Microplate Reader
Filter
Showing all 27 results
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | 800 TS |
| Function Type | Absorbance-Only Microplate Reader |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, and Scanning |
| Curve Fitting Options | Multiple nonlinear regression models (e.g., 4PL, 5PL, linear, quadratic, log-log) |
| Detector Type | Photodiode-based UV-Vis spectrophotometric detector |
| Wavelength Range | 400–750 nm standard |
| Absorbance Range | 0–4.0 OD |
| Absorbance Linearity | ±1.0% ± 0.010 OD (0–2.0 OD at 405 nm) |
| Plate Read Time | 11 seconds per 96-well plate |
| Precision | ±1.0% ± 0.010 OD (0–2.0 OD at 405 nm) |
| Incubation Temperature | Up to 50 °C |
| Orbital Shaking | Linear and orbital modes |
| Supported Plate Formats | 6-, 12-, 24-, 48-, 96-, 384-well microplates |
| Filter Capacity | 5-position filter wheel |
| Onboard Storage | Internal memory + USB export capability |
| Software Platform | Integrated touchscreen interface + compatibility with Agilent BioTek Gen5 v3.11 or later |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Epoch |
| Function Type | Absorbance-Only Microplate Reader |
| Automation Level | Fully Automated |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 200–999 nm |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Epoch2 |
| Function Type | UV-Vis Absorbance-Only Microplate Reader |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Spectral Scan |
| Curve Fitting Options | Linear, Quadratic, Cubic, Four-Parameter Logistic (4PL), Five-Parameter Logistic (5PL), Log-Log, Spline |
| Detector Type | UV-Visible Photodiode Array |
| Wavelength Range | 200–999 nm (1 nm increments) |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | ±1% ± 0.01 OD (0–2 OD) |
| Plate Read Time | 8 sec (96-well), 14 sec (384-well) |
| Precision | ±1% ± 0.01 OD (0–2 OD) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | Synergy H1 |
| Pricing | Upon Request |
| Functionality | Multi-Mode |
| Automation Level | Fully Automated |
| Assay Methods | Endpoint, Kinetic, Wavelength Scan, Well Area Scan |
| Curve Fitting Options | Linear, Logarithmic, Four-Parameter Logistic (4PL), Five-Parameter Logistic (5PL) |
| Detector Type | Photomultiplier Tube (PMT) / Photodiode (PD) |
| Wavelength Range | Filter-based: 200–700 nm |
| Monochromator-based | 250–900 nm |
| Absorbance Range | 0.0000–4.0000 OD |
| Absorbance Linearity | Not Specified |
| Read Speed | 96-well plate in 11 s |
| Accuracy | Not Specified |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Synergy HTX |
| Function Type | Multi-Mode |
| Automation Level | Fully Automated |
| Assay Methods | Endpoint, Kinetic, Well-Scanning |
| Curve Fitting Options | Linear, Point-to-Point, Four-Parameter Logistic (4PL) |
| Detector Types | Fluorescence, UV-Vis Absorbance, Luminescence, Time-Resolved Fluorescence (TRF), AlphaScreen/AlphaLISA |
| Wavelength Range | Filter-Based: 200–850 nm |
| Monochromator-Based | 200–999 nm |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | <1% deviation from ideal linearity across 0–3.0 OD |
| 96-Well Read Time | 14 seconds |
| Absorbance Precision | ±0.0001 OD |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Synergy LX |
| Function Type | Multimode |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Well-Scanning |
| Curve Fitting Options | Linear, Point-to-Point, Four-Parameter Logistic (4PL) |
| Detector Types | UV-Vis Absorbance, Fluorescence Intensity, Luminescence |
| Wavelength Range | Filter-Based: 320–850 nm |
| Monochromator-Based | 200–999 nm |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | <1% deviation from ideal over 0–2.5 OD |
| Read Time (96-well plate) | 12 s |
