Optical Instruments
Filter
Showing 571–600 of 1896 results
| Brand | Atometrics |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model Series | AH Series |
| Imaging Sensor | CMOS |
| XY Stage Dimensions | 220 mm × 180 mm |
| Frame Rate | 30 FPS |
| 3D Image Comparison Function | Yes |
| Maximum Optical Magnification | 500× |
| Brand | Atometrics |
|---|---|
| Model | AP-5005 |
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Pricing | Upon Request |
| Brand | ART Photonics |
|---|---|
| Origin | Germany |
| Model | newopto |
| Fiber Type | Chalcogenide (CIR) / Polycrystalline (PIR) |
| Transmission Range | 6500–1700 cm⁻¹ (CIR) / 3600–600 cm⁻¹ (PIR) |
| Max. Temp. | ≤90°C (CIR) / ≤100°C (PIR) |
| Total Length | 1 m (standard) |
| Shaft Length | 120 mm |
| Shaft Diameter | 10 mm |
| Shaft Material | PEEK |
| Protective Tube Material | PEEK |
| Connector | Long SMA (custom options available) |
| Detachable Loop Configuration | Single-loop, double-loop, triple-loop, and multi-loop variants |
| Brand | ATSEVA |
|---|---|
| Origin | Russia |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | APC Femtosecond Pulse Compressor |
| Core Component | Prism-Based Dispersion Compensation Unit |
| Wavelength Range | 700–900 nm (customizable) |
| GVD Tuning Range @ 800 nm | +16,500 to −13,800 fs² (APC Pro DF) |
| Transmission | >90% @ 800 nm |
| Beam Diameter | Up to 4 mm |
| Polarization | Linear, horizontal (vertical optional) |
| Prism Materials | Fused Silica & Dense Flint Glass |
| Dimensions (APC Pro DF) | 410 × 324 × 186 mm |
| Compliance | Designed for ultrafast laser systems compliant with ISO 11146 (laser beam parameters) and IEC 60825-1 (laser safety) |
| Brand | ATSEVA |
|---|---|
| Origin | Russia |
| Model | IRA-0.45-3 |
| Wavelength Range | 450 nm – 11 µm |
| Pulse Duration Range | 50 fs – 250 ps |
| Input Pulse Energy (typ.) | >1 nJ (50 fs–1 ps, thin NL crystal) / >3 nJ (1–250 ps, thick NL crystal) |
| Max. Avg. Input Power | 1 W |
| Repetition Rate | 10 Hz – 100 MHz |
| Polarization | Linear, horizontal |
| Delay Line Time Resolution | 8.3 fs |
| Full Scan Range | 850 ps |
| Interface | USB |
| Software | Windows-based acquisition & analysis suite |
| Dimensions (Optical Unit) | 450 × 250 × 210 mm |
| Dimensions (Control Unit) | 250 × 180 × 90 mm |
| Power Supply | 110/220 V, 50/60 Hz ±10% |
| Brand | ATSEVA |
|---|---|
| Origin | Russia |
| Model | OA |
| Dynamic Attenuation Range | >10² |
| Input Pulse Duration | <50 fs (OAFP), >50 fs (OAGP), >70 fs (OABS) |
| Center Wavelength Options | 343–350 nm, 450–1600 nm (configurable), typical: 515 nm / 800 nm / 1030 nm |
| Bandwidth | 5% (OAFP), 10–12% (OAGP/OABS) of center wavelength |
| Transmission | >92% (OAFP), >90% (OAGP), >85% (OABS) |
| Clear Aperture | <10 mm (OAFP/OAGP-10/OABS-9), <6 mm (OAGP-6), <15 mm (OABS-15) |
| Beam Walk-off | <40 mm (OAFP), <1 mrad (OAGP/OABS) |
| Damage Threshold | 10 J/cm² (OAFP/OAGP-10/OABS-15), 5 J/cm² (OAGP-6) |
| Drive Type | Manual (-M), Manual with Side Knob (-MK), or Stepper Motor–Driven USB-Controlled (-S), step resolution: 0.1% per step |
| Spectral Range | 250–2000 nm |
| Polarization-Based Attenuation Principle | Rotating Waveplate + Polarizer Architecture |
| Brand | ATSEVA |
|---|---|
| Model | OCV-6300F |
| Type | Optical Mechanical Chopper |
| Frequency Range | 7–6300 Hz (dependent on chopper blade configuration) |
| Blade Options | 2-, 10-, 30-, 60-, and 100-slot |
| Sync Output | +5 V, 50 Ω TTL-compatible |
| Frequency Accuracy | ±1 Hz |
