| Brand | PUREN |
|---|---|
| Model | PAGM |
| Instrument Type | Online Ion Chromatograph with Integrated Aerosol Sampling & Pre-treatment System |
| Origin | Shandong, China |
| Manufacturer | PUREN Instrument Co., Ltd. |
| Pump Pressure Rating | 36 MPa |
| Flow Rate Range | 0–9.999 mL/min |
| Eluent Flow Rate | 1.0 mL/min |
| Max Operating Pressure | 15 MPa |
| Operating Temperature Range | 14–35 °C |
| Temperature Reproducibility | ±0.01 °C |
| Eluent Concentration Range | 1.0–5.0 mM |
| Brand | PUREN |
|---|---|
| Model | PIC-10 Dual-System |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Pump Max Pressure | 0–42.0 MPa (Stainless Steel), 0–36 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max Operating Pressure | 10 MPa (1500 psi) |
| Temperature Control Range | 5–65 °C |
| Temperature Stability | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PIC-10 Dual-System Fully Automated |
| Instrument Type | Laboratory Benchtop |
| Application Scope | Universal |
| Pump Maximum Pressure | 0–42.0 MPa (stainless steel), 0–36 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (adjustable in 0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max Operating Pressure | 10 MPa (1500 psi) |
| Temperature Control Range | 5–65 °C |
| Temperature Reproducibility | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Maximum Pump Pressure | 0–42.0 MPa (Stainless Steel), 0–35 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max System Operating Pressure | 10 MPa (1500 psi) |
| Column Oven Temperature Range | 5–65 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Laboratory Instrument |
| Model | PIC-10A Dual-System |
| Instrument Type | Benchtop Laboratory Ion Chromatograph |
| Application Scope | General-Purpose Quantitative Analysis of Inorganic Ions |
| Pump Max Pressure | 0–42.0 MPa (Stainless Steel), 0–35 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Maximum Operating Pressure | 10 MPa (1500 psi) |
| Operating Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.1 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop IC System |
| Configuration | Dual-Channel Simultaneous Anion/Cation Analysis |
| Pump Material Options | Stainless Steel (Max. 42.0 MPa) / PEEK (Max. 35 MPa) |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max. Operating Pressure | 10 MPa (1500 psi) |
| Column & Detector Oven Temperature Range | 5–65 °C |
| Temperature Stability | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Detection Modes | Conductivity (dual-channel), Amperometric (optional), UV-Vis (optional) |
| Integrated Components | Built-in degasser (pre- and post-suppressor), CO₂ removal module, electrochemical suppressor (continuous regeneration), column switching valve, auto-sampler interface, embedded high-resolution LCD control panel with real-time chromatogram display |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | PIC-10A (Dual-System Autosampler Configuration) |
| Detection Modes | Conductivity Detection (Standard), Optional Pulsed Amperometric Detection (PAD), DC Amperometric Detection, Integral Amperometric Detection, Differential Pulse Voltammetry |
| Anion Separation Range | F⁻, Cl⁻, NO₂⁻, NO₃⁻, SO₄²⁻, Br⁻, PO₄³⁻, ClO₂⁻, ClO₃⁻, BrO₃⁻ |
| Cation Separation Range | Li⁺, Na⁺, NH₄⁺, K⁺, Ca²⁺, Mg²⁺, Sr²⁺, Ba²⁺ |
| Detector | Dual Conductivity Detector (Simultaneous Anion/Cation Monitoring) |
| Pump System | Dual Microprocessor-Controlled Double-Plunger Reciprocating Pumps |
| Flow Pulsation | Minimized via Intelligent Flow Algorithm |
| Gradient Capability | Binary to Quaternary Gradient Elution |
| Fluidic Path Materials | PEEK (Imported, Acid/Base/100% Organic Solvent Compatible) |
| Suppressor | Auto-Regenerating Membrane Suppressor (pH 0–14, On-Line Regeneration, Low Background Conductivity, Maintenance-Free Operation) |
| Thermostat | Integrated Internal Column & Detector Thermostat (Patent No. 200820019630.3) |
| Data Acquisition | High-Precision Digital-to-Analog Conversion |
| Interface | USB (Workstation Communication), RS-232/485 (Pump & Peripheral Control) |
| Autosampler | Electric-Valve Full-Loop Injection, Trace-Sample Compatible, Residual-Free, High Reproducibility (RSD < 1.2%) |
| Software Functions | Real-Time Parameter Remote Control, Baseline Subtraction, Automatic Peak Integration, Negative Peak Recognition, Fault Diagnostics & Instrument State Monitoring, Report Generation (PDF/CSV/XLS), Audit-Trail Ready Data Logging |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Application Scope | Universal (Anions & Cations) |
| Maximum Pump Pressure | 0–42.0 MPa (Stainless Steel), 0–36 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max System Operating Pressure | 10 MPa (1500 psi) |
| Column Oven Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | PIC-20 |
| Instrument Type | Laboratory Benchtop |
