Laser Confocal Microscope
Filter
Showing all 19 results
| Brand | Abner |
|---|---|
| Origin | Jiangsu, China |
| Model | ABN-3DLCM-001 |
| Instrument Type | Point-Scanning Confocal Microscope |
| Resolution (X-Y) | ≤200 nm |
| Resolution (Z) | ≤500 nm |
| Laser Sources | Optional Multi-Wavelength Lasers |
| Detectors | PMT or Multi-Channel Photon Counting Detectors |
| Fluorescence Detection | PMT or Multi-Channel Photon Counting Detectors |
| Scanning Mode | XYZ |
| Objective Lenses | 10×, 20×, 50×, 100× |
| Host Computer | Lenovo Workstation |
| Software & Image Workstation | Fully Integrated Automatic Control |
| XY Stage Control | Motorized and Manual Options |
| Brand | Abner |
|---|---|
| Origin | Jiangsu, China |
| Model | ABN-CRM-001 |
| Instrument Type | Point-Scanning Confocal Microscope |
| Lasers | Standard integrated 445 nm, 532 nm, and 633 nm diode lasers |
| Detector | EMCCD sensor with 1600 × 200 or 1600 × 400 pixel array |
| Scanning Module | High-resolution Nikon CCD camera for real-time image display and digital storage |
| Focusing Mechanism | Precise manual adjustment of eyepiece and objective lens to locate micron-scale samples and visually confirm laser focus position on target particles |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | Cytation C10 |
| Resolution | 16-bit |
| Laser Sources | 6-color solid-state lasers |
| Fluorescence Detector | Hamamatsu ORCA-fusion BT sCMOS camera |
| Confocal Module | Spinning-disk confocal |
| Scanning Mode | XYZ motorized stage |
| Optical Zoom | 1.25×–60× |
| Microscope Host | Agilent BioTek |
| Excitation Source | 1000 mW laser system |
| Software & Workstation | Gen5 v3.11+ |
| Vibration-Isolation Platform | 49 cm × 71 cm dedicated optical table |
| Brand | Airy |
|---|---|
| Origin | Beijing, China |
| Model | Nova-SD |
| Lateral Resolution | ~230 nm (theoretical limit: 120 nm) |
| Axial Resolution | ~600 nm (theoretical limit: 450 nm) |
| Laser Lines | 405 nm (1000 mW), 450 nm (1000 mW), 488 nm (1000 mW), 520 nm (1000 mW), 561 nm (1000 mW), 640 nm (1000 mW), 750 nm (1000 mW) |
| Detector Type | Scientific CMOS or EMCCD camera (customizable) |
| Spindle Speed | 7500 RPM |
| Frame Rate | up to 2000 fps (at reduced ROI) |
| Objective | 100× oil immersion (NA ≥ 1.4) |
| Compatible Microscope Frames | Nikon Ti2-E, Olympus IX83, Leica DMi8 |
| Illumination Sources | Same multi-wavelength laser set as excitation |
| Software & Image Workstation | Integrated acquisition and analysis suite |
| Vibration-Isolated Optical Table | Included |
| XY Stage Control | Motorized, precision piezo or stepper-driven |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | BC43 SR |
| Pixel Size | 6.5 µm |
| Resolution | 2040 × 1992 (4.1 MP) |
| Excitation Lasers | 405 nm, 488 nm, 561 nm, 639 nm |
| Scanning Mode | XYZ |
| Objective Lenses | 10×, 20×, 40×, 60×, 100× |
| Software & Workstation | Imaris image analysis software |
| Vibration Isolation | Integrated active/passive damping platform |
| XY Stage Control | Motorized |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Andor Dragonfly |
| Software | Imaris (3D/4D image analysis), Fusion (acquisition & processing) |
| Imaging Modes | Laser Scanning Confocal, Widefield + GPU-Accelerated Deconvolution (ClearView-GPU™), TIRF (chromatically corrected), HILO, SRRF-Stream®, dSTORM, Iterative Deconvolution |
| Max Frame Rate | 400 fps (Dragonfly 200 series) |
| Detector Compatibility | EMCCD and sCMOS cameras |
| Core Technology | Microlens-based parallel confocal scanning head with Borealis™ uniform illumination |
| Brand | attocube Systems AG |
|---|---|
| Origin | Germany |
| Model | attoCFM I |
| Instrument Type | Point-Scanning Confocal Microscope |
| Temperature Range | 1.8 K – 300 K |
| Magnetic Field | Up to 12 T (vector magnet optional) |
