Nuclear Magnetic Resonance Spectrometer
Filter
Showing 1–30 of 42 results
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-60 |
| Operating Frequency | 60 MHz |
| Magnet Type | AlNiCo Permanent Magnet |
| Sample Form | Solid and Liquid (with appropriate probes) |
| Resolution (1H) | < 0.5 Hz |
| Sensitivity (1H) | < 0.001 mmol/L |
| Nuclei Supported | ¹H, ¹³C, ¹⁹F, ³¹P, ²³Na, ⁵⁹Co, ²⁹Si |
| Cryogen-Free Operation | Yes |
| Compliance | ASTM E2874, ISO/IEC 17025 (when operated under GLP conditions), FDA 21 CFR Part 11 (software-enabled audit trail) |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-60 |
| Operating Frequency | 60 MHz |
| Magnet Type | AlNiCo Permanent Magnet |
| Sample Form | Solid and Liquid (with appropriate probes) |
| Resolution (1H) | < 0.5 Hz |
| Sensitivity (1H) | < 0.001 mmol/L |
| Nuclei Supported | ¹H, ¹³C, ¹⁹F, ³¹P, ²³Na, ⁵⁹Co, ²⁹Si |
| Cryogen-Free Operation | Yes |
| Compliance | ASTM E2821, ISO/IEC 17025 (when operated under GLP conditions), FDA 21 CFR Part 11–ready software architecture |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-60 / EFT-90 |
| Instrument Type | Benchtop High-Field NMR Spectrometer |
| Operating Frequency | 60 MHz / 90 MHz (¹H) |
| Sample Type | Liquid Solutions |
| Resolution | < 0.5 Hz (full width at half maximum, FWHM, for 1% ethylbenzene in CDCl₃) |
| Sensitivity | ≤ 0.001 mmol/L (for ¹H, single-scan, standard 5 mm tube) |
| Magnet System | AlNiCo permanent magnet with active temperature stabilization |
| Nuclei Supported | ¹H, ¹³C, ¹⁹F, ³¹P, ²³Na, ⁵⁹Co, ²⁹Si, and other quadrupolar/nuclear spin-½ nuclei |
| Software Platform | EFT-NMR v5.x with pulse sequence library and GLP-compliant audit trail |
| Compliance | Designed to support ISO/IEC 17025, ASTM E2823, and USP <724> method validation workflows |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-60, EFT-90 |
| Operating Frequency | 60 MHz / 90 MHz |
| Sample Type | Liquid |
| Measurement Principle | Pulsed Fourier Transform NMR |
| Magnet Type | AlNiCo Permanent Magnet |
| ¹H Resolution | < 0.5 Hz |
| Sensitivity | < 0.001 mmol/L (for ¹H, standard sample) |
| Supported Nuclei | ¹H, ¹³C, ¹⁹F, ³¹P, ²³Na, ⁵⁹Co, ²⁹Si, and other quadrupolar/low-γ nuclei |
| Software Platform | EFT-NMR Console v4.x |
| Compliance | ASTM E2857, ISO/IEC 17025 (method validation support), GLP-ready audit trail logging |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-60, EFT-90 |
| Operating Frequency | 60 MHz / 90 MHz |
| Sample Type | Liquid |
| Measurement Principle | Pulsed Fourier Transform NMR |
| Magnet Type | AlNiCo Permanent Magnet |
| Resolution (1H) | <0.5 Hz |
| Sensitivity | <0.001 mmol/L |
| Nuclei Supported | ¹H, ¹³C, ¹⁹F, ³¹P, ²³Na, ⁵⁹Co, ²⁹Si, and other quadrupolar/nuclear spin-½ nuclei |
| Compliance | ASTM E2874, ISO/IEC 17025-compatible operation, GLP-ready data audit trail |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-90 |
| Operating Frequency | 90 MHz |
| Sample Type | Solid & Liquid (Broadband) |
| Magnet Type | AlNiCo Permanent Magnet |
| Resolution | < 0.5 Hz (at 90 MHz, 1H, in DMSO-d6) |
| Sensitivity | < 0.001 mmol/L (for 1H, typical small-molecule sample) |
| Cryogen-Free Operation | Yes (No Liquid Helium or Liquid Nitrogen Required) |
| Compliance | ASTM E2831-18 (Standard Guide for NMR Spectroscopy Data Reporting), ISO/IEC 17025:2017 (for lab accreditation readiness), GLP/GMP-compatible data audit trail via software |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-90 |
| Operating Frequency | 90 MHz |
| Sample Type | Solid & Liquid (with appropriate probes) |
| Magnet Type | AlNiCo permanent magnet |
| Resolution | < 0.5 Hz (for 1H at 90 MHz) |
| Sensitivity | < 0.001 mmol/L (for 1H) |
