Microelectrode Array
Filter
Showing all 19 results
| Brand | 3Brain |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BioCAM DupleX |
| Instrument Type | Multiwell |
| Application Scope | In Vitro |
| Electrode Count | 4096 |
| Compliance | CE, ISO 13485 (for research use only) |
| Software Platform | BrainWave v5.x |
| Data Format | HDF5, MATLAB-compatible |
| Environmental Control Support | Integrated temperature & CO₂ regulation (37 °C ± 0.2 °C, 5% CO₂ ± 0.1%) |
| Recording Bandwidth | DC–10 kHz |
| Input Noise | < 3.5 µV RMS (1–10 kHz) |
| Brand | Axion BioSystems |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Maestro Edge / Maestro Pro |
| Throughput Format | Multiwell (96-well or 384-well compatible) |
| Application Scope | In Vitro |
| Electrode Count per Well | 384 or 768 |
| Stimulus Modalities | Electrical Stimulation + Optical Stimulation (405 nm, 470 nm, 530 nm, 630 nm LEDs) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Axion BioSystems |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Maestro PRO / EDGE |
| Throughput | Multi-well (24-, 48-, or 96-well formats) |
| Application Scope | In vitro electrophysiology |
| Electrode Count per Well | 384 or 768 |
| Regulatory Designation | Research Use Only (RUO) |
| Brand | Axion BioSystems |
|---|---|
| Origin | USA |
| Manufacturer | Axion BioSystems, Inc. |
| Product Type | Multiwell MEA Platform |
| Application | In Vitro Electrophysiology |
| Electrode Count | 384 or 768 per well |
| Configuration | 12-well Cytoview or 48-well Maestro plates |
| Regulatory Status | CE-marked, FDA-listed for research use only (RUO) |
| Brand | Axion BioSystems |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Maestro PRO / EDGE |
| Throughput | Multi-well (96-well or 48-well format) |
| Application | In vitro electrophysiological recording |
| Electrode Count per Well | 384 or 768 |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with FDA 21 CFR Part 11–enabled software configurations |
| Brand | Axion BioSystems |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Maestro Pro / Edge |
| Instrument Type | Multiwell (96-well or 384-well format) |
| Application | In Vitro Electrophysiology |
| Electrode Count | 384 or 768 electrodes per well |
| Regulatory Status | CE-IVD, FDA-listed for research use only (RUO) |
| Brand | Axion BioSystems |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Maestro PRO / EDGE |
| Instrument Type | Multiwell (6-/24-/48-/96-well format) |
| Application Scope | In Vitro |
| Electrode Count per Well | 384 or 768 |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with FDA 21 CFR Part 11–ready software audit trails |
| Brand | Axion BioSystems |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Maestro Pro / Edge |
| Instrument Type | Multiwell (6/24/48/96-well) |
| Application | In Vitro |
| Electrode Count per Well | 384 or 768 |
| Compliance | Designed for CiPA (Comprehensive in vitro Proarrhythmia Assay) framework, aligned with FDA, ICH S7B/S7B Q&A, and ISO 14155 guidelines for preclinical cardiac electrophysiology |
| Brand | Axion BioSystems |
|---|---|
| Origin | USA |
| Manufacturer | Axion BioSystems, Inc. |
| Product Type | Multiwell MEA Platform |
| Application | In Vitro Neural Network Recording |
| Electrode Count | 384 or 768 per well |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with FDA 21 CFR Part 11–enabled software configurations |
| Brand | Axion BioSystems |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Maestro PRO / EDGE |
| Instrument Type | Multiwell (6-/24-/48-/96-well) |
| Application | In Vitro |
| Electrode Count per Well | 384 or 768 |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with FDA 21 CFR Part 11–ready software configurations |
| Brand | Axion BioSystems |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Maestro Volt |
| Instrument Type | Multi-well |
| Application | In Vitro |
| Electrode Count | 384 |
| Brand | Bmseed |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | MEASSuRE |
| Electrode Spacing Options | 200, 330, 370, 400, 447, 960, 1140 µm |
| Electrode Diameter Options | 30, 70, 100, 200 µm |
| Electrode Count Options | 32, 60, 96 |
| Application | In Vitro Electrophysiological & Mechanobiological Studies |
| Brand | Hach |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-manufactured) |
| Model | HC9420 |