| Power Supply | AC 100–230 V, 50/60 Hz → DC 12 V, 0.35 A adapter |
| Power Consumption | 4 W |
| Dimensions (OCV-6300F) | 87 × 104 × 148 mm (W × L × H) |
| Integrated Frequency Counter | Yes |
| Compliance | CE-marked, RoHS-compliant |
| Operating Environment | 15–35 °C, <80% RH non-condensing |
| Brand | ATSEVA |
|---|---|
| Origin | Russia |
| Model | OG-B/F |
| Core Components | Pockels Cell, High-Voltage Gate Driver, Synchronization & Delay Module |
| Wavelength Ranges | 340–1280 nm (OG-F), 200–2200 nm (OG-B), 1000–2700 nm (OG-B-R/K) |
| Max Repetition Rate | 1 MHz (OG-B-R/K), 100 kHz (OG-B), 1 kHz (OG-F) |
| Minimum Repetition Rate | Single-shot |
| Aperture | Up to 20 mm (OG-B), 6 mm (OG-F), 3.5 mm (OG-B-R/K) |
| HV Gate Pulse Width (10% level) | 3 ns (OG-F), 8 ns (OG-B), 8 ns (OG-B-R/K) |
| Rise Time (10–90%) | 700 ps (OG-F), 3.5 ns (OG-B/OG-B-R/K) |
| Contrast Ratio | >1500:1 (OG-F), >700:1 (OG-B), >800:1 (OG-B-R/K) |
| Pockels Cell Voltage | up to 10 kV (OG-F), up to 4 kV (OG-B), up to 3 kV (OG-B-R/K) |
| Transmission | >85% (standard GT prism + PC), >98% (PC only) |
| Trigger Options | Internal/External, Optical/Electrical, Edge/Level/Burst Mode |
| Channel Delay Range | 0–10 µs (OG-F), 0–1 µs (OG-B/OG-B-R/K), extendable per request |
| Cooling | Passive ≤3 kHz |
| Brand | ATSEVA |
|---|---|
| Model | SP |
| Type | Spectral Phase Interferometry for Direct Electric-field Reconstruction Instrument |
| Origin | Russia |
| Import Status | Imported |
| Interface | USB 2.0 |
| Operating Mode | Single-shot & Real-time |
| Input Polarization | Linear, Horizontal |
| Dimensions (w×d×h) | 361 × 210 × 145 mm (SP-800-5), 385 × 295 × 125 mm (SP-800-10 & SP-1000-20) |
| Spectral Range Options | 550–1050 nm |
| Transform-Limited Pulse Width Coverage | 5–12 fs to 80–320 fs (model-dependent) |
| Sensitivity | ≥1 µJ per pulse (single-shot mode) |
| Detection | Dual-channel CCD spectrometer integrated |
| Data Processing | Linear, non-iterative Fourier-domain reconstruction algorithm |
| Brand | ATSEVA |
|---|---|
| Origin | Russia |
| Model | TiC |
| Type | Solid-State CW Tunable Laser Oscillator |
| Tuning Range | 700–1000 nm (standard), extendable to 690–1060 nm |
| Output Power | >1.8 W @ 800 nm (free-space), up to 1.2 W (fiber-coupled, 4 µm core) |
| Linewidth | <45 GHz (default), <20 GHz (with one intra-cavity etalon), <2 GHz (with two intra-cavity etalons) |
| Pump Requirement | CW DPSS or Ar⁺-Ion laser at 480–550 nm (typically 532 nm), 2–10 W |
| Beam Quality | TEM₀₀, M² < 1.2 |
| Polarization | Linear, horizontal, PER > 100:1 |
| Power Stability | <0.2 % rms (12 h, after 30-min warm-up, with closed-loop chiller & certified pump laser) |
| Control Interface | USB-connected stepper motor actuation, Windows-based software suite (Basic/AU/Automatic packages) |
| Optional Features | Integrated spectrometer, power meter, active power stabilization, fiber coupling (SMF, FC connector), BRF control |
| Brand | attocube |
|---|---|
| Origin | Germany |
| Model | attoCFM I |
| Instrument Type | Cryogenic Confocal Microscope for Quantum Materials Research |
| Positioning Noise | < 0.5 nm |
| Sample Size Capacity | Ø100 mm |
| Sample Stage Travel Range | 150 µm (fine scan) / 5 × 5 × 5 mm³ (coarse positioning) |
| Temperature Range | 1.8 K – 300 K |
| Magnetic Field | Up to 12 T (vector magnet optional) |
| Vacuum Operating Range | 1 × 10⁻⁶ mbar – 1 atm |
| Optical Resolution | ~550 nm (at 635 nm, NA = 0.82) |
| Scan Area | 30 × 30 µm² @ 4 K |
| Objective | Cryo-optimized Achromatic Objective, NA = 0.82, WD = 0.7 mm |
