Microbial Limit Tester
Filter
Showing all 21 results
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Antares |
| Instrument Type | Automated Microcalorimetric Microbial Activity Monitoring System |
| Throughput | 19 samples |
| Sample Vessel | Ø40 × H86 mm ampoule |
| Temperature Range | 5–50 °C (water-circulating thermostat control) |
| Data Acquisition Interval | 60 s (continuous operation up to 166 days) |
| Dimensions | W465 × D650 × H500 mm |
| Weight | ~100 kg |
| Power Supply | AC 100 V, 10 A |
| Installation Requirement | Temperature-stabilized laboratory environment |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | LogPhase 600 |
| Instrument Type | Automated Microbial Growth Monitoring System |
| Throughput | Up to four 96-well microplates simultaneously |
| Optical Density Measurement | OD600 (600 nm) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Country of Origin | Imported |
| Model | MobiLab2 |
| Price | Upon Request |
| Dimensions | 560 × 220 × 350 mm (W × H × D) |
| Weight | 25 kg |
| Power Supply | AC adapter or integrated high-capacity rechargeable battery |
| Sample Throughput | 9 samples or 9 assays simultaneously |
| Thermal Block Temperature Range | 4 °C – 105 °C |
| PCR Module Temperature Uniformity | ±0.3 °C |
| PCR Module Temperature Accuracy | ±0.2 °C |
| Heating/Cooling Module | High-efficiency, long-life Peltier elements |
| Incubation & Shaking | 25–100 °C, up to 1400 rpm |
| Detection Method | RAH (Rapid Amplification and Hybridization) coupled with lateral flow immunoassay (LFIA) |
| Readout Format | Visual interpretation of dual-line lateral flow strips (control + test bands) in sealed reaction chambers |
| Brand | Charm |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Charm Peel Plate Colony Counter |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Instrument Type | Semi-Automatic Microbial Enumeration System |
| Detection Throughput | Up to 96 Peel Plate™ assays per hour (based on standard workflow) |
| Compatible Assay Formats | Total Aerobic Count, *E. coli*, Coliforms, Yeast & Mold, Enterobacteriaceae |
| Integrated Camera Resolution | ≥5 MP |
| Display | 6.75-inch diagonal touchscreen LCD |
| Dimensions (W × H × D) | 32.0 × 22.86 × 16.764 cm |
| Weight | 4.54 kg (10 lbs) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Onboard Storage Capacity | 66,000 assay records |
| Data Export Formats | JPEG (raw & processed images), CSV (quantitative results), SQL-compatible database output via Ethernet |
| Input Devices | Wireless keyboard/mouse, optional barcode scanner |
| Calibration Check | Configurable frequency — at startup, after user-defined count intervals, or on-demand |
| User Roles | Dual-tier (Operator + Administrator) with role-based access control (RBAC) |
| Compliance | Designed for GLP-compliant environments |
| Brand | Chuanyu Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | CHW-300BS |
| Instrument Type | Semi-Automatic Microbial Limit Testing System |
| Throughput | 3 independent filtration channels |
| Filter Membrane Diameter | Φ47 mm / Φ50 mm |
| Effective Filtration Area | 40 mm diameter |
| Filter Cup Capacity | 150 mL (250 mL optional) |
| Filtration Rate | 100 mL per 15 s |
| Vacuum Source | Built-in进口 diaphragm liquid-handling pump (oil-free) |
| Sterilization Methods | Autoclavable filtration heads |
| Display | LCD interface showing real-time time/date and pump status |
| Compliance | Designed for USP <61>, <62>, EP 2.6.12, and ISO 8573-7 compliant microbial enumeration workflows |
| Brand | CSY (Shenzhen Csys Instrument Manufacturing Co., Ltd.) |
|---|---|
| Origin | Guangdong, China |
| Instrument Type | Semi-Automatic Microbial Pathogen Detection System |
| Detection Throughput | 16-well |
| Sample Types | Solid, Liquid, Surface Swabs |
| Detection Mode | Qualitative and Semi-Quantitative |
| Display | 7-inch Capacitive Touchscreen |
| OS | Android 9.0 (2 GB RAM + 16 GB ROM, expandable to 128 GB via microSD) |
| Connectivity | 4G LTE (universal band), Wi-Fi 802.11 b/g/n, Ethernet, RS232, Dual USB (A & B), GPS Module |
| Data Export | USB export in TXT or Excel (.xlsx) format |
| Reporting | Built-in thermal label printer |
| Data Management | Cloud-ready architecture with platform interoperability (HTTP/HTTPS API compliant) |
