| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Auto-Pure20 |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput per Run | 1–20 samples |
| Sample Volume Range | 20–1000 µL |
| Processing Time per Batch | 15–45 minutes |
| Magnetic Rod Count | 20 |
| Magnetic Bead Recovery Rate | >95% |
| Inter-Well CV | <3% |
| Lysis & Elution Temperature Range | Ambient to 90 °C |
| Touchscreen Interface | 7-inch high-resolution color LCD |
| Preloaded Protocols | >100 (15 factory-default) |
| UV Sterilization | Integrated |
| Connectivity | 4× USB-A, 1× USB-B, Ethernet, Wi-Fi, SD card slot |
| Power Supply | AC 110–220 V, 50/60 Hz |
| Dimensions | 440 × 467 × 453 mm |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Auto-Pure32 |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput | 1–32 samples per run |
| Sample Volume Range | 20–1000 µL |
| Processing Time per Run | 15–40 min |
| Magnetic Rod Count | 32 |
| Magnetic Bead Recovery Rate | >95% |
| Inter-Well CV | <3% |
| Lysis & Elution Temperature Range | Ambient to 90 °C |
| Touchscreen Interface | 7-inch high-resolution color LCD |
| Preloaded Protocols | ≥100 (15 factory-default) |
| UV Sterilization | Integrated |
| Connectivity | 4× USB-A, 1× USB-B, Ethernet, Wi-Fi, SD card slot |
| Power Supply | AC 110–220 V, 50/60 Hz |
| Dimensions | 440 × 467 × 453 mm |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Ecos-Gene Automated Nucleic Acid Detection and Analysis System |
| Sample Throughput | 1/2/4 samples per unit (scalable to 16) |
| Fluorescence Channels | 4 (470–510 nm, 530–565 nm, 585–620 nm, 630–665 nm) |
| Thermal Block Temperature Range | Ambient to 120 °C |
| Temperature Accuracy | ±0.2 °C |
| PCR Ramp Rates | ≥6 °C/s (avg. heating), ≥8 °C/s (max. heating), ≥4.5 °C/s (avg. cooling), ≥8 °C/s (max. cooling) |
| Extraction CV | ≤5% |
| Sample Input Volume | Up to 3 mL (working volume ~2.5 mL) |
| Software Platform | Windows-based, LIS- and cloud-database–compatible |
| Compliance | Designed for CLIA-waived and IVD-use environments |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Emos-Gene 600 / Emos-Gene 600A |
| Sample Capacity | 3 × 32-well (0.2 mL for 600 |
| Detection Channels | 6 independent optical channels (C1–C6) |
| Excitation Source | High-power white LED array |
| Detection Sensor | High-sensitivity CMOS imaging system with precision filter wheel |
| Temperature Range | 4 °C to 99.9 °C |
| Temperature Uniformity | ±0.2 °C @ 95 °C |
| Temperature Accuracy | ±0.15 °C |
| Ramp Rate | 4 °C/s (both heating and cooling) |
| Thermal Lid | Auto-adjustable pressure, 30–110 °C |
| Gradient Capability | Single-module gradient control |
| Display | 13.3-inch capacitive touchscreen |
| OS | Windows 10 or later |
| Power Input | 100–240 V~, 50 Hz, 1400 VA |
| Dimensions (D×W×H) | 504 × 360 × 410 mm |
| Weight | 35 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Esan-Gene 696 / Esan-Gene 696A |
| Sample Format | 696 — 0.2 mL tubes & 96-well plates |
| Reaction Volume | 10–100 µL |
| Optical Channels | 6 (F1: FAM/SYBR Green I |
| F2 | HEX/JOE/VIC |
| F3 | ROX/Texas Red |
| F4 | Cy5/Quasar-670 |
| F5 | Cy5.5 |
| F6 | user-definable, default FRET) |
| Dynamic Range | 10⁰–10¹⁰ copies/µL |
| LOD | 1 copy |
| Ct Reproducibility | CV ≤ 1% |
| Temperature Range | 4–99.9 °C |
| Heating Rate | 3.5 °C/s (avg) |
| Cooling Rate | 2.5 °C/s (avg) |
| Block Uniformity | ±0.2 °C @ 95 °C |
| Temperature Accuracy | ±0.15 °C |
| Temperature Precision | 0.1 °C |
| Melting Resolution | 0.1 °C |
| Gradient Range | 1–40 °C across 6 zones |
| Heat Lid Temp | 30–110 °C |
