Mercury Analyzers
Filter
Showing all 27 results
| Brand | Baode Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Type | Online Mercury Analyzer |
| Model | ARA-7 |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Detection Wavelength | 253.7 nm |
| Sample Matrix | Aqueous environmental and industrial wastewater |
| Compliance | HJ 597–2011 (China), ASTM D3559, ISO 12846 |
| Key Components | Integrated DRA-7 wet digestion module + DRD-7 CVAAS detector |
| Automation Level | Fully automated digestion, reduction, amalgamation, desorption, detection, and cleaning |
| Brand | Baode Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SGM-9 |
| Instrument Type | Portable |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Compliance Standard | JIS B 7994 |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGA-100 |
| Instrument Type | Online Mercury Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Sample Introduction | Solid/Liquid/Gas Direct Injection |
| Analysis Time | <5 min per sample |
| Sample Capacity | 40-position Autosampler |
| Reagent Consumption | Zero chemical reagents required |
| Temperature-Controlled Flow Path | Yes |
| Gold Amalgamation Trap | Nano-coated Au-Hg trap integrated |
| Catalyst System | Dual-stage composite catalyst |
| Exhaust Treatment | Integrated catalytic oxidation + activated carbon adsorption |
| Compliance Framework | Designed for GLP-compliant laboratories |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGM-200 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Detection Limit | ≤0.005 ng |
| Measurement Range | 0–15 ng (long-path absorption cell), 15–200 ng (short-path absorption cell) |
| Sample Throughput | 2.5 min per sample |
| Sample Capacity | 60-position autosampler tray |
| Compliance | ASTM D7623, EPA Method 7473, GB 5009.17-2021, HJ 923-2017, HJ 910-2017, SN/T series, ISO/IEC 17025-aligned operation |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Sample Throughput | 40-position or 120-position Automated Carousel Sampler |
| Integrated Carrier Gas Source | Yes |
| Gold Amalgamation Preconcentration System | Nano-coated Gold Trap |
| Dual-Beam Optical Design | Yes |
| Temperature-Controlled Absorption Cell | Yes |
| Compliance Standards | HJ 597–2011, HJ 543–2009, GB/T 17136–1997, DZ/T 0064.26–2021, USP <232>, ISO 17294-2, ASTM D6722-22 |
| Brand | JBS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Analyzer |
| Principle | Cold Vapor Atomic Fluorescence Spectrometry (CVAFS) |
| Detection Limit | ≤0.003 µg/L |
| Repeatability (RSD) | ≤5% |
| Linearity Error | ±5% |
| Zero Drift | <0.2 mV |
| Measurement Range | 0.01–100 µg/L |
| Noise Level | <0.1 mV |
| Correlation Coefficient (Calibration Curve) | ≥0.996 |
| Operating Temperature | 5–35 °C |
| Relative Humidity | ≤80% |
| Environmental Requirements | Low-vibration, low-EMI, mercury-free ambient, well-ventilated location with external exhaust capability |
| Brand | Kaiyuanhongsheng |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Benchtop Laboratory Analyzer |
| Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with Thermal Decomposition |
| Detection Limit | 0.001 ng |
| Repeatability | RSD ≤ 1% at 1 ng |
| Linearity Error | ±3% across calibration range |
| Measurement Range | 0.005–1500 ng Hg per sample |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | Light 915 |
| Instrument Type | Portable |
| Detection Principle | Zeeman Atomic Absorption Spectroscopy with High-Frequency Modulated Polarized Light (ZAAS-HFM) |
| Wavelength | 254 nm |
| Detection Limit | <0.1 µg/m³ |
| Operating Duration | Up to 12 h on rechargeable battery |
| Dynamic Range | 5 orders of magnitude |
| Data Storage | Internal memory with USB and Bluetooth export |
| Regulatory Status | Listed on U.S. EPA Emergency Response Equipment List |
| Compliance | Designed for compliance with OSHA PEL, ACGIH TLV, and ISO 6879 for elemental mercury vapor monitoring |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | Light 915 |
