Molecular Fluorescence Spectrometer
Filter
Showing 31–55 of 55 results
| Brand | Ruihai Photonics (Oceanhood) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | PL980 |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Spectral Resolution | ~4 nm @ 25 µm slit |
| Wavelength Accuracy | ≤3% peak-to-peak (@ 2 hrs) |
| Excitation Wavelength | 976 ± 3 nm, Linewidth < 0.2 nm |
| Laser Power Stability | ≤3% P-P (@ 2 hrs) |
| Laser Lifetime | 10,000 hrs |
| Output Power Range | 0–500 mW adjustable |
| Optical Density (OD) of Notch Filter | OD8 |
| Probe Working Distance | 7.5 mm |
| Probe Fiber Length | ~1.5 m |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 5–80% RH |
| Excitation Fiber Core | 105 µm VIS-NIR |
| Emission Collection Fiber Core | 200 µm VIS-NIR |
| Spectral Range | 1000–1700 nm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | RF-6000 |
| Wavelength Accuracy | ±1.0 nm |
| Spectral Bandwidth (Slit Width) | 1.0–20.0 nm |
| Optical Resolution | 1.0 nm |
| Sensitivity (S/N Ratio) | ≥1000:1 (RMS) |
| Wavelength Range | Excitation 200–900 nm, Emission 200–900 nm |
| Scan Speed | Up to 60,000 nm/min |
| Light Source | Long-life Xenon Lamp (2000 h typical lifetime) |
| Detector | Broadband Photomultiplier Tube (PMT), extended to 900 nm |
| Dispersion Element | Dual grating + interference filter system |
| Quantum Yield Measurement | Supported (absolute and relative) |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Wavelength Dispersion Element | Holographic Grating |
| Slit Width (Spectral Bandpass) | 1.0–20.0 nm |
| Optical Resolution | 0.2 nm |
| Sensitivity | 1200:1 (RMS), 15,000:1 (RMS with Background Subtraction) |
| Wavelength Accuracy | ±2 nm |
| Excitation Source | Pulsed Xenon Arc Lamp |
| PMT Detection Range | Up to 900 nm |
| Maximum Scan Speed | 30,000 nm/min |
| Software | FL Analyst (English & Chinese GUI) |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Wavelength Dispersion Element | Grating |
| Slit Width (Spectral Bandpass) | 1.0–20 nm |
| Optical Resolution | 0.2 nm |
| Sensitivity | >450:1 (Peak-to-Peak) |
| Wavelength Accuracy | ±2.0 nm |
| Excitation Source | Xenon Arc Lamp |
| Standard PMT Range | Up to 900 nm |
| Maximum Scan Speed | 30,000 nm/min |
| Spectral Correction | Full-mode (Excitation/Emission/Spectral Response) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | NanoDrop 3300 |
| Excitation Source | Filter-based LED array |
| Excitation Wavelength Range | 400–750 nm |
| Spectral Resolution | <3 nm FWHM (at Hg 546.1 nm) |
| Wavelength Accuracy | ±1 nm |
| Detection Mode | Full-spectrum fluorescence emission (400–750 nm) |
| Sample Volume | As low as 1 µL |
| Power Supply | USB-powered (no external power adapter required) |
| Cuvette-Free Operation | Yes |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | Lumina |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth (Slit) | 0.5 nm |
| Resolution | 0.5 nm |
| Sensitivity | >4000:1 (at water Raman peak) |
| Wavelength Accuracy | ±0.5 nm |
| Excitation Source | 150 W Xenon Arc Lamp |
| Optical Design | Horizontal Beam Path |
| Monochromator Type | Grating-based, Pre-aligned Modular Monochromator |
| Detector | High-sensitivity PMT with extended red response |
| Brand | Topo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Wavelength Range | Typically 200–900 nm (Xenon Lamp Source) |
| Excitation/Emission Monochromators | Czerny-Turner with Holographic Grating |
| Slit Width (Spectral Bandpass) | 1–20 nm |