| Display | 10.1″ LVDS capacitive touchscreen |
| Interfaces | USB-A ×3, LAN ×1 |
| Data Export | Excel, PDF |
| Compliance | Designed for GLP-compliant workflows |
| Brand | ALLSHENG |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | FCM-2 |
| Pricing | Available Upon Request |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Feyond-A500 |
| Detection Modes | Absorbance, Fluorescence (Top-Read), Chemiluminescence, Time-Resolved Fluorescence (TRF), Fluorescence Polarization (FP) |
| Wavelength Range (Abs) | 200–1000 nm, 1 nm step |
| Absorbance Range | 0–4 OD |
| Absorbance Accuracy | ±(1.0% + 0.003 OD) at 450 nm (0.0–2.0 OD) |
| Absorbance Precision | CV < 1.0% or SD < 0.003 OD (96-well, precise mode) |
| Read Time (96-well) | <15 s (fast mode) |
| Luminescence Sensitivity | ≤15 amol/plate (ATP assay) |
| Dynamic Range (Luminescence) | 6 decades |
| Fluorescence Sensitivity | ≤1 pM (FITC in 96-well) |
| TRF Sensitivity | ≤0.05 pM (Eu-labeled conjugate) |
| FP Sensitivity | ≤5 mP (standard assay) |
| Excitation/Emission Filter Capacity | 3 pre-installed dual-filter sets (e.g., EX470/EM525), modular & barcode-readable |
| Incubation | PID-controlled, dual-zone (top/bottom), 25–45 °C ±0.5 °C |
| Display | 10-inch motorized rotatable touchscreen (standalone operation) |
| Software | Onboard analysis suite including endpoint, kinetics, spectral scan, standard curve fitting (4PL/5PL), qualitative/quantitative modules, GLP-compliant audit trail (optional PC software: ReaderLT-I) |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Feyond-L100 |
| Detection Principle | Chemiluminescence (PMT-based) |
| Detection Limit | 5 amol ATP per well |
| Linear Dynamic Range | 6 logs |
| Well-to-Well Crosstalk | ≤0.005% |
| Wavelength Range | 200–850 nm |
| Plate Formats | 6–384-well microplates |
| Automation Level | Fully Automated (integrated dispensers) |
| Compliance | GLP-ready architecture, audit-trail capable software (ReaderLT-I), supports 21 CFR Part 11-compliant configurations |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Feyond-MF200 / Feyond-MF280 |
| Absorbance Range | 190–1000 nm (1 nm step) |
| Absorbance Accuracy | ±(1.0% + 0.003 OD) @ 0.0–2.0 OD |
| Absorbance Precision (CV) | <1.0% (standard mode), <0.5% (high-precision mode) |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability (SD) | ≤0.2 nm |
| Spectral Bandwidth (FWHM) | ≤2.5 nm |
| Optical Density Resolution | 0.0001 OD |
| Linear Range (R²) | ≥0.999 @ 0.0–3.0 OD |
| Stray Light | ≤0.1% @ 220 nm |
| Read Time (96-well plate) | <15 s (A1→H1, fast mode) |
| Fluorescence Detection | Top-read mode, Xenon lamp excitation, PMT detection |
| Standard Filter Sets | 470/525 nm, 523/564 nm, 624/692 nm (up to 8 filter positions) |
| Fluorescence LOD | ≤2 pM (96-well black plate, optimized conditions) |
| Dynamic Range | ≥6 decades |
| Plate Compatibility | 6–384-well standard and micro-volume plates |
| Incubation Temperature Range | RT+4°C to 45°C |
| Temp. Uniformity | ≤1.0°C @ 37°C |
| Temp. Accuracy | ±0.5°C @ 37°C |
| Agitation Modes | Linear, orbital, dual-orbital |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | FlexA-200 |
| Detection Principle | Absorbance (UV-Vis) |
| Wavelength Range | 200–1000 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ±0.2 nm |
| Optical System | Grating-based monochromator with 1 nm step resolution |
| Read Range | 0–4.0 OD |
| Bandwidth | <2.5 nm |
| Photometric Accuracy @450 nm | ±(1.0% + 0.003 Abs) for 0–2.0 Abs |
| Photometric Precision @450 nm | CV < 0.5% (precise mode), CV < 1.0% (fast mode) |
