| Brand | Pharmsteri (Intertek) |
|---|---|
| Origin | USA |
| Model | AccuSizer Mini |
| Detection Principle | Single Particle Optical Sensing (SPOS) with LE/LS/FX/FX-Nano Sensor Options |
| Particle Size Range | 0.15–400 µm (configurable by sensor) |
| Concentration Range | Up to 1×10⁶ particles/mL (FX/FX-Nano with auto-dilution) |
| Resolution | 512 channels |
| Minimum Detectable Size | 150 nm (FX-Nano) |
| Sample Handling | Direct, one-step, or two-step automated dilution |
| Compliance | Designed for GLP/GMP environments |
| Interface | PLC-compatible digital I/O |
| Power | 100–240 VAC, 3-phase, C14 inlet |
| Pneumatic Supply | 3.5–5.6 kg/cm² (50–80 psi) |
| Liquid Inlet/Outlet Pressure | 0.2–2.1 kg/cm² (3–30 psi) / zero-backpressure discharge |
| Dimensions | 863.6 × 355.6 × 279.4 mm (34 × 14 × 11 in) |
| Brand | Bettersize |
|---|---|
| Model | BT-Online1 |
| Measurement Principle | Mie Scattering Theory (default), Fraunhofer Diffraction Theory (optional) |
| Particle Size Range | 0.1–1000 µm |
| Accuracy & Repeatability | ≤1% D50 deviation against NIST-traceable or ISO-certified reference standards |
| Laser Source | High-power fiber-coupled laser |
| Detector Array | 68-element photodiode array (forward + side scattering) |
| Optical Design | Positive Fourier transform optical system |
| Sampling Methods | Venturi negative-pressure sampling via笛-type probe or auger sampler |
| Lens Protection | Dual-layer aerodynamic air curtain |
| Dispersing Medium | Compressed air or inert gas (N₂), 0.1–0.8 MPa |
| Test Interval | Continuous or user-defined discrete intervals (minimum 1 s) |
| Monitoring Channels | 1–4 independent process lines (1:1 to 1:4 configuration) |
| Dispersion Modes | Standard (e.g., cement) and high-energy (e.g., alumina, hard ceramic powders) |
| Ingress Protection | IP65 |
| Output Interfaces | Modbus-RTU, Modbus-TCP, 4–20 mA analog output |
| Data Security Compliance | FDA 21 CFR Part 11 (audit trail, electronic signature, role-based access) |
| Standards Compliance | ISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022, GB/T 19077–2016, ISO 13320:2009, Q/ASA 001–2021 |
| Power Supply | 100–240 VAC, 50/60 Hz, 3 A |
| Measured Parameters | Full size distribution, D10/D50/D90/D97/D98, volume-weighted mean diameter D[4,3], surface-area-weighted mean diameter D[3,2], specific surface area, and user-definable fraction content (e.g., <3 µm, 3–32 µm, >45 µm, >80 µm) |
| Brand | Bettersize |
|---|---|
| Model | BT-Online1A |
| Measurement Principle | Mie Scattering Theory (default), Fraunhofer Diffraction Theory (optional) |
| Particle Size Range | 0.1–2000 µm |
| Accuracy & Repeatability Error | ≤0.5% (D50 deviation against NIST-traceable or ISO-certified reference standards) |
| Optical System | Dual-path Fourier-optics architecture (patented forward + reverse Fourier configuration) |
| Detector Array | 92-channel photodetector (forward, side, and backward scattering) |
| Laser Source | High-power fiber-coupled laser |
| Sampling Methods | Venturi negative-pressure sampling (direct pipe insertion), auger-assisted Venturi sampling, or concentrator-enhanced Venturi sampling |
| Lens Protection | Dual-layer aerodynamic air curtain |
| typical maintenance-free interval | 12 months |
| Dispersion Medium | Compressed air or inert gas (N₂), 0.1–0.8 MPa |
| Test Interval Modes | Continuous measurement or programmable interval (minimum 1 s) |
| Monitoring Channels | 1–4 independent process lines (1-to-N configuration) |
| Dispersion Modes | Standard dispersion (e.g., cement) and high-energy dispersion (e.g., alumina, hard ceramics) |
| Enclosure Rating | IP65 |
| Output Interfaces | Modbus-RTU, Modbus-TCP, 4–20 mA analog output |
| Data Integrity Compliance | FDA 21 CFR Part 11 (audit trail, electronic signatures, role-based access control) |
| Standards Compliance | ISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022 |
| Power Supply | AC 220 V, 50/60 Hz, 200 W |