| Optical Resolution | ≤1 nm (FWHM at 546.1 nm) |
| Wavelength Accuracy | ±1 nm |
| Sensitivity | >300 P-P, >1200 RMS, >15,000 RMS (Background-Subtracted) |
| Light Source | 150 W Pulsed or Continuous Xenon Arc Lamp |
| Detector | R928P Photomultiplier Tube (PMT) |
| Data Acquisition Modes | Emission Scan, Excitation Scan, Synchronous Scan, Time-Based Intensity Monitoring, 3D Excitation-Emission Matrix (EEM) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | FlashSENS |
| Price | USD 84,000 (FOB Beijing) |
| Dispersive Element | Holographic Grating |
| Slit Width (Spectral Bandpass) | 0.01–3 mm (motorized, programmable) |
| Spectral Resolution | 0.6 nm @ 300 grooves/mm |
| Sensitivity | 0.00024 OD (optical density) |
| Wavelength Accuracy | ±0.8 nm @ 300 grooves/mm |
| Detection Light Source | LDLS-based Supercontinuum White Light (190–2100 nm) |
| Time Resolution | <7 ns (optional ultrafast mode: 3 ns) |
| Sample Compatibility | Solid films, liquid solutions, colloidal suspensions, thin-film devices |
| Measurement Modes | Transient Absorption Kinetics (ΔA vs. t), Transient Absorption Spectra (ΔA vs. λ), Dual-mode (kinetics + spectra) |
| Monochromator | Omni-λ300i, 300 mm focal length |
| Detector Options | Si photodiode (300–1100 nm), InGaAs array (900–1600 nm), ICCD (180–850 nm, gated, -25°C thermoelectric cooling) |
| Pump Laser Compatibility | Nd:YAG harmonics (1064/532/355/266 nm), tunable OPO (210–2400 nm) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Flex One |
| Price | USD 70,000 (approx.) |
| Dispersive Element | Holographic Grating & Interference Filters |
| Slit Width (Spectral Bandpass) | 0.05 nm |
| Optical Resolution | 0.1 nm |
| Wavelength Accuracy | ±0.2 nm |
| Spectral Range | 300–2200 nm (standard configuration) |
| Spatial Resolution | <50 µm |
| Excitation Wavelength Options | 266, 325, 405, 442, 473, 532, 633, 785 nm |
| Detector Options | Cooled Si CCD (2000×256), PMT, Single-Point InGaAs, Cooled InGaAs Array (512×1), or Custom Detector Modules |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Dispersive Element | Grating + Bandpass Filters |
| Integration Configuration | Glovebox-Compatible Fiber-Coupled Optical Path (Y-Fiber Geometry) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Dispersive Elements | Holographic Grating + Bandpass/Notch Filters |
| Excitation Sources | CW Laser Diode, Pulsed Laser (ns–ps range), Electrical Probe Station (for e-pumped lasing) |
| Detection Mode | Confocal Micro-Spectroscopy with Back-Illuminated CCD or EMCCD |
| Spatial Resolution | Diffraction-Limited (~300 nm lateral at 532 nm) |
| Spectral Range | 200–1100 nm (configurable) |
| Temporal Resolution | Down to <100 ps (with TCSPC option) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | MiniPL 5.0 eV |
| Excitation Wavelengths | 224 nm (5.5 eV) or 248.6 nm (5.0 eV) |
| Spectral Range (Standard) | 190–650 nm |
| Spectral Range (Optional) | 190–850 nm |
| Resolution (Standard) | 0.2 nm @ 1200 g/mm grating |
| Resolution (Optional) | 0.07 nm @ 3600 g/mm grating |
| Detector | High-sensitivity PMT |
| Signal Processing | Built-in boxcar averager for pulsed signal integration |
| Sample Stage | Manual XYZ adjustment, max. 50 mm diameter |
| Optional | Motorized XY scanning stage for PL mapping |
| Dimensions | 15 × 18 × 36 cm |
| Weight | < 8 kg |
| Software Platform | LabVIEW-based control & spectral analysis suite |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Excitation Sources | 808 nm, 980 nm, 1064 nm, 1550 nm, 1940 nm CW lasers |