| Absorbance Precision | ±0.0001 OD |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | BioTek Synergy Neo2 Hybrid |
| Detection Methods | Absorbance, Fluorescence Intensity (tunable bandwidth), Luminescence, Time-Resolved Fluorescence (TRF), Fluorescence Polarization (FP), TR-FRET, BRET, AlphaScreen/AlphaLISA |
| Detector Types | Dual Photomultiplier Tubes (PMTs), Monochromator-based and Filter-based Optical Paths, 337 nm Pulsed Laser for TRF, 100 mW Solid-State Laser for Alpha Detection |
| Automation | Fully Automated with BioStack Neo |
| Environmental Control | 4-Zone Temperature Control up to 70 °C, CO₂/O₂ Regulation, Anti-Condensation System, Linear & Orbital Shaking |
| Sample Formats | 6–1536-well Microplates, Take3/Take3 Trio Microvolume Plates, Petri Dishes, Cell Culture Dishes |
| Software | Gen5 v3.1+ with LIMS Integration, FDA 21 CFR Part 11 Compliance Support, Audit Trail, Electronic Signatures |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | Take3 |
| Pricing | Upon Request |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | AMR-100 |
| Function Type | Multimode |
| Automation Level | Fully Automated |
| Measurement Principle | Filter-Based Absorbance Detection |
| Wavelength Range | 400–750 nm |
| Absorbance Range | 0.000–4.000 Abs |
| Linearity | ±1% (0–2.000 Abs), ±2% (2.000–4.000 Abs) |
| Accuracy (405 nm) | ±1% (0–3 Abs), ±2% (3–4 Abs) |
| Precision (CV, 405 nm) | ≤0.2% (0–3 Abs), ≤1.0% (3–4 Abs) |
| Detection Speed | <6 s/96-well (single wavelength), <9 s/96-well (dual wavelength) |
| Optical System | 8-channel high-precision fiber-optic path with automatic well-centering |
| Filter Capacity | 8-position filter wheel (standard filters: 405, 450, 490/492, 630 nm) |
| Display | 7-inch color TFT touchscreen (800 × 480 px) |
| Plate Compatibility | Standard 96-well microplates and strip formats |
| Onboard Storage | 200 protocols + 100,000 assay results (96-well format) |
| Interfaces | 3 × USB (PC, printer, USB drive), Wi-Fi |
| Power Supply | AC 100–240 V, 50–60 Hz |
| Lamp Type | Long-life halogen lamp (≥4000 h) |
| Built-in Diagnostics | Real-time self-check of optical path, mechanical positioning, plate loading, and filter alignment |
| Shaking Function | Adjustable speed and duration |
| Safety Mechanism | Motorized door with obstacle-detection reversal |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | AMR-100T |
| Detection Principle | Filter-based photometric absorbance |
| Wavelength Range | 340–750 nm |
| Absorbance Range | 0.000–4.000 Abs |
| Resolution | 0.001 Abs |
| Linearity (R²) | ≥0.995 (0–3.0 Abs) |
| Wavelength Accuracy | ≤±2 nm |
| Absorbance Precision (CV) | ≤0.3% (0–3 Abs), ≤1.0% (3–4 Abs) |
| Absorbance Stability | ≤0.005 Abs (0–3 Abs) |
| Absorbance Accuracy | ±0.005 Abs (0–2 Abs), ±0.01 Abs (2–3 Abs), ±1.5% (3–4 Abs) |
| Measurement Speed | 6 s/96-well (single wavelength, fast mode) |
| Filter Capacity | 8-position wheel (standard 4 filters: 405, 450, 492, 630 nm) |
| Incubation Function | Yes, 25°C to 50°C (RT + 4°C min) |
| Display | 7-inch capacitive touchscreen |
| Data Storage | Internal memory for 1000 protocols & results + USB export |
| Interfaces | 3× USB (host/device), supports printer, PC, and flash drive |
| Power | AC 100–240 V, 50–60 Hz, 2 A |
| Dimensions (W×D×H) | 295 × 440 × 225 mm |
| Weight | 10 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | AMR-Mini |
| Light Source | Dual high-stability LED (340–750 nm) |
| Detection Principle | Absorbance (Optical Density) |
| Standard Filters | 450/630 nm & 405/492 nm |
| Custom Filter Options | 340–750 nm (28 wavelengths available) |
| Detector | 9-photodiode array |
| Measurement Range | 0–4.0 Abs |
| Resolution | 0.001 Abs |
