| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | GB 8809-1988 Pendulum Impact Tester |
| Impact Energy Options | 1 J, 2 J, 3 J, 5 J (selectable) |
| Resolution | 0.001 J |
| Impact Head Diameter | Ø25.4 mm, Ø19 mm, Ø12.7 mm |
| Clamp Aperture | Ø89 mm, Ø60 mm |
| Specimen Size | 100 mm × 100 mm or Ø100 mm |
| Pneumatic Pressure Range | 0.3–1.5 MPa |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 492 × 383 × 752 mm |
| Net Weight | 44 kg |
| Compliance | GB/T 8809–1988, ASTM D3420, NF T54-116 |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | MPT-1102 |
| Load Capacity Options | 6 N (standard), 10 N / 30 N / 50 N / 100 N / 200 N / 300 N (optional) |
| Force Resolution | 0.001 N |
| Accuracy | ±0.03% FS |
| Test Speed Range | 1–500 mm/min (infinitely variable, touchscreen-controlled) |
| Effective Travel | 470 mm |
| Displacement Resolution | 0.01 mm |
| Jaw Width | 30 mm (standard), 55 mm (optional) |
| Peel Angles | 90° and 180° (vertical/horizontal configurations) |
| Temperature Control Option | PTC heating module (RT–100°C standard |
| Compliance Standards | GB/T 25256, GB 8808, GB 2792, ASTM D3330 |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 30 W |
| Dimensions (L×W×H) | 750 × 340 × 116 mm |
| Net Weight | 43 kg |
| Interface | Standard RS232/USB for external data transfer |
| Software Support | Flexpert analysis software (optional), DSM Laboratory Data Management System (optional) |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GTR-7004 |
| Price Range | USD 14,000–21,500 |
| Test Range | 15–15,000 s/100 mL (standard) |
| Resolution | 0.1 s/100 mL |
| Sample Count | 1 |
| Pressure Range | 20 kPa |
| Pressure Accuracy | ±0.01 kPa |
| Test Area | 1.0 in² (0.25 in² / 0.1 in² optional) |
| Max Sample Thickness | ≤5 mm |
| Test Gas | Clean compressed air (user-supplied) |
| Air Supply Pressure | 0.3–1.0 MPa |
| Interface | Ø6 mm pneumatic fitting |
| Dimensions | 320 × 380 × 410 mm (L×D×H) |
| Power | AC 220 V, 50 Hz |
| Net Weight | 25 kg |
| Compliance | ISO 5636-5, ASTM D726, TAPPI T460, GB/T 36363–2018 |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | OX2/231 |
| Price Range | USD 28,000 – 42,500 |
| Measurement Principle | Coulometric Sensor (ISO 15105-2 Compliant) |
| Test Method | Isobaric Equal-Pressure Mode |
| Chambers | 3 Independent Testing Cells |
| Temperature Control Range | 5–95 °C |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control | 0%RH, 35–90%RH (±1%RH accuracy) |
| Film OTR Range | 0.01–6500 cm³/m²·d (standard), up to 63,000 cm³/m²·d (optional) |
| Container OTR Range | 0.0001–62 cm³/pkg·d |
| Film Resolution | 0.001 cm³/m²·d |
| Container Resolution | 0.00001 cm³/pkg·d |
| Test Area | 48 cm² |
| Sample Size (Film) | ≥150 mm × 94 mm or circular |
| Sample Size (Container) | ≤Φ120 mm × 400 mm (H) |
| Max. Thickness | 3 mm |
| Carrier Gas | 99.999% High-Purity N₂ |
| Flow Rate | 0–200 mL/min |
| Interface | 1/8″ Stainless Steel Tubing |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 730 × 590 × 350 mm |
| Net Weight | 56 kg |
| Standards Compliance | GB/T 19789, ASTM D3985, ASTM F2622, ASTM F1307, ASTM F1927, ISO 15105-2, JIS K7126-B, YBB 00082003 |