| Vacuum Range | 1×10⁻⁶ mbar – 1 atm |
| Numerical Aperture (NA) | 0.82 |
| Optical Resolution | ~550 nm (@635 nm) |
| Coarse Sample Positioning | 5 × 5 × 5 mm³ |
| Fine Scan Range | 30 × 30 µm² @ 4 K |
| Working Distance | 0.7 mm |
| Compatible Cryostats | attoDRY1000/2100, Quantum Design PPMS (1" & 2" bore) |
| Brand | ISS |
|---|---|
| Origin | USA |
| Model | Q2 |
| Fluorescence Lifetime Range | 100 ps – 100 ms |
| Time Resolution | ≤1 ps |
| Counting Rate | 65 MHz/channel |
| Detection Channels | up to 8 |
| Scan Mode | Galvo-based XY scanning (5 kHz) with closed-loop motorized stage |
| Spatial Resolution | configurable from 1×1 to 4096×4096 pixels |
| Frame Rate | up to 20 fps @ 256×256 |
| Spectral Range (detection) | 350–1100 nm & 900–1700 nm |
| Excitation Options | UV–Vis–NIR lasers, supercontinuum source, single- or two-photon excitation |
| Temperature Control | 77 K – 500 K |
| Compliance | GLP/GMP-ready data audit trail, FDA 21 CFR Part 11–compatible software architecture |
| Brand | Lasertec |
|---|---|
| Origin | Japan |
| Model | HYBRID L7 |
| Type | Laser Scanning Confocal Microscope with Hybrid Optical & Interferometric Detection |
| Application Domain | Semiconductor Process Metrology, 3D Surface Topography, Thin-Film Thickness Measurement, Microstructure Inspection |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | TCS SP8 X |
| Excitation Source | Tunable White Light Laser (WLL), Pulsed |
| Detection | Spectral Detection with Adjustable Bandpass, Up to 8 Simultaneous Excitation Lines |
| Fluorescence Lifetime Imaging (FLIM) Capability | Yes |
| Scan Mode | Galvo + Resonant Scanner |
| Zoom Optics | Continuous Spectral Zoom (λ-Zoom) |
| Microscope Frame | Inverted or Upright Configurable Platform |
| Vibration Isolation | Compatible with Active Damping Optical Tables |
| Software | LAS X Professional Suite with Spectral Unmixing, FLIM Analysis, and GLP-Compliant Audit Trail Modules |
| Compliance | Designed for ISO 13485-aligned workflows |
| Brand | Nanolnsights |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | SpinX |
| Pricing | Available Upon Request |
| Resolution | X-Y = 140 nm, Z = 450 nm |
| Excitation Wavelength Range | 400–750 nm |
| Detection Channels | Fluorescence + Brightfield |
| Fluorescence Detector | Scientific CMOS (sCMOS) Camera |
| Objective Lenses | 10×, 20×, 40×, 60×, 100× (oil/water immersion compatible) |
| Microscope Host | Fully Automated Motorized Platform |
| Illumination Source | Metal Halide Lamp / High-Power LED |
| Control Software | Dual-Mode Intelligent Suite (Beginner & Advanced Modes) |
| Vibration Isolation Table | 1.2 × 1.2 m Dedicated Anti-Vibration Platform |
| XY Stage Drive | Precision Motorized Linear Actuation |
| Brand | Nexcope |
|---|---|
| Origin | Zhejiang, China |
| Model | NCF1000 |
| Instrument Type | Point-Scanning Confocal Microscope |
| Field of View | Φ25 mm (25 mm diameter circular field, square imaging area up to 8192 × 8192 pixels) |
| Lasers | 405 nm, 488 nm, 561 nm, 640 nm |
| Detectors | 4-channel PMT (standard), spectral detector (400–750 nm, 1 nm tuning resolution, up to 4 GaAsP PMTs), transmission PMT detector |
| Scan Modes | X, Y, Z, λ (spectral), and T (time-lapse) — fully combinable |
| Pinhole | Motorized continuous adjustment |
| Objective Lenses | 4×/0.16, 10×/0.45, 20×/0.75, 40×/0.95, 60×/1.42, 100×/1.45 & 100×/1.49 (oil immersion, coverslip-corrected) |
| Microscope Host | NIB1000-AT motorized inverted research-grade platform with NIS60 infinity optical system |
| Illumination | Epifluorescence LED light source (4-band, 6-position motorized filter turret: B/G/U standard |
| Software | Nomis Pro X-C (confocal scanning control, multi-dimensional acquisition, channel presets, hardware-integrated operation, 16-bit image output, real-time deconvolution & basic filtering) |