| Expandable Modules | AFM/MFM/PFM/KPFM/ct-AFM/cryo-Raman |
| Brand | attocube |
|---|---|
| Origin | Germany |
| Model | attoCFM I |
| Instrument Type | Magnetic Force Microscope (MFM) / Cryogenic Confocal Microscope |
| Positioning Noise | < 0.5 nm |
| Sample Size Capacity | Ø100 mm |
| Sample Stage Travel Range | 150 µm (fine scan) / 5 × 5 × 5 mm³ (coarse positioning) |
| Temperature Range | 1.8 K – 300 K |
| Magnetic Field | Up to 12 T (vector magnet optional) |
| Vacuum Operation | 1 × 10⁻⁶ mbar – 1 atm |
| Numerical Aperture (NA) | 0.82 |
| Optical Resolution | ~550 nm (@635 nm) |
| Working Distance (WD) | 0.7 mm |
| Confocal Scan Range | 30 × 30 µm² @4 K |
| Compatible Cryostats | attoDRY1000/2100, Quantum Design PPMS (1″/2″ bore) |
| Expandable Modules | AFM/MFM/PFM/KPFM/ct-AFM/cryo-Raman |
| Brand | attocube Systems AG |
|---|---|
| Origin | Germany |
| Product Type | Motorized Translation Stage |
| Model | oPOSITIONING |
| Operating Temperature Range | 10 mK to 373 K |
| Magnetic Field Compatibility | Up to 31 T |
| Vacuum Compatibility | Down to 5×10⁻¹¹ mbar |
| Closed-Loop Positioning Resolution | 1 nm |
| Maximum Travel Range | 50 mm |
| Minimum Stage Footprint | 11 × 11 mm |
| Load Capacity | Up to 2 kg |
| Typical Step Size | 50 nm at 300 K, 10 nm at 4 K (linear actuators) |
| Control Options | Open-loop, RES (resistive sensor), or NUM (optical encoder) feedback |
| Brand | Attocube Systems AG |
|---|---|
| Origin | Germany |
| Model | ANR101/RES |
| Product Type | Motorized Translation Stage |
| Operating Temperature Range | 10 mK – 373 K |
| Magnetic Field Compatibility | 0 – 31 T |
| Vacuum Compatibility | Ambient – 5×10⁻¹¹ mbar |
| Closed-Loop Positioning Resolution | 1 nm |
| Maximum Travel Range | 50 mm |
| Minimum Stage Footprint | 11 × 11 mm |
| Load Capacity | Up to 2 kg |
| Actuation Voltage | 60 V or 150 V (low-voltage compatible) |
| Material | Beryllium Copper (BeCu) |
| Compliance | Designed for GLP/GMP-aligned quantum transport & optical spectroscopy workflows requiring traceable positioning under cryogenic, ultra-high vacuum, and high-field conditions |
| Brand | Attocube Systems AG |
|---|---|
| Origin | Germany |
| Product Type | Motorized Translation & Rotation Stage |
| Model | atto3DR |
| Sample Mounting Area | 4.9 mm × 4.9 mm × 1.2 mm |
| Electrical Contacts | 20-pin Chip Carrier Interface |
| Angular Range | ±90° per axis (mechanical reserve: ±10°) |
| Minimum Step Size | 1 m° @ 300 K |
| Max. Rotation Speed | ~30°/s @ 300 K |
| Feedback Sensor | Resistive Encoder |
| Encoder Resolution | ~6 m° |
| Repeatability | ~50 m° |
| Linearity Error | ~1% |
| Compatible Cryostat Environment | Dilution Refrigerators (down to <20 mK), He atmosphere |
| Plug-and-Play Integration | Yes |
| Control Interface | GUI & LabVIEW API |
| Brand | attocube Systems AG |
|---|---|
| Origin | Germany |
| Model | attoCFM I |
| Instrument Type | Point-Scanning Confocal Microscope |
| Temperature Range | 1.8 K – 300 K |
| Magnetic Field | Up to 12 T (vector magnet optional) |
| Vacuum Range | 1×10⁻⁶ mbar – 1 atm |
| Numerical Aperture (NA) | 0.82 |
| Optical Resolution | ~550 nm (@635 nm) |
| Coarse Sample Positioning | 5 × 5 × 5 mm³ |
| Fine Scan Range | 30 × 30 µm² @ 4 K |
| Working Distance | 0.7 mm |
| Compatible Cryostats | attoDRY1000/2100, Quantum Design PPMS (1" & 2" bore) |
| Brand | Attocube Systems AG |
|---|---|
| Origin | Germany (manufactured in Germany |
| Instrument Type | Research-grade industrial SPM platform |
