Other Gas Detection Instruments
Filter
Showing 31–45 of 45 results
| Brand | ARA |
|---|---|
| Origin | USA |
| Model | N-FRM |
| Flow Rate | 10–20 LPM (nominal 16.7 LPM) |
| Flow Accuracy | ±2% (±1% with calibration) |
| Operating Time | >30 hours on rechargeable 18 V lithium battery |
| Charging Time | 1 hour |
| Data Output | USB flash drive |
| Dimensions | 25.4 × 30.48 × 17.78 cm |
| Sampling Weight | 15 lbs |
| Shipping Weight | 25 lbs |
| Filter Holder | Standard FRM-compliant 47 mm cassette mount |
| Particle Separation | Low-maintenance, oil-free cyclonic inlet for PM₂.₅ and PM₁₀ |
| Brand | ARA |
|---|---|
| Origin | USA |
| Model | N-FRM |
| Flow Rate | 10–20 LPM (nominal 16.7 LPM) |
| Flow Accuracy | ±2% (±1% with calibration) |
| Operating Time | >30 hours on rechargeable 18 V lithium battery |
| Charging Time | 1 hour |
| Data Output | USB flash drive interface |
| Dimensions | 25.4 × 30.48 × 17.78 cm |
| Sampling Weight | 15 lbs |
| Shipping Weight | 25 lbs |
| Filter Holder | Standard FRM-compliant 47 mm cassette mount |
| Particle Separation | Low-maintenance, oil-free cyclonic inlet for PM₂.₅ and PM₁₀ |
| Brand | Axetris |
|---|---|
| Origin | Switzerland |
| Model | LGD Series |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Target Gases | NH₃, CH₄, H₂O, CO₂, HCl, HF, O₂ |
| Design | OEM-ready modular optical sensor |
| Operating Temperature Range (Heated Option) | Up to 190 °C |
| Measurement Type | Non-contact, in-situ, continuous |
| Cross-Interference | Negligible due to spectral selectivity |
| Calibration | Factory-calibrated |
| Compliance Context | Designed for integration into systems compliant with IEC 61508 (SIL2-capable architectures), EN 14181 (QAL3), and EPA Method 205/207 (for extractive TDLAS configurations) |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | MGA-3000 |
| Detection Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Target Analytes | Ethyl Mercaptan, Tetrahydrothiophene (THT), Acrylic Ester |
| Measurement Range | 0–100 ppm |
| Accuracy | ±1 ppm or ±2% of reading (whichever is greater) |
| Zero/ Span Drift | ≤±2% FS/24 h |
| Response Time (T90) | ≤90 s |
| Sampling Method | Extractive |
| Output Interfaces | 4–20 mA, RS-232 / RS-485, USB, Ethernet |
| Enclosure Rating | IP65 |
| Explosion Protection | Ex d IIB T4 Gb |
| Power Supply | 220 V AC |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MGA-6000 |
| Sampling Method | Extractive |
| Power Supply | 220 V AC |
| Explosion Protection | Ex d IIB T4 |
| Ingress Protection | IP65 |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Target Analytes | Ethyl Mercaptan, Tetrahydrothiophene (THT), Acrylic Ester |
| Measurement Range | 0–100 ppm |
| Response Time (T90) | ≤60 s |
| Accuracy | ±1 ppm or ±1% of reading (whichever is greater) |
| Zero/ Span Drift | ≤±1% FS / 24 h |
| Output Interfaces | 4–20 mA, RS-232 / RS-485, USB, Ethernet |
| Brand | BGI |
|---|---|
| Origin | USA |
| Model | Bios Defender 510 & 520 |
| Certification | ISO/IEC 17025 Accredited by NVLAP (NIST) |
| Operating Temperature Range | –20 °C to +50 °C |
| Display | Backlit LCD with Navigation Menu |
| Connectivity | RS-232 Serial Interface |
| Compliance | RoHS Directive 2011/65/EU |
| Flow Units | mL/min, L/min, cc/min, CFM |
| Data Logging | Up to 100+ readings with user-defined intervals (1–60 min) |
| Integrated Sensors | Built-in temperature sensor and pressure transducer (Defender 520 only) |