| Cooling | Zero-boil-off, helium-free operation |
| Compliance | Designed for GLP-compliant academic and industrial R&D environments |
| Software | EFT-NMR v5.x with full pulse sequence library and audit trail capability |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Ultra-High-Field NMR Spectrometer |
| Operating Frequencies | 1.1 GHz (⁴⁷/⁴⁹Ti, ¹H), 1.2 GHz (¹H) |
| Sample Compatibility | Solid–Liquid Dual-Mode |
| Acquisition Method | Pulsed Fourier Transform NMR |
| Magnet Technology | Actively Shielded Superconducting Magnet |
| Probe Options | 3 mm TCI Cryoprobe, 5 mm Triple-Axis Gradient Cryoprobe, 111 kHz MAS Solid-State NMR Probe |
| Detection Modes | Direct ¹³C and ¹⁵N Detection, Parallel Multi-Receiver Acquisition |
| Application Focus | Structural Biology, Intrinsically Disordered Proteins (IDPs), Membrane Proteins, Large Macromolecular Complexes |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A2B |
| Instrument Type | High-Field NMR Spectrometer |
| Sample Type | Solid |
| Sensitivity | Signal-to-Noise Ratio (SNR) |
| Resolution | Spectral Linewidth |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ascend Evo 1.0 GHz NMR |
| Price Range | USD $10–20 million |
| Instrument Type | High-Field NMR Spectrometer |
| Sample Compatibility | Solid-State & Solution-State |
| Operating Frequency | 1.0 GHz |
| Acquisition Mode | Pulsed Fourier Transform (PFT) & Continuous Wave (CW) |
| Brand | Bruker |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | AVANCE NEO NMR Spectrometer with Ascend Evo Magnet |
| Instrument Type | High-Field NMR Spectrometer |
| Sample Compatibility | Solid-State and Solution-State |
| Operating Frequency | 400 MHz |
| Acquisition Method | Pulsed Fourier Transform (PFT-NMR) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | High-Field NMR Spectrometer |
| Model | AVANCE NEO 500M |
| Sample Compatibility | Liquid and Solid-State (Dual-Mode) |
| Sensitivity | High Signal-to-Noise Ratio (SNR) |
| Resolution | High Spectral Resolution (Narrow Linewidth) |
| Magnet System | ASCEND™ 500 MHz Superconducting Magnet |
| Console Architecture | Integrated Embedded Acquisition Server (TopSpin 4+) |
| Compliance | GLP/GMP-ready, FDA 21 CFR Part 11–compatible software modules available |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AVANCE NEO 600M NMR Spectrometer (Ascend Evo Magnet) |
| Instrument Type | High-Field NMR Spectrometer |
| Sample Compatibility | Solid and Liquid Samples |
| Operating Frequency | 600 MHz |
| Data Acquisition Method | Pulsed Fourier Transform |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | AVANCE NEO |
| Instrument Type | High-Field NMR Spectrometer |
| Sample Compatibility | Solid-State & Solution-State (Dual-Mode) |
| Operating Frequency Range | 300–800 MHz (scalable to ≥1.25 GHz) |
| Data Acquisition Method | Pulse Fourier Transform (PFT) |
| Architecture | Integrated Transceiver-Based Digital RF Platform |
| Software Platform | TopSpin 4.x or later with Embedded Acquisition Server |
| Compliance | Designed for GLP/GMP environments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | High-Field NMR Spectrometer Software Module |
| Sample Compatibility | Solid and Liquid Samples (Unified Workflow) |
| Sensitivity | Signal-to-Noise Ratio (SNR)-Driven Analysis Validation |
| Resolution | Linewidth-Based Spectral Fidelity Assessment |
| Deployment | Native Integration with Bruker TopSpin™ and IconNMR™ Platforms |
| Regulatory Alignment | Supports GLP/GMP Documentation Requirements, FDA 21 CFR Part 11 Compliant Audit Trail (Optional Configuration) |
| Brand | Bruker |
|---|---|
| Model | CryoProbe |
| Origin | Imported |
| Cooling Principle | Closed-cycle helium refrigeration (Gifford-McMahon cryocooler) |
