| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | BP-19 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Dimensions (L×W×H) | 500 × 200 × 180 mm |
| Display | 5.7-inch 32-bit touchscreen |
| Language Options | English / Chinese |
| Data Storage | 32 GB (≥1 million test records) |
| Print Output | Bilingual (English/Chinese), including test parameters, results, and pressure decay curves |
| Environmental Operating Conditions | 0–50 °C, 10–80% RH |
| Test Duration | Bubble point: 2 ± 2 min |
| Diffusion flow | 7 ± 2 min |
| Water intrusion | 7 ± 2 min |
| System leak check | 3 ± 1 min |
| Communication Interface | RS232/USB for PC connectivity and remote supervision via proprietary software |
| Compliance Support | Fully compatible with FDA 21 CFR Part 11 audit trail requirements, EU Annex 1, USP <1207>, ISO 13408-2, and GMP Annex 15 integrity testing protocols |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | BQS-19 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Test Pressure | 6900 mbar (sensor customizable) |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 10–80% RH |
| Dimensions (W×D×H) | 240 × 320 × 260 mm |
| Display | 5.7–7-inch color touchscreen, 256-color, GUI in English/Chinese |
| Data Storage | 32 GB internal, ≥1 million test records |
| Print Output | Thermal printer, bilingual (English/Chinese), includes test parameters, results, and pressure decay curves |
| Test Duration | Bubble Point: 2 ± 2 min |
| Diffusion Flow | 7 ± 2 min |
| Water Intrusion | 7 ± 2 min |
| System Leak Check | 3 ± 1 min |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | BQS-19 Series |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Test Duration (Bubble Point) | 2 ± 2 min |
| Test Duration (Diffusion Flow / Water Intrusion) | 7 ± 2 min |
| System Leak Test Time | 3 ± 1 min |
| Display | 5.7-inch 32-bit touchscreen |
| Data Storage | 32 GB (≥1 million records) |
| Interface | RS232/USB/Ethernet for PC connectivity |
| Compliance Support | FDA 21 CFR Part 11 (audit trail enabled), GMP/GLP-ready |
| Language Options | English & Chinese |
| Dimensions | 500 × 200 × 180 mm (L×W×H) |
| Environmental Operating Range | 0–50 °C, 10–80% RH |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BQS-19+ |
| Power Supply | 100–240 V AC, 50/60 Hz, ≤100 W |
| Max Operating Pressure | 9999 mbar |
| Min Inlet Pressure | 4000 mbar |
| Pressure Range for Testing | 100–8000 mbar (1.5–116 psi) |
| Bubble Point Accuracy | ±50 mbar |
| Diffusion Flow Accuracy | ±4% |
| Net Volume Test Accuracy | ±4% |
| Test Duration (Bubble Point) | 15 ± 2 min |
| Test Duration (Enhanced Bubble Point) | 20 ± 2 min |
| Test Duration (Diffusion Flow) | 10 ± 2 min |
| Display | 5.7" monochrome TFT LCD |
| Interface | RS232 serial port |
| Data Storage | 500 test records (configurable extension via PC connection) |
| Environmental Operating Conditions | 5–35 °C, 10–80% RH |
| Dimensions (W × D × H1 × H2) | 400 × 380 × 100 × 235 mm |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BQS-40 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Maximum Operating Pressure | 7999 mbar |
| Inlet Gas Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Dimensions (L×W×H) | 500 × 200 × 180 mm |
| Display | 5.7-inch 32-bit touchscreen |
| Language Options | English / Chinese |
| Data Storage | 32 GB (≥1 million test records) |
| Compliance | CE certified, FDA 21 CFR Part 11 compliant architecture, GMP-aligned audit trail |
| Enclosure Rating | IP54 |
| Supported Test Methods | Bubble Point, Diffusion Flow, Pressure Hold (Decay), Water Intrusion |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GT-2.0 |
| Pricing | Available Upon Request |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | GT-5.0 |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 120 W |
| Test Duration | 2–8 min |
| Pressure Range | 500–5000 Pa |
| Pressure Resolution | ≤50 Pa |
| Operating Noise | ≤50 dB(A) |
| Maximum Seal Pressure | ≤0.8 MPa |
| Data Storage Capacity | ≥10,000 test records |
| Gas Supply | Compressed air, nitrogen, or inert gas |
| Tray Configuration | Up to 6 glove trays (customizable) |