| Software | PC-based calibration data acquisition, curve plotting, report generation, and GLP-compliant audit trail export |
| Brand | Eranntex |
|---|---|
| Model | MS500-MEK |
| Detection Principle | Electrochemical (Standard), Optional IR/PID/Catalytic/Thermal Conductivity |
| Gas Measured | Methyl Ethyl Ketone (MEK, C₄H₈O) |
| Display | 2.5" HD Color TFT Screen |
| Protection Rating | IP66 |
| Ingress Protection | Dust-tight & Powerful Water Jet Resistant |
| Explosion Protection | Intrinsically Safe (Ex ib IIB T4 Gb) |
| Operating Temperature | −40 °C to +70 °C |
| Battery | Rechargeable 6000 mAh Polymer Li-ion |
| Runtime | Up to 20 h (typical, single-gas, pump off) |
| Data Storage | 100,000 entries (expandable) |
| Communication | USB, RS232, Bluetooth (optional) |
| Sampling Method | Built-in Pump with >10 m Sampling Distance |
| Filtration | Integrated Water Vapor & Particulate Filter |
| Calibration | Multi-point Target Gas Calibration |
| Compliance | CMC Certified (China Metrology Accreditation), GB/T 34004–2017, GB 12358–2006 |
| Alarm Modes | Visual (LED/Screen), Audible (≥85 dB), Vibration, Undervoltage & Fault Indication |
| Units | ppm, mg/m³, %LEL, %Vol (auto-converted via molecular weight input) |
| Humidity & Temp Measurement | Optional Integrated Sensor (±2% RH, ±0.5 °C) |
| Software Support | PC-based Data Analysis Suite with Audit Trail, Export (CSV/XLS), Print & Trend Graphing |
| Brand | Eranntex |
|---|---|
| Model | PTM600-HBr |
| Detection Principle | Electrochemical (standard), Optional IR/PID/TC/Catalytic Combustion |
| Detection Range | 0.001 ppm to 99.999 %Vol (auto-ranging, specified at order) |
| Resolution | 0.001 ppm (low-range), 0.001 %Vol (high-range) |
| Display | 3.5-inch HD color TFT screen |
| Protection Rating | IP66 |
| Ingress Protection | Dust-tight, powerful water jet resistant |
| Safety Certification | Intrinsically Safe (Ex ib IIB T4 Gb), CMC Certified |
| Sampling Method | Built-in explosion-proof diaphragm pump with integrated hydrophobic particulate filter |
| Sampling Distance | >10 m (with standard sampling hose) |
| Data Storage | Standard 100,000 records (expandable via SD card or USB mass storage) |
| Communication Interfaces | USB 2.0, RS232, Bluetooth 5.0 |
| Power Supply | 10,800 mAh Li-polymer battery (rechargeable via USB, supports hot-swap operation) |
| Operating Temperature | −40 °C to +70 °C (instrument) |
| Environmental Compensation | Integrated capacitive digital temperature/humidity sensor (optional) with real-time sensor compensation |
| Alarm Types | Dual-level (low/high), range, TWA, STEL |
| Calibration | Multi-point span calibration, zero auto-tracking, calibration log with timestamp and operator ID |
| Compliance | Meets GB/T 34004–2017, JJG 693–2011, ISO 16000-25, ASTM D6792, and supports 21 CFR Part 11 audit trail when used with compliant host software |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | AQMS-200 |
| Pricing | Available Upon Request |
| Brand | GTI |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | GTI 660 |
| Pricing | Upon Request |
| Display | 3.2-inch high-resolution color LCD (Chinese UI) |
| Pressure Range | 0–500 Pa (±0.5% of reading ±1 Pa, 0.1 Pa resolution) |
| Airflow Range | 1–60 m³/h (±3% of reading ±0.5 m³/h, 0.01 m³/h resolution) |
| Atmospheric Pressure Range | 70–130 kPa (±2% of reading, 0.1 kPa resolution) |
