Inductively Coupled Plasma Optical Emission Spectrometer
Filter
Showing 31–51 of 51 results
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Avio® 550 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Plasma Orientation | Vertical Torch Configuration |
| Software Platform | Syngistix™ for ICP |
| Sample Introduction System | Scott/Cross-Flow Nebulizer with Cyclonic Spray Chamber |
| Optional Capability | HF-Compatible Sample Handling |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | ICPE-9800 |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Argon Purity Requirement | ≥99.95% |
| Minimum Argon Flow (Eco Mode) | 5 L/min |
| UV Spectral Range | 165–190 nm |
| Optical System | Two-Dimensional Cross-Dispersion with Sealed Vacuum Chamber |
| Detector | High-Resolution Megapixel CCD |
| Torch Configuration | Vertical Dual-View Design |
| Software Platform | ICPESolution v3.x with Automatic Interference-Free Wavelength Selection |
| Brand | SHINE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Sequential Scanning ICP-OES |
| Detection Limit | Sub-ppb to low-ppb range |
| Precision (RSD) | ≤0.5% (short-term) |
| Wavelength Range | 180–800 nm (2400 grooves/mm grating) / 190–500 nm (3600 grooves/mm grating) |
| Optical Resolution | 0.004 nm (2400 L/mm) / 0.002 nm (3600 L/mm) |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SPEC Pro 6000 |
| Instrument Type | Full-Spectrum Simultaneous Readout |
| Safety Integration | Integrated Glovebox System |
| RF Generator Architecture | Separated Solid-State RF Source |
| Optical System | Echelle Grating with Thermally Stabilized Optics |
| Detector | Back-Illuminated High-Speed CCD with Anti-Blooming Design |
| RF Power Range | 700–1600 W (Continuously Adjustable) |
| RF Cooling | Water-Cooled |
| Power Stability | <0.1% |
| Gas Control | Multi-Channel Digital Mass Flow Controllers (Accuracy: ±0.01 L/min) |
| Nebulization System | 12-Rotor, 4-Channel Peristaltic Pump with Optional Internal Standard/Standard Addition Capability |
| Torch Design | Modular, Self-Aligning, Center-Tube-Replaceable Echelle Torch |
| Software Platform | Element V (Fully Localized Chinese Interface with GLP-Compliant Audit Trail) |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | New SPECTRO ARCOS |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Detection Limit | <1 ppb |
| Precision (RSD) | 0.5% |
| Long-Term Stability | 1% |
| Wavelength Range | 130–770 nm |
| Optical Resolution | <8.5 pm |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SPECTRO ARCOS |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Detection Limit | Sub-ppb to ppm |
| Repeatability | ≤1% RSD |
| Long-Term Stability | ≤0.1% RSD |
| Wavelength Range | 130–770 nm |
| Optical Resolution | ≤0.008 nm |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTRO GENESIS |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Optical Detection | Dual-View Vertical Torch Configuration |
| Cooling | Air-Cooled Only |
| Purge Gas Flow | As Low as 0.5 L/min |
| Linear Dynamic Range | Sub-ppb to Percent Level |
| Sample Throughput | Up to 700 Samples per Day |
| Optical Architecture | DSOI (Dual-Spectrometer Optimized Imaging) |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTRO GENESIS |
| Type | Full-Spectrum Simultaneous ICP-OES |
| Wavelength Range | 175–770 nm |
| RF Generator | 27 MHz Solid-State |
| Optical Purge Flow | ≥0.5 L/min (Argon or Nitrogen) |
| Sample Throughput | Up to 700 samples/day |
| Detector | High-Quantum-Efficiency CCD Array |
| Compliance | ASTM D5185, D6595, ISO 11885, USP <233>, EPA Methods 200.7, 6010D, 6020B, GLP/GMP-ready with 21 CFR Part 11–compliant software options |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SpectrOil 100 |
| Pricing | Available Upon Request |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SPECTROGREEN |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Detection Limit | Sub-ppb |
| Precision (RSD) | <1.5% |
| Long-Term Stability (RSD) | <0.5% |
| Wavelength Range | 165–770 nm |
| Optical Resolution | 0.007 nm |
| Brand | SpectrUM / EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Model | EXPEC 6000 |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Detection Limit | Not Specified |
