6 min @ 37 °C |
| Humidity Range | 50–95 %RH |
| CO₂ Range | 0–20 vol.% |
| CO₂ Sensing Principle | Single-beam IR |
| Rated Power (230 V) | 1.4 kW / 1.5 kW |
| Standard/Max. Shelves | 3/6 or 3/8 |
| Sterilization | 180 °C dry-heat |
| Chamber Material | Seamless stainless steel with shelf reinforcement system |
| Gas Mixing | Venturi-type CO₂ injection nozzle |
| Control Interface | Touchscreen controller with USB data export, Ethernet, zero-voltage alarm contacts |
| Data Logging | Internal recorder with open-format measurement values |
| Safety Systems | CO₂ Fail-Safe pH monitoring, optical & acoustic fault diagnostics |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KB ECO 240 / KB ECO 400 / KB ECO 720 / KB ECO 1020 |
| Temperature Range | 0–70 °C (up to 28 K below ambient) |
| Temp. Uniformity at 37 °C | ±0.1 K |
| Temp. Stability at 37 °C | ±0.1 K |
| Max. Heat Compensation at 40 °C | 350–500 W |
| Recovery Time (30 s door open, 37 °C) | 3–6 min |
| Rated Power | 1.2 kW |
| Internal Volume | 247–1020 L |
| Net Weight | 152–327 kg |
| Max. Load per Shelf | 30–45 kg |
| Max. Total Load | 100–150 kg |
| Wall Clearance (rear/side) | 100 mm |
| External Dimensions (W×H×D) | 925×1461×796 mm to 1250×1925×1149 mm |
| Internal Dimensions (W×H×D) | 650×785×485 mm to 973×1250×836 mm |
| Shelf Capacity (standard/max) | 2/9 to 2/15 |
| Sound Pressure Level | 43–47 dB(A) |
| Energy Consumption at 37 °C | 65–105 Wh/h |
| Interface | Ethernet, USB |
| Display | LCD with alarm and data logging |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KB Series |
| Temperature Range | 0 °C to +70 °C |
| Temperature Uniformity at 37 °C | ±0.2 K |
| Temperature Fluctuation at 37 °C | ±0.1 K (KB 130 and larger) |
| Recovery Time after 30-sec Door Opening at 37 °C | 3 min |
| Internal Volume | 63 L to 1070 L |
| Power Consumption | 0.9 kW to 1.5 kW |
| Refrigerant | R-600a |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Manufacturer | BINDER GmbH |
| Type | Imported |
| Model | KB 1060 |
| Cooling Method | Compressor-based refrigeration |
| Heating Method | Water-jacketed heating |
| Temperature Range | 0 °C to +70 °C |
| Temperature Stability | ±0.1 °C |
| Temperature Uniformity | ±0.2 °C at 37 °C |
| Chamber Volume | 1070 L |
| External Dimensions (W×H×D) | 1285 mm × 1951 mm × 1175 mm |
| Refrigerant | R-600a |
| Insulation | HIT multi-layer jacket technology |
| Interior | Electropolished stainless steel (AISI 304) |
| Inner Door | Safety glass with metal oxide coating |
| Shelving | 2 adjustable stainless steel shelves |
| Data Interface | Ethernet, USB |
| Compliance | DIN 12880 Class 3.3 temperature safety device, GLP-compliant data logging |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KBF-S ECO Solid.Line |
| Temperature Range (with Humidification) | 0 °C to +70 °C |
| Humidity Range | 10 % to 98 % RH |
| Temperature Uniformity (25 °C / 60 % RH) | ±0.1 K |
| Temperature Fluctuation (40 °C / 75 % RH) | ±0.1 K |
| Humidity Fluctuation (40 °C / 75 % RH) | ±0.3 % RH |
| Recovery Time after 30-sec Door Opening (40 °C / 75 % RH) | 11–17 min |
| Internal Volume Options | 247 L, 400 L, 700 L, 1020 L |
| Power Consumption (25 °C / 60 % RH) | 55–90 Wh/h |
| Noise Level | 45–49 dB(A) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KT53 / KT115 / KT170 |
| Temperature Range | 4 °C to 100 °C |
| Internal Volume | 53 L / 102 L / 163 L |
| External Dimensions (W×H×D, mm) | 660×635×630 / 860×715×655 / 860×1025×655 |
| Internal Dimensions (W×H×D, mm) | 400×400×334 / 600×455×355 / 600×765×355 |
| Net Weight | 63 kg / 83 kg / 102 kg |
| Inner Door | Tempered Safety Glass (ESG) |
| Interior | Stainless Steel Construction |
| Shelving | 2 Removable Stainless Steel Trays |
| Stacking Capability | Up to KT115 Units |
| Origin | China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | SHH-250LD / SHH-150LD |
| External Dimensions (D×W×H) | 67×71×146 cm (SHH-250LD) / 66×63×121 cm (SHH-150LD) |
| Chamber Dimensions (D×W×H) | 49×60×85 cm (SHH-250LD) / 48×52×60 cm (SHH-150LD) |
| Capacity | 250 L / 150 L |