| Application Scope | General-Purpose Ion Analysis |
| Pump Maximum Pressure | 0–42.0 MPa (stainless steel), 0–35 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (adjustable in 0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| System Operating Pressure Limit | 10 MPa (1500 psi) |
| Column Oven Temperature Range | 5–65 °C |
| Temperature Stability | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Model | PIC-20 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Class | Laboratory Benchtop Ion Chromatograph |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Maximum Pump Pressure | 0–36.0 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max Operating Pressure | 10 MPa (1500 psi) |
| Operating Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.1 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Detector Configuration | Dual Conductivity Detectors + Optional Amperometric Detector |
| Column Oven | Integrated Peltier-heated Column/Suppressor Compartment (Patent No. ZL200820019630.3) |
| Data Storage | Local SSD + Cloud Synchronization |
| Connectivity | USB 2.0, Wi-Fi, Mobile App Remote Control (iOS/Android) |
| Compliance | Designed for ISO/IEC 17025 environments |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | PIC-30 |
| Instrument Type | Laboratory Benchtop System |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Maximum Pump Pressure | 36 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Operating Pressure | 10 MPa |
| Operating Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.04 °C |
| Eluent Concentration Range | 0–20 mM |
| Detector Options | Dual-Channel Conductivity Detector / Single-Channel Voltammetric Detector / Dual-Channel UV-Vis Detector |
| Fluidic Path | All-PEEK Non-Metallic Flow Path |
| Integrated Components | Embedded Chromatography Workstation, Auto-Sampler Interface, Onboard Dilution Module, Eluent Generator Compatibility (Optional), Internal Degasser, CO₂ Suppressor, Column Oven with Integrated Conductivity Cell & Suppressor |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable Ion Chromatograph |
| Model | PIC-60 |
| Pump Pressure Rating | 42 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Operating Temperature Range | 0–65 °C |
| Temperature Reproducibility | ±0.01 °C |
| Eluent Concentration Range | 0–80 mmol/L |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | PIC-80 |
| Instrument Type | Laboratory Benchtop |
| Application Scope | General-Purpose |
| Pump Max Pressure | 0–42.0 MPa (Stainless Steel) / 0–36 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Maximum Operating Pressure | 10 MPa (1500 psi) |
| Operating Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | PIC-80B |
| Instrument Type | Laboratory |
| Application Scope | General-purpose |
| Pump Pressure Rating | 0–42.0 MPa (stainless steel), 0–36 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max Operating Pressure | 10 MPa |
| Operating Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Online Analyzer |
| Application | General-Purpose Environmental & Industrial Process Monitoring |
| Pump Pressure Rating | 0–42.0 MPa (Stainless Steel) / 0–35 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max Operating Pressure | 10 MPa (1500 psi) |
| Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.1 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Essentia IC-16 |
| Instrument Type | Laboratory |
| Pump Pressure Rating | 0–36 MPa |
| Flow Rate Range | 0.001–10.00 mL/min |
| Eluent Flow Rate Range | 0.001–10.00 mL/min |
| Maximum Operating Pressure | 36 MPa |
| Column Oven Temperature Range | 30–85 °C |
| Temperature Reproducibility | Not specified |
| Eluent Concentration Range | Not specified |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | HIC-ESP |
| Instrument Type | Laboratory Benchtop System |
| Pump Maximum Pressure | 40 MPa |
| Flow Rate Range | 0.001–10.000 mL/min |
| Eluent Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Operating Pressure | 30 MPa |
| Column Oven Temperature Range | 20–85 °C |
| Temperature Reproducibility | ±0.1 °C |
| Eluent Concentration Range | 0.1–100 mM |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | IC-MS |
| Instrument Type | Laboratory Benchtop System |
| Application Scope | General-Purpose Ion Analysis |
| Maximum Pump Pressure | 0–36 MPa |
| Flow Rate Range | 0.001–10.000 mL/min |
| Eluent Concentration Range | 0.1–100 mM |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (PRC) |
| Model | IC-MS/MS |
| Instrument Type | Laboratory Benchtop System |
| Application Scope | General-Purpose Multi-Analyte Quantification |
| Pump Pressure Rating | 0–36 MPa |
| Flow Rate Range | 0.001–10.00 mL/min |
| Column Oven Temperature Range | Ambient +10 °C to 85 °C |
| Temperature Stability | ±0.1 °C |
