Empowering Scientific Discovery

Lide Biotechnology (Shanghai) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATR
OriginUSA
ModelSuperSPE 360
Automation LevelFully Automatic
Number of Channels6 Independent Channels
Extraction FormatCartridge-Based SPE
Flow Rate Control0.1–60 mL/min
Solvent Reservoirs8
Sample Capacity36 Positions
Sample Volume Range10–20,000 mL
Wetted MaterialsPTFE
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATR
OriginUSA
ModelAutoVap S96
Heating MethodDry Block Heating
Temperature RangeAmbient to 85 °C
Temperature Stability±0.1 °C
Sample Format96-well microplates (standard or deep-well, 8×12 format)
Gas Flow Rate0–60 L/min (0–99 scfh)
Total Sample Capacity192 wells (2 plates)
Heating Power620 W
Dimensions62.2 × 32 × 27.5 cm
Timer Range0–999.9 min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATR
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAutoPro SPE 200
Automation LevelFully Automated
Number of ChannelsDual-Channel (upgradable to 20-channel)
Extraction FormatCartridge-Based SPE
Flow Rate Control0–60 mL/min
Solvent SelectionUp to 8 Pre-Installed Solvents
Sample Capacity2 Samples Simultaneously
Sample Loading Volume1–100 mL (extendable to 1000 mL)
Wetted MaterialsPTFE Only
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATR
OriginUSA
ModelAutoVap S8
Instrument TypeAutomated Quantitative Concentrator
Temperature RangeAmbient to 99°C
Temperature Control Accuracy±0.5°C
Sample Volume Capacity0–50 mL (standard), optional 0–200 mL
Endpoint Detection0.5 mL or 1.0 mL optical sensing
Parallel Channels8 independent channels
Concentration Speed3–5× faster than conventional nitrogen blow-down systems
Sample Recovery Rate≥90% (typical, matrix-dependent)
Endpoint Precision<5% volume error
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATR
OriginUSA
ModelSLE 350
Cooling TechnologySemiconductor-based Condensation
Minimum Operating Temperature−20 °C
Form FactorBenchtop / Fume Hood Compatible
Automation LevelFully Automatic (One-Touch Operation)
Integrated Liquid-Level DetectionYes
CompatibilityUniversal Interface for Rotary Evaporators, Nitrogen Blow-Down Concentrators, and Other Solvent-Generating Instruments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATR
OriginUSA
ModelAutoVap S60
Heating MethodWater Bath
Temperature RangeAmbient to 99 °C
Temperature Stability±0.5 °C
Sample Vial Capacity1.5 mL to 50 mL
Gas Flow Rate0–8 L/min
Sample Positions60
Heating Power800 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATR
OriginUSA
ModelSuper SPE 300
Automation LevelFully Automated
Number of Channels6
SPE Format CompatibilityCartridge and Membrane (25 mm & 47 mm)
Flow Rate Control0.1–60 mL/min (sample pump)
Solvent Reservoirs8 independent solvent ports
Sample CapacityUp to 6 large-volume samples simultaneously
Sample Loading Volume10–20,000 mL
Wetted MaterialsPTFE only
Method ComplianceEPA-approved methods
Control Interface12-inch touchscreen PC with bilingual (English/Chinese) GUI
Waste SegregationThree dedicated waste lines (aqueous, general organic, chlorine-containing organic)
Optional ModuleIntegrated Automated Quantitative Concentration Unit (vortex-assisted nitrogen blow-down, 0–50 mL input, endpoint at 0.5 or 1.0 mL)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATR
OriginUSA
ModelSuper SPE300
Automation LevelFully Automated
Number of Channels6
Cartridge/Membrane CompatibilityUniversal (Columns & Disks)
Flow Rate Control0.1–60 mL/min
Solvent Selection Ports8
Sample CapacityUp to 6 large-volume samples simultaneously
Sample Loading Volume10–20,000 mL
Wetted MaterialsPTFE
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeadTech
OriginCanada
ModelTecta-B16
Detection PrincipleEnzyme-Substrate Fluorescence-Based Optical Sensing
Microbial TargetsTotal Coliforms, Fecal Coliforms, Escherichia coli, Enterococci
Sample Throughput4 or 16 simultaneous assays
Detection Range1–10⁵ CFU/100 mL (no dilution required)
Limit of Detection1 CFU/100 mL
Incubation Temperature Control20–50 °C
Detection Time4–18 h (time-to-detection dependent on concentration)
Data OutputDirect display, Ethernet/Wi-Fi transmission, SMTP email alerts
ComplianceUS EPA Method 1603 & 1604, GB/T 5750.12–2006, ISO 9308-1:2014, ASTM D6502-22
Regulatory ReadinessFDA 21 CFR Part 11–compliant audit trail (software-enabled), GLP/GMP data integrity architecture