| Detection Range | 1–5.5 μm (InSb), 2–12 μm (MCT), 800–2600 nm (TE-InGaAs), 300–1700 nm (LN-PMT) |
| Spectral Resolution | ≤0.1 nm (with 320 mm Czerny-Turner monochromator & 68 mm × 68 mm gratings) |
| Fluorescence Lifetime Range | μs to seconds (with TCSPC or oscilloscope synchronization) |
| Optical Platform | Damped vibration-isolation table (1800 × 1200 × 800 mm) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omni-fs-TA |
| Instrument Type | Transient Absorption Spectrometer |
| Temporal Resolution | 1.5 × Laser Pulse Width |
| Sensitivity | 0.1 ΔmOD (broadband), 0.01 ΔmOD (single-wavelength) |
| Pump Wavelength Ranges | 240–480 nm, 475–1160 nm, 1160–1600 nm, 1600–2600 nm |
| Probe Wavelength Ranges | 300–700 nm |
| Detection Time Window | 4 ns / 8 ns |
| Laser Sources | 800 ± 10 nm, 1030 ± 3 nm |
| Sample Formats | Liquid, Powder, Thin Film |
| Measurement Modes | Transmission, Reflection, Back-Excitation |
| Software Features | Probe Stability Monitoring, Real-Time Spectral Preview, Spectral Calibration, Smoothing, Global & Target Data Fitting |
| Optional Modules | Micro-area Spectroscopy, Wide-field Transient Absorption Imaging, TCSPC (2 ps min. time step, 100 ps min. lifetime range, 0.08 nm spectral resolution), Femtosecond Kerr-Gated Time-Resolved Fluorescence (400–900 nm, 50 fs pulse width, 4 ns window) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | OmniFluo |
| Price Range | USD 28,000–42,500 (FOB) |
| Dispersive Element | Holographic Grating |
| Slit Width (Spectral Bandpass) | 0.01–3 mm |
| Spectral Resolution | ±0.05 nm |
| Sensitivity | >3000:1 (Water Raman S/N ≥1000:1) |
| Wavelength Accuracy | ±0.15 nm |
| Spectral Range | 200–2500 nm |
| Excitation Sources | 150 W / 500 W Xenon Arc Lamp with Monochromator (Bandwidth 0.1–30 nm) |
| Optional Lasers | 266, 325, 375, 405, 442, 532, 785, 1064 nm |
| Detector Options | Cooled CCD (2000×256, 200–1000 nm), Cooled InGaAs Array (512×1, 800–2200 nm), PMT (200–870 nm), Cooled Single-Element InGaAs (800–2500 nm) |
| Signal Processing | Photon Counting or Lock-in Amplification |
| Optional Modules | Quantum Yield Measurement, Electroluminescence (EL), Cryogenic Sample Stage (≤10 K) |
| Emission Spectrum Correction | Built-in Absolute Intensity Calibration Function |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | OmniFluo Series |
| Price Range | USD 28,000 – 43,000 (FOB) |
| Dispersive Element | Holographic Grating & Interference Filters |
| Slit Width (Spectral Bandpass) | Adjustable, 0.1–5.0 mm |
| Spectral Resolution | 0.1 nm (FWHM @ 546.1 nm) |
| Sensitivity | 3000:1 (Signal-to-Noise Ratio, RMS, water Raman peak at 350 nm excitation, 5 nm bandwidth, 1 s integration) |
| Wavelength Accuracy | ±0.2 nm (Emission), ±0.25 nm (Excitation) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | OmniFluo-FLIM Series |
| Dispersion Element | Grating |
| Instrument Type | Steady-State/Time-Resolved Fluorescence Spectrometer |
| Spatial Resolution | ≤1 µm @ 100× Objective @ 405 nm Picosecond Pulsed Laser |
| Spectral Range | 200–900 nm |
| Minimum Time Resolution | 16 ps |
| Fluorescence Lifetime Range | 500 ps – 1 µs |
| Instrument Response Function (IRF) | ≤2 ns |
| Excitation Sources | 375–670 nm Picosecond Pulsed Lasers (50 MHz Repetition Rate, Pulse Widths: 25–75 ps) |
| Microscope | Upright Research-Grade with Brightfield/Darkfield Illumination, 5-Position Objective Turret (10×/50×/100×), High-Definition CMOS Monitoring Camera |