| Wavelength Accuracy | ≤ ±2 nm |
| Linearity | R² ≥ 0.995 (0.0–3.0 Abs) |
| Photometric Accuracy | ≤ ±(0.5% + 0.01 Abs) [0.0–2.0 Abs), ≤ ±(1.0% + 0.01 Abs) [2.0–3.0 Abs) |
| Precision (CV) | ≤ 0.5% [0–3.0 Abs) |
| Stability | ≤ 0.005 Abs [0.0–2.0 Abs) |
| Read Time | <15 s (single wavelength), <28 s (dual wavelength) for 96-well plate |
| Dimensions (W×D×H) | 135 × 225 × 89 mm |
| Weight | 2.0 kg |
| Power | USB-powered (12 V, 3 A) |
| Interface | 1 × USB-C, 1 × USB-A |
| Connectivity | Bluetooth 5.0, USB cable |
| Software | Cross-platform PC application (Windows 7/10 64-bit), bilingual UI (English/Chinese) |
| Optional Module | AMR-Mini T with integrated incubation (up to 45 °C) and orbital shaking (200–1,200 rpm) |
| Brand | Allsheng |
|---|---|
| Model | AMR-Mini T |
| Detection Principle | Absorbance (Optical Density) |
| Wavelength Range | 340–750 nm |
| Standard Filters | 450/630 nm & 405/492 nm |
| Optional Filters | 340–750 nm (28 discrete wavelengths available) |
| Light Source | Dual high-stability LED |
| Detector | 9-photodiode array |
| Measurement Modes | Endpoint, Kinetic, Dual-Wavelength |
| Absorbance Range | 0–4.0 Abs |
| Resolution | 0.001 Abs |
| Accuracy | ≤±(0.5% + 0.01 Abs) @ 0.0–2.0 Abs |
| Linearity | R² ≥ 0.995 (0.0–3.0 Abs) |
| Repeatability | CV ≤ 0.5% (0–3.0 Abs) |
| Stability | ≤0.005 Abs (0.0–2.0 Abs) |
| Read Time | <15 s (single-wavelength, 96-well), <28 s (dual-wavelength, 96-well) |
| Incubation Temp Range | RT+4°C to 45°C |
| Dimensions (W×D×H) | 135 × 245 × 91 mm |
| Weight | 2.5 kg |
| Interface | USB-A, USB-C, Bluetooth 5.0 |
| Power | 12 V DC, 3 A |
| Software | Cross-platform PC application (Windows 7/10 64-bit) and mobile app (iOS/Android), bilingual UI (English/Chinese) |
| Compliance | Designed per ISO 15197:2013 and CLSI EP17-A2 guidelines for quantitative absorbance-based immunoassays |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Feyond-A500 |
| Detection Modes | Absorbance, Fluorescence (Top-Read), Chemiluminescence, Time-Resolved Fluorescence (TRF), Fluorescence Polarization (FP) |
| Wavelength Range (Abs) | 200–1000 nm, 1 nm step |
| Absorbance Range | 0–4 OD |
| Absorbance Accuracy | ±(1.0% + 0.003 OD) at 450 nm (0.0–2.0 OD) |
| Absorbance Precision | CV < 1.0% or SD < 0.003 OD (96-well, precise mode) |
| Read Time (96-well) | <15 s (fast mode) |
| Luminescence Sensitivity | ≤15 amol/plate (ATP assay) |
| Dynamic Range (Luminescence) | 6 decades |
| Fluorescence Sensitivity | ≤1 pM (FITC in 96-well) |
| TRF Sensitivity | ≤0.05 pM (Eu-labeled conjugate) |
| FP Sensitivity | ≤5 mP (standard assay) |
| Excitation/Emission Filter Capacity | 3 pre-installed dual-filter sets (e.g., EX470/EM525), modular & barcode-readable |
| Incubation | PID-controlled, dual-zone (top/bottom), 25–45 °C ±0.5 °C |
| Display | 10-inch motorized rotatable touchscreen (standalone operation) |
| Software | Onboard analysis suite including endpoint, kinetics, spectral scan, standard curve fitting (4PL/5PL), qualitative/quantitative modules, GLP-compliant audit trail (optional PC software: ReaderLT-I) |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Feyond-L100 |
| Detection Principle | Chemiluminescence (PMT-based) |
| Detection Limit | 5 amol ATP per well |
| Linear Dynamic Range | 6 logs |
| Well-to-Well Crosstalk | ≤0.005% |
| Wavelength Range | 200–850 nm |
| Plate Formats | 6–384-well microplates |
| Automation Level | Fully Automated (integrated dispensers) |
| Compliance | GLP-ready architecture, audit-trail capable software (ReaderLT-I), supports 21 CFR Part 11-compliant configurations |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Feyond-MF200 / Feyond-MF280 |
| Absorbance Range | 190–1000 nm (1 nm step) |
