| Brand | A.KRÜSS / A.KRÜSS Optronic |
|---|---|
| Origin | Germany |
| Model | M5000 |
| Temperature Range | 25–400 °C |
| Heating Rate | 1 °C/min |
| Temperature Repeatability | ±0.2 °C |
| Temperature Accuracy | ±0.3 °C (25–200 °C), ±0.5 °C (200–400 °C) |
| Capillary Diameter | 1.4 mm |
| Sample Capacity | 1 capillary per measurement |
| Temperature Resolution | 0.1 °C |
| Cooling | Integrated fan-assisted cooling |
| Safety Rating | IP20 |
| Dimensions (L×W×H) | 230 × 210 × 110 mm |
| Weight | 1.8 kg |
| Power Supply | 85–264 V AC, 47–440 Hz |
| Interface | RS-232 |
| Brand | BM |
|---|---|
| Origin | Shanghai, China |
| Model | WRS-1 |
| Temperature Range | 50–320 °C |
| Heating Rates | 0.2, 0.5, 1.0, 1.5, 2.3, 4.5 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.2 °C/min), ±0.3 °C (at 1.0 °C/min) |
| Temperature Accuracy | ±0.5 °C (<200 °C), ±0.8 °C (≥200 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Temperature Resolution | 0.1 °C |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DRK-R70 |
| Temperature Range | Ambient to 360 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Temperature Accuracy | ±0.3 °C (<250 °C) |
| Capillary Dimensions | Outer Diameter 1.3 mm, Inner Diameter 1.1 mm |
| Temperature Resolution | 0.01 °C |
| Brand | KARG |
|---|---|
| Origin | Germany |
| Model | Kofler HB |
| Type | Hot-block melting point apparatus |
| Principle | Kofler hot-plate method (linear temperature gradient) |
| Application | Rapid qualitative and semi-quantitative melting point determination of organic crystalline solids |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MP55 / MP70 / MP80 / MP90 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Capillary Diameter Compatibility | <1.8 mm |
| Sample Capacity | Up to 6 samples simultaneously |
| Compliance | GLP/GMP-ready, ISO/IEC 17025-aligned calibration traceability |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MP70 / MP90 |
| Temperature Range | RT to 350 °C |
| Heating Rate | 0.1–20 °C/min |
| Sample Capacity | Up to 6 capillaries per run |
| Compliance | USP <741>, Ph. Eur. 2.2.14, JP 17, ISO 11357-3, ASTM D1519 |
| Safety | Integrated optical monitoring with simultaneous transmittance measurement and reflected-light imaging |
| User Interface | One Click® color touchscreen with pre-stored method recall |
| Qualification Support | Factory-supplied IQ/OQ documentation and on-site qualification services available |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FP83/HT |
| Temperature Range | –25 to 375 °C |
| Temperature Accuracy | ±0.2 °C |
| Heating Rate | 0.1–20 °C/min |
| Dropping Point Orifice Diameter | 2.8 mm |
| Softening Point Orifice Diameter | 6.35 mm |
| Compliance | ASTM D3104-82, ASTM D3461-85, ASTM D3954, DIN 51920 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FP900 |
| Temperature Range | −100 to 600 °C |
| Heating/Cooling Rate | 0–20 °C/min |
| Temperature Resolution | 0.1 °C |
| Sensor Type | PT100 |
| Display | Graphical LCD (60 × 256 pixels, 6 lines × 36 characters) |
| Method Storage | 15 preloaded + 35 user-defined methods |
| Compliance | ASTM, DIN, ISO, USP <741>, GLP/GMP-ready |
| Interface | RS232C |
| Measurement Units Support | °C, °F, K |
| Environmental Operating Range | 20–32 °C |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MP55/80 |
| Temperature Range | Ambient to 350 °C |
| Heating Rate | 4 °C/min (programmable) |
| Sample Capacity | 6 positions |
| Measurement Modes | Melting Point (MP), Melting Range (MR), Sliding Melting Point (SMP), Boiling Point (BP), Cloud Point (CP) |
| Video Recording Duration | 60 minutes |
| Maximum Results Storage | 50 entries |
| Compliance | USP <741>, Ph. Eur. 2.2.14, JP 17, ASTM D1565, ISO 4625 |
| Brand | Stanford |
|---|---|
| Origin | USA |
| Model | MPA100 |
| Temperature Range | +10 °C to 400 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.3 °C (@ ~100 °C), ±0.5 °C (@ ~250 °C), ±0.8 °C (@ ~400 °C) |
| Capillary Outer Diameter | 1.4–2.0 mm |
| Temperature Resolution | 0.1 °C |
| Power Supply | AC 90–264 V |
| Weight | 4.1 kg |
| Operating Ambient | 0–40 °C |
| Interface | USB, RS-232 |
| Software | MeltView (Windows-compatible) |
| Brand | YDWG (Shanghai Physical Optics) |
|---|---|
| Origin | Shanghai, China |
| Model | SGW®X-4 |
| Temperature Range | Ambient to 360 °C |
| Heating Rate | Adjustable, up to 320 °C |
| Temperature Repeatability | ±1 °C (<200 °C), ±2 °C (≥200 °C) |
| Temperature Accuracy | ≤±1 °C (<200 °C) |
| Capillary Tube Length | 90 mm |
