Karl Fischer Moisture Analyzer
Filter
Showing 1–30 of 44 results
| Brand | Aboni |
|---|---|
| Origin | Germany |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Sample Form | Solids, Powders, Films |
| Measuring Principle | Hydride-Generation Gas Evolution (CaH₂ Reaction) |
| Absolute Range | 0.2–30 mg H₂O |
| Relative Range | 0.0005–5 % w/w |
| Reproducibility | ±0.1 mg H₂O (at 1 mg), ±0.3 mg H₂O (at 20 mg) |
| Sample Weight | 0.01–50 g (up to 100 g, density-dependent) |
| Sample Volume | ~50 cm³ |
| Test Temperature | 50–210 °C (1 °C increments) |
| Ambient Air Monitoring | Temp (0.1 °C), RH (0.1 %), Pressure (1 mbar) |
| Reagent | Calcium Hydride (CaH₂) powder (~0.1 g/test) |
| Power Supply | 100/115/230 VAC |
| Dimensions | 285 × 170 × 250 mm (H×W×D) |
| Weight | 4.6 kg |
| Interface | Bidirectional RS-232 |
| PC Requirements | Windows® 98/ME/2000/NT/XP with RS-232 or USB (via adapter) |
| Compliance | ISO 15512 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | AQV-2200 |
| Pricing | Upon Request |
| Brand | BenAng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.1 ppm |
| Moisture Content Range | 0.00001% (0.1 ppm) to 100% |
| Measurement Accuracy | ±0.1 ppm |
| Minimum Dispensing Volume | 0.5 µL |
| Titration Control Precision | ±0.1 mV |
| Repeatability | ≤0.0002% RSD |
| Linearity Correlation Coefficient | ≥0.9999 |
| Power Consumption | <50 W |
| Operating Voltage | AC 220 V ±10%, 50 Hz |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity Limit | ≤85% RH (non-condensing) |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Model | ZDJ-2S |
| Titration Mode | Fully Automated |
| Method Type | Dual-Mode (Coulometric & Volumetric Karl Fischer) |
| Measurement Resolution | 0.01 μA |
| Water Content Range | 0.01 mg to 100% w/w |
| Accuracy | ≤0.3% RSD |
| Minimum Dispensing Increment | 1/2000 of burette volume |
| Titration Control Precision | 0.1 μA |
| Drift Compensation | Automatic background drift correction (drift <5 µg H₂O/min) |
| Detection Limit | 0.01 mg H₂O |
| Sample Forms | Liquids, solids, gases, pastes |
| Display & Interface | Bilingual (Chinese/English) LCD with real-time titration curve visualization |
| Data Output | GLP/GMP-compliant report formats (%, ppm, mg), statistical analysis capability |
| Software | Embedded titration monitoring software with firmware upgrade support |
| Compliance | Designed for ISO 8533, ASTM E203, USP <921>, and EP 2.5.12 environments |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Model | ZDJ-3S |
| Titration Mode | Fully Automatic |
| Method Principle | Volumetric & Coulometric Karl Fischer Titration |
| Current Resolution | 0.01 µA |
| Moisture Range | 10 ppm to 100% w/w |
| Measurement Accuracy | ±10 ppm |
| Minimum Dispensing Volume | 0.1 µL (1/20000 of burette volume) |
| Titration Control Precision | 0.1 µL |
| Polarization Voltage Output | 0–2550 mV (10 mV step, <±3% error) |
| Max Polarization Current | 5 mA |
| Current Range | 0–200 µA |
| Effective Current Accuracy | ±0.1 µA |
| Drift Compensation | Auto/manual background subtraction |
| Data Output Compliance | GLP/GMP-compliant reporting format |
| Interface | RS-232C (printer & PC connection) |
| Method Storage | 100 protocols |
| Optional | Dead-stop titration capability with accessory kit |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZDJ-600S |
| Titration Method | Fully Automated Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Current Resolution | 0.01 µA |
| Moisture Range | 10 ppm to 100% w/w |
| Measurement Accuracy | ≤0.2% RSD |
| Minimum Dispensing Volume | 5 µL |
| Burette Precision | 1/20,000 |
| Burette Capacity | 10 mL (standard) |
| Burette Accuracy | ±10 µL @ 10 mL |
| Polarization Current Range | 0–200 µA |
| Polarization Voltage Range | 0–2550 mV |
| Polarization Voltage Step | 10 mV |
| Effective Current Accuracy | Better than ±0.1 µA |
| Repeatability (Pure Water) | <1% RSD |