| XY Stage | Motorized, 75 × 50 mm Travel, 50 nm Minimum Step, <1 µm Repeatability |
| Spectrograph | 320 mm Focal Length, Imaging-Corrected Monochromator, Triple 68 × 68 mm Gratings, Wavelength Accuracy: ±0.1 nm, Repeatability: ±0.01 nm, Slit Width: 0.01–3 mm Motorized |
| Detector Options | UV-Vis PMT (185–900 nm), Back-Illuminated Deep-Depletion CCD (2000 × 256 pixels, 15 µm × 15 µm, -60 °C Cooling) |
| TCSPC Module | Time Bins Down to 16 ps, Dead Time <10 ns, Up to 65,535 Histogram Channels, Instantaneous Saturation Count Rate: 100 Mcps |
| Software | OmniFluo-FM FLIM Acquisition & Analysis Suite (Multi-Exponential Fitting ≤4 Components, IRF-Free Fitting Modes, Pseudocolor Mapping, 3D Visualization, Line/Cross-Section/Histogram/Contour Tools) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | OmniFluo960 |
| Dispersion Element | Holographic Grating |
| Slit Width (Spectral Bandpass) | 0.01–3 mm (excitation), 0.023–7 mm (emission) |
| Spectral Resolution | ≤ 0.08 nm |
| Sensitivity | Water Raman Signal-to-Noise Ratio ≥ 10,000:1 (at 350 nm excitation, 370–450 nm scan, 5 nm slit, 1 s integration) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.1 nm |
| Focal Length | 320 mm |
| Stray Light | ≤ 1×10⁻⁵ |
| Detector Options | CR131 (cooled red-sensitive PMT, 185–900 nm), R928, R13456, H10330C-75, R5509-73 |
| Standard Sample Chamber | SAC-FLS with cuvette, powder & solid sample holders |
| Automated Light Shield | Yes |
| Dark Count | ≤ 100 CPS (at –10°C) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Model | OmniFluo990 |
| Dispersion Element | Grating |
| Slit Width (Spectral Bandpass) | 0.01–3 mm (excitation), 0.023–7 mm (emission) |
| Spectral Resolution | 0.08 nm |
| Sensitivity | Water Raman Signal-to-Noise Ratio ≥ 10,000:1 |
| Wavelength Accuracy | ±0.2 nm |
| Lifetime Range | 500 ps – 10 s |
| Excitation Source | Gloria75X 75 W Xenon Arc Lamp |
| Emission Monochromator | Omni-λ3027i (f = 320 mm) |
| Stray Light | < 1×10⁻⁵ |
| Grating Options | 1200 g/mm BLZ@500 nm, 600 g/mm BLZ@750 nm, 300 g/mm BLZ@1250 nm |
| Detector | Cooled Red-Sensitive PMT CR131 (185–900 nm), Dark Count ≤ 100 CPS at –10 °C |
| Data Acquisition | DCS900PC TCSPC Module (Timing Resolution: 16 ps – 33.55 µs |
| Max Count Rate | 100 Mcps) |
| Software | ZolixScan v4.x (Steady-State Scanning, Time-Resolved Kinetics, TRES, QY Calculation, Spectral Correction, GLP-Compliant Audit Trail) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | OmniPL Series |
| Price Range | USD 28,000 – 42,500 |
| Dispersive Elements | Holographic Grating & Bandpass Filters |
| Slit Width (Spectral Bandpass) | Adjustable, 10–2000 µm |
| Spectral Resolution | < 0.2 nm (@ 1200 g/mm grating) |
| Signal-to-Noise Ratio | 3000:1 |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.1 nm |
| Excitation Source | HeCd Laser (325 nm, 20 mW) |
| Rayleigh Cutoff Filter | OD > 6 |
| Spectral Detection Range | 300–850 nm (expandable to 2500 nm) |
| Detector | Scientific-grade, thermoelectrically cooled back-illuminated CCD (300–1000 nm) |
| Optional Cryogenic Stage | Closed-cycle cryostat, 2 K minimum operating temperature |
| Software | Fully programmable acquisition protocol engine with spectral arithmetic, batch processing, and audit-trail logging |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | OmniPL-MicroS-A (Vertical-Path Configuration) |
| Price Range | USD 14,000 – 28,000 |
