Other Industrial Process Control & Online Analyzers
Filter
Showing 61–90 of 270 results
| Brand | AMETEK |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3050-AM |
| Pricing | Available Upon Request |
| Brand | AMETEK |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3050-DO |
| Pricing | Available Upon Request |
| Brand | AMETEK |
|---|---|
| Origin | USA |
| Model | 3050-OLV |
| Measurement Principle | Quartz Crystal Oscillation (QCM) |
| Output Units | ppmv H₂O, °C露点 (Dew Point Temperature at Specified Pressure) |
| Compliance | Suitable for Class I, Div 1 Hazardous Areas (with optional enclosure) |
| Certifications | ATEX, IECEx (optional), UL/cUL Listed |
| Typical Pressure Range | 0.1–10 MPa (user-configurable compensation) |
| Response Time (t₉₀) | < 60 s |
| Detection Limit | < 1 ppmv H₂O in gas streams |
| Brand | AMETEK |
|---|---|
| Origin | Canada |
| Model | IPS-4 |
| Measurement Principle | Dual-Wavelength Ultraviolet and Infrared Absorption Spectroscopy |
| Compliance | Designed for hazardous area installation (Class I, Div 1/Zone 1 optional), CE, RoHS, ATEX/IECEx certification available per configuration |
| Sample Interface | In-situ probe or extractive gas cell (standard 1–5 m pathlength) |
| Output | 4–20 mA analog + Modbus RTU/TCP digital interface |
| Environmental Rating | IP66/NEMA 4X enclosure |
| Brand | AMETEK |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 5900 |
| Pricing | Available Upon Request |
| Brand | AMETEK |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 888 |
| Pricing | Available Upon Request |
| Brand | AMS |
|---|---|
| Origin | Germany |
| Model | RHADOX 7100 |
| Explosion Protection | ATEX II 2G Ex pxb IIB+H2 T4 Gb X (Zone 1) / ATEX II 3G IIB+H2 T3 Gc (Zone 2) |
| Response Time (T90) | 10–30 s |
| Repeatability | ≤1.0% of measured value |
| Long-term Drift | ≤2% of full scale per month |
| Temperature Drift | <0.02% / K (relative to span end) |
| Air Demand Range | 1.5–30 m³ air/m³ gas |
| Wobbe Index Range | 5–120 MJ/m³ |
| Analog Output | 2 × 4–20 mA (galvanically isolated) |
| Display | 2×16-character backlit LCD + optional full-color status display |
| Operating Temperature | –5°C to +45°C (electronics), +5°C to +60°C (gas path) |
| Gas Inlet/Outlet | 6/12 mm stainless steel tubing or flanged connections |
| Sample Flow Rate | 20–100 Nl/h (process gas), 50–500 Nl/h (instrument air) |
| Gas Pressure | ≥0.1 bar(g), max 17 bar(g) |
| Instrument Air | ≥2 bar(g), max 8 bar(g) |
| Power Supply | 115/230 V AC, 50–60 Hz, 500 VA |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 1000×900×350 mm |
| Weight | ~100–125 kg (configurable) |
| Brand | AMS |
|---|---|
| Origin | Germany |
| Model | RHADOX 7100/7100EX/7300/7300EX |
| Repeatability | CARI & Wi ≤ 1.0% of reading |
| Drift | ≤ 2% of reading/month |
| Response Time (T90) | 10–30 s (gas viscosity-dependent) |
| Explosion Protection | ATEX II 2G Ex pxb IIB+H2 T4 Gb X (Zone 1) |
| Operating Temperature | +5 °C to +60 °C |
| Sample Flow Rate | 20–100 NL/h (gas), 50–500 NL/h (instrument air) |
| Gas Inlet Pressure | ≥ 0.1 bar(g) (7100 series), ≥ 0.5 bar(g) (7300 series), max 17 bar(g) |
| Instrument Air Pressure | ≥ 2 bar(g), max 8 bar(g) |
| Analog Outputs | 2 × 4–20 mA (7100), 4 × 4–20 mA (7300), galvanically isolated |
| Digital Interface | RS232 (standard), optional RS485 or Ethernet |
| Measurement Parameters | Wobbe Index (Wi), Combustion Air Requirement Index (CARI), Specific Gravity (SG), Lower Calorific Value (LCV) |
| Brand | Antek by PAC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | NSure |
| Price Range | USD 70,000 – 140,000 (FOB) |
| Detection Principle | Ultraviolet Fluorescence (UVF) |
| Compliance | ASTM D5453, D6667, SH/T 0689, ISO 20846, GB/T 11060.8 |
| Measurement Range | 0–8000 ppm total sulfur |
| Repeatability | ≤1% RSD |
| Cycle Time | 1–5 min (typ. 3 min) |
| Accuracy | ≤1% FS |
| Output | 4–20 mA analog + fault alarm |
| Enclosure Rating | NEC Class 1 Div 2 Groups A, B, C, D / ATEX Zone 1 Ex db ib px b IIC T4 Gb |