| Standardization Repeatability | ±0.5% of mean across three consecutive runs |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | AKF-V6 |
| Pricing | USD 6,800 (FOB Shanghai) |
| Titration Mode | Fully Automated Volumetric Titration |
| Instrument Type | Dual-Mode Karl Fischer Analyzer (Volumetric & Coulometric Capable via Optional Module) |
| Measurement Resolution | 0.1 ppm |
| Water Content Range | 10 ppm – 100% (0.001% – 100% H₂O) |
| Accuracy | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (with 20 mL burette) |
| Repeatability | ≤ 0.3% RSD |
| Linearity Correlation Coefficient | ≥ 0.999 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette Options | 20 mL / 10 mL |
| Titration Control Precision | ±0.5 µL (20 mL burette) |
| Power Supply | 110–240 V AC, 50–65 Hz |
| Data Storage Capacity | 200 test records (expandable via USB export) |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 0.001% (10 ppm) to 100% |
| Power Supply | AC 220 V ±10%, 50 Hz ±2.5 Hz |
| Data Storage | Automatic storage of up to 1,000 test records |
| Brand | Leichi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | SFK-506V |
| Titration Method | Fully Automated Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Moisture Measurement Range | 100 µg – 250.0 mg |
| Measurement Resolution | 1 µg |
| Repeatability | ≤0.3% |
| Potentiometric Range | 0–2000 mV |
| Potentiometric Resolution | 0.1 mV |
| Polarization Current Range | 1–200 µA |
| Polarization Current Accuracy | ±3% |
| Polarization Current Stability | ±2.5% / 30 min |
| Power Supply | 80–305 VAC, 47–63 Hz |
| Dimensions (W×D×H) | 240 × 370 × 270 mm |
| Weight | ~4 kg |
| Data Storage Capacity | 2000 test records |
| Communication Interfaces | RS-232, USB (for balance, barcode scanner, heating oven), WLAN/WiFi |
| Output Options | PDF report export, thermal/USB printer support, U-disk data export |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | KLS-411 |
| Pricing Range | USD 570 – 2,850 (based on current exchange rate ~¥4000–¥20,000) |
| Titration Mode | Fully Automated Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Moisture Measurement Range | 10 µg to 20 mg |
| Measurement Accuracy | ≤ ±3% RSD |
| Electrolysis Current Settings | 10 mA, 20 mA, 50 mA, 100 mA |
| Polarization Current Error | ±0.2 µA |
| Electrolysis Current Basic Error | ±0.5% of reading |
| Indication Error | ±(5% of calibration point + 3) µg |
| Repeatability | ≤3% RSD |
| Power Supply | (220 ± 22) V AC, (50 ± 1) Hz |
| Dimensions (L×W×H) | 300 × 235 × 100 mm |
| Net Weight | 3 kg |
| Interface | RS-232 serial port for printer connectivity |
| Electrode Configuration | Membrane-type dual-platinum electrode |
| Reagent Compatibility | Leici low-toxicity, low-odor, reusable KF reagent (coulometric anolyte/catholyte system) |
| Reagent Standardization | Not required (pre-calibrated reagent system) |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Method | Fully Automatic |
| Moisture Measurement Range | 10.0 µg – 200 mg |
| Resolution | 0.1 µg |
| Repeatability | ≤1% |
| Electrolysis Current Stability | ±0.2% / 10 min |
| Polarization Current Error | ±3% |
| Polarization Current Stability | ±2.5% / 30 min |
| Potential Measurement Range | 0–2000 mV |
| Potential Resolution | 0.1 mV |
| Power Supply | 100–240 VAC, 47–63 Hz |
| Dimensions (L×W×H) | 240 × 370 × 270 mm |
| Weight | ~3 kg |
| Data Storage Capacity | 200 measurement records |
| Interface Support | RS-232 (printer), USB (scanner, moisture control software, U-disk export), optional KF oven coupling |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Measurement Range | 0.1–250.0 mg |
| Resolution | 1 µg |
| Accuracy | ±7% |
| Repeatability | ≤0.5% (for samples containing >10 mg water) |
| Titration Mode | Fully Automatic |
| Electrode Potential Range | 0–2000 mV |
| Potential Resolution | 1 mV |
| Polarization Current Error | ±3% |