| Absorbance Accuracy | ±(1.0% + 0.003 OD) @ 0.0–2.0 OD |
| Absorbance Precision (CV) | <1.0% (standard mode), <0.5% (high-precision mode) |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability (SD) | ≤0.2 nm |
| Spectral Bandwidth (FWHM) | ≤2.5 nm |
| Optical Density Resolution | 0.0001 OD |
| Linear Range (R²) | ≥0.999 @ 0.0–3.0 OD |
| Stray Light | ≤0.1% @ 220 nm |
| Read Time (96-well plate) | <15 s (A1→H1, fast mode) |
| Fluorescence Detection | Top-read mode, Xenon lamp excitation, PMT detection |
| Standard Filter Sets | 470/525 nm, 523/564 nm, 624/692 nm (up to 8 filter positions) |
| Fluorescence LOD | ≤2 pM (96-well black plate, optimized conditions) |
| Dynamic Range | ≥6 decades |
| Plate Compatibility | 6–384-well standard and micro-volume plates |
| Incubation Temperature Range | RT+4°C to 45°C |
| Temp. Uniformity | ≤1.0°C @ 37°C |
| Temp. Accuracy | ±0.5°C @ 37°C |
| Agitation Modes | Linear, orbital, dual-orbital |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | FlexA-200 |
| Detection Principle | Absorbance (UV-Vis) |
| Wavelength Range | 200–1000 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ±0.2 nm |
| Optical System | Grating-based monochromator with 1 nm step resolution |
| Read Range | 0–4.0 OD |
| Bandwidth | <2.5 nm |
| Photometric Accuracy @450 nm | ±(1.0% + 0.003 Abs) for 0–2.0 Abs |
| Photometric Precision @450 nm | CV < 0.5% (precise mode), CV < 1.0% (fast mode) |
| 96-well Plate Read Time | ~8 s (fast), <28 s (precise, endpoint) |
| Temperature Control Range | Ambient +4 °C to 45 °C |
| Temp. Uniformity & Accuracy | ±0.5 °C at 37 °C |
| Detector | Dual silicon photodiodes (sample + reference beam) |
| Display | 10-inch capacitive touchscreen (Android OS) |
| Onboard Storage | 16 GB (≥20,000 assay files) |
| Connectivity | 1× USB-B, 2× USB-A, 1× Ethernet |
| Dimensions (W×D×H) | 300 × 500 × 260 mm |
| Net Weight | 15.5 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | FlexA-200HT |
| Detection Principle | Absorbance (UV-Vis) |
| Wavelength Range | 200–1000 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ±0.2 nm |
| Optical System | Grating-based monochromator, dual-beam with reference channel |
| Spectral Resolution | 1 nm step |
| Absorbance Range | 0–4.0 OD |
| Linearity (at 450 nm) | R ≥ 0.999 [0.0–3.0 Abs] |
| Absorbance Accuracy (at 450 nm) | ±(1.0% + 0.003 Abs) [0–2.0 Abs], ±2.0% [2.0–2.5 Abs] |
| Absorbance Precision (CV) | <0.5% (precise mode), <1.0% (fast mode) |
| 96-well Plate Read Time | ~8 s (fast), <28 s (precise, endpoint) |
| Temperature Control Range | Ambient +4 °C to 45 °C |
| Temp. Uniformity & Accuracy | ±0.5 °C at 37 °C |
| Incubation | Integrated plate and cuvette chamber |
| Vibration | Linear, 3-speed adjustable |
| Detector | Dual silicon photodiodes (sample + reference) |
| Bandwidth | <2.5 nm |
| Light Source | Xenon flash lamp (>1×10⁹ flashes lifetime) |
| Display | 10-inch capacitive touchscreen (Android OS) |
| Onboard Storage | 16 GB (≥20,000 assay records) |
| Connectivity | 2× USB-A, 1× USB-B, 1× Ethernet |
| Dimensions (W×D×H) | 300 × 500 × 260 mm |
| Weight | 15.5 kg |
| Brand | Autobio |
|---|---|
| Model | LUMO |
| Detection Method | Chemiluminescence |
| Detector Type | Imported Photomultiplier Tube (PMT) |
| Luminescence Range | 10⁰–10⁹ RLU |
| Plate Format | 96-well and 48-well microplates |
| Read Time per Well | 0.1–10 s |
| Full 96-Well Plate Read Time | <32 s |
| Sensitivity | 10⁻² mol/plate |
| Precision (CV) | <2% |
| Inter-well Cross-Talk | <5×10⁻⁷ |
| Plate Shaking Modes | 3 programmable patterns (speed & duration adjustable) |
| Power Input | 220 V ± 22 V AC |
| Power Consumption | <32.4 VA |
| Dimensions (L×W×H) | 470 × 335 × 205 mm |
| Weight | 13 kg |