| Temperature Range | 0–60 °C (±0.5 °C, 0.1 °C resolution) |
| Power Supply | AC 220 V for blower unit |
| Blower Unit Weight | ~10 kg |
| Control Host Weight | ~250 g (excl. batteries) |
| Dimensions (Blower) | 370 × 295 × 315 mm |
| Dimensions (Packaging) | 590 × 350 × 500 mm |
| Communication | RS485, Wi-Fi |
| Compliance | GB/T 7106–2019, JG/T 211–2007, GB/T 31433–2015 |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYK-102S |
| Light Source | High-Brightness LED |
| Wavelength | 635 nm |
| Detection Limit | 0.005 mg/m³ |
| Measurement Range | 0.000–0.100 mg/m³ (40 L sampling volume) or 0.000–0.800 mg/m³ (5 L sampling volume) |
| Accuracy | ±5% |
| Power Supply | AC 220 V ±22 V, 50 Hz ±1 Hz |
| Dimensions | 310 × 225 × 125 mm |
| Weight | 1.7 kg |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | MIC-500S-MEK |
| Output Options | 4–20 mA (3-wire or 4-wire), 0–5/0–10 V, RS485 (Modbus RTU), Dual Relay Outputs |
| Communication | Wired, LAN, Internet, Wireless (433 MHz, GPRS, Wi-Fi, Custom RF) |
| Remote Operation | Infrared remote control (15 m range, intrinsically safe operation without opening enclosure) |
| Calibration | Auto-zero tracking, multi-point calibration support |
| Certifications | CPA Type Approval (China), Ex d IIC T6 Gb explosion-proof certification, EMC/EMI compliant (GB/T 18268, GB/T 17626 series), Anti-static & reverse-polarity protected |
| Sensor Options | Electrochemical, Catalytic Bead, NDIR, PID, Thermal Conductivity (selectable from Honeywell, Figaro, City Technology, Alphasense, Dynament, Membrapor) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | NOA-7000 / CGT-7000 / SOA-7000 |
| Pricing | Available Upon Request |
| Measurement Accuracy | ±0.5% of Full Scale |
| Weight | ~14.5–15 kg |
| Brand | Starwood |
|---|---|
| Model | 3000-0C |
| Detection Principle | Condensation Particle Counter (CPC) |
| Particle Size Range | 0.02–1.0 µm |
| Concentration Range | 0–100,000 particles/cm³ |
| Sample Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Calculation | Direct Cout/Cin Ratio |
| Challenge Agent | Isopropanol (≥99.5%) or Ethanol |
| Display | 7-inch True Color Touchscreen |
| Operating Temperature | 10–35 °C |
| Relative Humidity | 20–85% RH (non-condensing) |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm (W×H×D) |
| Weight | 2.3 kg |
| Compliance Standards | OSHA 1910.134, CSA Z94.4, ANSI/AIHA Z88.10, UK HSE INDG479, GB 19083–2010, GB 2626–2019, GB/T 32610–2016 |
| Connectivity | USB, Ethernet, Wi-Fi |
| Software Compatibility | Windows 7/8/10, .NET Framework 3.5 |
| Data Export Format | Microsoft Excel |
| Storage Media | USB flash drive |
| Language Options | English, Chinese, Japanese, French, Spanish, Portuguese |
| Brand | VCAM |
|---|---|
| Model | ROS-1000 |
| Measurement Range (O₂) | 0–4000 ppm |
| Accuracy (O₂) | ±3% FS or ±5 ppm (whichever is greater) |
| Temperature Range | −50 to 700 °C |
| Temp Accuracy | ±0.5 °C |
| Temp Resolution | 0.1 °C |
| Sampling Interval | 0.05–60 s |
| Thermal Insulation | 8 min @ 300 °C / 10 min @ 260 °C |
| Vibration Sensing | Triaxial (X/Y/Z), ±2 g, ±5% accuracy, 1 mg resolution |
| Data Storage | 30 profiles × 20 minutes each |
| Carrier Width Adjustment | 141–310 mm |
| Dimensions (Probe) | 183 × 48 × 21 mm |
| Insulation Box | 242 × 90 × 34 mm |
| Power | USB-C, 5 V/1 A |
| Battery Life | 60 min |
| OS Compatibility | Windows 7 64-bit or later |