Mycotoxin Rapid Test Instrument
Filter
Showing all 12 results
| Brand | Anpro |
|---|---|
| Model | EV-X |
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Automated Immunoassay Analyzer for Mycotoxins, Heavy Metals & Pesticide Residues |
| Compliance | GB 2761–2017, GB 2762–2022, LST 6111–2015 to LST 6114–2015, LST 6144–2023, LST 6145–2023 |
| Throughput | ≥20 samples/hour (40 test results/hour) |
| Sample Capacity | 10 independent reaction channels |
| Detection Principle | Quantitative Enzyme-Linked Immunosorbent Assay (ELISA) with photometric readout |
| Sample Types | Cereals, oilseeds, feedstuffs, edible oils, dairy products, traditional Chinese medicinal materials |
| Key Analytes | Aflatoxin B₁, Aflatoxin M₁, Total Aflatoxins, Deoxynivalenol (DON), Zearalenone (ZEN), Fumonisins, Ochratoxin A, T-2 Toxin, Pb, Cd, Cr, Cu, Acetamiprid, Emamectin benzoate, Isoprocarb, Carbaryl, Parathion-methyl, Lambda-cyhalothrin |
| LOD Range | 0.01–10 ppb (mycotoxins), 0.01–0.1 ppm (pesticides), 0.02–0.1 ppm (heavy metals) |
| Liquid Handling Accuracy | ≤1% CV |
| Automation Scope | Full unattended workflow — sample loading, extraction, dilution, reagent preheating, cartridge preheating, incubation, optical detection, and data upload |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SKJ-IA-01 |
| Instrument Class | Multi-Mycotoxin Immunoassay Analyzer |
| Detection Principle | Colloidal Gold-Based Lateral Flow Immunoassay (Quantitative) |
| Throughput | 6 samples per run |
| Assay Time per Sample | ≤10 min |
| Display | 7-inch capacitive touchscreen |
| Integrated Thermal Printer | Yes |
| Data Connectivity | Wi-Fi / USB / Optional 4G module |
| Regulatory Validation | Official evaluation reports issued by the State Grain Administration (China) for AFB1, DON, ZEN, and OTA |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | SKJ-IA-Z |
| Instrument Category | Aflatoxin Analyzer |
| Detection Principle | Immunochromatographic Colloidal Gold Assay |
| Display | 7-inch Capacitive Touchscreen |
| Test Format | Single-use, individually packaged lateral flow test strips |
| Storage Condition | Ambient Temperature |
| Detection Time | ≤8 min per assay |
| LOD | 1 ppb |
| Quantitative Range | 2–150 ppb for AFB₁ and Total Aflatoxins (B₁+B₂+G₁+G₂) |
| Regulatory Alignment | Compliant with 2015 Edition of Chinese Pharmacopoeia (ChP), Section on Aflatoxin Testing for 19 TCM materials |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SKJ-IA/01 |
| Instrument Category | Multi-Mycotoxin Immunoassay Analyzer |
| Detection Principle | Lateral Flow Immunoassay with Colloidal Gold Quantification |
| Sample Throughput | 6 samples per run |
| Assay Time | 8–10 min per test |
| Display | 7-inch capacitive touchscreen |
| Integrated Thermal Printer | Yes |
| Data Connectivity | USB, Wi-Fi, Ethernet |
| Regulatory Validation | Verified by National Grain Administration Quality Inspection Center (China) for AFB1, DON, ZEN, OTA |
| Storage | Ambient (no refrigeration required for test strips) |
| Test Strip Format | Individually sealed single-use cassettes |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | SKJ-IA/02 |
| Instrument Category | Aflatoxin B1 Analyzer |
| Detection Principle | Immunochromatographic Colloidal Gold Quantification |
| Sample Throughput | 6 samples per run |
| Detection Time per Sample | ≤10 min |
| Display | 7-inch capacitive touchscreen |
| Integrated Thermal Printer | Yes |
| Test Strip Format | Individually packaged lateral flow strips, ambient storage stable |
| Regulatory Validation | Certified by the National Grain and Oils Quality Inspection Center (China) for AFB1, DON, ZEN, OTA, FB1, and T-2 toxin |
| Data Connectivity | Cloud-ready |
| Quantitation Range (AFB1) | 0–150 ppb |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | SKJ-IA/04 |
| Instrument Category | Multi-Mycotoxin Immunoassay Analyzer |
| Detection Principle | Lateral Flow Immunoassay with Colloidal Gold-Based Quantitative Signal Readout |
| Display | 7-inch Capacitive Touchscreen |
| Data Connectivity | Wi-Fi / USB / Optional Cloud API Integration |
| Sample Throughput | Up to 6 samples per run |
| Assay Time | ≤10 min per test |
| Storage Condition for Test Strips | Ambient (15–30 °C), Individually Sealed |
| Regulatory Validation | Certified by National Grain Quality Inspection Center (China) per GB/T 28717–2012 and relevant grain safety standards |
| Brand | CSY (Shenzhen Finanalysis Instruments Co., Ltd.) |
|---|---|
| Origin | Shenzhen, China |
| Model | CSY-JAZ |
| Detection Principle | Reflectometric Photometric Scanning of Lateral Flow Immunoassay Strips |
| Optical Source | 450–475 nm LED |
| Detection Speed | 240 tests/hour |