| Reporting Parameters | Full size distribution, D10/D50/D90/D97/D98, volume-weighted mean D[4,3], surface-weighted mean D[3,2], specific surface area, and user-defined size fraction contents (e.g., <3 µm, 3–32 µm, >45 µm, >80 µm) |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | BT-Online2 |
| Pricing | Upon Request |
| Measurement Range | 0.02–2000 µm |
| Principle | Mie Scattering Theory (default), Fraunhofer Diffraction Theory (optional) |
| Accuracy & Repeatability | ≤0.5% D50 deviation vs. NIST/ISO reference standards |
| Calibration | Built-in standard sample verification protocol |
| Laser Source | High-power fiber-coupled laser |
| Detector Array | 92-element photodetector array (forward, side, and backward scattering) |
| Optical Design | Patented dual-path Fourier/inverse-Fourier hybrid optical system with tilted flow cell |
| Sampling Methods | (1) Peristaltic pump + direct suction probe |
| Minimum Test Interval | 3 min (including cleaning & priming) |
| Dispersion System | 600 mL recirculating chamber |
| Purified Water System | 40 L capacity with auto-refill, temperature stabilization (±0.5 °C), and filtration |
| Solvent Recovery System | Closed-loop solvent storage, filtration, and reuse circuit |
| Monitoring Channels | 1–4 parallel process streams (1:1 to 1:4 configuration) |
| Output Interfaces | Modbus-RTU, Modbus-TCP, 4–20 mA analog output |
| Data Integrity Compliance | FDA 21 CFR Part 11 (audit trail, electronic signature, role-based access) |
| Standards Conformance | ISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022 |
| Power Supply | AC 220 V, 50/60 Hz, 200 W |
| Key Reported Metrics | D10, D50, D90, D97, D98, D[4,3], D[3,2], span, distribution trend plots |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | EyeTech Online Oil-in-Water Analyzer |
| Price | Upon Request |
| Measurement Parameters | Particle Size & Shape |
| Concentration Range | 0–2000 ppm |
| Particle Size Range | 2–300 µm |
| Accuracy | ±4% or ±4 ppm |
| Sample Temperature | 2–120 °C |
| Sample Pressure | Up to 20 bar |
| Automation Level | Fully Automatic |
| Cleaning System | Integrated Thermal Boosted Water Wash |
| Real-time Output | Alarm triggers on oil concentration threshold, particle size threshold, and wash pressure failure |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | EyeTech Online Particle Size and Shape Analyzer |
| Pricing | Available Upon Request |
| [Brand | LightQ / Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Model | Acona LE Mini |
| Pricing | Upon Request] |
| Brand | LISICO |
|---|---|
| Model | Online 1 |
| Measurement Principle | Mie & Fraunhofer Light Scattering |
| Test Range | 0.1–1000 µm |
| Repeatability Error | ≤1% (D50 of certified reference material) |
| Accuracy Error | ≤1% (D50 of certified reference material) |
| Sampling Method | Venturi-based negative-pressure sampling with anti-clogging design |
| Lens Protection | Dual-air-curtain optical protection |
| Maintenance Interval | ≥180 days |
| Laser Source | Imported semiconductor laser |
| Detector Array | 68-element photodiode array |
| Operating System | Windows |
| Communication Protocols | Modbus RTU, TCP/IP, 4–20 mA analog output |
| Dispersing Medium | Compressed air or inert gas (N₂) |
| Gas Supply | 0.4–0.8 MPa, ≥1000 L/min |
| Filtration System | 4-stage imported precision filter (particulate, oil, moisture removal) |
| Sample Throughput | 2–20 g per cycle |
| Power Supply | AC 220 V, 50/60 Hz, 90 W |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 800 × 280 × 280 mm |
| Weight | 21 kg |
| Compliance | GB/T 19077–2016, ISO 13320:2009, Q/ASA 001–2021 |
| Brand | LISICO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | Online 2 |
| Pricing | Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EasyViewer |
| Pricing | Upon Request |
| Viewing Field | 1 mm × 1 mm |
| Resolution Accuracy | 1.5 µm |
| Fiber Optic Cable Length | 3 m (standard), 13 m (with USB extender) |
