Other General Analysis Instruments
Filter
Showing all 27 results
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Heating Methods | Infrared & High-Frequency Induction |
| Temperature Range | −150 °C to 1350 °C |
| Sample Geometry | Ø3 mm × 10 mm (cylindrical) |
| Max. Heating Rate | 100 °C/s (RT → 1350 °C) |
| Max. Cooling Rate | −80 °C/s (1350 °C → 400 °C, He gas quench) |
| Sub-ambient Capability | Liquid nitrogen cooling to −150 °C |
| System Footprint | ~1300 mm W × 1000 mm D × 1700 mm H |
| Compliance | Designed for ASTM E831, ISO 11357-6, and JIS Z 2247 thermal expansion–based phase transition analysis |
| Brand | Aikonchem |
|---|---|
| Model | CentriVet |
| Type | Handheld Electrochemical Blood β-Hydroxybutyrate (BHB) Analyzer |
| Sample | Fresh Whole Bovine Blood |
| Sample Volume | 1.2 µL |
| Assay Time | 9 s |
| Measurement Range | 0.0–8.0 mmol/L |
| Unit | mmol/L |
| Auto Power-Off | Activated after 2 min of inactivity |
| Operating Temperature | 5–45 °C |
| Operating Relative Humidity | 10–90% RH (non-condensing) |
| Data Storage Capacity | 450 test records with timestamp |
| Power Supply | Two CR2032 3.0 V lithium coin cells |
| Battery Life | ≥3,000 tests (excluding data transmission) |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Futura |
| Pricing | Upon Request |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SUPR-CM |
| Price Range | USD 135,000 – 270,000 |
| Brand | Atik |
|---|---|
| Sensor Resolution | 1620 × 1220 pixels |
| Sensor Type | Monochrome back-illuminated CCD |
| Pixel Size | 9.0 µm × 9.0 µm |
| Full Well Capacity | ~100,000 e⁻ |
| Read Noise | <10 e⁻ (at 0.1 MHz) |
| Dark Current | <0.001 e⁻/pixel/sec @ −20 °C |
| Cooling | Thermoelectric (TE) to −20 °C below ambient |
| Interface | USB 2.0 |
| Shutter | Electronic rolling shutter |
| Compliance | CE, RoHS, FCC Class B |
| Software Support | ASCOM, DirectShow, LabVIEW, MATLAB, Python (via SDK) |
| Brand | Atik Instruments |
|---|---|
| Sensor Resolution | 1460 × 1932 pixels |
| Sensor Type | Monochrome Back-Illuminated CCD |
| Pixel Size | 6.45 µm × 6.45 µm |
| Full Well Capacity | ~100,000 e⁻ |
| Read Noise | < 10 e⁻ (at slow readout) |
| Dark Current | < 0.001 e⁻/pixel/sec @ −20 °C |
| Cooling | Thermoelectric (TEC), regulated to ΔT ≤ −45 °C below ambient |
| Interface | USB 2.0 with proprietary low-noise controller |
| Shutter | Electronic Rolling Shutter (global reset capable) |
| Compliance | CE, RoHS, FCC Class B |
| Brand | Benteng |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | BT-1181 |
| Pricing | Upon Request |
| pH Measurement Range | 0.00–14.00 |
| pH Accuracy | ±0.02 pH |
| Resolution | 0.01 pH |
| Repeatability | ≤1% |
| Stability | ±1% F.S. / 4 h |
| Response Time (T90) | <1 min at 25 °C |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Compensation Range | 0.1–60.0 °C |
| Sample Temperature Range | 5–60 °C |
| Operating Ambient Temperature | 5–40 °C |
| Relative Humidity | ≤85% |
| Brand | Easysensor |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DF-H-05 |
| Price | USD 165 (FOB) |
| Target Analytes | Fe, Cd, Co, Cu, Mn, Zn, Pb, Ni, P, As, Cr, Mo, Sb, Se, V, W |
| Binding Layer | ZrO₂–Chelex composite gel, thickness 0.40 mm, dimensions 150 × 20 mm |
| Filter Membrane | PVDF, 0.10 mm thick, 150 × 20 mm |
| Diffusive Gel | Agarose-based, nominal thickness 0.80 mm |
| Sampling Area | 3000 mm² (150 × 20 mm) |
| Packaging | Individually sealed in sterile, light-blocking aluminum foil pouches under moist conditions |
| Shelf Life | 12 months at room temperature, protected from light and desiccation |
| Brand | AWT |
|---|---|
| Origin | United Kingdom |
| Model | 1000 Series Fire Detector Test Chamber |
| Compliance | EN 54-7, EN 54-5, EN 14604, BS 5446-2, GB 4715-2024, GB 4716-2024 |