| 96-well Plate Read Time | ~8 s (fast), <28 s (precise, endpoint) |
| Temperature Control Range | Ambient +4 °C to 45 °C |
| Temp. Uniformity & Accuracy | ±0.5 °C at 37 °C |
| Detector | Dual silicon photodiodes (sample + reference beam) |
| Display | 10-inch capacitive touchscreen (Android OS) |
| Onboard Storage | 16 GB (≥20,000 assay files) |
| Connectivity | 1× USB-B, 2× USB-A, 1× Ethernet |
| Dimensions (W×D×H) | 300 × 500 × 260 mm |
| Net Weight | 15.5 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | FlexA-200HT |
| Detection Principle | Absorbance (UV-Vis) |
| Wavelength Range | 200–1000 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ±0.2 nm |
| Optical System | Grating-based monochromator, dual-beam with reference channel |
| Spectral Resolution | 1 nm step |
| Absorbance Range | 0–4.0 OD |
| Linearity (at 450 nm) | R ≥ 0.999 [0.0–3.0 Abs] |
| Absorbance Accuracy (at 450 nm) | ±(1.0% + 0.003 Abs) [0–2.0 Abs], ±2.0% [2.0–2.5 Abs] |
| Absorbance Precision (CV) | <0.5% (precise mode), <1.0% (fast mode) |
| 96-well Plate Read Time | ~8 s (fast), <28 s (precise, endpoint) |
| Temperature Control Range | Ambient +4 °C to 45 °C |
| Temp. Uniformity & Accuracy | ±0.5 °C at 37 °C |
| Incubation | Integrated plate and cuvette chamber |
| Vibration | Linear, 3-speed adjustable |
| Detector | Dual silicon photodiodes (sample + reference) |
| Bandwidth | <2.5 nm |
| Light Source | Xenon flash lamp (>1×10⁹ flashes lifetime) |
| Display | 10-inch capacitive touchscreen (Android OS) |
| Onboard Storage | 16 GB (≥20,000 assay records) |
| Connectivity | 2× USB-A, 1× USB-B, 1× Ethernet |
| Dimensions (W×D×H) | 300 × 500 × 260 mm |
| Weight | 15.5 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Leap-Count 100 / Leap-Count 100A |
| Measurement Principle | Brightfield optical imaging with AI-powered image segmentation |
| Cell Diameter Range | 3–60 µm |
| Cell Concentration Range | 1×10⁴–1×10⁹ cells/mL |
| Optimal Concentration Range | 1×10⁵–1×10⁷ cells/mL |
| Viability Detection Range | 0–100% |
| Sample Volume per Chamber | 10 µL |
| Analysis Time (Leap-Count 100) | ≤8 s |
| Analysis Time (Leap-Count 100A) | ≤2 s |
| Imaging Sensor | 6 MP CMOS |
| Objective Magnification | 3× |
| Repeatability (CV) | <5% |
| Storage Capacity | 1 TB (Leap-Count 100), External PC only (Leap-Count 100A) |
| Display | 10.1″ LCD, 1920×1200 (Leap-Count 100), None (Leap-Count 100A) |
| Data Export Formats | PDF, XLS, TIFF, PNG, JPG |
| Operating System | Windows 10 or later |
| Interface | USB 3.2 Gen 2 ×2 + Ethernet (Leap-Count 100) |
| Dimensions (W×D×H) | 260×268×246 mm (flat) / 260×268×376 mm (vertical) (Leap-Count 100) |
| Weight | 6.5 kg (Leap-Count 100), 5.0 kg (Leap-Count 100A) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Leap-Pure S24/H24 |
| Principle | Magnetic Bead-Based Extraction with Pipetting & Magnetic Rod Transfer |
| Sample Throughput | 1–24 samples per run |
| Input Volume Range (S24) | 1–15 mL |
| Input Volume Range (H24) | 1–20 mL |
| Elution Volume Range | 20–200 µL |
| Pipetting Range | 20–1000 µL |
| Pipetting Accuracy | ±8% at 20 µL, ±2% at 100 µL, ±1% at 500/1000 µL |
| Pipetting Precision (CV) | ≤5% across all volumes |
| Temperature Control | 37–120 °C |
| Heating Rate | ≤5 min (40–100 °C, ambient 25 °C) |
| Elution Well Capacity | 20–200 µL |
| Reagent Compatibility | Pre-filled 2/8/15 mL strips (S24), 20 mL strips (H24) |
| Software Platform | Android-based 10-inch touchscreen UI with role-based access control |
| Data Interface | USB, LAN, optional barcode scanner integration |
