Infrared Moisture Analyzer
Filter
Showing 31–59 of 59 results
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HX204 / HS153 |
| Heating Source | Halogen Lamp |
| Maximum Sample Capacity | 200 g |
| Readability | 0.1 mg (HX204) |
| Compliance | ISO 8573-3, ASTM D4006, USP <921>, GLP/GMP-ready |
| Software | METTLER TOLEDO LabX™ (optional), One Click™ Moisture Interface |
| Cleaning Time | ≤30 s |
| Sensor Architecture | Monobloc Weighing Cell with Suspended Pan Design |
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Model | MB120 |
| Heating Method | Halogen Lamp |
| Capacity | 120 g |
| Readability | 0.01% / 0.001 g |
| Repeatability | 0.05% (3 g sample) / 0.015% (10 g sample) |
| Moisture Range | 0.01–100% (Moisture), 0.01–1000% (Regain) |
| Temperature Range | 40–230 °C |
| Display | 4.3″ QVGA TFT Color Touchscreen |
| Sample Pan Diameter | 90 mm |
| Dimensions (W×H×D) | 211 × 180 × 355 mm |
| Net Weight | 5.23 kg |
| Power Supply | 240 VAC, 50/60 Hz |
| Interface | RS232 (2 ports), USB Host (2 ports), USB Device |
| Operating Environment | 10–40 °C |
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Model | MB27ZH |
| Heating Method | Halogen Lamp |
| Capacity | 90 g |
| Readability | 1 mg / 0.01% |
| Pan Diameter | 90 mm |
| Part Number | 30128007 |
| Dimensions (W×D×H) | 17 × 14 × 28 cm |
| Brand | OHAUS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | MB32 |
| Pricing | Upon Request |
| Heating Method | Infrared |
| Max Capacity | 90 g |
| Readability | 1 mg / 0.01% moisture |
| Pan Diameter | 90 mm |
| Heater Type | Carbon Fiber |
| Communication | USB Device |
| Moisture Range | 0.01% – 100% |
| Temperature Calibration Points | 100°C, 160°C |
| Weight Calibration | External (50 g) |
| Dimensions (L×H×W) | 352 mm × 210 mm × 138 mm |
| Display | 4" LCD, dual-line |
| Results Shown | Moisture Content, Residual Solids, Moisture Regain, Heating Temperature, Elapsed Time, Method ID, Sample Weight |
| Heating Modes | Standard, Rapid |
| Built-in Screen Protector | Yes |
| Database Capacity | 2 test methods |
| Net Weight | 4.3 kg |
| Operating Ambient | 10°C – 40°C |
| Repeatability | ±0.02% (10 g sample), ±0.15% (3 g sample) |
| Shutdown Options | Automatic, Timed, Manual |
| Temperature Range | 40°C – 180°C |
| Environmental Compliance | CE, RoHS compliant |
| Brand | Perten |
|---|---|
| Origin | Imported (Sweden) |
| Model | AM 5200 |
| Heating Method | Radiofrequency (150 MHz) |
| Measurement Principle | RF Dielectric Constant |
| Sample Volume | 700 mL |
| Analysis Time | ~10 s |
| Display | 5.7-inch color resistive touchscreen |
| Communication | USB port |
| Operating Temperature Range | 0–40 °C |
| Power Supply | 115/230 V, 50/60 Hz |
| Dimensions (W×D×H) | 415 × 424 × 353 mm |
| Net Weight | 18.3 kg |
| Measured Parameters | Moisture content, bulk density, temperature |
| Sample Types | Cereals, oilseeds, pulses (soybeans, lentils), dry beans, seeds, and other agricultural commodities |
| Brand | Precisa |
|---|---|
| Origin | Switzerland |
| Model | 330XM |
| Heating Source | Halogen Lamp |
| Display | High-Contrast VFD Screen |
| Weighing System | Integrated 320XB Precision Electronic Balance |
| Sensor Technology | MFR Electromagnetic Force Restoration |
| Construction | Full Die-Cast Aluminum Housing |
| Calibration | External Calibration Mode |
| Compliance | Supports 3Q Validation (IQ/OQ/PQ) |
| Regulatory Features | Real-Time Clock, Password Protection, Mechanical Safety Interlock |