| Weight | 0.66 kg (probe + fiber assembly) |
| Probe Operating Temperature | −20 °C to 135 °C |
| Maximum Pressure Rating | 0–10 bar |
| Probe Housing Material | Hastelloy C-22 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ParticleTrack G400 / G600 / G600B / G600EX |
| Measurement Principle | Focused Beam Reflectance Measurement (FBRM) |
| Particle Size Range | 0.5–2000 µm |
| Laser Class | Class 1 |
| Probe Pressure Rating | 3–300 barg (model-dependent) |
| Probe Temperature Rating | −80 to +150 °C (model-dependent) |
| Scan Speed | 2 m/s (1.2 m/s for 19 mm probe) |
| Probe Window Material | Sapphire |
| Sealing Material | Viton™ (G400), Kalrez® (G600 series) |
| Enclosure Rating | IP66 (G600B/G600EX) |
| Compliance | CE, NRTL, CB Scheme, FDA 21 CFR Part 11 (with iC Process software), GLP/GMP-ready |
| Brand | PSS (Particle Sizing Systems) |
|---|---|
| Origin | USA |
| Model | A7000 Online |
| Detection Principle | Single Particle Optical Sizing (SPOS) |
| Dilution System | Integrated Automated Dilution Module |
| Sampling Mode | Timed Automatic In-Line Sampling |
| Alarm Capability | Real-Time Threshold-Based Alerting |
| Data Output | Concentration-Compensated Raw Counts & Size Distribution |
| Compliance Framework | Supports GLP/GMP Data Integrity Requirements (21 CFR Part 11 Ready via Optional Software Configuration) |
| Brand | Pharmsteri (formerly Entegris) |
|---|---|
| Origin | USA |
| Model | SemiChem APM |
| Measurement Principle | Potentiometric Titration, Standard Addition, and Ion-Selective Electrode (ISE) Methods |
| Accuracy (Potentiometry) | ±0.2% of reading |
| Accuracy (Standard Addition) | ±2.0% of reading |
| Measurement Time | 5 min per cycle |
| Sample Volume | 0.05–5 mL |
| Max Sample Temperature | 93°C (200°F) |
| Power | 110/220 VAC, 50/60 Hz |
| Pneumatic Supply | CDA 414–552 kPa (60–80 psi) |
| DI Water Supply | 138–276 kPa (20–40 psi), 2.0 L/min |
| Drain | 3/4" NPT gravity |
| Enclosure | NEMA 4X-rated industrial housing |
| MTBF | ≥8,500 hours |
| Brand | Starwood |
|---|---|
| Model | SDW-922 |
| Measurement Principle | Light Obscuration (LO) |
| Particle Size Range | 1–600 µm |
| Sensitivity | 1 µm(c) or 4 µm(c) |
| Flow Rate | 5–500 mL/min |
| Operating Pressure | 0.1–10 MPa (up to 42 MPa with optional pressure reducer) |
| Viscosity Limit | ≤650 cSt |
| Counting Accuracy | ±0.5 ISO cleanliness code |
| Coincidence Limit | 40,000 particles/mL |
| Sample Temperature Range | 0–80 °C |
| Ambient Operating Temperature | −20–60 °C |
| Storage Temperature | −30–100 °C |
| Power Supply | AC 220 V ±10%, 50/60 Hz or DC 12–40 V |
| IP Rating | IP56 |
| Dimensions | 115 × 85 × 60 mm |
| Weight | 1 kg |
| Data Storage | 1,000 internal test records + USB external storage |
| Communication Interfaces | RS232, RS485 (Modbus RTU), USB |
| Optional Modules | Integrated temperature sensor (1–100 °C, ±1 °C), water activity sensor (1–100 %RH, ±1 %RH), absolute humidity sensor (1–360 ppm, ±1 ppm), 4G/5G remote monitoring |
| Brand | Winnova |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Winner7000 |
| Price Range | USD 14,000 – 70,000 |
| Measurement Principle | Mie Scattering Theory |
| Laser Source | He-Ne, 632 nm, 2 mW |
| Particle Size Range | 0.1–300 µm or 0.1–800 µm (configurable) |
| Sampling Methods | Mechanical / Pneumatic / Venturi |
| Return Methods | Mechanical / Pneumatic / Auto-Return |
| Dispersion Method | Turbulent Flow Dispersion |
| Lens Protection | Air Curtain |
| Cleaning Method | Timed High-Pressure Air Purge |
| IP Rating | IP54 |
| Operating Temperature | −15°C to +45°C |
| Operating Humidity | 0–60% RH (non-condensing) |
| Accuracy | < ±3% |
| Repeatability | < ±3% |
| Dimensions | 1000 × 600 × 1500 mm |
| Weight | 80 kg |
| Continuous Operation | 24/7 |
| Data Output Interface | Standard Modbus TCP, OPC UA, 4–20 mA, Ethernet |
| Cloud Integration | Optional cloud-based monitoring platform with TLS-secured data transmission |