| Contamination Control | Dual UV lamps, HEPA filtration + active exhaust fan, disposable tip architecture |
| Optional Vision Module | Auto-verification of consumable placement and format |
| Power Supply | AC 220 V, 50 Hz, 450 W |
| Dimensions (W×D×H) | 740 × 586 × 640 mm |
| Weight | 70 kg |
| Brand | Allsheng (Hangzhou) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SealBio-2 Semi-Automatic Microplate Sealer |
| Pricing | Upon Request |
| Heating Temperature Range | 80–200 °C (1.0 °C increment) |
| Temperature Accuracy | ±1.0 °C |
| Temperature Uniformity | ±1.0 °C |
| Sealing Time Range | 0.5–10.0 s (0.1 s increment) |
| Plate Height Detection | Automatic (9–48 mm) |
| Max. Power Input | 300 W |
| Dimensions (D×W×H) | 370 × 178 × 330 mm |
| Weight | 9.6 kg |
| Compatible Plate Materials | PP, PS, PE |
| Compatible Plate Types | Standard ELISA/cell culture plates, 96-well/384-well PCR plates (full-skirted, half-skirted, non-skirted), deep-well storage plates |
| Compatible Sealing Films | Polypropylene foil, PET-PP laminates, transparent polymer films, thin-gauge thermoplastic films, aluminum foil membranes |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TSR-300 |
| Pricing | Upon Request |
| Light Source Wavelength | 525 ± 30 nm |
| Detection Element | Silicon Photocell |
| Sample Width Compatibility | 3–6 mm |
| Minimum Test Line Spacing | 3 mm |
| Detection Output | Qualitative, Semi-quantitative, and Quantitative |
| Data Storage | NAND Flash memory |
| Display | 7-inch high-resolution capacitive touchscreen |
| Interface | Dual USB-A ports, optional Ethernet port |
| Built-in Printer | Thermal mini-printer |
| Power Supply | DC 12–24 V, 2 A (grounded) |
| Power Consumption | ≤ 30 W |
| Dimensions (W × D × H) | 185 × 186 × 97 mm |
| Net Weight | 2.2 kg |
| Shipping Weight | 4.0 kg |
| Operating System | Linux + Qt framework |
| Analysis Algorithms | Linear, Logarithmic, Polynomial curve fitting |
| T/C Ratio CV | ≤1% (T/C > 0.2), ≤2% (T/C ≤ 0.2) |
| Stability CV | ≤3% (T/C > 0.2), ≤5% (T/C ≤ 0.2) |
| Scan Time | < 10 s per strip or cassette |
| Result Validation | Automatic invalid result rejection |
| Brand | Alphavita |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | GDF-529H |
| Instrument Type | Low-Temperature Freezer (≤ –40 °C) |
| Configuration | Upright |
| Effective Volume | 504 L |
| Inner Dimensions (W×D×H) | 649 × 614 × 1262 mm |
| External Dimensions (W×D×H) | 793 × 770 × 1806 mm |
| Power Supply | 220 V AC, 50 Hz |
| Rated Power Consumption | 147 W / 160 W |
| Refrigerant | Hydrocarbon (HC)-based |
| Noise Level | ≤ 40 dB(A) |
| Insulation | VIP Vacuum Insulation Panels |
| Temperature Range | –40 °C to –86 °C (standard operating range |
| Brand | Alphavita |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GDF-549H |
| Instrument Type | Upright Ultra-Low Temperature Freezer (–40 °C to –86 °C operational range) |
| Effective Volume | 504 L |
| Inner Dimensions (W×D×H) | 649 × 614 × 1262 mm |
| External Dimensions (W×D×H) | 793 × 770 × 1806 mm |
| Power Supply | 220 V AC, 50 Hz |
| Refrigerant | Hydrocarbon (R290/R170 blend) |
| Noise Level | ≤40 dB(A) |
| Insulation | VIP Vacuum Insulation Panels + High-Density Polyurethane Foam |
| Door Security | Dual-stage rotary latch with optional padlock interface |
| Power Failure Recovery | Auto-resume of setpoint and alarm status upon power restoration |
| Compliance | Designed per IEC 61000-4 (EMC), GB/T 20154–2014 (Chinese ULT freezer standard), compatible with GLP/GMP environmental monitoring requirements |