| Compliance | Designed per GB/T 25915.7–2010 / ISO 14644-7:2004 |
| Regulatory Alignment | 21 CFR Part 11–ready (electronic signatures, audit trail, user access control) |
| Optional Features | USB data export, audit trail module, backup data archiving |
| [Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BSQ-19 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar (customizable sensor) |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Dimensions (W×D×H) | 240 × 320 × 260 mm |
| Display | 5.7–7-inch color TFT touchscreen, 256-color, GUI in English/Chinese |
| Data Storage | 32 GB internal flash memory (≥1,000,000 test records) |
| Test Duration | Bubble Point: 2 ± 2 min |
| Diffusion Flow | 7 ± 2 min |
| Water Intrusion | 7 ± 2 min |
| System Leak Check | 3 ± 1 min |
| Environmental Operating Range | 0–50 °C, 10–80% RH |
| Compliance | Fully supports GMP documentation requirements, audit trail-ready configuration, user-level access control (Operator/Supervisor/Admin), 21 CFR Part 11–compatible data handling with electronic signature support] |
| Brand | Red Sun Instrument |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HR-W2400 |
| Pressure Range | 200–5000 Pa (adjustable) |
| Test Duration | 1–10 min (adjustable) |
| Pressure Resolution | 1 Pa |
| Acoustic Noise Level | ≤50 dB(A) |
| Operating Mode | Continuous |
| Bubble Point Accuracy | ±10 mbar |
| Diffusion Flow Resolution | 0.1 mL/min |
| Water Intrusion Flow Resolution | 0.01 mL/min |
| System Sensitivity | ±1.0 mbar |
| Max Test Pressure | 9999 mbar |
| Min Supply Pressure | 100 mbar |
| Gas Supply Requirement | Clean, dry air or nitrogen (4000–6999 mbar) |
| Power Supply | 100–240 V AC, 50/60 Hz, 100 W |
| IP Rating | IP54 |
| Data Storage Capacity | 10,000 test records |
| Display | 10-inch full-color TFT touchscreen |
| Communication Interfaces | RS232, USB, optional industrial bus (e.g., Modbus RTU), wireless module |
| Printer Options | Built-in thermal or dot-matrix printer |
| User Management | Up to 9-level permission hierarchy with electronic signature support |
| Audit Trail | Time-stamped, immutable event log (user login/logout, parameter changes, test execution, result modification, calibration, system errors) |
| Compliance | Fully aligned with FDA 21 CFR Part 11, EU Annex 11, and ISO 13485 |
| Brand | Red Sun Instrument |
|---|---|
| Origin | Hebei, China |
| Model | HR-WZX2600 |
| Price | USD 8,200 (FOB) |
| Application | Pharmaceutical Sterile Filtration Validation |
| Compliance Basis | ASTM F838-22, ISO 13408-2, USP <1207>, EU Annex 1 (2022), FDA Guidance for Industry – Sterile Drug Products (2004) |
| Brand | Red Sun Instrument |
|---|---|
| Origin | Hebei, China |
| Model | HRWZ-2600 |
| Power Supply | 100–240 V AC, 50/60 Hz, 120 W |
| Maximum Operating Pressure | 10,000 mbar (150 psi) |
| Inlet Gas Pressure Range | 100 mbar (1.5 psi) |
| Bubble Point Test Range | 100–8,000 mbar |
| Diffusion Flow Measurement Range | 1–600 mL/min |
| Water Intrusion Range | 0.01–100 mL/min |
| Test Accuracy | Bubble Point ±50 mbar |
| Dimensions (L×W×H₁×H₂) | 400 × 240 × 270 × 220 mm |
| Weight | 8 kg |
| Ambient Operating Conditions | 5–40 °C, 10–80% RH |
| Display | 7-inch high-resolution color touchscreen |
| Connectivity | RS232, USB, 4–20 mA analog output, RS485, 12 V alarm output |
| Data Storage | ≥10,000 test records |
| Pre-stored Methods | 120 |
| User Access Control | Four-tier permission system with username/password login |
| Audit Trail | Full event logging compliant with FDA 21 CFR Part 11 requirements |
| Test Modes | Manual bubble point, standard bubble point, enhanced bubble point, pressure hold, diffusion flow, water intrusion, ultrafiltration module testing |
| Brand | Red Sun Instrument |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HRYQ-2600 |
| Price | ¥72,000 CNY |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Dimensions (L×W×H) | 500 × 200 × 180 mm |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 10–80 % RH |
| Test Methods Supported | Pressure Hold (Diffusion Flow), Bubble Point (Standard & Enhanced), Water Intrusion, Manual Bubble Point |