| Connectivity | Standard RS232 & USB |
| Brand | Precisa |
|---|---|
| Origin | Switzerland |
| Model | EM120-HR |
| Heating Source | Halogen Lamp |
| Display | Backlit LCD with Graphical Real-Time Moisture Trend Plot |
| Construction | Full Cast-Aluminum Housing |
| Calibration | Fully Automatic Smart Calibration System (SCS) |
| Compliance | Supports 3Q Validation (IQ/OQ/PQ), GxP-Compliant Real-Time Clock, Multi-Level User Access Control with Password Protection |
| Software Features | Built-in Automatic Repeatability Test (ART), Checkweighing, Statistical Analysis |
| Connectivity | Standard RS232 & USB |
| Brand | Precisa |
|---|---|
| Origin | Switzerland |
| Model | XM120 |
| Maximum Capacity | 124 g |
| Minimum Readability | 0.001 g |
| Moisture Resolution | 0.01% |
| Pan Diameter | 90 mm |
| Repeatability | ±0.2% (1 g sample), ±0.02% (10 g sample) |
| Heating Source | Halogen Lamp |
| Temperature Range | 30–230 °C |
| Temperature Increment | 1 °C |
| Drying Time Range | 0.1–99.9 min |
| Termination Modes | Automatic, Semi-Automatic (Δdigit/sec or Δ%/sec), Fixed-Time |
| Data Output Interval | 0.1–10.0 min |
| Password Protection | Yes |
| Statistical Functions | Count, Mean, Max, Min, Standard Error |
| Interface | RS232 |
| Memory | 50 Method Programs, 999 Test Records |
| Preheating | 30–100 °C |
| Multi-Stage Heating | 3 programmable segments (temp + time per stage) |
| Boost Mode | 140% target temp for first 3 min |
| Firmware Update | Remote via network |
| Brand | Precisa |
|---|---|
| Origin | Switzerland |
| Model | XM60 |
| Maximum Capacity | 62 g |
| Minimum Readability | 0.001 g / 0.01% |
| Pan Diameter | 90 mm |
| Repeatability | ±0.2% (1 g sample), ±0.02% (10 g sample) |
| Heating Source | Halogen Lamp |
| Temperature Range | 30–230 °C |
| Temperature Increment | 1 °C |
| Heating Mode | Boost Function (140% target temp for first 3 min) |
| Termination Modes | Automatic, Semi-Automatic (user-defined mass change per second), Timed (0.1–240 min) |
| Data Output Interval | 0.1–10.0 min |
| Preset Methods | 5 |
| Security | Password Protection, Physical Lock Slot |
| Interface | RS232 |
| Firmware Update | Remote download via network |
| Brand | Sartorius |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MA100 |
| Heating Method | Infrared |
| Key Features | 0.1 mg weighing precision, EC-type approval with CE conformity certificate, integrated motor-driven heating unit and sample chamber, SPRM auto-optimization function, modular heating source options (infrared ceramic, halogen, quartz), Plug&Dry™ cleaning system, optional built-in thermal printer |
| Compliance | CE-marked, compliant with ISO 8573-1 (for moisture in compressed air applications), supports GLP/GMP documentation requirements via audit trail-capable software |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | MA100 |
| Heating Method | Infrared (with optional halogen and quartz heating elements) |
| Readability | 0.1 mg |
| Certification | EC Type Approval for heating unit and weighing system |
| Drive Mechanism | Motor-driven integrated heating unit |
| Optional | Built-in thermal printer |
| Cleaning Design | Plug & Dry™ removable heating module |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | MA160 |
| Heating Method | Infrared |
| Application Scope | Laboratory & QC Environment |
| Method Storage Capacity | 100 methods |
| Cleaning Design | Removable heated module and sample chamber base plate (dishwasher-safe) |