| Operating Temperature | ~20 K (probe coil), ~25 K (preamp) |
| Signal-to-Noise (S/N) Gain | Up to 4× vs. room-temperature probes |
| Compatible Systems | Bruker AVANCE III/IV NMR platforms |
| Probe Configurations | Dual-tuned (e.g., ¹H/¹³C), triple-resonance (e.g., ¹H/¹³C/¹⁵N), with ²H lock and Z-gradient capability |
| Compliance | Designed for GLP/GMP-compliant labs |
| Brand | Bruker |
|---|---|
| Origin | Switzerland |
| Model | DNP-NMR |
| Field Strength Options | 263 GHz / 395 GHz (corresponding to ~9.4 T and ~14.1 T for ¹H, respectively) |
| Sample Type | Solid-state and semi-solid biological macromolecules |
| Operating Temperature | ~100 K |
| Microwave Power Source | High-power gyrotron |
| Sensitivity Enhancement | 20–80× over conventional ssNMR |
| Probe Type | Cryogenic Magic Angle Spinning (MAS) probe |
| Compliance | Designed for GLP/GMP-aligned workflows with audit-trail-capable data acquisition |
| Brand | Bruker |
|---|---|
| Origin | France |
| Model | Fourier 80 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Liquid |
| Operating Frequency | 80 MHz |
| Data Acquisition Method | Pulsed Fourier Transform |
| Software | GoScan (intuitive touch interface) & TopSpin™ (advanced processing) |
| Installation | Benchtop or fume hood—no dedicated shielding, cryogen, or RF room required |
| Compliance | Designed for GLP-compliant environments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | InsightMR™ |
| Instrument Type | High-Field Online Process NMR Spectrometer |
| Sample Compatibility | Solid-Liquid Hybrid (Flow & Batch) |
| Software Platform | TopSpin®-Based Dedicated Reaction Monitoring Suite |
| Regulatory Context | Designed for GLP/GMP-Compliant Process Analytical Technology (PAT) Environments |
| Integration | Fully Compatible with Bruker Avance™ III/IV NMR Platforms |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LabScape |
| Price Range | USD 14,000 – 70,000 (est.) |
| Instrument Type | High-Field NMR Spectrometer |
| Sample Compatibility | Solid-State and Solution-State NMR |
| Sensitivity | Optimized for high signal-to-noise ratio (SNR) across standard probe configurations |
| Resolution | Tuned for high spectral resolution (line shape fidelity) in both ¹H and multinuclear experiments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Metabolic Profiler™ |
| Instrument Type | High-Field Nuclear Magnetic Resonance Spectrometer |
| Sample Format | Solid-Liquid Dual-Mode Compatibility |
| Sensitivity | Not Specified |
| Resolution | Not Specified |
| Brand | Bruker |
|---|---|
| Origin | France |
| Instrument Type | Low-Field Time-Domain Nuclear Magnetic Resonance (TD-NMR) Analyzer |
| Sample Type | Liquid |
| Operating Frequency | 20 MHz |
| Sample Preparation | None required |
| Compliance | ASTM D 7171, ASTM D 4808, ASTM D 3701 |
| Brand | Bruker |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | minispec mq |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Compatible |
| Operating Frequency | 20 MHz |
| Measurement Mode | Direct Analysis Without Sample Preparation |
| Temperature Range | –100 °C to +200 °C |
| Regulatory Compliance | 21 CFR Part 11, IQ/OQ/PQ Protocols, GLP-Compliant Operation |
| Calibration | Linear Calibration with ≥3 Samples, Chemometric Options Available |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Model | JNM-ECZL400R |
| NMR Frequency | 400 MHz (¹H) |
| Magnet Type | Superconducting, Cryogen-Free Option Available |
| Field Homogeneity | < 0.1 Hz/30 min (shimmed) |
| Temperature Control Range | –140 °C to +140 °C |
| Sample Format | Solid, Semi-Solid, Gel, Liquid, and Heterogeneous Samples |
