Industrial Micro CT System
Filter
Showing 31–60 of 60 results
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | Cultural Heritage CT Scanning & Analysis System |
| Pricing | Upon Request |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic |
| Model | 20 kV–450 kV High-Energy Industrial CT |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Translation-Rotation (TR) |
| Density Resolution | 0.5% |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | Industrial CT 3D Scanning System |
| Pricing | Available Upon Request |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | AOLONG1 |
| Pricing | Available Upon Request |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PCB Inspection CT System |
| Quotation | Upon Request |
| X-ray Tube Voltage | 160 kV or 225 kV |
| X-ray Tube Type | Open-type Microfocus Tube |
| Target Geometry | Transmission Target |
| Target Material | Tungsten |
| JIMA Resolution | Up to 0.5 µm |
| Scan Geometry | Cone-beam CT |
| Detector | Digital Flat-panel Detector |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | X-ray Digital Real-time Imaging System |
| Pricing | Upon Request |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | X-ray Real-time Imaging Inspection System |
| Pricing | Upon Request |
| Spatial Resolution | 16–60 lp/cm (selectable configurations) |
| Contrast Sensitivity | 0.7%–2% |
| Tube Voltage Range | 20–450 kV |
| Tube Current Range | 0–20 mA |
| Detector Options | Digital Flat-panel Detector / High-resolution Micron-scale Line-scan Digital Detector / Image Intensifier |
| Motion Control | 4-axis / 5-axis / Multi-axis Programmable Scanning Platform |
| Radiation Compliance | Meets GBZ 138–2002 and GB 18871–2002 |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | X-Ray Real-Time Imaging System |
| Pricing | Available Upon Request |
| Brand | AoLong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | XYG-1610 |
| Pricing | Upon Request |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | SKYSCAN 1273 |
| X-ray Source Energy | 40–130 kV, up to 39 W |
| Detector | 6 MP CMOS flat-panel, 3072 × 1944 pixels |
| Spatial Resolution | < 5 µm (3D) |
| Voxel Size | < 3 µm |
| Maximum Sample Dimensions | Ø300 mm × H500 mm, up to 20 kg |
| Field of View | Ø250 mm × H250 mm |
| Image Matrix | up to 4800 × 4800 pixels |
| Detector Output Speed | High-frame-rate acquisition enabled |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Model | SkyScan 1273 |
| X-ray Source | 40–130 kV, up to 39 W |
| Detector | 6 MP CMOS flat-panel (3072 × 1944 pixels) |
| Spatial Resolution | < 5 µm |
| Voxel Size | < 3 µm |
| Max Sample Dimensions | Ø250 mm × H250 mm |
| Max Sample Weight | 20 kg |
| Reconstructed Volume | up to 4800 × 4800 pixels |
| External Dimensions | 1250 × 815 × 820 mm (W × D × H) |
| Radiation Leakage | < 1 µSv/h at any point on external surface |
| Power Supply | 100–240 V, 50–60 Hz, 3 A |
| Weight | 400 kg (net) |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SkyScan 1275 |
| X-ray Source | 20–100 kV, 10 W, < 5 µm focal spot size at 4 W |
| Detector | 3 MP CMOS flat-panel detector (1944 × 1536 effective pixels) |
| Spatial Resolution | < 4 µm (nominal, at maximum magnification) |
| Density Resolution | < 4 µm (nominal, inferred from spatial resolution and contrast transfer performance) |
| Sample Capacity | Max height 120 mm, max diameter 96 mm |
| Dimensional Measurement Accuracy | Consistent with < 4 µm spatial resolution under calibrated conditions |
| Density Measurement Accuracy | Supported by high dynamic range (16-bit) detector and beam-hardening correction algorithms |
| Power Requirement | Standard 230 V AC, 50/60 Hz, single-phase outlet |
| Radiation Safety | Compliant with IEC 61000-6-3, IEC 61000-6-4, and national regulatory requirements for Class II B radiation devices |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | SkyScan 2211 |
| X-ray Source | 20–190 kV, 4/10/25 W, sub-micron focal spot size, 5-position filter wheel |
| X-ray Target | Tungsten (standard) |
| Detector | 3 MP CMOS flat panel (1920 × 1536 px) or 11 MP cooled CCD (4032 × 2670 px) |
| Reconstruction Volume (CMOS) | up to 3776 × 3776 × 1160 px (dual offset mode) |