| Status Indication | Visual status LED array |
| Method Development Time | ≤45 minutes (3-step guided workflow) |
| Performance Verification | Integrated test routine with ReproEasy reference pads |
| Compliance Context | Designed to support GLP/GMP workflows, audit-ready method documentation, and traceable instrument qualification |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | MA160-1CN |
| Heating Method | Infrared |
| Application Category | Laboratory & QC Moisture Analysis |
| Compliance Context | Designed for GLP/GMP environments, supports 21 CFR Part 11–compliant data integrity workflows (when integrated with optional software) |
| Method Storage Capacity | Up to 100 user-defined methods |
| Method Development Time | ≤45 minutes per new method (3-step guided workflow) |
| Cleaning Design | Removable heating module and sample chamber base plate, dishwasher-safe |
| Brand | Sartorius |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | MA35M |
| Heating Method | Infrared (Dual Metal-Tube IR Emitters) |
| Max Capacity | 35 g |
| Readability | 1 mg |
| Temperature Range | 40–160 °C (1 °C increments) |
| Heating Technology | IRPlug&Dry® Reflective Infrared Heating |
| Endpoint Detection | Automatic or Timed (0.1–99 min) |
| Compliance | FDA/HACCP-compliant versions available (V2 suffix) |
| Dimensions (W×D×H) | 224 × 366 × 191 mm |
| Weight | ~5.8 kg |
| Interface | RS-232C (unidirectional) |
| Sample Pan Diameter | 90 mm |
| Display | Graphical LCD with intuitive icon-based navigation |
| Reporting | GLP-compliant print templates (via optional thermal printer) |
| Brand | Sartorius |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | MA37 |
| Heating Method | Infrared (Metal Halide Heater) |
| Weighing Capacity | 70 g |
| Weighing Accuracy | ±0.2% for samples >1 g |
| Heating Source | Metal Halide Infrared Heater |
| Power Consumption | 640 VA |
| Line Voltage | 115 V / 230 V |
| Line Frequency | 50/60 Hz |
| Sample Chamber Access | Removable hood with wide-opening angle and SoftClose mechanism |
| Recommended Moisture Range | 0.01–100.00% (w/w) |
| Application Scope | Standard & thermosensitive materials |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | MA37 |
| Heating Method | Infrared |
| Weighing Capacity | 70 g |
| Heating Source | Metal Heater |
| Power Consumption | 640 VA |
| Line Voltage | 115 V / 230 V |
| Line Frequency | 50 / 60 Hz |
| Hood | Removable with Wide Opening Angle & SoftClose Mechanism |
| Weighing Accuracy | > 1 g: ±0.2 % |
| > 5 g | ±0.05 % |
| Recommended Moisture Range | 1–100 % |
| Brand | Sartorius |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MA37-1CN |
| Price | USD 2,950 (approx.) |
| Heating Method | Infrared Metal Heater |
| Maximum Sample Capacity | 70 g |
| Readability | 1 mg / 0.01% |
| Voltage | 115 V / 230 V AC |
| Moisture Range | 0.01–99.99% |
| Programmable Methods | Yes |
| Compliance | Designed for GLP/GMP environments with audit-ready operation log |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MOC-120H |
| Price Range | USD 1,400 – 4,200 |
| Brand | Shimadzu |
|---|---|
| Model | Unibloc MOC63U |
| Heating Source | Halogen Lamp |
| Temperature Range | 50–200 °C |
| Minimum Sample Weight | 0.001 g |
| Display | Backlit LCD |
| Interfaces | RS-232C, USB, DATA I/O |
| Data Export | Direct to Microsoft Excel via Windows Pass-Through Window |
| Measurement Modes | Auto-Stop, Time-Stop, Standard/Fast/Slow/Step Drying |