| Brand | Alphavita |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | GDF-U780VHE |
| Instrument Type | Upright |
| Effective Volume | 736 L |
| Inner Chamber Dimensions (W×D×H) | 890 × 600 × 1380 mm |
| External Dimensions (W×D×H) | 1030 × 875 × 1990 mm |
| Power Supply | 220 V AC, 50 Hz |
| Rated Power Consumption | 1200 W |
| Refrigeration Technology | Cascade System with Hydrocarbon Refrigerants |
| Door Configuration | Triple or Quadruple Internal Doors (Optional) |
| Insulation | Polyurethane Foam, ≥30 mm Thickness on Inner Door |
| Door Seals | Four-layer立体 (multi-plane) gasket system |
| Safety Features | Expansion tank, password-protected parameter settings, delayed start (0–30 min), external lockable handle |
| Brand | Alphavita |
|---|---|
| Model | GDF-U780VHE |
| Temperature Range | -40°C to -86°C (adjustable in 0.1°C increments, ambient 10–30°C) |
| External Dimensions (W×D×H) | 1030 × 875 × 1990 mm |
| Internal Dimensions (W×D×H) | 890 × 600 × 1380 mm |
| Net Volume | 736 L |
| Net Weight | 312 kg |
| Power Consumption | 1200 W |
| Refrigerant | Hydrocarbon (HC), charge <150 g |
| Door Configuration | Optional triple or quadruple inner doors |
| Control | Delayed start (0–30 min programmable) |
| Insulation | ≥30 mm foamed inner door, quad-layer door gasket system |
| Brand | Alphavita |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MDF-539 |
| Instrument Type | Low-Temperature Freezer (≥ −60 °C) |
| Configuration | Upright |
| Effective Volume | 504 L |
| Internal Dimensions (W×D×H) | 649 × 614 × 1262 mm |
| External Dimensions (W×D×H) | 793 × 770 × 1806 mm |
| Power Supply | Single-phase 220 V / 50 Hz |
| Rated Power Consumption | 312 W |
| Temperature Range | −20 °C to −30 °C (0.1 °C adjustable, ambient 5–30 °C) |
| Net Weight | 154 kg |
| Exterior Material | Powder-Coated Steel |
| Interior Material | Powder-Coated Steel |
| Door Configuration | Dual External Doors with Locking Latches (compatible with padlocks) |
| Compressor | Hermetic Scroll Compressor (400 W output) |
| Refrigerant | R-404A (environmentally compliant blend) |
| Control System | Microprocessor-Based Digital Temperature Controller with Password-Protected LCD Display |
| Safety Features | Dual-Stage Temperature Alarm (high/low), Power Failure Alarm, Sensor Fault Detection (temperature & compressor), Compressor Thermal Protection, Filter Clogging Alert, Built-in Backup Battery for Post-Power-Outage Temperature Readout |
| Standard Accessories | One Set of Keys, Defrost Scraper, Four Nylon Clamps (2× small, 2× large), Adjustable Wire Shelving, Four Casters with Locking Brakes |
| Certifications | CNFDA Medical Device Registration Certificate, ISO 13485:2016, ISO 9001:2015, ISO 14001:2015, OHSAS 18001:2007 |
| Brand | Alphavita |
|---|---|
| Model | MPR-101011 |
| Temperature Range | 2–8°C |
| External Dimensions (W×D×H) | 1210 × 811 × 1990 mm |
| Internal Dimensions (W×D×H) | 1074 × 682 × 1514 mm |
| Net Volume | 1040 L |
| Net Weight | 220 kg |
| Rated Input Power | 370 W |
| Compressor | Imported High-Efficiency Hermetic Compressor |
| Door Configuration | Reversible Hinge, Anti-Collision Limit Stop |
| Insulation | Electrophoretic-Coated Steel Cabinet with Polyurethane Foam (≥60 mm) |
| Door Type | Electrically Heated Double-Glazed Glass Door |
| Control System | Microprocessor-Based PID Controller with Non-Volatile Memory |
| Defrost Method | Intelligent Adaptive Cycle Defrost |
| Airflow Design | Forced-Air Circulation with Optimized Vertical Air Ducts |
| Data Interface | USB Port for Temperature Log Export |