| Polarization Current Stability | ±2.5% over 30 min |
| Power Supply | 80–305 VAC, 47–63 Hz |
| Dimensions (W×D×H) | 240 × 370 × 270 mm |
| Weight | ~4 kg |
| Data Storage Capacity | 200 methods/results |
| Interface | RS-232, USB, U-disk export support |
| Compliance | GLP-compliant data traceability, multi-level user authentication |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Range | 3.0 µg – 200 mg H₂O |
| Resolution | 0.1 µg |
| Repeatability | ≤0.3% |
| Titration Method | Fully Automated Coulometric Titration |
| Dimensions (L×W×H) | 240 mm × 370 mm × 270 mm |
| Weight | ~4 kg |
| Power Supply | 100–240 VAC, 47–63 Hz |
| Electrolysis Current Accuracy | ±0.5% |
| Electrolysis Current Stability | ±0.2%/10 min |
| Polarization Current Range | 1–200 µA |
| Polarization Current Error | ±3% |
| Polarization Current Stability | ±2.5%/30 min |
| Potential Measurement Range | 0–2000 mV |
| Potential Resolution | 0.1 mV |
| Data Storage Capacity | 2000 test records |
| Connectivity | RS-232, USB (for balance, barcode scanner, printer), WLAN/WiFi, U disk export |
| Compliance | GLP-compliant architecture, GMP-ready audit trail, 21 CFR Part 11–compatible data management framework |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | SFK-506VC |
| Pricing | ¥88,900 CNY |
| Titration Mode | Fully Automated |
| Instrument Type | Volumetric & Coulometric Karl Fischer Moisture Analyzer |
| Moisture Measurement Range | 3.0 μg – 200 mg (Coulometric), 100 μg – 250.0 mg (Volumetric) |
| Resolution | 0.1 μg (Coulometric), 1 μg (Volumetric) |
| Accuracy | ±0.3% |
| Repeatability | ≤0.3% |
| Polarization Current Range | (1–200) μA |
| Titration Control Precision | 0.1 μg |
| Power Supply | 100–240 VAC, 47–63 Hz |
| Data Storage | 2000 records per method (volumetric & coulometric) |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | ZDY-501 |
| Pricing Range | USD 570 – 2,850 |
| Titration Mode | Fully Automatic |
| Method Type | Volumetric and Coulometric Karl Fischer |
| Moisture Measurement Range | 0.1 mg – 250 mg |
| Measurement Accuracy | ±3% |
| Polarization Current | 1 µA |
| Endpoint Detection Range | 40–120 mV |
| Sample Temperature Range | 5–30 °C |
| Dimensions (L×W×H) | 280 × 210 × 120 mm |
| Weight | 5 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | ZDY-504 |
| Pricing | USD 5,300 (FOB Shanghai) |
| Titration Mode | Fully Automatic |
| Instrument Type | Volumetric & Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 mg |
| Moisture Content Range | Volumetric: 0.1–250.0 mg H₂O |
| Coulometric | 10 µg–20 mg H₂O |
| Accuracy | Volumetric: ≤0.5% RSD |
| Coulometric | ≤3% RSD at 100 µg H₂O |
| Minimum Dispensing Volume | 0.005 mL |
| Repeatability | Volumetric: ≤0.5% RSD |
| Coulometric | ≤3% RSD at 100 µg H₂O |
| Polarization Current Settings | 10.722 mA, 20 mA, 53.61 mA, 107.22 mA |
| Burette Capacity | 10 mL |
| Titration Control Precision | 1/12,000 |
| Power Supply | (220 ± 22) V AC, (50 ± 1) Hz |
| Data Storage Capacity | 200 measurement records |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Type | Coulometric Karl Fischer Moisture Analyzer |
| Model | 851 |
| Titration Mode | Fully Automated |
| Water Content Range | 10 µg – 200 mg H₂O |
| Measurement Accuracy | ±0.2 mV |
| Minimum Dispensing Volume | 10 µL |
| Automation Interface | MSB (Multi-Sample Bus) compatible |
| Bromine Number Capability | Yes, using same electrode set and cell |
| Software Control Options | Built-in touchscreen or Tiamo™ PC-based software |
| Sample Handling Integration | Compatible with 814/815 USB Sample Processors and 874 Oven Sampler |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 852 |
| Titration Mode | Fully Automated |
| Instrument Type | Dual-Mode Karl Fischer Titrator (Coulometric & Volumetric) |
| Software Control | tiamo™ |
| Sample Handling Options | Compatible with 814/815 USB Sample Processors and 874 Oven Sample Heater |