| Precision (RSD) | Not Specified |
| Long-Term Stability | Not Specified |
| Wavelength Range | Not Specified |
| Optical Resolution | Not Specified |
| Brand | Supernova / EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | EXPEC 6500 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Detection Limit | Not Specified |
| Precision (RSD) | <1% @ 8 h |
| Wavelength Range | 160–900 nm |
| Optical Resolution | Not Specified |
| RF Power Range | 500–1600 W (Digital Self-Excited Solid-State Generator) |
| Observation Mode | Dual-View Vertical Torch (Axial & Radial) |
| Detector | Custom Large-Area E-CCD |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Prodigy DC Arc |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | 0.1 ppm |
| Repeatability | ≤1.5% RSD |
| Stability | ≤2% RSD |
| Wavelength Range | 175–900 nm |
| Optical Resolution | ≤0.005 nm (at 200 nm) |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Prodigy |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | 0.1 ppm |
| Precision (RSD) | ≤1.5% |
| Stability (Drift) | ≤2% |
| Wavelength Range | 175–900 nm |
| Optical Resolution | ≤0.005 nm @ 200 nm |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Model | Prodigy Plus |
| Instrument Type | Full-Spectrum Direct-Reading ICP Optical Emission Spectrometer |
| Detection Limit (Zn @ 213.856 nm) | < 0.1 µg/L |
| Precision (RSD) | ≤ 0.5% |
| Long-Term Stability (RSD, 4h) | ≤ 1.0% |
| Wavelength Range | 130–1100 nm |
| Optical Resolution | 0.005 nm @ 200 nm |
| Detector | Custom 28 × 28 mm CMOS sensor with 3.38 million effective pixels |
| Readout Speed | >10× faster than conventional CID/CCD detectors |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Model | Prodigy7 |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Detection Limit (Zn at 213.856 nm) | <0.1 µg/L |
| Precision (RSD) | ≤1.0% |
| Stability (RSD over 4 hours) | ≤1.0% |
| Wavelength Range | 165–1100 nm |
| Optical Resolution | ≤0.007 nm @ 200 nm |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Full-Spectrum Simultaneous Readout |
| Detection Limit (Ca at 396.847 nm) | 0.155 ppb |
| Precision (RSD) | ≤0.5% |
| Long-Term Stability (2-hr drift) | ≤1.0% |
| Optical Resolution | 0.005 nm |
| RF Generator Cooling | Air-Cooled |
| Plasma Torch Assembly | Ceramic RF Load Coil |
| Optical System | Echelle Grating with ICCD Detector |
| Compliance | ASTM D1976, ISO 11885, USP <233>, EPA Methods 200.7 & 6010E |
| Brand | Thermo Fisher |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | iCAP 7000 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Price Range | USD 135,000 – 162,000 (estimated FOB UK) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Origin Category | Imported |
| Model | iCAP PRO |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | Not Specified |
| Precision (RSD) | Not Specified |
| Stability | Not Specified |
| Wavelength Range | Not Specified |
| Optical Resolution | Not Specified |
| Brand | Titan Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ICP-5000 |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | µg/L (ppb-level) |
| Repeatability | RSD ≤ 0.5% |
| 4-Hour Stability | RSD < 2.0% |
| Wavelength Range | 165–870 nm |
| Optical Resolution | ≤ 0.007 nm (at 200 nm) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | ICP-5500 |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limits | Al 167.0 nm, P 178.2 nm, B 182.6 nm, Se 196.0 nm, Pb 220.3 nm, Na, K — all < 10 µg/L |
| Precision (RSD) | ≤0.5% at 1 mg/L (n=10) |
| Long-Term Stability (RSD) | ≤2.0% at 1 mg/L over 4 h |
| Wavelength Range | 165–870 nm |
| Optical Resolution | ≤0.007 nm (FWHM at Mo 202.030 nm) |
| RF Generator Power | 0.5–1.6 kW, continuously adjustable |
| Plasma Observation Mode | Dual-view (axial + radial) |
| Detector | High-resolution solid-state CCD/CMOS array (>1 M pixels), thermoelectrically cooled to ≤−45 °C |
| Background Correction | Real-time, pixel-by-pixel |
| Linear Dynamic Range | ≥4–5 orders of magnitude |
| Warm-up Time | ≤30 min (optical chamber stabilized at 35 °C ± 0.1 °C) |