| Magnet Strength | Up to 15 T |
| Temperature Range | 1.5 K – 300 K (continuous, closed-cycle) |
| Positioning Noise | < 0.5 nm RMS |
| Sample Dimensions | Max 100 mm × 50 mm × 20 mm |
| XY Scanner Range | 10 µm × 10 µm |
| Vibration Level | 0.12 nm RMS (typical) |
| Compliance | ASTM E2579, ISO/IEC 17025 compatible operation environment |
| Software Control | Integrated touchscreen interface with automated temperature/magnetic field ramping |
| Brand | Attocube Systems AG |
|---|---|
| Origin | Germany |
| Model | attoDRY Lab |
| Instrument Type | Cryogenic Scanning Probe Microscope (SPM) |
| Magnetic Field Strength | Up to 15 T |
| Temperature Range | 1.5 K – 300 K (closed-cycle) |
| Positioning Noise | < 0.5 nm RMS |
| Sample Dimensions | Max 100 mm × 50 mm × 20 mm |
| XY Scanner Range | 10 µm × 10 µm |
| Vibration Level | 0.12 nm RMS (typ.) |
| Compliance | ASTM E2917, ISO/IEC 17025 compatible workflows, GLP/GMP-ready data logging |
| Brand | attocube Systems AG |
|---|---|
| Origin | Germany |
| Product Type | Motorized Translation Stage |
| Model | attoECS |
| Travel Range | up to 50 mm |
| Minimum Step Size | 50 nm (open-loop), 10 nm (closed-loop with optical encoder) |
| Repeatability | ±200 nm |
| Accuracy | <0.01% of full scale |
| Load Capacity | up to 240 N (24 kg) |
| Operating Environment | Ambient air, dry nitrogen, or ultra-high vacuum (UHV) compatible |
| Drive Voltage | <45 V |
| Encoder Resolution (optional) | 1 nm |
| Dimensions (min) | 30 × 30 × 9.5 mm³ |
| Compliance | ISO 9001 certified manufacturing |
| Brand | Attocube Systems AG |
|---|---|
| Origin | Germany |
| Model | attoDRY Lab |
| Instrument Type | Magnetic Force Microscope (MFM) |
| Positioning Noise | 0.12 nm RMS |
| Sample Stage Travel Range | 5 mm × 5 mm × 5 mm |
| Temperature Range | 1.5 K – 300 K (configurable) |
| Maximum Magnetic Field | 15 T |
| Cooling Time (to base temperature) | ~1–2 hours |
| Control Interface | Integrated touchscreen with automated thermal and magnetic field sequencing |
| Brand | AULTT |
|---|---|
| Model | AULTT-P |
| Type | Compact USB-Powered CCD Spectrometer with UV-VIS-NIR Coverage |
| Origin | Beijing, China |
| Manufacturer | Zhongjiaojinyuan (CNI) |
| Component Category | Light Source–Integrated Spectral Measurement System |
| Key Specifications | 185–1100 nm spectral range (model-dependent), 0.03 nm optical resolution, <0.3 nm wavelength repeatability, 30 µm slit, 600 lines/mm grating (optimized for UV or VIS), 2048- or 3648-pixel linear silicon CCD detector, USB 2.0 bus-powered operation |
| Software | Win7-compatible spectral acquisition & analysis suite with multi-instrument support, real-time exposure control, spectral video capture, and export to CSV, TXT, PDF, BMP |
| Compliance | Designed for laboratory-grade optical metrology in R&D, QA/QC, and educational environments |
| supports ASTM E308, CIE 15 | 2018, ISO/CIE 11664, and GLP-aligned data traceability (audit trail enabled in software log) |
| Brand | AULTT |
|---|---|
| Model | P2000 |
| Detector | 2048-pixel linear silicon CCD |
| Wavelength Range | 350–1000 nm |
| Optical Resolution (FWHM) | ≤ 0.03 nm |
| Wavelength Repeatability | < ±0.3 nm |
| Slit Width | 30 µm |
| Grating | 600 lines/mm @ 450 nm |
| Interface | USB 2.0 |
| Power Supply | Bus-powered via USB |
| Operating System | Windows 7 and later |
| Software | Integrated spectral analysis suite with multi-instrument support, exposure auto-adjustment, spectral video capture, and export to CSV, TXT, PDF, BMP |