| Software | Embedded Win-based Control & Analysis Suite with Audit Trail, Multi-level User Access (5 tiers), Real-time Curve Logging (T, RH, Flow, OTR), Optional DSM Laboratory Data Management System Integration |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | GTR-704R |
| Test Range | 10–15,000 s/100 mL (standard) |
| Resolution | 0.1 s/100 mL |
| Specimen Count | 1 |
| Pressure Range | 20 kPa |
| Pressure Accuracy | ±0.01 kPa |
| Test Area | 1.0 in² (0.25 in² / 0.1 in² optional) |
| Max Specimen Thickness | ≤5 mm |
| Test Gas | Clean Compressed Air (user-supplied) |
| Air Supply Pressure | 0.3–1.0 MPa |
| Interface | Ø6 mm pneumatic fitting |
| Dimensions (L×D×H) | 370 × 320 × 220 mm |
| Power | AC 220 V, 50 Hz |
| Net Weight | 20 kg |
| Standards Compliance | ISO 5636-5, ASTM D726, TAPPI T460, GB/T 36363–2018 |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYSTESTER GTR-1 |
| Price Range | USD 14,000 – 28,000 |
| Test Principle | Vacuum Pressure-Difference Method |
| Test Chamber | Single-cell |
| Temperature Control | Circulating medium thermostatic control (5 °C to 95 °C, optional) |
| Temperature Accuracy | ±0.1 °C |
| Vacuum Resolution | 0.1 Pa |
| Permeation Range | 0.01–170,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Sample Thickness Limit | ≤3 mm |
| Effective Test Area | 48 cm² |
| Sample Dimensions | ≥150 mm × 94 mm or circular |
| Test Gases | O₂, N₂, CO₂, air, He (user-supplied gas source, 0.3–1.0 MPa) |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 28 kg |
| Dimensions (L×D×H) | 330 × 600 × 330 mm |
| Compliance Standards | GB/T 1038–2000, ISO 15105-1, ISO 2556, ASTM D1434, JIS K 7126-1, YBB 00082003 |
| Software Features | Audit trail, system logging, 5-level user permission management, DSM LIMS integration (optional) |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | DIT-ASTM D1709 |
| Test Methods | ASTM D1709 (Method A & B), GB/T 9639, JIS K7124 |
| Mass Range | Method A: 50–2000 g |
| Method B | 300–2000 g |
| Resolution | 0.1 g (0.1 J) |
| Sample Clamping | Pneumatic, ≤1.1 MPa air supply required |
| Sample Size | >150 mm × 150 mm |
| Dimensions (A/B) | 450×450×1365 mm / 450×450×2160 mm |
| Power | AC 220 V, 50 Hz |
| Weight | 70 kg |
| Interface | Standard RS232/USB |
| Data Analysis | Built-in min/max/mean/SD calculation |
| Optional | Ball Impact Module, DSM Lab Data Management System, Safety Guard Kit |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Jinan SYSTESTER Heat Sealing Tester |
| Price Range | USD 4,200 – 7,000 |
| Touchscreen Interface | Industrial TFT LCD |
| UI Design | Zero-navigation-depth flat interface |
| Temperature Control | Dual independent sealing bars |
| Max Operating Temperature | 300 °C |
| Temp Range | RT + 6 °C to 300 °C |
| Temp Accuracy | ±0.2 °C |
| Sealing Time | 0.1–999.9 s |
| Sealing Pressure | 0.05–1.1 MPa |
| Sealing Area | 265 mm × 12 mm (customizable) |
| Sealing Mode | Dual-bar independent control |
| Pneumatic Interface | Ø6 mm |
| Air Supply Requirement | 0.05–1.1 MPa (user-supplied) |
| Dimensions (L×W×H) | 410 × 396 × 416 mm |
| Weight | 33 kg |
| Power | AC 220 V, 50 Hz |
| Safety Features | Emergency stop button, anti-scald housing, fanless design |