| Bromine Number Analysis Capability | Yes, using same electrode set and titration cell with solvent exchange |
| Reagent Exchange Automation | Supported via MSB interface with Dosino or Multi-dosing Units |
| User Interface | Optional 7-inch TFT Touchscreen or PC-based tiamo™ Workstation |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Type | Imported Instrument |
| Model | 860 |
| Temperature Range | 50–250 °C |
| Temperature Accuracy | ±3 °C |
| Heating Rate | 15 °C/min (80–180 °C, 230 V) |
| Cooling Rate | 9 °C/min (80–180 °C, 230 V) |
| Carrier Gas Flow Range | 0–300 mL/min (standard conditions) |
| Compatible With | Volumetric and Coulometric Karl Fischer Titrators |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 885 |
| Titration Mode | Fully Automated |
| Instrument Type | Volumetric Karl Fischer Titrator with Integrated Headspace Heater |
| Sample Handling | Headspace vial-based, non-contact sample introduction |
| Compliance | Designed for GLP/GMP environments, supports 21 CFR Part 11–compliant software modules (when paired with OMNIS platform) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Data Storage | Internal instrument memory + optional networked database via OMNIS Software |
| Environmental Operating Conditions | 10–40 °C, 20–80% RH (non-condensing) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Type | Volumetric Karl Fischer Titrator |
| Model | 890 |
| Titration Mode | Fully Automatic |
| Measurement Principle | Coulometric & Volumetric KF (Volumetric mode enabled) |
| Current Range | –120 to +120 µA |
| Potential Accuracy | ±0.2 mV |
| Minimum Dispensing Volume | 10 µL |
| Electrode Polarization Control | Adjustable Pol/Upol modes |
| Safety Features | Safety Stop function, integrated membrane pump, anti-overflow waste system |
| Sealing Performance | Ultra-low drift design |
| Interface Standards | MSB bus, USB 2.0, RS-232, Ethernet (LAN/LIMS/Intranet capable) |
| Software | tiamo™ PC software (multi-instrument control, audit trail, FDA 21 CFR Part 11 compliant), built-in color touchscreen with method storage (300–500 methods + curves) |
| Compliance | Fully compliant with ISO 8533, ASTM E203, USP <921>, EP 2.5.12, JP 2.07, GLP/GMP, and FDA 21 CFR Part 11 (electronic records & signatures) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Titration Mode | Fully Automatic |
| Moisture Measurement Range | 10 µg – 200 mg (up to 1000 mg max) |
| Accuracy | ±3 µg (for 10–1000 µg H₂O), ±0.3% (for ≥1000 µg H₂O) |
| Electrolysis Rate | 2240 µg H₂O/min |
| Pre-stored Methods | 3 |
| User-Defined Methods | 100 |
| Operator/Expert Mode Switching | Yes |
| Sample Detection & Auto-Start | Yes |
| Integrated Magnetic Stirring | Yes |
| External Stirrer Support | One 801 or 803 stirrer |
| Connectivity | 1 × USB port, RS-232/USB converter (optional) |
| Power Supply | External AC adapter or rechargeable power pack (optional) |
| Dimensions (W×H×D, without titration cell shield) | 144 × 112 × 282 mm |
| Compliance | ASTM E1064-2008, ASTM D4928-00(2010), ASTM D6304-2007, ISO 15512, ISO 10337-1997, GB/T 6283-2008, GB/T 11146-2009, GB/T 3727-2003, GB/T 5074-1985, GB/T 6023-2008, GB/T 7376-2008, GB/T 7600-1987, GB/T 18619.1-2002, GB/T 18826-2002, SH/T 0246-1992, SH/T 0255-1992, Chinese Pharmacopoeia General Method 0832 (Karl Fischer) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 901 |
| Titration Mode | Fully Automatic Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Measurement Range | ppm to 100% |
| Measurement Accuracy | ±0.2 mV, ±0.02 µA |
| Minimum Dispensing Volume | 10 µL |
| Interface Options | USB, RS-232, Remote I/O |
| Compliance | FDA 21 CFR Part 11 |
| Software Platform | tiamo™ |
| Sample Automation Compatibility | Titrando system with USB Sample Processor, 860 Oven Sampler, or 874 Oven Autosampler |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Type | Imported Instrument |
| Model | 915 KF Ti-Touch |