| Brand | AULTT |
|---|---|
| Model | P3000 |
| Detector | 3648-pixel linear silicon CCD |
| Wavelength Range | 200–800 nm (UV-Vis) |
| Optical Resolution (FWHM) | ≤ 0.03 nm |
| Wavelength Repeatability | < ±0.3 nm |
| Slit Width | 30 µm |
| Grating | 600 lines/mm, blazed at 250 nm |
| Interface | USB 2.0, bus-powered |
| Software Compatibility | Windows 7 and later |
| Data Export Formats | CSV, TXT, PDF, BMP |
| Spectral Acquisition Modes | Single-shot, continuous scan, spectral video |
| Calibration | Factory NIST-traceable wavelength & radiometric calibration |
| Compliance | CE, RoHS |
| Accessories Support | Modular fiber-optic coupling (SMA905), interchangeable light sources (deuterium, tungsten-halogen, LED), cuvette holders, integrating spheres, and filter kits |
| Brand | AULTT |
|---|---|
| Model | P4000 |
| Detector | 3648-pixel linear silicon CCD |
| Wavelength Range | 185–1100 nm |
| Optical Resolution (FWHM) | ≤0.03 nm |
| Wavelength Repeatability | < ±0.3 nm |
| Slit Width | 30 µm |
| Grating | 600 lines/mm, blazed at 250 nm |
| Interface | USB 2.0, bus-powered |
| Software Compatibility | Windows 7 and later |
| Compliance | CE-marked optical instrumentation, compliant with IEC 61326-1 for EMC in laboratory environments |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FiberAut-S520 |
| Pricing | Available Upon Request |
| Pressure Range (gauge) | 300 mmHg / 1500 mmHg (max) |
| Temperature Range | 20–50 °C (customizable) |
| Pressure Accuracy | ±1% FS |
| Temperature Accuracy | ±1 °C |
| Pressure Resolution | 0.01% FS (with compatible readout unit) |
| Temperature Resolution | 0.1 °C (with compatible readout unit) |
| Sensor Dimensions | Ø260 µm × 1.3 mm |
| Fiber Connector | SC/PC |
| Packaging Options | Glass Capillary / Stainless Steel Tube / Polyimide (PI) Tube |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Optical Instrument Component / Fiber Optic Coupler |
| Model | GalvoStation (Microscopy & Imaging Accessory) |
| Pricing | Available Upon Request |
| Component Type | Tapered Fiber Probe with Galvanometric Scanning Assembly |
| Brand | Auniontech (IPOptica) |
|---|---|
| Clear Aperture | Up to 70 mm |
| Operating Wavelength | 405–1100 nm (model-dependent) |
| Peak Rotation | 45° ± 0.5° |
| Damage Threshold | >7 J/cm² @ 10 ns (HPKT), >10 J/cm² @ 10 ns (HPTG), 3 J/cm² @ 10 ns (VITG) |
| Transmission | >98% (rotator), >96% (isolator) |
| Isolation | >35 dB (HPTG/HPKT), >30 dB (VITG) |
| Storage Temperature | −40°C to +70°C |
| Beam Pointing Stability | <5 mrad |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | AFM-Portable Series |
| Pricing | Available Upon Request |
| Brand | Auniontech |
|---|---|
| Origin | Canada |
| Model | NS/ASN Series |
| Wavelength Range | 514–1550 nm |
| Pulse Width | 0.7–1.5 ns |
| Avg. Power | 0.5–10 W |
| Cooling | Air-cooled |
| Beam Quality (M²) | <1.1 |
| Timing Jitter | <10 ps RMS |
| Trigger Mode | Internal/External TTL |
| Compliance | CE, RoHS, FDA 21 CFR Part 11 (Software Optional) |
| Brand | Auniontech |
|---|---|
| Model | SWIR |
| Imaging Range | Short-Wave Infrared (900–1700 nm) |
| Magnification | 67× to 1000× |
| Illumination Options | Coaxial LED, Laser, Broadband Sources |
| Configuration Types | Upright & Horizontal |
| Dual-Channel Capability | Yes |
| Application Focus | Semiconductor Inspection, In Vivo SWIR Fluorescence Imaging, Forensic Analysis, Cultural Heritage Examination |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments, supports GLP/GMP documentation workflows |