| Instrument Type | Portable |
| Measurement Principle | Zeeman Atomic Absorption Spectrometry with High-Frequency Modulation (ZAAS-HFM) |
| Detection Limit | 100 ng/m³ |
| Repeatability | ±1% RSD |
| Linearity Error | ±1% |
| Measurement Range | 0.1–3000 µg/m³ |
| Air Pump Flow Rate | 10 L/min |
| Analysis Time | Real-time |
| Dimensions | 290 × 210 × 110 mm |
| Weight | 3.3 kg |
| Power Supply | Internal 12 V DC rechargeable battery (12 h operation) / External 110–240 V AC, 50/60 Hz |
| Power Consumption | 20 W |
| Data Storage | Internal memory with USB and Bluetooth connectivity |
| Compliance | EPA Emergency Response Equipment List, ASTM D6784-22 (for mercury in air), ISO 6978-1:2003 (natural gas—mercury determination) |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | LS-915 |
| Instrument Type | Benchtop Laboratory System |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Detection Limit | 1 pg Hg |
| Repeatability | ≤1% RSD |
| Linearity Error | ≤2% |
| Sample Capacity | 75 positions |
| Solid Sample Mass | ≥1000 mg |
| Liquid Sample Volume | ≥500 µL |
| Robotic Architecture | Cartesian XYZ Coordinate System |
| Crucible Material | High-Purity Quartz (operable up to >1000 °C) |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | Pyro-915+ |
| Instrument Type | Portable |
| Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with Zeeman Background Correction |
| Detection Limit | 0.05 ng/mL (liquid) / 0.05 µg/kg (solid) |
| Repeatability | ±2% RSD |
| Linearity Error | ±1% |
| Sample Throughput | <2 min per sample |
| Operating Temperature Range | Programmable up to 950 °C |
| Air Monitoring LOD | 0.5 ng/m³ (10-s response) / 2 ng/m³ (1-s response) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Power Consumption | 700 W |
| Weight | 17.5 kg |
| Dimensions (Controller) | 400 × 280 × 135 mm |
| Dimensions (Furnace) | 430 × 340 × 135 mm |
| Continuous Operation | Up to 8 h |
| Carrier Gas Flow | 1.0–3.0 L/min |
| Sample Mass Range | 10–1500 mg |
| Upper Detection Limit | 200 mg/kg (based on 20 mg sample) |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | RA-915AM |
| Instrument Type | Online Analyzer |
| Measurement Principle | Zeeman Atomic Absorption Spectrometry with High-Frequency Modulation (ZAAS-HFM) |
| Detection Limit | 0.5 ng/m³ |
| Repeatability | ±1% |
| Linearity Error | ±2% |
| Gas Flow Rate | 3–10 L/min |
| Response Time | 10–300 s |
| Range I | 0.5–2000 ng/m³ |
| Range II | 100–400,000 ng/m³ |
| Operating Temperature | −20 to +50 °C |
| Pressure Range | 84–106.7 kPa |
| Relative Humidity | <99% at 35 °C |
| Power Supply | 240 VAC, 50/60 Hz |
| Power Consumption | 120 W |
| Dimensions | 600 × 480 × 220 mm |
| Weight | 19 kg |
| Communication Interfaces | RS-232, Dual USB, LAN, Isolated 4–20 mA Output |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RA-915AMNG |
| Instrument Type | Online Analyzer |
| Principle | Zeeman Atomic Absorption Spectrometry with High-Frequency Modulation (ZAAS-HFM) |
| Detection Limit | 0.5 ng/m³ |
| Repeatability | ±1% |
| Linearity Error | ±1% |
| Measurement Range | 0–2000 ng/m³ (configurable multi-range options available) |
| Reporting Interval | ≥2 s (user-definable) |
| Benzene Correction | Fully Automatic |
| Zero Drift Correction | User-selectable (recommended every 60 min) |
| Span Drift Correction | User-selectable (recommended every 3 h) |
| Calibration | Fully Automated (calibration source ≈12,000 ng/m³ Hg) |
| Sample Flow Rate | 7–10 L/min |
| Communication Protocol | Standard Bavarian Protocol (customizable upon request) |
| Status Outputs | SERVICE (zero/calibration mode), FAILURE, MEASURE (Bavarian) |
| Operating Temperature | 14–40 °C |
| Atmospheric Pressure | 84–106.7 kPa |
| Relative Humidity | <99% at 35 °C |
| Power Supply | 220–240 VAC, 50 Hz |
| Dimensions | 600 × 480 × 220 mm |