| Safety Compliance | CE-marked, 24 V DC internal supply, ISO 13485 certified |
| Brand | Autobio |
|---|---|
| Model | PHOMO |
| Origin | Henan, China |
| Instrument Type | Multifunctional Automated Microplate Reader |
| Assay Mode | Endpoint |
| Calibration Curve | Linear |
| Detector | Dual-LED Laser-Based Photodiode Array |
| Wavelength Range | 200–1000 nm |
| Absorbance Range | 0–4.5 OD |
| Absorbance Linearity | 0.000–2.000 Abs ±0.01% |
| Measurement Speed | 12 s (single wavelength), 20 s (dual wavelength), 6 s (kinetic single-wavelength) |
| Precision (CV) | <0.5% |
| Repeatability (CV) | ≤0.15% |
| Light Source | Dual-LED Cold Light Source (Lifetime ≥100,000 h) |
| Optical Architecture | RSE (Real-time Spectral Enhancement) Silicon Photodetector Platform |
| Scan Mode | Multi-point per well (up to 9 points) |
| Brand | Benchmark |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | MultiBlock |
| Function Type | Multi-Block, Gradient-Capable, Touchscreen-Controlled Thermal Cycler |
| Heating/Cooling System | Peltier-based |
| Display | 10-inch Full-Color Adjustable-Tilt Touchscreen |
| Communication Ports | USB 2.0, LAN |
| Temperature Range | 4°C to 99.9°C |
| Max Heating Rate | 7.5°C/sec |
| Max Cooling Rate | 6.0°C/sec |
| Temperature Uniformity | ≤ ±0.2°C at 90°C |
| Temperature Accuracy | ≤ ±0.2°C at 90°C |
| Ramp Rate Adjustment | 0.1–5.0°C/sec |
| Gradient Function | Yes (8-zone independent gradient per block) |
| Gradient Accuracy | ±0.1°C |
| Gradient Range | 30–99.9°C |
| Heated Lid | Yes |
| Lid Temperature Range | 30–112°C |
| Software Features | Password-Protected User Accounts, Protocol Transfer via USB, Audit-Trail-Ready Program Storage, On-Device Protocol Wizard |
| Brand | BMG LABTECH |
|---|---|
| Origin | Germany |
| Model | Micro-GCM omega |
| Detection Modes | Absorbance (220–1000 nm), Fluorescence (up to 8 channels), Luminescence |
| Temperature Control | Ambient +4 °C to 45 °C (optional up to 65 °C), ±0.1 °C accuracy, sandwich dual-zone heating |
| Humidity Control | Compatible with specialized breathable, anti-evaporation microplate sealing films |
| Gas Control | Atmospheric Control Unit (ACU) for independent or coupled regulation of O₂ (0.1–20%) and CO₂ (0.1–20%) |
| Shaking | Linear, orbital, or dual-orbital |
| Detection Speed | <1 second per well for full-spectrum absorbance (220–1000 nm) |
| Plate Formats | 6–384-well microplates |
| Software | Preconfigured assay templates, kinetic data acquisition, GLP-compliant audit trail, EC₅₀/IC₅₀ fitting, 4-parameter logistic regression, standard curve generation |
| Automation | Dual high-precision injectors (min. 3 µL injection volume, dead volume <30 µL, up to 4 injections/well with simultaneous read) |
| Brand | Dynamica |
|---|---|
| Model | HALO MPR-96 |
| Origin | Switzerland |
| Wavelength Range | 400–750 nm (MPR-96UV: 340–750 nm) |
| Absorbance Range | 0–4.0 OD |
| Resolution | 0.001 OD |
| Stability | ±0.001 OD (after 15 min warm-up) |
| Accuracy | ±1.0% ±0.01 OD (405 nm, 0.000–2.500 OD) |
| Repeatability | ±0.5% ±0.005 OD (405 nm, 0.000–2.500 OD) |
| Linearity | ±1.0% (405 nm, 0.000–2.500 OD) |
| Filter Positions | 5 (4 fixed + 1 user-selectable, 400–750 nm) |
| Read Time | ≤10 s (single wavelength, 96-well) |
| Plate Formats | 96-well flat, U-bottom, V-bottom |
| Optical Channels | 8 measurement + 1 reference |
| Detector | Silicon photodiode |
| Light Source | Tungsten-halogen lamp |
| Display | Backlit LCD, 320×240 px |
| Incubation (optional) | Ambient +4°C to +50°C, ±0.5°C accuracy |
| Dimensions (W×D×H) | 290×425×200 mm |
| Weight | 15 kg (net), 20 kg (gross) |
| Power | 110–220 V auto-switching, 50/60 Hz, 50 W (standby), 100 W (operational) |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SuPerMax-3100 |