| Reconstruction Volume (CCD) | up to 8000 × 8000 × 2272 px (dual offset mode) |
| Spatial Resolution | down to 100 nm (detector-limited, geometry-dependent) |
| Sample Capacity | Ø204 mm × L200 mm, max. 25 kg |
| Sample Positioning | direct-drive air-bearing rotation stage with integrated piezo-driven micro-positioning (5.5 mm travel) |
| Reconstruct Time | 1 min 12 sec (600 projections, 2K × 2K × 1K) |
| Radiation Safety | <0.5 µSv/h at 10 cm from surface (measured at 190 keV, 4 W on target) |
| Power Supply | 100–130 V or 200–240 V AC, 50–60 Hz |
| Cooling & Air Supply | integrated closed-loop water chiller and oil-free air compressor with particle filters and desiccant dryer |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SKYSCAN 2214 |
| X-ray Source | 20–100 kV, 10 W, <5 µm focal spot size at 4 W |
| Maximum Voxel Resolution | <0.35 µm (16 MP detector) / <0.45 µm (11 MP detector) |
| Max Reconstructed Volume | 14456 × 14456 × 2630 px (16 MP) or 11840 × 11840 × 2150 px (11 MP) |
| Sample Capacity | Ø ≤ 75 mm, H ≤ 70 mm (standard) |
| Detector | 16 MP (4904 × 3280 px) or 11 MP (4032 × 2688 px), 14-bit cooled CCD coupled 1:1 to scintillator via fiber optic taper |
| Spatial & Density Resolution | <0.35 µm (16 MP) / <0.45 µm (11 MP), isotropic voxel capability |
| Reconstruction Engine | InstaRecon® real-time GPU-accelerated 3D reconstruction |
| Scan Modes | Cone-beam, helical, phase-contrast enabled, dynamic time-lapse |
| Compliance | Fully compatible with ASTM E1441, ISO 15732, and USP <1059> for non-destructive volumetric analysis |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Model | SKYSCAN 2214 |
| X-ray Source | 20–100 kV, 10 W, <5 µm focal spot size at 4 W |
| Maximum Reconstruction Volume | 14456 × 14456 × 2630 px (16 MP detector) or 11840 × 11840 × 2150 px (11 MP detector) |
| Spatial Resolution | <0.35 µm (16 MP), <0.45 µm (11 MP) |
| Sample Capacity | Ø ≤ 75 mm, H ≤ 70 mm |
| Detector | 16 MP (4904 × 3280 px) or 11 MP (4032 × 2688 px), 14-bit cooled CCD coupled 1:1 to scintillator via fiber optic taper |
| Density Resolution | <0.35 µm (16 MP), <0.45 µm (11 MP) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | X4 POSEIDON |
| Detector Type | High-Resolution Scientific CMOS Sensor |
| Scan Mode | Translation-Rotation (TR) |
| Spatial Resolution | 2 µm |
| Density Resolution | <1% |
| X-ray Energy | 110 kV |
| Maximum Sample Dimensions | Ø110 mm × 300 mm (H) |
| Max Sample Weight | 5 kg |
| System Footprint | 1250 × 960 × 690 mm (L × D × H) |
| Precision Level | Nanoscale |
| Configuration | Modular Benchtop Micro-CT Platform |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | X4 POSEIDON |
| Detector Type | High-Resolution sCMOS Semiconductor Sensor |
| Scanning Mode | Translation-Rotation (TR) |
| Spatial Resolution | ≤2 µm (JIMA-verified) |
| System Architecture | Modular, Field-Upgradable |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | DEMT-8/16 |
| Detector Type | Custom Electromagnetic Sensor Array |
| Spatial Resolution | 5% of cross-sectional diameter |
| Density Resolution | Configurable (system-dependent) |
| Penetration Capability | Customizable per application |
| Measurement Range | Configurable (up to Ø300 mm cross-section) |
| Dimensional Accuracy | ±5% of cross-sectional dimension |
| Density Measurement Accuracy | Configurable |
| Operating Temperature | Up to 300 °C (non-contact probe interface) |
| Imaging Modes | Dual-mode (Eddy Current Tomography & Metal Flaw Detection) |
| Signal-to-Noise Ratio (SNR) | 60–90 dB |
| Frequency Range | 1 kHz–200 kHz (standard) |
| Channel Configuration | 8 or 16 independently configurable channels |
| Sampling Rate | Up to 100 kS/s per channel (flaw detection mode) |
| Reconstruction Grid | Up to 32×32 pixels (1% cross-sectional area resolution) |
| Front-End Signal Processing | Programmable 3-stage gain amplifier (1×–8×), with optional expansion |
| Data Output | Complex impedance components (real, imaginary, magnitude, phase), full complex-plane representation |
| Core Platform | FPGA-based digital acquisition and real-time processing architecture |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AXR |