| Dimensions (L) | 202 mm |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Line | DHS Series |
| Heating Method | Infrared |
| Max Capacity | 61 g / 100 g / 120 g |
| Readability | 0.1 mg / 0.001% (HR models), 1 mg / 0.01% |
| Display | Backlit LCD with 5-key interface |
| Temperature Range | 50–160 °C (DHS-16A), 50–200 °C (DHS-20A) |
| Temperature Increment | 1 °C (from 50 °C) |
| Heating Time Setting | 0–99 min (1-min steps) |
| Termination Modes | Auto (weight stability), Timed, Manual |
| Built-in Methods | 50 user-programmable protocols |
| Output Parameters | Initial mass (g), Residual mass (g), Moisture content (% w/w), Dry matter (%), Moisture loss (%), Regain (%), Wet basis moisture (%), Heating mode, Set temperature, Duration |
| Calibration | External weight calibration (100 g standard |
| Interface | RS232 |
| Compliance Support | IQ/OQ/PQ documentation templates available |
| Power Supply | 220 VAC (±15% / −10%), 50 Hz |
| Power Consumption | 400 W |
| Operating Environment | 5–40 °C, 25–85% RH (non-condensing) |
| Optimal | 15–30 °C, 50–75% RH (non-condensing) |
| Dimensions (W×D×H) | 510 × 353 × 333 mm |
| Weight | 8.9 kg |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Line | LHS Series |
| Heating Method | Halogen Lamp |
| Maximum Capacity | 61 g / 100 g / 120 g |
| Readability | 0.1 mg / 0.001% (HR models), 1 mg / 0.01% |
| Display | Backlit LCD with 5-key interface |
| Temperature Range | 50–160 °C (LHS-16 models), 50–200 °C (LHS-20 models) |
| Temperature Increment | 1 °C (from 50 °C) |
| Heating Time Setting | 0–99 min (1-min increments) |
| Termination Modes | Automatic (weight change-based), Timed, Manual |
| Built-in Methods | 50 pre-programmed |
| Result Outputs | Initial mass (g), Residual mass (g), Moisture content (%), Dry matter (%), Moisture loss (%), Rehydration ratio, Wet basis moisture (%) |
| Calibration | External weight calibration (100 g standard |
| Interface | RS232 |
| Compliance Support | IQ/OQ/PQ documentation support |
| Power Supply | 220 VAC (−15% to +10%), 50 Hz |
| Power Consumption | 420 W |
| Operating Environment | 5–40 °C, 25–85% RH (non-condensing) |
| Optimal | 15–30 °C, 50–75% RH (non-condensing) |
| Dimensions (W×D×H) | 510 × 353 × 333 mm |
| Net Weight | 8.9 kg |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | YLS-B Series |
| Price Range | USD 700 – 1,400 (FOB) |
| Heating Method | Halogen Lamp |
| Max Capacity | 60 g (YLS-B Plus) / 20 g (YLS-B Standard) |
| Readability | 1 mg (60 g model) / 2 mg (20 g model) |
| Moisture Resolution | 0.02–0.1% |
| Temperature Range | 50–160 °C (1 °C increments) |
| Heating Time | 0–99 min (1 min steps) |
| Display | Backlit dot-matrix LCD with dual blue/white background |
| Data Storage | 50 sample profiles |
| Interface | RS232C |
| Calibration | External weight calibration (20 g for YLS-B |
| Compliance | Supports IQ/OQ/PQ validation |
| Power Supply | 220 VAC (±15%/+10%), 50 Hz |
| Power Consumption | 300 W |
| Operating Environment | 5–40 °C, 25–85% RH (non-condensing) |
| Recommended Ambient | 15–30 °C, 50–75% RH (non-condensing) |
| Dimensions (W×D×H) | 458 × 278 × 246 mm |
| Net Weight | 5.5 kg |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-100A-1 |
| Heating Source | Halogen Lamp |
| Weighing Range | 0–100 g |
| Readability | 1 mg |
| Repeatability (3 g sample) | ±0.3% |
| Recommended Sample Mass | 3–10 g |
| Minimum Sample Mass | 0.5 g |
| Heating Time Setting | 1–99 min (1 min increments) |
