| Brand | DS |
|---|---|
| Origin | Zhejiang, China |
| Model | JY-8500 |
| Instrument Type | Paraffin Microtome |
| Automation Level | Semi-Automatic Cryo/Paraffin Microtome |
| Section Thickness Range | 0–100 µm |
| Sample Maximum Dimensions | 70 × 30 mm |
| Specimen Advance per Revolution | 1 µm |
| Specimen Orientation Adjustment | 0–15° |
| Cutting Speed | 100 mm/s (knife travel) |
| Dimensions (W × D × H) | 80 × 360 × 380 mm |
| Brand | LANENDE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Cryostat Microtome |
| Automation Level | Semi-Automatic |
| Section Thickness Range | 0–60 µm (with 0.5–5 µm incremental steps per range) |
| Specimen Vertical Travel | 50 mm |
| Specimen Horizontal Travel | 20 mm |
| Max Section Area | 55 × 45 mm |
| Specimen Orientation Adjustment | ±8° horizontal, ±8° vertical, 360° rotation |
| Knife Base Translation Range | ±25 mm front/back, ±25 mm left/right |
| Knife Angle Adjustment | 0–15° |
| Overall Dimensions | 500 × 480 × 280 mm |
| Compliance | Designed for GLP-compliant histopathology workflows |
| Brand | LANENDE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Cryostat Microtome |
| Model | LD-4080 |
| Cooling System | Dual-Compressor with Five-Point Targeted Cooling |
| Operating Temperature Range | Cryohead: −50 °C, Cryostage: −45 °C, Cryoblade: −35 °C, Chamber: −25 °C ± 5 °C |
| Section Thickness Range | 0–100 µm (adjustable in 0.5 µm increments up to 6 µm |
| Minimum Graduation | 0.5 µm |
| Specimen Horizontal Travel | 25 mm |
| Specimen Vertical Travel | 60 mm |
| Trimming Range | 0–600 µm (10 µm increments) |
| Sectioning Angle Adjustment | ±10° |
| Sectioning Speed | Adjustable |
| Cryo-Positioning Stations | 12 |
| Power Supply | 220 V AC, 800 VA |
| Net Weight | 120 kg |
| Compliance | Designed for GLP-compliant histopathology workflows |
| Brand | LANENDE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | LD-4080 |
| Cutting Thickness Range | 0–100 µm (0.5 µm minimum increment) |
| Sample Horizontal Travel | 25 mm |
| Sample Vertical Travel | 60 mm |
| Sectioning Angle Adjustment | ±10° |
| Five-Point Refrigeration System (Cryotome Head | –50°C, Cryostage: –45°C, Cryoblade: –35°C, Chamber: –25°C ±5°C) |
| Rapid Cool-down | <10 min to operational cryo-state |
| Power Supply | 220 V, 800 VA |
| Net Weight | 120 kg |
| Brand | SLEE |
|---|---|
| Origin | Germany |
| Model | CUT 6062 |
| Instrument Type | Paraffin Microtome |
| Automation Level | Fully Automatic Cryo-Paraffin Microtome |
| Section Thickness Range | 0.5–100 µm (adjustable in 0.5 µm increments) |
| Cutting Speed | User-Configurable |
| Maximum Specimen Size | 50 × 50 mm |
| Dimensions (W × D × H) | 480 × 610 × 350 mm |
| Weight | 34 kg |
| Compliance | CE, ISO 13485 (Medical Device Quality Management), IEC 61010-1 (Laboratory Equipment Safety) |