| Sample Capacity | 1 sample |
| Temperature Resolution | 1 °C |
| Display | LED digital readout (0.1 °C minimum increment) |
| Power Supply | 220 VAC, 50 Hz |
| Power Consumption | 80 W |
| Optical Configuration | Binocular stereomicroscope with 45° inclined dual eyetubes, adjustable interpupillary distance and right-eye diopter compensation |
| Total Magnification | 40× (4× objective + 10× eyepiece) |
| Working Distance | Optimized for thermal stage integration |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW®X-4A |
| Temperature Range | Ambient to 360 °C |
| Heating Rate | 0.5–20 °C/min |
| Temperature Repeatability | ±1 °C (<200 °C), ±2 °C (≥200 °C) |
| Temperature Accuracy | ±0.5 °C |
| Capillary Dimensions | OD Φ1.4 mm, ID Φ0.9 mm |
| Sample Capacity | 3 samples |
| Temperature Resolution | 0.1 °C |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW®X-5 |
| Temperature Range | Ambient to 360 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±1 °C (<200 °C), ±2 °C (≥200 °C) |
| Temperature Accuracy | ±0.5 °C (<200 °C), ±1 °C (≥200 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 0.9 mm |
| Sample Capacity | 3 samples |
| Temperature Resolution | 0.1 °C |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Opti-Melt100 |
| Price | ¥56,500 (CNY) |
| Temperature Range | −10 °C to 400 °C |
| Heating Rate | 0.1–20 °C/min (adjustable in 0.1 °C/min increments) |
| Temperature Repeatability | ±0.3 °C |
| Temperature Accuracy | ±0.3 °C (≤100 °C), ±0.5 °C (≤250 °C), ±0.8 °C (≤400 °C) |
| Capillary Outer Diameter | 1.4–2.0 mm |
| Sample Capacity | 2 capillaries simultaneously |
| Temperature Resolution | 0.1 °C |
| Heating Time | 10 min (50 °C → 350 °C) |
| Cooling Time | 10 min (350 °C → 50 °C) |
| Display | Touchscreen LCD |
| Interface | USB, RS-232 |
| Software | Melt-View™ (Windows-compatible) |
| Power Supply | AC 90–264 V |
| Operating Temperature | 0–40 °C |
| Weight | 4.1 kg |
| Dimensions | 20 × 25 × 21 cm |
| Brand | Zhonglu |
|---|---|
| Model | DS C--500ARD |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Temperature Range | Ambient to 500 °C |
| Heating Rate | 0.1–80 °C/min |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Sample Capacity | 1 |
| DSC Signal Range | 0 to ±200 mW / 0 to ±500 mW |
| Atmosphere Control | Dual-gas auto-switching (N₂/Ar) |
| Display | 10.1-inch 24-bit color industrial touchscreen PC |
| Data Interfaces | USB 2.0, RS-232 |
| Calibration Standards | Indium (In), Tin (Sn), α-Al₂O₃ reference material |
| Compliance | ISO 11357, GB/T 19466, ASTM D3417 |
| Brand | Zhonglu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DSC-500ARD |
| Price | USD 4,200 (approx.) |
| Temperature Range | Ambient to 500 °C |
| Heating Rate | 0.1–80 °C/min |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Sample Capacity | 1 |
| Temperature Resolution | 0.01 °C |
| DSC Signal Range | 0 to ±200 mW / 0 to ±500 mW |
| Atmosphere Control | Dual-gas automatic switching |
| Display | 10.1-inch 24-bit color industrial touchscreen PC |
| Data Interfaces | USB 2.0, RS-232 |
| Calibration Standards | Indium (In) and Tin (Sn), certified reference materials included |
| Compliance | ISO 11357, GB/T 19466, ASTM D3417 |
| Brand | Zhonglu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DSC-500ARD |
| Price | USD 4,200 (approx.) |
| Temperature Range | Ambient to 500 °C ±0.1 °C |
| Heating Rate | 0.1–80 °C/min |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Sample Capacity | 1 |
| Temperature Resolution | 0.01 °C |
| DSC Signal Range | ±200 mW / ±500 mW |
| Atmosphere Control | Dual-gas automatic switching |
| Display | 10.1-inch 24-bit color industrial touchscreen PC |
| Data Interfaces | USB, RS-232 |
| Calibration Standards | Indium and Tin reference materials included |
| Compliance | ISO 11357, GB/T 19466, ASTM D3417 |
| Brand | Zhonglu |
|---|---|
| Model | DSC-500ARD |
| Type | Differential Scanning Calorimeter (DSC) |
| Origin | Shanghai, China |
| Manufacturer | Zhonglu Instrument Co., Ltd. |
| Temperature Range | Ambient to 500 °C |
| Heating Rate | 0.1–80 °C/min |
| Temperature Accuracy | ±0.1 °C |
| Temperature Repeatability | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Sample Capacity | 1 position |
| DSC Signal Range | 0 to ±200 mW / 0 to ±500 mW |
| Atmosphere Control | Dual-gas automatic switching (e.g., N₂/air) |
| Display | 10.1″ industrial-grade capacitive touchscreen (24-bit color) |
| Data Interfaces | USB 2.0, RS-232 |
| Compliance | ISO 11357, GB/T 19466, ASTM D3417 |