| Lighting | Integrated LED Illumination |
| Security | Mechanical Lock with Tamper-Resistant Housing |
| Drainage | V-Shaped Floor Drain with Self-Cleaning Slope |
| Interior | Rounded Corners, Stainless Steel Shelves with Perimeter Retaining Edges |
| Compliance | Designed to meet ISO 13485 design control principles and IEC 61010-1 safety requirements for medical laboratory equipment |
| Brand | Alphavita |
|---|---|
| Model | MPR-310 |
| Temperature Range | 2–8 °C |
| Effective Volume | 387 L |
| Internal Dimensions (W×D×H) | 570 × 498 × 1405 mm |
| External Dimensions (W×D×H) | 650 × 660 × 1970 mm |
| Net Weight | 126 kg |
| Cooling Method | Forced-air refrigeration with hermetic compressor |
| Refrigerant | R134a |
| Power Supply | 220 V / 50 Hz |
| Rated Input Power | 295 W |
| Temperature Control Resolution | 0.1 °C |
| Temperature Uniformity | ±3 °C (at setpoint 4 °C, ambient 5–35 °C) |
| Safety Alarms | High/Low temperature, door ajar, sensor fault, condenser overheat, condensate blockage, power failure |
| Compliance | ISO 13485, ISO 9001, ISO 14001, OHSAS 18001, China NMPA Medical Device Registration Certificate |
| Brand | Alphavita |
|---|---|
| Origin | Liaoning, China |
| Model | MPR-441FHI |
| Refrigerator Compartment Temperature Range | 2°C to 8°C |
| Freezer Compartment Temperature Range | −20°C to −40°C |
| Refrigerator Net Volume | 218 L |
| Freezer Net Volume | 226 L |
| Overall External Dimensions (W×D×H) | 793 × 770 × 1806 mm |
| Refrigerator Internal Dimensions (W×D×H) | 649 × 566 × 600 mm |
| Freezer Internal Dimensions (W×D×H) | 649 × 614 × 600 mm |
| Rated Input Power | 320 W |
| Net Weight | 175 kg |
| Refrigerants | R600a (refrigerator), R290 (freezer) |
| Temperature Uniformity (refrigerator) | ±1.5°C |
| Control System | Microprocessor-based with real-time compressor status display |
| Data Logging Capacity | 100,000 entries via USB interface |
| Alarm Types | High/Low temperature, door open, power failure, compressor protection, sensor fault, battery life, condenser fan life |
| Brand | Alphavita |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MPR-511 |
| Price | USD 4,700 (FOB) |
| Temperature Range | 2°C to 8°C (ambient 5°C–35°C) |
| Effective Volume | 536 L |
| Internal Dimensions (W×D×H) | 820 × 523 × 1375 mm |
| External Dimensions (W×D×H) | 900 × 668 × 1950 mm |
| Cooling Method | Compressor-based refrigeration |
| Refrigerant | R404A |
| Compressor | Hitachi original imported |
| Power Supply | 220 V / 50 Hz |
| Rated Input Power | 340 W |
| Net Weight | 155 kg |
| Door Configuration | Dual sliding glass doors with heat-reflective film and single mechanical lock |
| Interior Lighting | LED |
| Shelving | 5-tier adjustable wire shelving (10 shelves total) |
| Control System | Microprocessor-based digital controller with 0.1°C resolution, password-protected display, MODBUS RTU communication interface, optional USB data logging |
| Defrost System | Intelligent cyclic defrost with continuous temperature maintenance |
| Fan System | 4 imported DC evaporator fans + 4 imported DC condenser fans |
| Alarm Functions | High/low temperature, door ajar, power failure, compressor fault, sensor failure, battery life warning, fan life monitoring, remote alarm output |
| Additional Features | 32 mm test port (left side), auto-evaporating condensate system, wide-voltage operation (198–242 V), casters with locking mechanism |
| Brand | Alphavita |
|---|---|
| Origin | Liaoning, China |
| Model | MPR-712HI |
| Refrigeration Temperature Range | 2–8°C |
| Effective Volume | 732 L |
