| Brand | ANJIE |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-6100 |
| Instrument Type | Automated Iodine-Specific Elemental Analyzer for Urine, Water and Salt Matrices |
| Regulatory Context | Designed for compliance with WS/T 107.1–2016 (China), ISO 8468:1996 (Water Quality – Determination of Iodide), and USP <232>/<233> elemental impurities guidance frameworks |
| Cooling Method | Integrated Peltier-based water bath refrigeration |
| Digestion Architecture | Graphite block digestion with reflux condensation |
| Reagent Consumption | Optimized for ≤1.5 mL per sample (standard protocol) |
| Throughput | Up to 48 samples per batch (with optional autosampler) |
| Safety Compliance | Meets GB/T 18204.1–2013 (Public Health Inspection Standards) for laboratory ventilation integration |
| Brand | analytik jena |
|---|---|
| Origin | Germany |
| Model | multi EA 5100 |
| Detection Elements | C, N, S, Cl |
| Furnace Configurations | Dual-mode vertical & horizontal combustion furnace |
| Detector Technology | HiPerSens® electrochemical and thermal conductivity detection |
| Sample Forms | Solid, liquid, gaseous & supercritical fluid |
| Automation | Fully automated direct injection |
| Compliance | Designed for GLP/GMP environments |
| Safety Systems | Integrated self-diagnostic module, flame sensor (horizontal mode), aerosol/liquid ingress protection, auto-leak monitoring, active gas stream drying & purification |
| Brand | DAJ |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | WGJ-III |
| Pricing | Upon Request |
| Brand | Eraly & Associés |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HELIOS CL |
| Price | Upon Request |
| Measurement Principle | Coulometric Titration (Absolute Method) |
| Sample Types | Liquids (including viscous), Gases (incl. LPG), Solids, Slurries, Polymers, Fuels, Environmental Matrices |
| Compliance | ASTM D4929, ASTM D5808, ASTM D5194, ASTM D6721, GB/T 18612, SH/T 1757, GB/T 23971-B, SH/T 0677-A, UOP 779, ISO 9562, NF EN 12260, NF EN 14077 |
| Detection Range | 0.1 ppm to 80 wt% Cl (matrix-dependent, no dilution required) |
| Electrolyte Options | Three grades for low-, medium-, and high-concentration applications |
| Dual-Cell Architecture | Two independent coulometric titration cells |
| Furnace | F2-type high-temperature combustion furnace, max. 1100 °C |
| Carrier Gases | O₂ (99.998%, 3 bar) and Ar (99.995%, 3 bar) |
| Sample Introduction | 20–80 µL liquid |
| Power Supply | 110/230 V, 50/60 Hz, 800 W |
| Dimensions (W×H×D) | 66 × 83 × 56 cm |
| Weight | 32 kg |
| Warranty | 5-year hardware warranty |
| Language Interface | English, French, Spanish, German, Russian, Chinese |
| Safety Features | Automated acid-free dry/wash system, light-shielded semi-pressurized titration cell, integrated gas flow control and pressure monitoring |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERAOIL |
| Type | Rotating Disk Electrode Optical Emission Spectrometer (RDE-OES) |
| Detection Principle | Arc Spark Optical Emission Spectrometry |
| Measurement Time | ≤30 s per sample |
| Elements Quantified | Up to 32 metallic elements |
| Detection Limit (LOD) | Sub-ppm for most elements (standard configuration) |
| Sample Types | Lubricants, fuels, coolants, process water, hydraulic fluids |
| Compliance | ASTM D6728, ASTM D6595, NB/SH/T 0865 |
| Integrated System | Built-in 10-inch color touchscreen, embedded industrial PC, automated electrode dresser, and active ventilation unit |
| Dimensions & Portability | Compact benchtop footprint |
| Sample Preparation | None required — direct liquid analysis |
| Gas Requirement | None (no carrier gas, no plasma gas) |
| Brand | Hongweiliangzi |
|---|---|
| Origin | Shandong, China |
| Model | HW-DYS2 |
| Measurement Channels | 6 |
| Sample Throughput | 20 consecutive samples |
| Analysis Time per Sample (8 elements) | ≤5 min |
| Stability | ±1 digit within 5 min |
| Compliance Standards | GB/T 4734, GB/T 6900, QB/T 2578–2002 |
| Operating Temperature | 10–30 °C |
| Relative Humidity | ≤85% |
