| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | VERSA STAR (VM-01 refers to base configuration) |
| Compliance | GLP, USP <645>, ASTM D1125, ISO 7888, ISO 5814, ISO 10523, FDA 21 CFR Part 11 (with optional audit trail software) |
| Data Storage | 2000 GLP-compliant entries |
| Connectivity | Dual USB + RS232 |
| Module Capacity | Up to 4 simultaneous modules |
| IP Rating | IP54 |
| Power | 90–260 V AC, 50–60 Hz |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 9565 |
| Compliance | NIST-traceable calibration certificate included |
| Probe Interface | Hot-swap modular probe system |
| Display | Backlit graphical LCD (up to 5 simultaneous parameters) |
| Data Logging | Internal memory supports up to 38.9 days at 1-minute sampling interval |
| Connectivity | USB and Bluetooth® v4.0 |
| Software | LogDat2™ and TrakPro™ Data Analysis Software included |
| Environmental Rating | IP54-rated housing |
| Operating Temperature | 0–50 °C |
| Storage Temperature | –20–60 °C |
| Power | 4× AA alkaline or rechargeable NiMH batteries (typical life: 20 hrs with continuous use) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 9565 / 9565A / 9565P / 9565X |
| Temperature Range (964/966/980/982 probes) | −10 to 60 °C, ±0.3 °C accuracy |
| Temperature Range (960/962 probes) | −18 to 93 °C, ±0.3 °C accuracy |
| Temperature Range (995 vane probe) | 0 to 60 °C, ±0.1 °C accuracy |
| Air Velocity Range (960/962) | 0–50 m/s, ±3% of reading or ±0.015 m/s (whichever is greater), 0.01 m/s resolution |
| Air Velocity Range (995 vane) | 0.25–30 m/s, ±1% of reading or ±0.02 m/s |
| Air Velocity Range (pitot tube) | 31.27–78.7 m/s, ±1.5% at 10.16 m/s |
| CO Range (982 probe) | 0–500 ppm, ±3% of reading or ±3 ppm |
| CO₂ Range (980/982 probes) | 0–5000 ppm, ±3% of reading or ±50 ppm |
| Relative Humidity Range | 0–95% RH, ±3% RH |
| Static/Differential Pressure Range | −28.0 to +28.0 mmHg (−3735 to +3735 Pa), ±1% of reading or ±0.01 mmHg |
| Barometric Pressure Range | 517.15–930.87 mmHg, ±2% of reading |
| Data Storage | 26,500 readings across 100 user-defined data groups |
| Sampling Interval | 1 s to 1 h |
| Operating Temperature | 5–45 °C |
| Dimensions | 9.7 × 21.1 × 5.3 cm |
| Weight (with batteries) | 0.36 kg |
| Power | 4 × AA batteries or optional AC adapter |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 9565 / 9565-A / 9565-P / 9565-X |
| Temperature Range (964/966/980/982 probes) | −10 to 60 °C |
| Temperature Accuracy | ±0.3 °C (at 25 °C) |
| Temperature Resolution | 0.1 °C |
| Air Velocity Range (960/962 probes) | 0–50 m/s |
| Air Velocity Accuracy | ±3% of reading or ±0.015 m/s, whichever is greater |
| Air Velocity Resolution | 0.01 m/s |
| CO Range (982 probe) | 0–500 ppm |
| CO Accuracy | ±3% of reading or ±3 ppm, whichever is greater |
| CO₂ Range (980/982 probes) | 0–5000 ppm |
| CO₂ Accuracy | ±3% of reading or ±50 ppm, whichever is greater |
| CO₂ Resolution | 1 ppm |
| Relative Humidity Range | 0–95% RH |
| RH Accuracy | ±3% RH (at 25 °C) |
| RH Resolution | 0.1% RH |
| Pressure Range (Differential/Static) | −3735 to +3735 Pa |
| Pressure Accuracy | ±1% of reading or ±1 Pa |
| Pressure Resolution | 1 Pa |
| Data Storage Capacity | 26,500 data points across 100 user-defined groups |
| Operating Temperature | 5–45 °C |
| Dimensions | 9.7 × 21.1 × 5.3 cm |
| Weight (with batteries) | 0.36 kg |
| Power | 4 × AA batteries or optional AC adapter |
| Brand | Senbe |
|---|---|
| Origin | USA |
| Manufacturer | Original Equipment Manufacturer (OEM) |
| Product Type | Imported Instrument |
| Model | 9565-X |
| Pricing | Available Upon Request |