| Internal Dimensions | 1120 × 523 × 1375 mm |
| External Dimensions | 1200 × 668 × 1950 mm |
| Refrigerant | R290 (hydrocarbon) |
| Cooling Rate Improvement | 20% vs. fixed-speed baseline |
| Temperature Uniformity | ≤3°C |
| Compressor Type | Inverter-driven, imported unit |
| Door Type | Double-glazed with heat-reflective film |
| Control System | Microprocessor-based non-volatile controller with real-time compressor status display |
| Defrost Method | Intelligent cyclic defrost |
| Data Logging | Up to 100,000 records via USB export |
| Power Consumption Reduction | 67% vs. comparable conventional units |
| Noise Level Reduction | 20% vs. conventional units |
| Brand | Alzet |
|---|---|
| Origin | USA |
| Type | Implantable Osmotic Delivery Device |
| Dimensions | ~19.7 mm × 5.6 mm (cylindrical capsule) |
| Delivery Duration | Up to 28 days (model-dependent) |
| Flow Rate Range | 0.11–10.0 µL/h (varies by model) |
| Reservoir Volume | 100–200 µL (model-dependent) |
| Material Compliance | USP Class VI-certified ethylene-vinyl acetate (EVA) and polyurethane |
| Sterilization | Ethylene oxide (EtO) |
| Biocompatibility | ISO 10993-1 tested |
| Operating Temperature | 37 °C (in vivo) |
| Accuracy | ±10% over specified duration |
| Brand | Cytiva |
|---|---|
| Origin | United Kingdom |
| Model | Amersham DIGE Unit LF24 |
| Gel Dimensions | 255 × 186 × 1 mm |
| External Dimensions | 277 × 217 × 7 mm |
| Max. Simultaneous Gels (Electrophoresis) | 2 |
| Max. Simultaneous Gels (Transfer) | 2 |
| Max. Voltage | 800 V |
| Max. Current | 400 mA |
| Max. Power | 100 W |
| Brand | Advanced MicroFluidics (AMF) |
|---|---|
| Origin | Switzerland |
| Model | AMF-perfusion |
| Automation | Fully Automated |
| Reservoir Capacity | mL-scale |
| Flow Rate Range | 0.25 nL/min – 30 mL/min |
| Syringe Volume Options | 25–1000 µL |
| Valve Types | VD/VFD Series (2–12 ports, PCTFE/PTFE construction) |
| Max Pressure | 7 bar (valves), 5 bar (pump) |
| Dead Volume | As low as 1.5 µL |
| Flow Precision | <1% deviation at full stroke |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 20–80% RH (non-condensing) |
| Certifications | CE, CB |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Amnis |
|---|---|
| Origin | USA |
| Manufacturer | Luminex Corporation (acquired Amnis) |
| Product Type | Imaging Flow Cytometer |
| Model | ImageStreamX Mark II |
| Laser Configuration | Up to 7 lasers (standard: 488 nm, 642 nm, 785 nm |
| optional | 375 nm, 405 nm, 561 nm, 592 nm) |
| Detection Channels | Standard: 6 channels (1 brightfield, 1 darkfield, up to 4 fluorescence) |
| Objective Lenses | Standard 40× |
| Fluorescence Sensitivity | <5 MESF (Molecules of Equivalent Soluble Fluorochrome) |
| Imaging Rate | >1,000 cells/sec |
| Images per Cell | Up to 12 simultaneous high-resolution digital images (including BF, DF, and multiple fluorescence channels) |
| Pixel Resolution | 656 × 494 pixels per image |
| Field of View | ~100 µm × 75 µm per image |
| Sample Volume Range | 20–200 µL per acquisition |
| Brand | AMTK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | B-T |
| Price | USD 70,000 (FOB Beijing) |
| Vacuum Tube Capacity | 5 mL & 10 mL |
| Max. Input Tubes | 24 |
| Output Format | CSV |
| Barcode Support | 1D & 2D (EAN-13, Code 128, QR Code) |
| Operating Temperature | 23 °C ± 5 °C |
| Power Supply | 110/220 VAC, 50/60 Hz |
| Relative Humidity | 10–90% RH (non-condensing) |
| Configuration Options | (A) Tube-to-Scanned EP Tube Rack (≤8 racks × 16 tubes/rack), (B) Tube-to-Microplate (≤9 plate positions), (C) User-Defined Workflow Mapping |