| Eluent Concentration Range | 0.1–100 mM |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Detection Modes | Suppressed and Non-Suppressed Conductivity Detection |
| Application Scope | Trace Anion and Cation Analysis in Environmental, Pharmaceutical, Food, and Industrial Samples |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | Techcomp IC1020 Ion Chromatograph |
| Instrument Type | Laboratory Benchtop System |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Maximum Pump Pressure | 42 MPa |
| Flow Rate Range | 0.001–12.000 mL/min |
| Eluent Flow Rate Range | 0.001–12.000 mL/min |
| Operating Temperature Range | Ambient +5°C to 65°C |
| Temperature Stability (Column & Detector) | ≤0.1°C |
| Eluent Concentration Range | 0.01–100 mM KOH (OH⁻-based) |
| Compatible Detectors | Conductivity (standard), Amperometric (optional upgrade) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Thermo Fisher Cindion Combustion Ion Chromatography System |
| Price | Upon Request |
| Instrument Type | Laboratory |
| Application Scope | General-Purpose |
| Flow Rate Range | 100–500 mL/min |
| Maximum Operating Pressure | 30–45 psi |
| Operating Temperature Range | 500–1200 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | Mexico |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Instrument |
| Model | Aquion |
| Pump Pressure Rating | 5000 psi |
| Flow Rate Range | 0.00–5.00 mL/min |
| Eluent Flow Rate | 0.00–5.00 mL/min |
| Maximum Operating Pressure | 5000 psi |
| Column Oven Temperature Range | 30–60 °C |
| Temperature Reproducibility | ±0.5 °C |
| Eluent Concentration Range | 0.1–100 mM (dependent on eluent chemistry) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Mexico |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | Aquion RFIC |
| Instrument Type | Laboratory |
| Maximum Pump Pressure | 5000 psi |
| Flow Rate Range | 0.00–5.00 mL/min |
| Eluent Flow Rate Range | 0.00–5.00 mL/min |
| Maximum Operating Pressure | 5000 psi |
| Operating Temperature Range | Ambient +5°C to 60°C |
| Temperature Reproducibility | ±0.05°C |
| Eluent Concentration Range | 0.1–100 mM |
| Brand | Thermo Fisher |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC-manufactured) |
| Model | Dionex Easion Ion Chromatography System |
| Instrument Type | Laboratory Benchtop IC System |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Pump Pressure Range | 0–35 MPa |
| Flow Rate Range | 0.00–5.00 mL/min (single-pump-head design) |
| Maximum Operating Pressure | 10 MPa |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | ICS-1100 |
| Instrument Type | Laboratory Benchtop System |
| Maximum Pump Pressure | 6000 psi |
| Operating Pressure Range | Up to 5000 psi |
| Column Oven Temperature Range | 4–40 °C |
| Eluent Concentration Range | 0–100 mM (KOH), adjustable per eluent chemistry |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ICS-1600 |
| Instrument Type | Laboratory Benchtop System |
| Maximum Pump Pressure | 6000 psi |
| Operating Pressure Range | Up to 5000 psi |
| Column Oven Temperature Range | 4–40 °C |
| Eluent Concentration Range | 0–100 mM KOH (varies with eluent chemistry) |
| Eluent Generation Compatibility | RFC-30 Electrolytic Eluent Generator |
| Suppressor Type | AutoSuppression™ Electrolytic Micro-Membrane Suppressor |
| Software Platform | Chromeleon™ 7.3 or later |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Instrument |
| Model | ICS-4000 |
| Pump Pressure Rating | 6000 psi |
| Flow Rate Range | 0.001–0.100 mL/min |
| Eluent Flow Rate | 0.001–0.100 mL/min |
| Maximum Operating Pressure | 6000 psi |
| Operating Temperature Range | 10°C–40°C |
| Temperature Reproducibility | ±0.2°C |
| Eluent Concentration Range | 0–100 mM (KOH), dependent on eluent chemistry |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | ICS-4000 CD |
| Instrument Category | Laboratory Benchtop Ion Chromatograph Detector |
| Detection Principle | Suppressed/Unsuppressed Conductivity Detection |
| Dynamic Range | 0–15,000 µS/cm |
| Cell Volume | 0.02 µL (Capillary Mode) |
| Temperature Control | Independent, Microprocessor-Regulated Detector Thermostat |
| Interface | Plug-and-Play Auto-Recognition via Chromeleon™ CDS |
| Mounting | Tool-Free Snap-In Mechanism |
| Compatible Configurations | Series or Parallel Dual-Detector Setup |
| Flow Path Options | Capillary, Analytical (Standard-Bore and Microbore) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ICS-5000+ CD |
| Application Environment | Laboratory-Based Ion Chromatography System |
| Configuration Options | Capillary and Analytical (Standard-Bore & Microbore) Flow Paths |
| Detector Architecture | Digital Signal Processing (DSP)-Enabled, Thermally Stabilized Conductivity Detection Module |
| Dynamic Range | 0–15,000 µS/cm |
| Cell Volume (Capillary Mode) | 0.02 µL |
| Installation Interface | Tool-Free Snap-In Mounting with Auto-Detection via Chromeleon™ CDS |