| Titration Mode | Fully Automated |
| Method Principle | Volumetric and Coulometric Karl Fischer Titration |
| Moisture Range | 10 ppm to 100% w/w |
| Measurement Accuracy | ±0.2 mV |
| Minimum Dispensing Increment | 1/10,000 of Burette Volume |
| Dual-Channel Expandability | Yes (via 2 MSB ports) |
| Sample Processor Compatibility | 814/815 Sample Changers |
| Data Output | PDF Report (anti-counterfeit, timestamped, digitally signed), USB storage, network/LIMS integration |
| Safety Features | Auto-stop volume limit, electrode fault detection, reagent-handling isolation via Dosino |
| User Interface | 7″ capacitive touchscreen with 14 customizable method shortcuts |
| Software Integration | tiBase data management platform |
| Compliance Support | GLP/GMP-ready audit trail, 21 CFR Part 11–compatible reporting (when used with tiBase and networked environment) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automated |
| Water Content Range | 10 µg – 200 mg (up to 1000 mg max) |
| Accuracy | ±0.3% (for H₂O ≥ 1000 µg) |
| Electrolysis Rate | up to 2241 µg H₂O/min |
| Generator Current Settings | 100, 200, 400 mA or Auto |
| Indicator Electrode Polarization Current | AC: 5, 10, 20, 30 µA |
| DC | –125…+125 µA |
| Indicator Electrode Potential Resolution | 0.1 mV |
| Bromine Number/Bromine Index Mode | Yes |
| Integrated Peristaltic Pump | Yes |
| USB Ports | 2 (for printer, keyboard, barcode scanner, storage) |
| Network Interface | Yes (LIMS, network printing, remote data archiving) |
| Touchscreen | 90 mm × 120 mm color display with real-time titration curve |
| Method & Result Storage | Internal database + USB export (PDF, CSV) |
| Language Support | English, French, German, Spanish, Chinese |
| Quick-Access Icons | 14 customizable |
| Operator/Expert Mode | Yes |
| Drift Correction | Manual/Auto/Off |
| Re-calculation & Custom Formula Support | Yes |
| Sample Heating Compatibility | Optional 860 (single-position) or 885 (18-position) KF Oven |
| Compliance | Designed for GLP/GMP environments |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Measurement Range | 10 µg – 200 mg H₂O |
| Accuracy | ±0.3% |
| Titration Mode | Fully Automatic Coulometric Titration |
| Sample Introduction | Direct liquid injection or optional oven coupling (e.g., 885 Compact Oven) |
| Compliance | Designed for GLP/GMP environments |
| Data Integrity | Audit-trail ready configuration available |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Automation Level | Fully Automated Titration |
| Moisture Range | 10 ppm to 100% (w/w) |
| Minimum Burette Delivery | 1/20,000 of burette volume |
| User Methods | 120 preconfigured methods |
| Display | Multilingual capacitive touchscreen (Chinese included) |
| Data Export | PDF reports via USB flash drive |
| Operating Modes | Expert Mode & Routine Mode with password protection |
| Solvent Handling | Integrated solvent pump for safe, contact-free reagent dispensing and burette filling/emptying |
| GLP Compliance | Audit-trail-ready reporting, electronic signature support, and traceable method execution |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Type | Volumetric Karl Fischer Titrator |
| Titration Mode | Fully Automated |
| Measurement Range | –2400 to +2400 mV |
| Accuracy | ±3 µg (for 10–1000 µg water) |
| Minimum Dispense Volume | 10 µg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Model | C20S / C30S |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.1 mV |
| Water Content Range | 10 µg – 200 mg H₂O |
| Accuracy | ±0.3% (for samples containing >1 mg H₂O) |
| Minimum Charge Delivery | 0.1 mC |
| Titration Control Precision | 0.1 mC |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automated |
| Measurement Resolution | 0.1 mV |
| Water Content Range | 10 µg – 200 mg H₂O |
| Accuracy | ±0.3% (for samples containing >1 mg H₂O) |
| Minimum Dosing Increment | 0.1 mC |
| Titration Control Precision | 0.1 mC |