LCR Meter
Filter
Showing all 5 results
| Brand | Megger |
|---|---|
| Model | MIT525 |
| Test Voltage Range | 250 V to 5 kV (5 preset + user-defined) |
| Max Resistance Measurement | 10 TΩ |
| Short-Circuit Current | 3 mA |
| Accuracy | ±5% up to 1 TΩ, ±20% up to 10 TΩ |
| Display | Backlit LCD with dual-parameter readout |
| Battery | 11.1 V Li-ion, 5.2 Ah, ~6 h continuous operation at 5 kV |
| Charging | AC mains operation during test |
| Safety Rating | CAT IV 600 V, double insulation, IP65 (lid closed) |
| Compliance | IEC 61010-1, IEC 61326-1, IEC 61010-31:2008 (test leads) |
| Dimensions | 315 × 285 × 181 mm |
| Weight | 4.5 kg |
| Data Interface | Isolated USB-B (device mode), compatible with Megger PowerDB Lite |
| Diagnostic Modes | PI, DAR, DD, SV, Ramp Test |
| Voltage Meter Function | 30–660 V ac/dc, ±3% ±3 V |
| Noise Rejection | Up to 3 mA interference suppression |
| Altitude Operation | Rated CAT IV 600 V up to 3000 m |
| Key | Brand: Megger |
|---|---|
| Model | MIT525 |
| Test Voltage Range | 50 V to 5 kV (adjustable in 10 V steps up to 1 kV, 25 V steps above) |
| Maximum Insulation Resistance Measurement | 10 TΩ |
| Short-Circuit Current | 3 mA |
| Display | Backlit LCD with multi-parameter real-time readout (resistance, voltage, leakage current, capacitance, time constant, battery status, elapsed test time) |
| Battery | Rechargeable Li-ion, 6 h continuous operation, 2.5 h full charge |
| Ingress Protection | IP65 |
| Safety Rating | CAT IV 600 V (up to 3000 m altitude) |
| Compliance | IEC 61010-1, IEC 61557-2 |
| Software Compatibility | PowerDB™ analysis software (via USB/RS232) |
| Real-Time Clock & Temperature Logging | Yes |
| Diagnostic Test Modes | IR, IR(t), PI, DAR, DD, SV (Step Voltage), Ramp Test |
| Input Protection | 3 mA noise immunity, ±2% accuracy at 100 MΩ load (500 kΩ leakage protected) |
| Dual-Shell Housing | Outer impact-resistant shell + inner flame-retardant shell |
| Brand | Megger |
|---|---|
| Model | MIT525 |
| Test Voltage Range | 50 V to 5 kV (5 preset + user-defined) |
| Maximum Resistance Measurement | 10 TΩ |
| Accuracy | ±5% up to 1 TΩ at 5 kV |
| Short-Circuit Current | 3 mA |
| Safety Rating | CAT IV 600 V, Double Insulation |
| Ingress Protection | IP65 (enclosure) |
| Operating Altitude | Up to 3000 m |
| Battery | Rechargeable Li-ion, 6 h continuous operation at 5 kV |
| Charging Time | 1.5 h (full charge) |
| Display | Backlit LCD with multi-parameter readout |
| Data Storage | Internal memory with time/date stamping |
| Interface | Isolated USB-B port for PowerDB software integration |
| Compliance | IEC 61010-1, IEC 61010-2-033, IEC 61010-31:2008, IEEE 43, ASTM D257, BS EN 60204-1 |
| Brand | Megger |
|---|---|
| Origin | USA |
| Model | MOM600A |
| Voltage Options | 115 V AC / 230 V AC |
| Output Current Range | 0–600 A DC |
| Resistance Measurement Range | 0–1999 µΩ |
| Resolution | 1 µΩ |
| Accuracy | ±1% of reading + 1 digit (at 100–600 A) |
| Operating Temperature (115 V) | 0°C to +50°C |
| Operating Temperature (230 V) | 0°C to +40°C |
| Storage Temperature | −40°C to +70°C |
| Humidity | 5–95% RH, non-condensing |
| Dimensions (Instrument) | 356 × 203 × 241 mm |
| Weight (115 V unit) | 25 kg |
| Weight (230 V unit) | 24.7 kg |
| Brand | Youyunpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YP-QDZ |
| Price | USD 1,550 (approx.) |