Laboratory Supporting Equipment
Filter
Showing all 14 results
| Brand | Airs |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | Airs |
| Pricing | Available Upon Request |
| Brand | Airs |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TA600 |
| Pricing | Available Upon Request |
| Brand | Airs |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TA900 |
| Pricing | Available Upon Request |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | BAT600-AR / BAT800-AR / BAT1000-AR / BAT1250-AR / BAT1700-AR / BAT2000-AR |
| Temperature Range | 5–45°C (dark), 10–45°C (with lighting) |
| Humidity Range | 40–80% RH (light on), 50–90% RH (light off) @ 15–45°C |
| Temp. Uniformity | ±0.5°C (per shelf level) |
| Temp. Control Accuracy | ±0.1°C |
| Humidity Control Accuracy | ±1% RH |
| Humidity Fluctuation | ±3% RH |
| Photosynthetic Photon Flux Density (PPFD) | 0–400 µmol/m²/s (0–100% dimmable, measured at 100 mm from lamp) |
| Air Exchange Rate | up to 0.57 m³/min |
| Programmable Stages | 24-segment time-based scheduling with real-time Beijing time sync |
| Control System | BAT200PG OS, 7-inch color touchscreen interface |
| Cooling Method | Hot-gas bypass refrigeration |
| Defrost Mode | Solenoid-valve controlled automatic defrost |
| Safety Protections | Compressor overheat, fan overheat, overtemperature, high-pressure cutout, overload protection |
| Data Logging | Internal storage for ≥5 years of operational records |
| User Access Levels | Four-tier password management (Factory Admin, User Admin, Operator Template, Engineer Template) |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | BAT600-PG / BAT800-PG / BAT1000-PG / BAT1250-PG / BAT1700-PG / BAT2000-PG |
| Temperature Range | 5–45°C (dark), 10–45°C (with lighting) |
| Humidity Range | 40–80% RH (light on), 50–90% RH (light off) @ 15–45°C |
| Temp Uniformity | ±0.5°C (per shelf) |
| Temp Accuracy | ±0.1°C |
| Humidity Accuracy | ±1% RH |
| Humidity Fluctuation | ±3% RH (per shelf) |
| Photosynthetic Photon Flux Density (PPFD) | 0–600 µmol/m²/s (0–100% dimmable, measured at 100 mm from lamp) |
| Optional Upgrades | CO₂ control module, multi-spectral LED lighting (up to 800 µmol/m²/s), closed-loop dimming system, remote monitoring interface |
| Brand | Boante |
|---|---|
| Model Series | BAT700-FS, BAT800-FS, BAT1000-FS, BAT1100-FS, BAT1200-FS |
| Construction Material | 0.6–1.0 mm stainless steel (AISI 304 equivalent) |
| Layer Count | 7–12 |
| Dimensions (W×D×H) | 140 × 145 × 400 mm to 140 × 145 × 700 mm |
| Compatible Storage Box Size | 133 × 133 × 54 mm (standard) |
| Capacity per Layer | 7–12 boxes (81-well paper or 100-well plastic cryoboxes) |
| Surface Finish | Smooth deburred edges, electropolished weld zones |
| Compliance | Designed for long-term operation at –80 °C and –196 °C (liquid nitrogen vapor phase) |
| Warranty | 12-month limited warranty covering material and workmanship defects under normal cryogenic use |
| Brand | Boante |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | Upon Request |
| Photosynthetic Photon Flux Density (PPFD) at 150 cm | 500 μmol/m²/s |
| Spectral Range | 400–780 nm (continuous) |
| LED Channel Ratio (Red | Blue:White:Far-Red): 4:2:2:2 |
| Spectral Stability | ≤ ±5% fluctuation per channel |
| Rated LED Lifetime | ≥ 50,000 hours |
| Thermal Management | Automatic active cooling system |
| Brand | Boante |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| CO₂ Control Range (M-type) | Ambient +100 ppm to 2000 ppm |
| CO₂ Control Range (MD-type) | 180 ppm to 2000 ppm (customizable) |
| CO₂ Detection Accuracy | ±1 ppm |