| Configuration Options | 1100 (smoke-only), 1300 (heat-only), 1400 (combined smoke/heat), 1700 (heat-only with active cooling), 1800 (combined smoke/heat with active cooling) |
| Form Factor | Benchtop |
| Application Domain | Factory QC, R&D Lab, Certification Testing |
| Brand | Harrick |
|---|---|
| Origin | USA |
| Model | HPL-C-13 |
| Construction Material | 316 Stainless Steel |
| Maximum Operating Pressure | 34.5 MPa (5000 psi) |
| Temperature Range | Up to 240 °C (with Kalrez O-rings) or 200 °C (with Viton O-rings) |
| Optical Path Length Range | 6 µm – 5 mm (via interchangeable PTFE spacers) |
| Window Aperture | 8 mm clear diameter |
| Port Configuration | Two 1/16″ Swagelok™ fittings |
| Thermal Management | Integrated cartridge heater, K-type thermocouple, and coolant channels |
| Mounting | FTIR-compatible slide-in sample stage |
| Compliance | Designed for ASTM E1421-compliant IR transmission measurements under process-relevant conditions |
| Brand | SGM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ICP |
| Price | USD 195 (FOB Beijing) |
| Operating Temperature | Up to 10,000 K |
| Material | High-Purity Quartz (≥99.99% SiO₂) |
| Inner Diameter | 2.0 mm |
| Middle Tube ID | 12.0 mm |
| Outer Tube ID | 22.0 mm |
| Wall Thickness | 1.0–1.2 mm |
| Thermal Shock Resistance | ≥5 thermal cycles from 25 °C to 800 °C without cracking |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 2DMax1100A1 / 2DMax1100P1 |
| Flow Rate Range | 0–200 mL/min (customizable higher flow available) |
| Maximum Pressure | 0–4000 psi with overpressure protection |
| UV-Vis Detection Wavelength Range | 190–850 nm (quad-wavelength simultaneous detection), wavelength accuracy: ±0.2 nm |
| Light Source | Deuterium lamp + Tungsten lamp |
| Autosampler Capacity | 144 vials (sealed vial design with needle wash function) |
| Fraction Collector (2DMax1100P1 only) | 160 positions, 15 mm tube diameter |
| Software Platform | Windows 7/10 (64-bit) |
| Communication Interface | Ethernet |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 2DMax1100A2 / 2DMax1100P2 |
| Flow Range | 0–200 mL/min (customizable up to higher rates) |
| Maximum Pressure | 4000 psi with overpressure protection |
| UV-VIS Wavelength Range | 190–850 nm (quad-wavelength simultaneous detection), wavelength accuracy: ±0.2 nm |
| Light Source | Deuterium lamp + Tungsten lamp |
| Autosampler Capacity | 144 vials (sealed vial design with needle wash function) |
| Fraction Collector (2DMax1100P2 only) | 160 positions, 15 mm tube diameter |
| Software Platform | Windows 7/10 (64-bit) |
| Communication Interface | Ethernet |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 2DMax1100A3 / 2DMax1100P3 |
| Price | Upon Request |
| Pump Flow Range | 0–200 mL/min (customizable higher flow available) |
| Maximum Pressure | 4000 psi with overpressure protection |
| UV-Vis Detector Wavelength Range | 190–850 nm (quad-wavelength simultaneous detection), wavelength accuracy: ±0.2 nm |
| Light Source | Deuterium lamp + Tungsten lamp |
| Autosampler Capacity | 144 vials (sealed vial design with needle wash function) |
| Fraction Collector (2DMax1100P3 only) | 160-tube rack, 15 mm tube diameter |
| Software Platform | Windows 7/10 (64-bit) |
| Communication Interface | Ethernet |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | 2DMax1500A1 / 2DMax1500P1 |
| TLC Plate Max Size | 200 × 200 mm |
| Laser Power | 5 mW |
| Sealing Force | Up to 500 N |
| Solvent Flow Rate (Extraction) | 0.05–0.3 mL/min |
| Extraction Probe Options | Ø4 mm, Ø5 mm circular |
| HPLC Flow Range | 0–100 mL/min (customizable) |
| Pressure Range | 0–10,000 psi (A1) / 0–4,000 psi (P1) |
| UV-VIS Detection | Four simultaneous wavelengths, 190–900 nm |
| Wavelength Accuracy | ±0.2 nm |
| Monochromator | 1200-line grating |
| Light Source | Deuterium–Tungsten dual lamp |
| Quantitation Loop | 20 µL (A1) / 2 mL (P1) |