| Regulatory Alignment | Designed to support GLP-compliant workflows and aligns with analytical requirements of GB 29921–2013, ISO 6579-1:2017, and AOAC Official Method 2012.06 for Salmonella detection in food matrices |
| Brand | FUELSTAT |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FUELSTAT® One |
| Detection Throughput | 1 sample per test |
| Brand | FUELSTAT |
|---|---|
| Origin | United Kingdom |
| Model | FUELSTAT® resinae PLUS |
| Instrument Type | Field-Deployable Rapid Microbial Detection Kit |
| Detection Targets | Hormoconis resinae (H. res), bacteria, fungi, and metabolically active yeasts |
| Reporting Format | Mass-based quantification (µg/mL of microbial biomass) |
| Compliance | ASTM D8070, IATA Guidance, JIG Online Approved, referenced in OEM AMMs |
| Time-to-Result | ≤10 min assay time, ≤15 min full report generation |
| Sample Volume | 4 drops (≈200 µL) of fuel |
| Software Integration | iOS/Android mobile application with encrypted data logging and cloud sync |
| Regulatory Context | Supports GLP-aligned field testing |
| Brand | JINTENG |
|---|---|
| Origin | Tianjin, China |
| Instrument Type | Semi-Automatic Membrane Filtration System |
| Filtration Stations | 3 |
| Filter Cup Capacity | 100 mL and 250 mL options |
| Filtration Method | Membrane Filtration (ISO 8573-7 / USP <61> / EP 2.6.12 compliant) |
| Construction Material | 316L Stainless Steel (Autoclavable up to 180°C) |
| Vacuum Source Compatibility | Diaphragm Vacuum Pump (external, not included) |
| Sealing Mechanism | Precision-machined sanitary clamp interface with silicone gasket |
| Regulatory Alignment | Designed for GLP-compliant workflows |
| Brand | JTONE |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Six-Station Membrane Filtration Assembly |
| Instrument Type | Semi-Automatic Microbial Limit Tester |
| Throughput | 1/3/6 Samples |
| Filtration Method | Integrated Diaphragm Pump–Driven Negative-Pressure Filtration |
| Filter Membrane Diameter | Φ47 mm / Φ50 mm |
| Effective Filtration Area | 40 mm |
| Filter Cup Capacity | 250 mL (Standard Stainless Steel) |
| Filter Cup Material Options | 304 Stainless Steel or PP |
| Sealing Design | Lip-Style Seal (O-Ring–Free) |
| Sterilization Compatibility | Autoclavable (121 °C, 20 min), Flame-Sterilizable Filter Heads |
| Filtration Rate | 100 mL in 15 s (with membrane) |
| Regulatory Alignment | Designed for compliance with USP <61>, <62>, EP 2.6.12, and ISO 8573-7 |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZR-1012 |
| Instrument Type | Automated Biological Safety Cabinet Challenge Tester |
| Detection Throughput | 10 simultaneous sampling points |
| Filter Cup Capacity | Standard microbiological filter holders (not applicable for filtration volume) |
| Filter Membrane Diameter | 50 mm (standard for impactor/slit samplers) |
| Aerosol Generation Rate | Up to 200 L/min (calibrated with PAO or Bacillus atrophaeus spore aerosol) |
| Compliance | YY 0569–2011, GB/T 16292–2010, ISO 14644-1 Class 5 equivalent containment verification |
| Brand | LuMeley |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Producer |
| Instrument Type | Semi-Automatic Microbial Filtration System |
| Filtration Capacity | 6 Samples Simultaneously |
| Dimensions (L×W×H) | 670 × 130 × 100 mm |
| Weight | 4.5 kg |
| Compatible Pump | LM-B02 Diaphragm Liquid Pump |
| Surface Finish | Electrolytically Polished & Brushed Stainless Steel |
| Filter Head Mounting | Threaded, Quick-Release |
| Sterilization Compatibility | Autoclavable (reusable cups), Flame-Sterilizable (pump heads), EO/Gamma-compatible (disposable cups) |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | NicePlate-20 |
| Instrument Type | Fully Automatic Microbial Media Dispensing System |
| Dispensing Range | 1–1000 mL |
| Accuracy at 15 mL | ±1% |
| Throughput | 400 Petri Dishes/hour |
| Compatible Dish Diameters | Ø90 mm (standard), 55 mm, 35 mm, 70 mm |
| Adjustable Dish Height | 12–26 mm |
| Dispensing Interval | 1–10 sec |
| UV Lamp Output | 2.3 W @ 254 nm |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 14313–47–ACN |
| Instrument Type | Automated Membrane Transfer System for Microbial Limit Testing |
| Sample Throughput | Single-unit membrane transfer per cycle |