| Temperature Range | +4 to 50 °C |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Uniformity | ±1 °C at 37 °C |
| Heating Power | 1.0 kW (SHH-250LD) / 0.8 kW (SHH-150LD) |
| Compliance | Q/WD11–2001, JB/T 6823–1993 (for humidity variants) |
| Brand | Biostream |
|---|---|
| Origin | Netherlands |
| Model | BH-25 |
| Temperature Range | Ambient +5°C to 65°C |
| Chamber Volume | 260 L |
| Temperature Uniformity | < ±0.3°C at 37°C |
| Temperature Stability | ±0.1°C at 37°C |
| Control Interface | 7" TFT Touchscreen |
| Heating Power | 610 W |
| Internal Dimensions (W×D×H) | 530 × 590 × 900 mm |
| External Dimensions (W×D×H) | 630 × 680 × 1125 mm |
| Net Weight | 115 kg |
| Shelf Capacity | Standard 3 / Max 8 stainless steel adjustable shelves |
| Door Type | Double-sealed tempered glass inner door |
| Safety Features | Independent overtemperature protection, audible/visual alarm, automatic heating cutoff, door-open interlock (fan & heater shutdown), surface temperature safety compliance |
| Timer Range | 1 min – 99 h 59 min |
| Order Code | B6X31250 |
| Brand | Biostream |
|---|---|
| Origin | Netherlands |
| Model | Pharm 5 |
| Chamber Material | SS316 Stainless Steel |
| Temperature Uniformity | ±0.2°C |
| Temperature Stability | ±0.1°C |
| CO₂ Control Range | 0–20% (±1% FS) |
| Humidity Control | Direct Clean Steam Generation via 140°C SS316L Heating Plate |
| O₃ Monitoring Range | 0–100 ppm (±2% FS) |
| O₃ Generation | 4–8 g/h |
| Max Load Capacity | 35 kg per Shelf |
| Amplitude Options | 25 mm / 50 mm (microbial), 3 mm (96-well) |
| Rotation Speed Range | 20–1,000 rpm |
| Communication Protocols | RS485, RJ45 (Modbus TCP/IP), USB |
| Compliance | Designed for GMP environments, supports GLP audit trails, ozone & UV sterilization validation |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | BAT70/150/250/360/600-GSH |
| Air Circulation | Forced Convection |
| Temperature Range | 4°C to 60°C |
| Temperature Accuracy | ±0.1°C |
| Temperature Fluctuation | ±0.2°C |
| Temperature Uniformity | ±0.8°C (within same horizontal plane) |
| Capacity | 70 L / 150 L / 250 L / 360 L / 600 L |
| External Dimensions (W×D×H) | 570×600×1220 mm (BAT70-GSH) |
| Brand | Boante |
|---|---|
| Model | BAT260/360/500/650/850/1050/1600/2500-GZ |
| Temperature Range | 5–50 °C |
| Temperature Uniformity | ±1 °C (at same shelf level) |
| Humidity Range | Not applicable (GZ series is humidity-free) |
| 光照 Intensity | 0–600 μmol/m²/s (0–100% continuously adjustable, measured at 100 mm from LED source) |
| Light Source | Top-mounted horizontal LED array with independent per-shelf dimming control |
| Capacity | 260–2500 L |
| Control System | BAT200PG intelligent controller with 7-inch color touchscreen, 24-segment programmable cycle (real-time Beijing time), adaptive three-stage fuzzy logic PID algorithm |
| Data Logging | Internal storage for ≥5 years of timestamped temperature and operational data |
| Safety Protections | Compressor overheat, fan overheat, overtemperature, high-pressure cutoff, overload protection, independent mechanical overtemperature limiter |
| Certifications & Compliance | Designed to support GLP-compliant workflows |
| Brand | Boante |
|---|---|
| Model | BAT70/150/250/360/460/600GZ-M or BAT70/150/250/360/460/600QH-M |
| Temperature Range | 5–50 °C |
| Temperature Uniformity | ±1 °C (at same level) |
| Humidity Range (QH-M only) | 40–80 %RH (with light on), 50–90 %RH (with light off), within 15–45 °C operating range |
| Humidity Control Accuracy | ±1 %RH |
| Illuminance | Up to 12,000 lx (adjustable in 6 levels, measured at 100 mm from LED source) |
| Light Source | 4000 K white LED array mounted on door |
| Control Interface | 4.3″ color LCD (GZ-M) or optional 7″ touch screen (QH-M) |
| Programming | 30-segment ramp-soak profile with real-time countdown |
| Cooling System | Balanced refrigeration with auto-defrost heat-pump cycle |
| Interior Power Outlet | 220 V AC, 10 A |
| Chamber Volume | 70 / 150 / 250 / 360 / 460 / 600 L |
| Safety Protections | Compressor overheat, fan overheat, overtemperature, high-pressure cutout, overload protection |