| XY Stage | Motorized grating-based, 130 mm × 100 mm travel, 0.1 µm positioning accuracy, 0.5 µm repeatability |
| Z Focus | Motorized, 10 mm range, 0.02 µm minimum step, 0.1 µm repeatability |
| Adaptive Focus Stabilization (AFS) | Real-time focal plane maintenance during time-lapse imaging |
| Optional Modules | SR-SIM super-resolution upgrade (2D-SIM lateral resolution ≤85 nm, 3D-SIM axial resolution ≤270 nm |
| Brand | PhaseView |
|---|---|
| Country of Origin | France |
| Model | Thunderscan |
| Instrument Type | Point-Scanning Confocal Microscope |
| Z-Axis Scanning Method | Digital Remote Focusing Lens |
| Scan Speed | Up to 100 frames/sec |
| Z-Step Accuracy | ±1% |
| Z-Step Reproducibility | ±0.3% |
| Microscope Compatibility | Universal C-mount video interface (supports brightfield, fluorescence, light-sheet microscopes) |
| Camera Interface | Standard C-mount |
| Included Components | Digital Remote Focus Lens Unit, Real-Time Control Electronics, Thunderscan Acquisition & 3D Processing Software Suite |
| Regulatory Compliance | CE-marked, compliant with IEC 61000-6-3 (EMC), IEC 62471 (Photobiological Safety) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LEXT OLS4500 |
| Pricing | Upon Request |
| Brand | SOPTOP |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CLSM610 |
| Price Range | USD 180,000 – 305,000 |
| Instrument Type | Point-Scanning Confocal Microscope |
| Resolution | 512 × 512 to 4096 × 4096 pixels |
| Lasers | 405 nm / 50 mW, 488 nm / 50 mW, 561 nm / 50 mW, 640 nm / 40 mW |
| Detectors | Multi-channel PMT-based detection system |
| Scanning Module | Dual-axis XY galvanometric optical scanner |
| Scan Speed | Standard: 1 fps (512 × 512, 2 µs pixel dwell) |
| Fast | 3 fps (512 × 512, 0.5 µs pixel dwell) |
| Optical Zoom | 1×–32× continuous scan zoom |
| Objectives | 2×–100× (Achromatic, Apochromatic, and Super-Apochromatic options available) |
| Microscope Host | IRX60 fully motorized inverted fluorescence microscope |
| Illumination | 12 V / 100 W halogen lamp |
| Software & Workstation | Dedicated confocal acquisition and analysis suite |
| XY Stage Control | Motorized, precision-encoded |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Thermo Scientific DXRxi |
| Pricing | Available Upon Request |
| Brand | VibroniX |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LDM |
| Pricing | Available Upon Request |
| Brand | Oxford Instruments |
|---|---|
| Country of Origin | Germany |
| Model | alpha300S |
| Detection Principle | Aperture-type Scanning Near-Field Optical Microscopy (SNOM) |
| Lateral Resolution | ~60 nm |
| Operating Modes | Transmission & Reflection |
| Compatible Detectors | High-sensitivity PMT & APD with overload protection |
| Integrated Spectroscopy | UHTS spectrometer compatible |
| Multimodal Capabilities | Combined AFM, Confocal Microscopy, and SNOM |
| Environmental Operation | Ambient air and liquid environments |
| Sample Preparation | Label-free, non-destructive, minimal preparation required |
| Upgrade Path | Optional integration with confocal Raman and near-field Raman imaging |
| Brand | ZEISS |
|---|---|
| Origin | Germany |
| Model | LSM Lightfield 4D |
| Key Specifications | Excitation Wavelength Range: 405–740 nm |
| Max. Volumetric Acquisition Speed | 80 volumes/s |
| Spatial Resolution (X/Y) | 2.2–8.8 µm (dependent on objective & configuration) |
| Axial Resolution (Z) | 2.8–57 µm (deconvolution-optimized) |
| Voxel Size Range | 0.7×0.7×0.9 µm³ to 2.8×2.8×18 µm³ |
| Z-stack Depth Range | 109–1712 µm |
| Field of View | 20.4 mm |
| Recommended Objectives | C-Apochromat 40×/1.2 W Corr, Plan-Apochromat 40×/1.3 Oil DIC, LD LCI Plan-Apochromat 25×/0.8, Plan-Apochromat 20×/0.8, EC Plan-Neofluar 10×/0.5, among others |
| Compatible Platforms | ZEISS LSM 910 and LSM 990 mounted on Axio Observer stand |