| Filter Membrane Diameter | 47 mm |
| Compatible Microorganisms | Bacteria, Yeasts, Molds |
| Agar Surface Area | 13.2 cm² |
| Dimensions | Ø68.8 mm × H14.9 mm |
| Membrane Material | Polypropylene |
| Sterilization Method | Gamma irradiation (13.9–25.0 kGy) |
| Compatible Agar Media | R2A, Tryptic Soy Agar (TSA), Sabouraud Dextrose Agar (SDA) — inhibitor-free formulations |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | 168M3-MS |
| Filter Cup Capacity | Bacteria, Fungi, Yeast |
| Membrane Diameter Compatibility | Standard 47 mm |
| Assembly Time | ≤2 min per sample |
| Construction | Electropolished AISI 316L Stainless Steel |
| Sterile Venting | Integrated 3-way stainless steel valve with independent channel control |
| Compatibility | Microsart® @Filter 100/250, Microsart® Funnel 100/250, Biosart® 100/250 pre-assembled grid membranes, flame-sterilizable stainless steel funnels, autoclavable glass and polycarbonate filtration units |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | SMB01-201 |
| Instrument Type | Microbial Limit Testing System |
| Filter Cup Compatibility | Bacteria, Yeast, Molds |
| Membrane Diameter Support | 47 mm |
| Assembly Time | ≤2 min per sample |
| Sterile Venting | Integrated stainless steel 3-way valve |
| Material | Electropolished AISI 316L stainless steel |
| Compliance | Designed for ISO 8573-1 (compressed air purity), ISO 13408-1 (aseptic processing), and USP <61>/<62> microbiological testing workflows |
| Regulatory Alignment | Supports GLP/GMP documentation requirements via traceable system setup and operator-intervention logs |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | 166MP-4 |
| Instrument Type | Direct-discharge vacuum pump for microbial filtration |
| Maximum Membrane Pressure | 600 mbar |
| Air Flow Rate | ≥4.0 N·L/min (at ambient conditions, dry air) |
| Filtration Compatibility | Bacteria, yeasts, molds |
| Footprint Reduction vs. Conventional Systems | ~70% |
| Connection Interface | DN10 push-fit quick-connect fittings |
| Vacuum System Architecture | Oil-free, direct-discharge (no collection flask or trap required) |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | 16713-BO |
| Dimensions (L × H × W) | 233 × 172 × 230 mm |
| Weight | 2.6 kg |
| Power Options | AC adapter or built-in rechargeable battery |
| Membrane Feed Mechanism | Motor-driven sprocket roller system |
| Activation Modes | Touch button, infrared optical sensor (hands-free), foot switch |
| Compatible Membrane Format | Pre-folded sterile strip-packaged filters, 47 mm diameter (standard) |
| Membrane Type Support | Cellulose ester (CE), polyethersulfone (PES), nylon, and other standard microbiological filtration membranes |
| Compliance | Designed for ISO 11737-1, USP <61>, <62>, and EU Ph. Eur. 2.6.12 environments |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | Microsart™ e.motion |
| Membrane Material | Nitrocellulose (CN) |
| Pore Sizes | 0.2 µm, 0.45 µm, 0.8 µm |
| Diameters | 47 mm, 50 mm |
| Surface Finish | White/Black, Grey/White, Green/Dark Green, White/Green |
| Packaging | Individually sealed in proprietary folded pouches, sterile, no protective backing paper |
| Compatibility | Designed exclusively for Microsart™ e.motion filter dispenser and Sartorius adsorption pads |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 16421-A |
| Instrument Type | Automated Sterility Testing System |
| Detection Throughput | Qualitative |
| Filter Cup Capacity | 120 mL (graduated at 50, 75, and 100 mL) |
| Filter Membrane Diameter | 0.45 µm |
| Filtration Method | Peristaltic Pump |
| Flow Rate Control | 0–100 rpm |
| Dimensions (min) | 26 × 22.5 × 54.6 cm (W × D × H) |
| Dimensions (max) | 33.7 × 26.2 × 54.6 cm (W × D × H) |
| Brand | Toone |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TW-101A |
| Instrument Type | Semi-Automatic Microbial Limit Testing System |
| Detection Throughput | Single-sample per run |
| Power Supply | AC 220 V / 50 Hz |
| Power Consumption | 25 W |
| Pump Flow Rate | 1200 mL/min |
| Noise Level | ≤60 dB (under load) |
| Weight | 2.6 kg |
| Dimensions (W × D × H) | 15 × 25 × 11.2 cm |
| Drain Tube ID | Φ7–Φ11 mm silicone tubing |
| Compatible Consumables | TW-M50A membrane filtration units |