| Repeatability | ≤1% CV (using certified control strips) |
| Inter-instrument Variability | ≤3% (using certified control strips) |
| Detection Mode | Semi-quantitative & quantitative |
| Display | 7-inch true-color capacitive touchscreen (customizable to 10-inch) |
| Strip Width Compatibility | 2–6 mm (customizable) |
| Detection Channels | Single-channel (dual-, 5-, or 10-channel configurations available upon request) |
| Data Interfaces | USB 2.0, RS-232 serial, 10/100M Ethernet |
| Wireless | Integrated Wi-Fi module |
| Power Supply | 12 V DC (vehicle-compatible |
| Data Storage | Embedded high-capacity database with categorized query functionality |
| Barcode/QR Support | Optional integrated barcode scanner or QR code reader (custom OEM/ODM) |
| Line Recognition | Auto-C/T line detection with ±3 mm positional error tolerance |
| Reporting | On-screen concentration display with unit (e.g., µg/kg), thermal printer output (built-in), raw scan curve archiving |
| Regulatory Alignment | Designed to support GLP-compliant workflows |
| Brand | Hongweiliangzi |
|---|---|
| Origin | Shandong, China |
| Model | HW-LZ2 |
| Detection Principle | Fluorescent Quantitative Immunochromatography |
| Target Analytes | Aflatoxin B1 (1–100 µg/kg), Deoxynivalenol (50–5000 ppb), Ochratoxin A (2–400 µg/kg), Zearalenone (5–400 µg/kg), Fumonisin (50–6000 ppb), T-2 Toxin (2–2500 ppb) |
| Detection Time | < 5 seconds per test |
| Repeatability | CV ≤ 3% |
| Channels | 6 independent optical detection channels |
| Operating Temperature Range | Ambient +5°C to 60°C |
| Display | 7-inch capacitive touchscreen (1920 × 1200) |
| OS | Android 7.1 |
| Onboard Storage | 1 GB RAM + 8 GB eMMC |
| Data Capacity | >100,000 records |
| Connectivity | Dual USB-A, USB-B, Gigabit Ethernet, Wi-Fi 802.11 b/g/n, optional Bluetooth & RFID/QR scanning |
| Thermal Printer | Built-in (57 × 20 mm thermal paper) |
| Power Input | AC 100–240 V, 50 Hz |
| Output | DC 12 V / 5 A |
| Dimensions (H×W×D) | 308 × 205 × 91 mm |
| Net Weight | 2.7 kg |
| IP Rating | IP54 |
| Transport Case | Military-grade shock-absorbing aluminum trolley case (800 × 340 × 540 mm, 18 kg gross) |
| Brand | LANENDE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LD-DY10 |
| Instrument Category | Multi-Mycotoxin Rapid Quantitative Analyzer |
| Detection Principle | Fluorescent Lateral Flow Immunoassay (FLFIA) |
| Detection Channels | 6 independent quantitative channels |
| Fluorescence Excitation Wavelength | 365 nm |
| Detector | Silicon Photodiode |
| Sample Processing Time | ≤12 min (including extraction and assay) |
| Assay Time per Test Strip | <4 s |
| Repeatability (CV) | ≤0.8% |
| Stability (Drift) | ≤0.6% |
| Relative Standard Deviation (RSD) | ≤6% |
| Data Storage Capacity | ≥1,000,000 records |
| Operating Temperature | 5–40 °C |
| Humidity Range | 10–90% RH |
| Dimensions (W×D×H) | 300 × 240 × 125 mm |
| Net Weight | 1.7 kg |
| Power Supply | 220 V ±22 V, 50 Hz ±1 Hz |
| DC Output | 12 V / 5 A |
| Rated Power | 40 W |
| Connectivity | Dual USB-A, USB-B, RJ45 Ethernet, Wi-Fi 802.11 b/g/n, Bluetooth 4.2 |
| Brand | Santiyiqi |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ST-L01T |
| Price | USD 1,390 (approx. based on ¥9,800 at 1 USD = ¥7.1) |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TY-L01G |
| Detection Principle | Competitive Inhibition Immunoassay with Colloidal Gold Lateral Flow |
| Sample Throughput | Up to 12 tests per run |
| Display | 10.1-inch capacitive touchscreen (Android OS) |
| Processor | ARM Cortex-A7 RK3288, quad-core @ 1.88 GHz |
| Power Supply | AC/DC adapter + built-in 6 Ah Li-ion battery (field-deployable) |
| Dimensions | 43 × 35 × 20 cm |
| Net Weight | 5.1 kg |
| Data Storage | >200,000 records (local USB export to Excel) |
| Connectivity | Wi-Fi, RJ45 Ethernet, optional A4 thermal printer interface |
| Compliance Support | FDA 21 CFR Part 11–ready audit trail (user login, permission tiers, calibration lock), GLP/GMP-aligned data management |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | YT-L01G |
| Instrument Category | Integrated Immunoassay & Colorimetric Rapid Screening Platform |
| Detection Principle | Competitive Inhibition Immunochromatography (for mycotoxins) + Digital Colorimetric Analysis (for heavy metals) |
| Display | 10.1" Android-based touchscreen (ARM Cortex-A7, RK3288 quad-core, 1.88 GHz) |
| Power Supply | AC/DC dual-mode |
| Dimensions | 43 × 35 × 20 cm |
| Net Weight | 5.1 kg |
| Data Storage | >200,000 records with Excel export, user-access control, audit-trail-capable login system |
| Connectivity | Wi-Fi, RJ45 Ethernet, USB 2.0, optional A4 thermal printer interface |
| Regulatory Alignment | Designed to support GLP-compliant workflows |