| Function Type | Multimode |
| Automation Level | Fully Automated Microplate Reader Workstation |
| Assay Modes | Endpoint Fluorescence, Absorbance, Chemiluminescence (ELISA/EIA) |
| Curve Fitting Options | Multiple nonlinear regression models (e.g., 4PL, 5PL, linear, quadratic, log-log) |
| Detectors | Photodiode (Absorbance), PMT (Fluorescence), Photon Counting PMT (Chemiluminescence) |
| Wavelength Range | 190–1000 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | <0.2 nm |
| Excitation & Emission Monochromators | Dual high-resolution grating monochromators |
| Bandwidth | Adjustable from 2 to 20 nm |
| Temperature Control Range | Ambient to 65 °C |
| Plate Formats | Standard 96-well (customizable to 24-, 384-, 1536-well) |
| Dispensing Capability | Dual-channel liquid handler (expandable to quad-channel) |
| Reading Modes | Top-read and bottom-read fluorescence |
| Kinetic & Spectral Scanning | Supported |
| Software Compliance | IQ/OQ/PQ validated |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Model | SpectraMax 190 |
| Detection Method | Absorbance (UV-Vis) |
| Automation Level | Fully Automated |
| Wavelength Range | 190–850 nm (1 nm step) |
| Minimum Bandwidth | 2 nm |
| Absorbance Range | 0–4.0 OD |
| Pathlength Correction | Patented PathCheck™ sensor (temperature-independent, converts to 1-cm equivalent) |
| Detection Channels | 8-sample + 1-reference photodiode array |
| Temperature Control | Ambient +4°C to 45°C (±0.5°C accuracy) |
| Orbital Shaking | Linear or orbital, programmable speed/amplitude |
| Microvolume Capability | SpectraDrop™ module (2 µL/sample, 64 wells/scan, dsDNA sensitivity: 2 ng/µL) |
| Software | SoftMax Pro® 7 (GLP-compliant, 21 CFR Part 11 ready, audit trail, 19 curve-fit models, custom equation editor) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | Multiskan™ FC |
| Functionality | Absorbance-only microplate reader |
| Automation Level | Fully automated |
| Assay Modes | Endpoint and kinetic |
| Curve Fitting Options | Linear, 4-parameter logistic (4PL), 5-parameter logistic (5PL), quadratic, cubic, log-log, semi-log |
| Detector Type | Photodiode-based UV-Vis spectrophotometer |
| Wavelength Range | 340–850 nm |
| Absorbance Range | 0–6.0 OD |
| Linearity | ±2% deviation from theoretical value within 0–4.0 Abs (96-well plate, standard mode) |
| Read Speed | 6 seconds per 96-well plate (fast mode) |
| Precision | CV ≤ 0.2% (0–3.0 Abs, standard mode) |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Model | TY-MB96L |
| Detection Method | Absorbance (Photometric) |
| Function Type | Multifunctional |
| Automation Level | Fully Automated |
| Detector Type | Photodiode-based Absorbance Detector |
| Wavelength Range | 340–750 nm |
| Precision | CV ≤ 0.2% (0–3 Abs), CV ≤ 1.0% (3–4 Abs) — Standard Measurement Mode (@405 nm) |
| Filter Wheel | 8-position, 4 standard filters included (405/450/492/630 nm), optional filters available across 340–750 nm |
| Read Range | 0–4.000 Abs |
| Resolution | 0.001 Abs |
| Linearity | ±1% (0–3.0 Abs), ±2% (3.0–4.0 Abs) @405 nm |
| Accuracy | ±1% (0–3 Abs), ±2% (3–4 Abs) @405 nm |
| Reading Speed | <6 s (96-well plate, rapid mode) |
| Memory Capacity | 200 protocols + 100,000 96-well results |
| Display | 7″ color TFT-LCD touchscreen (1280×800 px) |
| OS | Embedded Android-based firmware |
| Light Source | 6 V / 10 W halogen lamp (rated lifetime: 2000 h) |
| Interfaces | 3 × USB (for PC, printer, USB storage) |
| Dimensions (W×D×H) | 440 × 295 × 225 mm |
| Weight | 10 kg |
| Power Supply | AC 100–240 V, 50–60 Hz, 2 A |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nanoliter2000 |
| Pricing | Upon Request |