| Probe Compatibility | Broadband Solid-State MAS Probes (e.g., 2.5–4 mm rotors), Static & Variable-Temperature Configurations |
| Optional FFC Module | SPINMASTER FFC2000 (0.01–42 MHz field-cycling range) |
| Optional SMARTracer Module | 0.1–10 MHz |
| Optional 3 T Permanent Magnet Add-on | Extends ¹H Larmor frequency to ~130 MHz |
| Sample Tube Standard | 4 mm or 3.2 mm ZrO₂ MAS rotors (solid) |
| Brand | LISICO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LS-1 |
| Price Range | USD 14,000 – 70,000 |
| Instrument Type | Low-Field TD-NMR Analyzer |
| Sample Type | Solid–Liquid Suspensions |
| Magnet Type | Samarium–Cobalt Permanent Magnet |
| Static Field Strength | 0.165 ± 0.01 T |
| Larmor Frequency | 7.0 ± 0.3 MHz |
| Frequency Tuning Range | 1–75 MHz |
| Pulse Sequences Supported | FID, Spin Echo (SE), CPMG, Saturation Recovery T₁ (Sat_T1) |
| Relaxation Time Range | 0.1 ms – 10 s |
| Probe Inner Diameter | 20 mm |
| Sample Volume | 1–5 mL |
| Measurement Repeatability | ±2% |
| Frequency Resolution | 0.28 Hz |
| Phase Accuracy | 0.09° |
| Timing Resolution | 13.3 ns |
| Sampling Rate | 75 MS/s |
| Maximum Acquisition Bandwidth | 10 MHz |
| Minimum Echo Spacing | 150 µs |
| Maximum Echo Train Length | 60,000 |
| Brand | MagQu |
|---|---|
| Origin | Taiwan |
| Model | Gyrolyzer |
| Operating Frequency Range | 1.5–15 kHz |
| Static Magnetic Field Range | 0–3 G |
| Sample Volume | < 10 mL |
| Interface | USB 2.0 |
| Compliance | Designed for educational use in accordance with IUPAC NMR pedagogy guidelines and ASTM E2834-12 (Standard Guide for Teaching NMR Principles) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | PQ001-Fiber Suspension Dispersion |
| Instrument Type | Low-Field Nuclear Magnetic Resonance (LF-NMR) Analyzer |
| Sample Type | Solid–Liquid Hybrid Systems |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 T ± 0.03 T |
| Sample Tube Dimensions | Ø24.2 mm × H25 mm |
| Measurement Time | ≤120 s per test |
| Software Architecture | Integrated GUI with Real-Time T₂ Relaxometry |
| Compliance Framework | Designed for GLP-compliant environments |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | VTMR |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Dual-Phase |
| Magnet Type | Permanent Magnet |
| Static Field Strength | 0.5 ± 0.05 T |
| Standard Temperature Range | Ambient to 130 °C |
| Optional Cryo/High-Temp Module | –100 °C to 200 °C |
| Imaging Capability | Optional |
| Core Technology | FLAT (Fast Low-Amplitude Transient) Acquisition for Short-T₂/Weak-Signal Detection |
| Primary Measurement Modes | T₁ & T₂ Relaxometry, Diffusion-Weighted Analysis, MR Imaging (optional) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | VTMR20-010V-2 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Hybrid |
| Magnet Type | Permanent Magnet |
| Static Magnetic Field Strength | 0.5 ± 0.05 T |
| Temperature Control Range (Standard) | 25–130 °C |
| Optional Cryo/High-Temp Module | –100 to 200 °C |
| Pulse Sequence | Modified Spin-Echo CPMG (MSE-CPMG) |
| Measurement Time | ≤2 min per sample |
| Detection Nucleus | ¹H |
| Applications | Crosslinking density, T₂ relaxation distribution, phase-separated water dynamics, polymer segment mobility quantification |
| Brand | NIUMAG |
|---|---|
| Origin | Canada |
| Model | NMReady-100 |
| Operating Frequency | 100 MHz (2.35 T) |
| Sample Type | Liquid |
| Magnet Type | Permanent Magnet (Cryogen-Free) |
| Nuclei Support | ¹H only or dual-nucleus (¹H/¹³C, ¹H/³¹P, ¹H/¹⁹F) |
| User Interface | Integrated LCD touchscreen with cross-platform OS compatibility (Windows/macOS/Linux) and remote access capability |
| Power Mode | Energy-saving standby mode available |
| Dimensions & Installation | Compact benchtop footprint |