| Weight | 19 kg |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | RA-915F |
| Instrument Type | Portable |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with Thermal Decomposition |
| Detection Limit | 0.005 ng Hg |
| Repeatability | ±1% RSD |
| Linearity Error | ±1% |
| Detection Range | 5 orders of magnitude |
| Sample Throughput | 1–5 min per analysis |
| Power Supply | 220 VAC, 50 Hz (with optional DC/vehicle power adapter) |
| Dimensions (Analyzer Unit) | 300 × 260 × 130 mm |
| Weight (Analyzer Unit) | 4.0 kg |
| Dimensions (Thermal Decomposer Module) | 350 × 260 × 120 mm |
| Weight (Thermal Decomposer Module) | 7.5 kg |
| Dimensions (Power Supply Unit) | 380 × 260 × 130 mm |
| Weight (Power Supply Unit) | 10.0 kg |
| Sample Mass Range | 10–500 mg |
| Liquid Detection Limit | 0.5 µg/L |
| Solid Upper Quantitation Limit | 200 mg/kg |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | RA-915Lab |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Repeatability | <1.5% RSD |
| Linearity Error | ±5% |
| Sample Throughput | Up to 45 samples unattended |
| Analysis Time | ≤3 minutes per sample |
| Linear Range | 0–2,000,000 µg/kg (ppb–ppm equivalent across matrices) |
| Detection Capability | Sub-ng absolute sensitivity (matrix-dependent) |
| Compliance | EPA Method 7473, EPA 1631, EPA 30B, EPA SW-846 |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | RA-915M Series |
| Instrument Type | Portable |
| Principle | Zeeman Atomic Absorption Spectrometry with High-Frequency Modulation (ZAAS-HFM) |
| Detection Limit | 0.5 ng/m³ (10 s), 2 ng/m³ (1 s) |
| Repeatability | <2% RSD |
| Linearity Error | ±5% |
| Measurement Range | 0.5–200,000 ng/m³ |
| Zero Signal SD | <2 ng/m³ |
| 5-min Zero Drift | <2 ng/m³ |
| Warm-up Time | <20 min |
| Air Pump Flow Rate | >10 L/min |
| Power Supply | Internal 12 V DC battery (8 h continuous operation) or 110/220 V AC, 50/60 Hz |
| Dimensions | 460 × 110 × 220 mm |
| Weight | 7 kg |
| Power Consumption | 40 W |
| Compliance | EPA Method 1631, EPA SW-846 7473 & 30B, ASTM D7622-10, EN 1483 / 13806 / 15852, GB 7468-87 |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | RA-915S |
| Instrument Type | Portable |
| Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with Zeeman-effect background correction |
| Detection Limit | 0.01 µg/kg |
| Repeatability | ≤1% RSD |
| Linearity Error | ≤1% |
| Sample Introduction | Direct thermal decomposition (10–1500 mg solid/liquid) |
| Analysis Time | 1–2 min per sample |
| Dynamic Range | 5 orders of magnitude |
| Wavelength | 254 nm (Hg resonance line) |
| Power Supply | 198–242 VAC, 50 ± 1 Hz |
| Dimensions (Detector Unit) | 470 × 210 × 110 mm |
| Integrated Air Pump | Yes |
| Onboard Calibration | Certified Hg standard traceable to NIST |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | RA-915W |
| Instrument Type | Portable |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with High-Frequency Zeeman Background Correction (ZAAS-HFM) |
| Detection Limit | 0.5 ng/L |
| Repeatability | ±1% RSD |
| Linearity Error | ±1% |
| Compliance | EPA Method 1631, EPA SW-846, EN 1483 & EN 13806, HJ 543–2009, HJ 597–2011, GB 3838–2002, GB 5009.17–2014, WS/T 25–1996, GB/T 15555.1–1995, GB/T 17136–1997 |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RP-91NG |
| Instrument Type | Portable |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with High-Frequency Zeeman Modulation (ZAAS-HFM) |
| Detection Limit | 1 ng/m³ |
| Repeatability | ±1% RSD |
| Linearity Error | ±1% |
| Concentration Range | 0.5–20,000 ng/m³ (optional high- and ultra-high-concentration modes available) |
| Air Pump Flow Rate | 2–5 L/min |
| Operating Ambient Temperature | 1–40 °C |
| Atmospheric Pressure Range | 84.0–106.7 kPa |
| Relative Humidity | >95% at 35 °C |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Power Consumption | 35 W |
| Internal Battery Runtime | 8 h |
| Dimensions | 320 × 290 × 160 mm |