| Power Supply | 220 V, 50/60 Hz |
| Power Consumption | 1 kW |
| Dimensions (Instrument) | 500 × 460 × 350 mm |
| Weight (Instrument + Packaging) | 15 kg |
| Brand | HORIBA |
|---|---|
| Origin | Imported |
| Manufacturer | HORIBA, Ltd. |
| Model | EMGA-Expert |
| Detection Principle | Pulse Heating Extraction + NDIR (CO/CO₂, H₂O) & TCD (N₂) |
| Gas Detection Methods | Non-Dispersive Infrared (NDIR) for O and H |
| Automation Options | Auto-Sampler, Auto-Crucible Loader, Auto-Electrode Cleaner, Halogen Trap |
| Compliance Support | ASTM E1019, ISO 14284, ISO 22356, JIS G 1257, USP <233>, FDA 21 CFR Part 11 (audit trail enabled), GLP/GMP-ready software architecture |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Easy Na |
| Measurement Principle | Potentiometric Standard Addition Method (Sodium-Selective Electrode, Non-Calibration Required) |
| Compliance | Designed for GB 28050–2011 nutritional labeling requirements |
| Software Integration | EasyDirect™ Data Acquisition Software |
| Reagent System | NaCl-based ISA (no AgNO₃ required) |
| Target Matrix | Food & Beverage samples (liquid, homogenized, or acid-digested) |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | NX-200S |
| Pricing | Upon Request |
| X-ray Tube | 70 kV end-window micro-focus tube |
| Detector | Imported integrated Si-PIN detector, energy resolution ≤125 eV at 5.889 keV |
| Sample Form | Dry, homogenized powder (no digestion required) |
| Detection Limits (3σ, mg/kg) | Cd 0.16 |
| Battery Life | 8–10 h per charge (removable Li-ion) |
| Operating Temperature | −20 °C to +40 °C |
| Dimensions | 260 W × 350 L × 300 H mm |
| Weight | <4.5 kg |
| Compliance | GBZ 115–2002 (X-ray safety), GB 15618–2018 (Soil Risk Control Standard) |
| Brand | AMS |
|---|---|
| Origin | Beijing, China |
| Model | NexaFlo™ |
| Configuration | Up to 14 independent analytical channels |
| Detection Principles | Continuous Flow Analysis (CFA) with segmented flow, online pre-treatment (dialysis, UV digestion, distillation, heating, dilution, mixing, extraction) |
| Detector Options | UV-Vis spectrophotometer, flame photometer (for K⁺/Na⁺), fluorimeter |
| Display | 7-inch color touchscreen (NexaFlo™ 450 variant) |
| Automation | Fully programmable CFA software with auto-startup/shutdown, QC control, auto-dilution, LIMS export, and audit-trail-capable operation |
| Compliance | Designed to support ASTM D129, ISO 11905-1, USP <621>, EPA Methods 353.2, 354.1, 365.2, and GLP/GMP-aligned data integrity practices |
| Sample Handling | Dual-probe autosampler optional |
| Fluidics | High-precision three-speed peristaltic pumps |
| Reagent Management | Integrated sealed reagent reservoirs with vapor/leak mitigation |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | AZtecLive |
| Detector Active Area | Up to 170 mm² |
| Maximum Quantitative Count Rate | 400 kcps |
| Maximum Mapping Count Rate | 1,000 kcps |
| Detector Type | Silicon Drift Detector (SDD) with Extreme Electronics Architecture |
| Compliance | Designed for integration with field-emission and tungsten SEM platforms per IEC 61000-4 EMC standards |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | CN802 |
| Detection Principle | High-Temperature Combustion (Dumas Method) coupled with NDIR CO₂ detection and TCD N₂ detection |
| Sample Throughput | Up to 30 samples unattended |
| Sample Form | Solid and liquid (up to 1 g) |
| Carrier Gases | Helium or Argon (switchable without hardware modification) |
| Compliance | AOAC, AACC, ASBC, ISO, DIN, IFFO, OIV, ASTM, EPA |
| Detection Technologies | NDIR for CO₂, LoGas™ TCD for N₂ |
| Moisture Removal | DriStep™ integrated desiccant system |
| Automation | 30-position autosampler (expandable to 90 positions with additional trays) |
| Software Platform | CNSoft™ + Ermes Cloud Connectivity |
| Regulatory Support | Audit trail, user management, electronic signatures (21 CFR Part 11 ready) |
| Brand | Youyunpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YP-DYS2 |
| Price | USD 2,350 (FOB Qingdao) |