| Autosampler | Integrated |
| Fraction Collector Capacity | 160 positions |
| Gradient Composition | 0–100% linear A:B |
| Software Platform | Windows 7/8/10 |
| Communication Interface | Ethernet |
| Power Supply | 110–220 V AC, 500 W |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | 2DMax1500A2 / 2DMax1500P2 |
| TLC Plate Max Size | 200 × 200 mm |
| Laser Power | 5 mW |
| Seal Force | up to 500 N |
| Solvent Flow Rate (Extraction) | 0.05–0.5 mL/min |
| Extraction Probe Options | Ø4 mm, Ø5 mm circular |
| HPLC Flow Range | 0–100 mL/min (customizable) |
| Pressure Range | 0–10,000 psi |
| UV-VIS Detection Wavelength Range | 190–900 nm (quad-wavelength simultaneous detection) |
| Wavelength Accuracy | ±0.2 nm |
| Monochromator | 1200 lines/mm grating |
| Light Source | Deuterium–Tungsten dual lamp |
| Quantitative Loop | 20 µL (customizable) |
| Autosampler | Integrated |
| Fraction Collector Capacity | 160 positions |
| Gradient Composition Range | 0–100% linear A:B |
| Software Platform | Windows 7/8/10 |
| Communication Interface | Ethernet |
| Power Supply | 110–220 V AC, 500 W |
| Gas Supply | Nitrogen or compressed air |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Model | 916 Ti-Touch |
| Electrode Interfaces | 2 working electrode ports |
| Dosing Channels | 2 independent dosing units |
| Connectivity | Built-in Ethernet & LIMS interface (no PC required) |
| Report Output | Auto-generated PDF reports saved to USB drive |
| Sample Handling | Optional automated sample processor with interchangeable rotor trays (e.g., 12-, 24-, or 48-position) |
| Stirring Control | Adaptive speed adjustment based on sample viscosity |
| Dosing Technology | Dosino TMDosino™ multi-dose module — reagent cartridge replacement without disassembly or operator contact |
| Regulatory Compliance | Full GLP/GMP traceability |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | AutoChem II 2920 |
| Temperature Range | –110 °C to 1100 °C |
| Detection Method | High-Stability TCD (Thermal Conductivity Detector) |
| Gas Inlets | 12 |
| Automated Valves | 4 × 6-port valves |
| Mass Flow Controllers | 4 (sample prep, dual carrier/reference, analysis) |
| Sample Tube | FlowThru™ quartz, rated to 1100 °C |
| TCD Zone Temperature | 150–250 °C |
| Optional Accessories | Online MS/FTIR/GC interface, vapor generator, cryogenic bath (–110 °C) |
| Software | Windows-based AutoChem software with GRAMS/32 peak processing module |
| Analytical Modes | TPD, TPR, TPO, TPRx, pulse chemisorption, isothermal reaction, BET surface area |
| Brand | Microphotons |
|---|---|
| Origin | Imported |
| Manufacturer Type | OEM Manufacturer |
| Model | C3A-2700LAE |
| Pricing | Upon Request |
| Brand | NCS (China Iron and Steel Research Institute Group) |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Model | Pure Iron Flux |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | PerkinElmer DSC 8500 coupled with EXFO® UV Curing System |
| Pricing | Available upon request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RQflex 20 |
| Price | Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PPSQ-51A / PPSQ-53A |
| Pricing | Available Upon Request |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | TESC-5133 |
| Temperature Control Range | −42 °C to 90 °C |
| Compliance | ASTM D5133, ASTM D7110, SH/T 0732, GB/T 11121 |
| Cooling Method | Solid-State Peltier |
| Sample Chamber | Sealed, Thermally Isolated Enclosure |
| Automation Level | Fully Automated, Unattended Operation |
| Footprint | Compact Benchtop Design |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ACOD-30 |
| Pricing | Available Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | APIA-100 |
| Pricing | Available Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | L9 |
| Pricing | Available Upon Request |