| CO₂ Control Accuracy | ±3% of setpoint |
| CO₂ Sensor Technology | NDIR with Vaisala CARBOCAP® module |
| Response Time (0→2000 ppm) | ≤5 s |
| Concentration Step Response Time (100 ppm step) | 15 s |
| CO₂ Output Channels | 2 or 3 |
| Air Output Channels | 2 or 3 |
| Gas Flow Range (CO₂) | 0.16–1.6 L/min (optional high-flow: 0.4–6 L/min) |
| Pump Type | Oil-free DC diaphragm pump |
| Flow Stability | ±0.3% FS |
| Noise Level | ≤42 dB(A) |
| Chamber Material | Stainless steel with corrosion-resistant coating |
| Calibration Interval | 12 months |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Temperature | 10–30 °C |
| Compatible Media | Freshwater, synthetic seawater, low-salinity and high-salinity seawater (≤45‰) |
| Control Interface | 7-inch capacitive touchscreen |
| Control Algorithm | Adaptive PID + fuzzy logic |
| Data Logging | Real-time timestamped gradient tracking with power-loss recovery |
| Brand | Boante |
|---|---|
| Model Range | SC801M, SC802M, SC803M, SC804M, SC806M, SC801MD, SC802MD, SC803MD, SC804MD, SC806MD |
| Control Interface | 7-inch TFT touch screen |
| CO₂ Concentration Range (M) | Ambient +100 ppm to 2000 ppm |
| CO₂ Concentration Range (MD) | 180 ppm to 2000 ppm (customizable) |
| Detection Accuracy | ±1 ppm |
| Control Accuracy | ±3% of setpoint |
| Sensor Type | NDIR infrared with Vaisala CARBOCAP® module |
| Response Time (Detection) | ≤5 s (0→2000 ppm step) |
| Concentration Adjustment Response Time | 15 s (100 ppm step) |
| CO₂ Flow Rate Range | 0.16–1.6 L/min (standard) |
| optional high-flow | 0.4–6 L/min |
| Air Flow Regulation | Yes |
| Number of CO₂ Output Channels | 1, 2, 3, 4, or 6 |
| Air Output Channels | 1 |
| Pump Type | Oil-free DC diaphragm pump |
| Flow Stability | ±0.3% FS |
| Noise Level | ≤42 dB(A) |
| Enclosure Material | Stainless steel with corrosion-resistant white coating |
| Operating Temperature | 10–30 °C |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | 100–220 W (model-dependent) |
| Calibration Interval | 12 months |
| Water Compatibility | Freshwater, synthetic media, low-salinity seawater, high-salinity seawater (≤45‰) |
| Control Algorithm | Adaptive PID + fuzzy logic |
| Compliance | Designed for GLP-aligned environmental simulation workflows |
| [Brand | Kingfar |
|---|---|
| Model | ErgoSIM Acoustic Environment Simulation Lab |
| Type | Integrated Human Factors Research Laboratory |
| Core Platform | ErgoLAB Human-Machine-Environment Synchronized Cloud Platform |
| Certification | CE, FCC, RoHS, ISO 9001/14001/OHSAS 18001 |
| Compliance | Supports GLP/GMP-aligned data integrity, 21 CFR Part 11–ready audit trails (via ErgoLAB software), ASTM E336/E1573/E2235 for acoustic perception testing] |
| Brand | Erlab |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Halo Sense Smart |
| Price Range | USD 1,400 – 2,800 |
| Brand | In-situ High-tech |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM Producer |
| Country of Origin | China |
| Model | CIS-XAFS-TFM-PC-T1000 |
| Pricing | Upon Request |
| Brand | Youyunpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YP-FLC |
| Price | USD 3,750 (approx.) |
| Compliance | GB/T 4633–2014, GB/T 3558–2014 |
| Detection Principle | High-Temperature Combustion Hydrolysis coupled with Ion-Selective Electrode (F⁻) and Potentiometric Titration (Cl⁻) |
| Sample Mass | ~0.5 g |
| Oxygen Requirement | Oil-free, moisture-free, ≥99.5% purity |
| Decomposition Time | 30 min |
| Analysis Time | 20 min |
| Furnace Temperature Control Accuracy | 1100 ± 1 °C |
| Total Power Consumption | 4 kW |
| Input Power | AC 220 V ±10%, 50 Hz, 20 A |