| Pricing | Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AXR |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | United Kingdom |
| Model | X3305 |
| IP Rating | IP65 (standard), IP69K (optional) |
| X-ray Source Power | 20 W |
| System Length | 1.8 m |
| Compliance | GMP, NSF/ANSI 169, EHEDG Guideline Doc. 8.2 |
| Application Scope | Small-to-medium packaged food, pharmaceutical, and consumer goods |
| Brand | Neoscan |
|---|---|
| Origin | Belgium |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Sample Rotation Only (RO) |
| Spatial Resolution | 2 µm |
| X-ray Energy | 110 kV |
| Field of View | 100 mm × 163 mm |
| Maximum Sample Weight | 20 kg |
| System Dimensions | 1200 mm × 640 mm × 520 mm |
| Precision | Micron-Level |
| Brand | Nordson Dage |
|---|---|
| Origin | United Kingdom |
| Model | XD7500VR Jade FP |
| X-ray Tube Type | Open Transmission Tube |
| Operating Voltage Range | 30–160 kV |
| Target Power | 3 W |
| Feature Resolution | 950 nm (0.95 µm) |
| Geometric Magnification | Up to 1400× |
| System Magnification | Up to 4200× |
| Maximum Sample Dimensions | 736 × 580 mm |
| Detector Resolution | 1.33 MP |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing environment |
| Software Platform | DAGE VisionX™ v5.x with GLP-compliant audit trail and FDA 21 CFR Part 11-ready configuration options |
| Brand | Sanying Precision |
|---|---|
| Origin | Tianjin, China |
| Model | nanoVoxel-1000 |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Translation-Rotation (TR) |
| Spatial Resolution | 2 µm |
| Detail Resolution Capability | 300 nm |
| X-ray Source | Sealed-Tube |
| Maximum Tube Voltage | 110 kV |
| Field of View (FoV) | 300 mm (diameter) × 200 mm (height) |
| Sample Weight Capacity | 15 kg |
| System Dimensions (L×W×H) | 900 mm × 500 mm × 660 mm |
| Detector Active Area | 145 mm × 114 mm |
| Detector Pixel Matrix | 2940 × 2304 |
| System Mass | 500 kg |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | inspeXio 7000 |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Rotation-Only (RO) |
| X-ray Energy | 225 kV |
| Maximum Specimen Dimensions | Ø400 mm × H300 mm |
| Maximum Sample Weight | >12 kg |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | XSeeker 8000 |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Rotation-Only (RO) |
| Spatial Resolution | Micron-Level |
| Maximum Penetration | 100 mm Al-equivalent |
| Maximum Sample Dimensions | Ø300 mm × H320 mm |
| Maximum Sample Weight | 10 kg |
| System Footprint (Main Unit) | 893 mm (W) × 640 mm (D) × 526 mm (H) |
| Brand | Wkuang |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | XSTAFF-2000 |
| Price | Upon Request |
| Spatial Resolution | ≥50 µm |
| Maximum Sample Dimensions | Ø600 mm × H600 mm |
| Maximum Sample Weight | 100 kg |
| Brand | YXLON |
|---|---|
| Origin | Germany |
| Model | FF65 CL |
| Detector Type | Image Intensifier-Based Laminography Detector |
| Sample Diameter | 795 mm |
| Sample Height | 20 mm |
| Max Sample Weight | 2 kg |
| System Dimensions | 1760 × 2000 × 2000 mm |
| CT Mode | Super-High-Resolution Computed Laminography (CL) |
| Manipulation | Super-Precise Manipulator with Active Anti-Vibration System |
| Vacuum Sample Hold Mechanism | Integrated |
| Effective Detection Area | 510 × 610 mm |
| X-ray Source | Next-Generation Nanofocus Tube (≤ 300 nm focal spot) |
| Brand | YXLON |
|---|---|
| Origin | Germany |
| Model | FF70 CL |
| Detector Type | High-Sensitivity Image Intensifier with Nano-Focus X-ray Source |
| Max. Sample Diameter | 795 mm |
| Max. Sample Height | 150 mm |
| Max. Sample Weight | 2 kg |
| System Dimensions (W×D×H) | 1940 × 2605 × 2000 mm |
| CT Mode | Ultra-High-Resolution Computed Laminography (CL) |
| Manipulation | Ultra-Precise Active Anti-Vibration Manipulator |
| Minimum Resolvable Feature Size | <150 nm |
| Inspection Area | 510 × 610 mm |
| Brand | ZEISS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | BOSELLO MAX |
| Quotation | Upon Request |
| Detector Type | Flat-Panel Detector (FPD) |
| Scan Mode | Translation-Rotation (TR) |
| Inspection Volume | 1700 × 1700 × 2200 mm to 2600 × 2600 × 2600 mm |
| Sample Weight Capacity | 80 – 250 kg |