| Temperature Range | 50–160 °C |
| End Point Control | Timer-based or Auto-termination |
| Display | Backlit dot-matrix LCD showing moisture %, solids %, weight, elapsed time |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Communication Interface | RS232 |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-10A |
| Heating Method | Halogen Lamp |
| Display | High-Resolution Backlit Dot-Matrix LCD |
| Interface | RS-232C |
| Features | Automatic Tare, Zero Drift Compensation, Real-Time Dryness Monitoring |
| Compliance | Designed for ISO 5725 (accuracy & reproducibility), ASTM E1447 (moisture in solids), and USP <921> (Loss on Drying) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-50A-1 Halogen Moisture Analyzer |
| Heating Source | Halogen Lamp |
| Readability | 1 mg |
| Weighing Range | 0–50 g |
| Repeatability (3 g sample) | ±0.2% |
| Recommended Sample Mass | 3–10 g |
| Heating Time | 1–99 min (1 min increments) |
| Temperature Range | 50–180 °C |
| End Point Modes | Timed & Automatic |
| Display | Moisture %, Solid %, Weight (g), Time, Date |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Communication | RS232 |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-50A-1 |
| Heating Source | Halogen Lamp |
| Readability | 1 mg |
| Weighing Range | 0–50 g |
| Repeatability (3 g sample) | ±0.2% |
| Recommended Sample Mass | 3–10 g |
| Heating Time Range | 1–99 min (1 min increments) |
| Temperature Range | 50–180 °C |
| Endpoint Modes | Timed & Automatic |
| Display | Moisture %, Solid %, Weight, Time, Date |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Gross Weight | 6 kg |
| Interface | RS232 |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-50A-5 |
| Heating Source | Halogen Lamp |
| Weighing Range | 0–50 g |
| Readability | 5 mg |
| Temperature Range | 50–160 °C |
| Heating Time | 1–99 min (1-min increments) |
| Sample Capacity | 0.5–10 g (recommended: 3–10 g) |
| Repeatability (3 g sample) | ±0.3% |
| Display | Backlit dot-matrix LCD |
| Interface | RS232 |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Gross Weight | 6 kg |
| End-point Modes | Timed & Automatic |
| Heating Profile | Standard |
| Display Outputs | Moisture %, Solid %, Sample Weight, Elapsed Time |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | TSF-50A-5 |
| Heating Source | Halogen Lamp |
| Display | 4.3-inch Capacitive Touchscreen LCD |
| Readability | 0.01% / 1 mg |
| Compliance | GB/T 29249–2012 (Electronic Moisture Analyzer Based on Drying Method) |
| Interface | RS232 for Printer & PC Connectivity |
| Data Output | Real-time Drying Curve, Auto-finalization, Lock-on-Completion |
| Brand | Yuntang |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | YT-NIR-T |
| Heating Method | Infrared |
| Measurement Range | 0–100% w/w |
| Accuracy | ±0.2% w/w (subject to material composition variation) |
| Light Source | Imported high-efficiency NIR source |
| Filter Cycle | 1–60 s |
| Illumination Diameter | 60–75 mm |
| Working Height | 350 mm + 100 mm tolerance |
| Measurement Channels | 50 |
| Probe Window Material | High-borosilicate quartz glass |
| Operating Environment | −40 °C to +70 °C, 5–95% RH (non-condensing) |
| Power Supply | 220 VAC / 50 Hz |
| Communication Interfaces | RS485, 4–20 mA analog output, RS232, Ethernet (LAN), LoRa wireless |
| Enclosure Rating | IP65 |
| Display | Integrated industrial touchscreen |
| Probe Housing | High-strength aluminum alloy |