| Instrument Type | Single-Port |
| Application Scope | In-situ Process Monitoring (Bioreactors & Fermenters) |
| Electrode Configuration | Composite Glass + Reference Electrode |
| Electrode Count | 2 (Integrated pH-Sensing and Reference Elements) |
| Electrode Spacing | ~10 mm |
| Electrode Diameter | 12 mm |
| Available Lengths | 120 mm / 225 mm / 325 mm / 425 mm (Customizable Stem Length) |
| pH Range | 0–14 |
| Response Time (t₉₀) | <60 s |
| Operating Temperature | 0–130 °C |
| Max. Pressure Rating | 6 bar (gauge) |
| Junction Type | Dual-Liquid-Junction with Ceramic Frit |
| Temperature Sensor | Integrated PT1000 RTD |
| Membrane Material | High-Temperature Borosilicate Glass |
| Gel Electrolyte | Pre-pressurized Polymer Gel |
| Sterilization Compatibility | Validated for CIP (Clean-in-Place) and SIP (Steam-in-Place) per ISO 13485 & ASME BPE guidelines |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | E-201F |
| Electrode Type | Single-Unit Combination |
| Application | In Vivo & Routine Aqueous Solutions |
| Electrode Dimensions | 12 mm diameter × 120 mm total length |
| Inter-electrode Spacing | 10 mm |
| Electrode Configuration | Integrated Ag/AgCl Reference + Glass pH-Sensing Element |
| Housing Material | Polycarbonate |
| Junction Type | Fibrous Liquid Junction |
| Connector | BNC (Q9) |
| Temperature Range | 5–60 °C |
| pH Range | 0–14 |
| Refillable Reference Chamber | Yes |
| Protective Foot | Fixed, Non-removable |
| Included Accessories | Electrode Storage Bottle + KCl Fill Powder Kit |
| Brand | Axion BioSystems |
|---|---|
| Origin | USA |
| Manufacturer | Axion BioSystems, Inc. |
| Model | Lumos |
| Instrument Type | Multiwell (24/48/96-well) |
| Application | In Vitro Electrophysiology |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with FDA 21 CFR Part 11–enabled software environments |
| Software Integration | Native interoperability with Maestro MEA acquisition and analysis platform |
| Brand | Axion BioSystems |
|---|---|
| Origin | USA |
| Manufacturer | Axion BioSystems, Inc. |
| Product Type | Multiwell MEA Platform |
| Application | In Vitro Electrophysiology |
| Electrode Count | 384 or 768 per well |
| Model Variants | Maestro PRO, Maestro EDGE |
| Brand | MappingLab |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Single-Well Format |
| Application Domain | In Vitro Electrophysiology |
| Electrode Configurations | 32-, 64-, 128-, and 256-channel flexible or rigid substrates |
| Substrate Options | Polyimide-based flexible arrays (thickness down to 10 µm) and glass-based rigid arrays (50 × 50 × 1 mm base |
| electrode diameters | 20/30/50 µm |
| well inner diameter | 22 mm) |
| Compatibility | Langendorff-perfused hearts, open-chest in vivo preparations, tissue slices, monolayer cardiomyocyte cultures |
| Mechanical Integration | Compatible with MappingLab multi-axis micromanipulator (universal joint mount), perfusion chambers, Faraday cages, and humidified incubator environments |
| Regulatory Context | Designed for GLP-compliant preclinical cardiac electrophysiology studies |
| Brand | Multi Channel Systems |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MEA2100-mini |
| Instrument Type | Single-Well Format |
| Application Scope | In Vitro Electrophysiological Recording & Stimulation |
| Electrode Pitch | 200 µm |
| Electrode Diameter | 30 µm |
| Electrode Layout | 8×8 (60 active + 4 ground/ reference electrodes, or 120-channel variant) |
| Physical Dimensions | 186 × 80 × 12 mm |
| Amplifier Resolution | 24-bit |
| Max Sampling Rate per Channel | 50 kHz |
| Stimulator Modes | Current Source (±1 mA), Voltage Source (±10 V) |
| Signal Acquisition Units per MCS-IFB Interface Board | Up to 2 |
| Probes per Acquisition Unit | Up to 4 |
| Integrated On-Probe Electronics | Amplification, Stimulation, and ADC |
| Operating Environment | Standard CO₂ incubators (37 °C, 5% CO₂, humidified) |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Type | Ion-Selective Electrode (ISE) |
| Series | 500 (Half-Cell) and 800 (All-in-One Composite) |
| Connector Options | BNC or DIN |
| Measurement Range | Ion-specific, spanning from sub-ppb to saturated concentrations (e.g., F⁻: 0.02 mg/L to saturation |
| NH₄⁺ | 0.02–900 mg/L |
| NO₃⁻ | 0.4–62,000 mg/L) |
| Compliance | Designed for ASTM D1293, ISO 10523, USP <781>, and EPA Method 9056A applications |