| Weight | 6.5 kg |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | RP-92 Liquid Mercury |
| Instrument Type | Portable |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Sample Volume | 0.5–20 mL |
| Air Pump Flow Rate | 0.8–4.2 L/min |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Power Consumption | 40 W |
| Pump Unit Net Weight | 3.0 kg |
| Pump Unit Dimensions | 360 × 225 × 125 mm |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | UMA |
| Instrument Type | Portable Mercury Analyzer |
| Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with Zeeman Background Correction |
| Detection Limit | 1 ppb |
| Repeatability | <1% RSD |
| Linearity Error | ±1% |
| Sample Throughput | Solid/Liquid analysis completed in ≤60 s |
| Gas Response Time | 1 s |
| Dynamic Range | 6 orders of magnitude |
| Power Supply | 100–240 VAC, 50/60 Hz or internal battery (8 h continuous operation) |
| Dimensions (Control Unit) | 400 × 280 × 135 mm |
| Dimensions (Thermal Decomposer Module) | 430 × 340 × 135 mm |
| Weight | 17.5 kg |
| Air Pump Flow Rate | 0.8–4.2 L/min |
| Liquid Sample Volume (CV Mode) | 0.5–20 mL |
| Solid Sample Mass (Thermal Decomposition) | 5–300 mg |
| Brand | Nippon Instruments Corporation (NIC) |
|---|---|
| Origin | Japan |
| Model | WA-5A |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with Dual Gold Amalgamation |
| Detection Limit | 0.001 ng (1 pg) |
| Linear Range | 0.001 – 1000 ng |
| Compliance | ASTM D5954-98(2014)e1, ISO 6978-2:2005, ISO 20552, JIS K 0312, HJ 910–2017, GB 16781.2–2010, HJ 597–2011, HJ 543–2009 |
| Sample Forms | Gaseous matrices (ambient air, natural gas, shale gas, LPG, LNG, hydrogen), aqueous samples (with S-MA/AQUA accessory) |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | RP-92 |
| Pricing | Upon Request |
| Instrument Type | Online/Field-Deployable |
| Analytical Principle | Cold Vapor Atomic Fluorescence Spectrometry (CV-AFS) |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Imported |
| Model | Hydra II AA |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Compliance | EPA Methods 245.1, 245.5, 245.6, 7470A, 7471B |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Imported |
| Model | Hydra II C |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Compliance | EPA Method 7473, SN/T 3511–2013, HJ 910–2017, HJ 917–2017, HJ 923–2017, Cosmetics Safety Technical Specifications (2015 Edition) |
| Sample Introduction | Direct Solid/Liquid Injection Without Prior Digestion |
| Optical Design | Dual-Beam, Dual-Cell Configuration with Real-Time Baseline Monitoring |
| Moisture Management | Integrated Desiccant Drying Tube |
| Operational Readiness | Ambient-Temperature Operation, No Preheating Required |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Benchtop Laboratory Analyzer |
| Model | DMA-500 |
| Pricing | Upon Request |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Sample Introduction | Direct Solid/Liquid/Gas Injection (No Acid Digestion Required) |
| Automation | 100-Position 4-Axis Robotic Autosampler |
| Thermal Treatment | Dual-Zone PID-Controlled Ashing & Catalytic Combustion Furnace |
| Trapping System | Constant-Power Heated Mercury Trap with Rapid Thermal Ramp |
| Detection Architecture | Tandem Dual-Absorption Cells + Dual-Beam Light Source Correction |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | DMA-600 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Sample Introduction | Direct Solid/Liquid/Gas Injection |
| Dual Sample Preparation Pathways | Catalytic Thermal Decomposition + Gold Amalgamation OR Stannous Chloride Reduction + Gold Amalgamation |
| Furnace Control | PID Temperature Regulation (Ashing & Catalytic Combustion Zones) |
| Mercury Trap | Constant-Power Heated Trap |
| Absorption Cell | Dual-Temperature-Controlled Flow-Through Cells (Heated to Maintain Hg⁰ in Vapor Phase) |
| Optical System | Dual-Beam Reference Compensation |