| Dispersive Element | Filter-Based Spectral Selection |
| Spectral Bandpass (Slit) | 200–1600 nm |
| Spectral Resolution | 0.1 nm |
| Sensitivity | >100:1 (Signal-to-Noise Ratio) |
| Wavelength Accuracy | ±0.2 nm |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | RTS2-FLIM |
| Dispersion Element | Grating |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Spatial Resolution | ≤1 µm @ 100× objective, 405 nm excitation |
| Excitation Source | Picosecond Pulsed Lasers (375–670 nm), 50 MHz repetition rate |
| Time Resolution | 16 ps |
| Fluorescence Lifetime Range | 500 ps – 1 µs |
| Instrument Response Function (IRF) | ≤2 ns |
| Spectral Range | 200–900 nm |
| Microscope Configuration | Upright research-grade microscope with epi-illumination, halogen lamp (12 V / 100 W), 5-position objective turret (10×/50×/100×), high-definition CMOS monitor camera |
| Scanning Stage | Motorized XY stage (75 × 50 mm travel, 50 nm step size, <1 µm repeatability) |
| Spectrograph | 320 mm focal length, imaging-corrected monochromator, dual input ports, CCD & slit outputs, three 68 × 68 mm gratings, wavelength accuracy ±0.1 nm, repeatability ±0.01 nm, scan step 0.0025 nm |
| Detector Options | UV-VIS PMT (185–900 nm), back-illuminated deep-depletion scientific CCD (2000 × 256 pixels, 15 µm × 15 µm, -60 °C cooling, QE >95%) |
| TCSPC Module | Time binning down to 16 ps, dead time <10 ns, up to 65,535 time channels, instantaneous saturation count rate 100 Mcps |
| Software | OmniFluo-FM — integrated FLIM acquisition, multi-exponential decay fitting (≤4 components), IRF-aware convolutional fitting, pseudo-color mapping, histogram/contour/3D visualization, GLP-compliant data logging |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | SmartFluo-QY |
| Dispersion Element | Grating + Interference Filters |
| Slit Width (Spectral Bandpass) | 0.1–30 nm |
| Spectral Resolution | 0.1 nm (@1200 g/mm, 435.83 nm) |
| Sensitivity | 3000:1 (Water Raman S/N, blue-sensitive detector) |
| Wavelength Accuracy | ±0.2 nm (@1200 g/mm) |
| Excitation Range | 200–600 nm (standard) |
| Emission Range | 200–1000 nm (standard) |
| Detector Options | R1527P (200–670 nm), R928P (200–870 nm), R2658P (200–1010 nm) |
| Stray Light Rejection | <1×10⁻⁵ |
| Integration Time | 10–200 s |
| Scan Speed | Up to 100 nm/s |
| Quantum Yield Measurement | Integrated sphere-based absolute method (4-step protocol) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SmartFluo-Pro |
| Price | USD 25,000 (FOB) |
| Dispersive Element | Holographic Grating |
| Slit Width (Spectral Bandpass) | 5 nm |
| Spectral Resolution | 5 nm |
| Detection Limit | <0.1 µg/L quinine sulfate in 0.1 mol/L H₂SO₄ |
| Wavelength Accuracy | ±1 nm |
| Excitation Range | 200–800 nm |
| Emission Range | 200–800 nm |
| Excitation Monochromator | 200 mm focal length, Czerny–Turner configuration, low stray light design |
| Grating Density | 1800 grooves/mm @ 400 nm |
| Wavelength Repeatability | ±0.5 nm |
| Integration Time | 100 µs to 24 s |
| Standard Sample Holder | Quartz cuvette (10 mm path length) |
| Dimensions (L×H×W) | 620 × 415 × 300 mm |
| Weight | 25 kg |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | TCSPC Plus |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Time Resolution | 2 / 4 / … / 33,554,432 ps |
| Time Channels | 65,535 |
| Dead Time | 2 ns |
| Timing Jitter | <10 ps |
| Maximum Instantaneous Count Rate | 500 Mcps |
| PMT Detector | R928P (Spectral Range: 185–900 nm |