| Noise Level | <35 dB(A) |
| Standard Compliance | QB/T 2358 (equivalent to ZBY 28004), ASTM F2029, YBB00212005-2015 |
| Data Output | Integrated thermal printer |
| Communication Interface | Standard RS232/USB |
| Optional Integration | DSM Laboratory Data Management System (sold separately) |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | GTR-704R |
| Test Range | 10–15,000 s/100 mL |
| Resolution | 0.1 s/100 mL |
| Sample Area | 1.0 in² (0.25 in² / 0.1 in² optional) |
| Pressure Range | 20 kPa |
| Pressure Accuracy | ±0.01 kPa |
| Max Sample Thickness | ≤5 mm |
| Gas Supply | Clean compressed air (0.3–1.0 MPa) |
| Interface | Ø6 mm pneumatic fitting |
| Power | AC 220 V, 50 Hz |
| Dimensions | 370 × 320 × 220 mm (L×D×H) |
| Weight | 20 kg |
| Compliance | ISO 5636-5, ASTM D726, TAPPI T460, GB/T 36363–2018 |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | Membrane Separation Performance Evaluation System |
| Test Range | 0.01–2×10⁴ Barrer |
| Gas Flow Rate | 0–100 mL/min (200/300 mL/min optional) |
| Measurement Accuracy | ±0.01 Barrer |
| Vacuum Accuracy | ±0.1 Pa |
| Test Pressure Differential | 0–10 bar (system rated to 16 bar) |
| Temperature Control Range | 5–95 °C (±0.1 °C with optional chiller/heater) |
| Effective Test Area | Φ20 mm (3.14 cm²) |
| Sample Thickness Limit | ≤2 mm |
| Sample Capacity | 1 specimen per run |
| Detector Sensitivity | ≥5000 or 10000 mV·mL/mg (configurable) |
| Baseline Drift | ≤0.10 mV |
| Noise | ≤0.015 mV |
| Carrier Gas Pressure | 2 bar |
| Compatible Carrier Gases | N₂, H₂, He, Ar |
| Dimensions (Host) | 320 × 625 × 335 mm (W×D×H) |
| (GC Unit) | 590 × 480 × 500 mm (L×W×H) |
| Power Supply | AC 220 V, 50 Hz |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QBT 2411 |
| Price Range | USD 18,000 – 24,500 |
| Test Principle | Gravimetric Cup Method |
| Test Range | 0.001–220 µg/(m²·s) |
| Permeability Range | 1×10⁻³–40,000 ng/(m²·s·Pa) |
| Sample Capacity | 6 independent stations |
| Weight Resolution | 0.0001 g |
| WVTR Resolution | 0.00001 µg/(m²·s) |
| Temperature Range | 15–55 °C (±0.1 °C control accuracy) |
| Humidity Range | 10–95 %RH (±1 %RH control accuracy |
| Air Sweep Velocity | 0.5–2.5 m/s |
| Specimen Thickness Limit | ≤25 mm |
| Test Area | 33.17 cm² |
| Specimen Diameter | Φ81 mm |
| Chamber Volume | 36 L |
| Air Supply | Compressed air, 0.2–1.0 MPa, Φ8 quick-connect fitting |
| Power | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 650 × 550 × 475 mm |
| Net Weight | 67 kg |
| Compliance | GB/T 1037, QB/T 2411–1998 |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | TSL-1002 |
| Load Capacity Options | 50 N, 100 N, 250 N, 500 N, 1000 N, 2000 N |
| Test Speed Range | 0.1–1000 mm/min (software-controlled, infinitely variable) |
| Stroke | 1000 mm |
| Displacement Resolution | 0.01 mm |
| Clamp Width (standard) | 30 mm |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 300 W |
| Dimensions (L×W×H) | 380 × 450 × 1309 mm |
| Net Weight | 92 kg |
| Accuracy Class | Better than Grade 0.5 |
| Compliance Standards | GB/T 3923.1–2013, GB/T 17200, ISO 37, ASTM D882, ASTM D1938, ASTM F88, EN ISO 11600, JIS P8113 |