| Brand | 3P Instruments |
|---|---|
| Origin | Germany |
| Model | mixSorb L |
| Maximum Adsorption Pressure | 68 bar |
| Number of Mass Flow Controllers (MFCs) | 4 |
| Detector Type | TCD (Thermal Conductivity Detector) |
| Column Dimensions (Standard) | 30 mm ID × 200 mm length |
| Gas Range | Customizable |
| Column Configuration | Customizable |
| Temperature Pre-treatment Range | Up to 400 °C |
| Heating Rate | Up to 10 K/min |
| Software | mixSorb Manager & 3P sim |
| Compliance | Designed for GLP/GMP-aligned operation with audit-trail-capable data logging |
| Brand | 3P Instruments |
|---|---|
| Origin | Germany |
| Model | mixSorb S |
| Maximum Adsorption Pressure | 68 bar |
| Mass Flow Controllers (MFCs) | 4 |
| Detector | TCD (Thermal Conductivity Detector) |
| Temperature Control | Up to 400 °C pre-treatment, Linear Heating Rate: 10 K/min |
| Software | mixSorb Manager (real-time control & programmable operation), 3P sim (data fitting, breakthrough curve simulation, multicomponent adsorption modeling, selectivity/affinity/kinetics calculation) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | BSD-MAB |
| Price Range | USD 70,000 – 140,000 (FOB China) |
| Gas Mixture Compatibility | Binary and multicomponent gas–gas, gas–vapor, vapor–vapor systems |
| Mass Flow Controllers (MFCs) | 4–8 independently programmable channels |
| Breakthrough Columns | Standard stainless-steel columns (2 mL and 8 mL volumes) |
| Adsorption Pressure Range | Ambient to 10 MPa (optional high-pressure modules: up to 1 MPa or 3 MPa) |
| Adsorption Temperature Control | Circulating water bath (−20 °C to 80 °C, ±0.1 °C stability) |
| High-Temperature Furnace | Ambient to 600 °C (customizable beyond) |
| Detection Systems | Integrated thermal conductivity detector (TCD) |
| Detection Limits | TVOC: 5 × 10⁻¹² g/mL |
| SO₂ | 14 × 10⁻¹² g/mL |
| NH₃ | 16 × 10⁻¹² g/mL |
| Vapor Generation System | P/P₀ control range 0.1%–99.99%, accuracy ±1% |
| Vacuum Activation | <0.1 Pa base pressure |
| Corrosive Gas Compatibility | SO₂, NH₃, organic vapors (compatible with fluorocarbon-sealed components) |
| Regulatory Compliance Support | ASTM D5228, ISO 12213-2, USP <621>, GLP-compliant data audit trail (via optional software module), FDA 21 CFR Part 11-ready configuration available |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BSD-MAB1 |
| Gas Range | Binary & Ternary Mixtures Including Gas/Gas, Gas/Vapor, Vapor/Vapor |
| MFC Channels | 4–8 |
| Breakthrough Columns | Standard 2 mL & 8 mL Stainless Steel or Quartz Columns (Custom Volumes Available) |
| Adsorption Pressure | Ambient to 10 MPa |
| Adsorption Temperature | Circulating Water Bath (−20 °C to 80 °C), High-Temperature Furnace (RT to 600 °C |
| Detector Options | Integrated TCD, Optional Online GC or Mass Spectrometer (MS) |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JW-MIX100 |
| Gas Range | Customizable |
| Mass Flow Controllers (MFCs) | 4 units |
| Column Configuration | Customizable breakthrough columns |
| Maximum Adsorption Pressure | 100 bar |
| Detector | Thermal Conductivity Detector (TCD) |