| Sample Phase | Liquid or gas |
| Max Inlet Pressure | 400 psig |
| Max Inlet Temp | 100 °C |
| Sample Filtration | ≥0.5 µm |
| Carrier Gas | Instrument air (99.975%, 50 psig, 5–15 cc/min) |
| Combustion Air | Instrument air (99.975%, 50 psig, 350–500 cc/min) |
| Power | 230 VAC, 6.5 A, 50–60 Hz, 1500 W |
| Operating Ambient | 0–40 °C |
| Display | 7″ Siemens industrial touchscreen HMI |
| Cooling | Integrated Peltier-cooled UVF detector |
| Dryer | Membrane-type water removal module |
| Flow Control | Electronically regulated mass flow controllers |
| Architecture | Modular single- or dual-stream configuration |
| DCS Interface | 3/4″ NPT(F) with explosion-proof junction box and sealed conduit entries |
| Communication Protocol | RS-458 Modbus RTU (standard) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Imported Industrial Process Analyzer |
| Model | Cobrix 5501/5601 & Cobrix 7501/7601 |
| Measurement Parameters | °Brix (0–50), %Diet (0–150), CO₂ (0–6 vol. / 0–12 g/L), Alcohol (0–16% w/w or 0–20% v/v), Total Acidity (TA), Conductivity, Colorimetry, Dissolved Oxygen |
| Accuracy | ±0.02 °Brix (sugared), ±0.5% Diet (sugar-free) |
| Temperature Range | 0–30 °C (5501/5601), 0–25 °C (7501/7601) |
| IP Rating | IP65+ |
| Max. Sensor-to-Unit Distance | 250 m |
| Communication | Ethernet (Davis 5 software), 4–20 mA analog outputs, digital I/O, fieldbus interfaces (PROFIBUS, Modbus TCP, EtherNet/IP) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | L-Dens |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | L-Sonic 5100 / L-Sonic 6100 |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Wine Monitor |
| Pricing | Available Upon Request |
| Brand | API |
|---|---|
| Origin | USA |
| Model | SPN300 |
| Sensor Type | Capacitive/Inductive |
| Resolution | 0.1 µm |
| Dynamic Response | 25 kHz |
| Measurement Range | 0.1–0.8 mm |
| Linearity | < 0.1% FS |
| Thermal Stability | < 0.1% / °C |
| Sensor Dimensions | 30.5 mm (Ø) × 53.3 mm (L) |
| Brand | APURE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | RW-60 |
| Output Signal | 4–20 mA analog + RS485 Modbus RTU digital |
| Display | Backlit LCD with bilingual (English/Chinese) UI |
| Power Supply | 24 VDC ±15% |
| Environmental Rating | IP66 |
| Operating Temperature | –10 to 60 °C |
| Temperature Compensation | Automatic, high-precision thermistor-based |
| Relay Outputs | 2 configurable SPDT relays (max. 5 A @ 250 VAC) |
| Measurement Principle | Time-of-Flight (ToF) ultrasonic echo detection |
| Typical Range | 0.3 to 6.0 m (adjustable via software) |
| Repeatability | ±1 mm |
| Response Time | < 2 s (configurable) |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | CGA |
| Price | USD 28,000 (approx.) |
| Linearity Error | <0.1% FS |
| Repeatability | <0.1% FS |
| Span Drift | ≤1% per 30 days |
| Response Time (T90) | 5 seconds |
| Explosion Protection | Not certified (non-hazardous area use only) |
| Sensor Technologies | FID, NDIR, Paramagnetic, Electrochemical (eCell), Alumina-based Hygrometer (Al₂O₃), EPD (Electrostatic Precipitation Detector) |
| Temperature Compensation | Integrated |
| Pressure Compensation | Integrated |
| Calibration Options | Multi-point auto-calibration available per module |
| Module Architecture | Up to 3 internal sensor modules + 1 external Al₂O₃ module |
| Data Logging | Onboard with real-time trend visualization |
| Brand | ASD |
|---|---|
| Origin | USA |
| Model | QualitySpec 7000 |
| Wavelength Range | 350–2500 nm |
| Wavelength Accuracy | ±1 nm |
| Spot Size | 76–100 mm |
| Output Interface | Fast Ethernet (100BASE-T or 100BASE-FX) |
| OPC Server Integration | Yes |
| Max. Components Quantified | 20 per measurement |
| Light Source | 100 W Quartz Halogen |
| Optical Head to Conveyor Distance | 74 cm |
| Power Consumption | 230 W (±10%, 12 A, 50/60 Hz) |
| Operating Temperature | −20 to +50 °C |
| Relative Humidity | 5–95% non-condensing |
| Certifications | CE |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-800α (Chlor-Alkali Industrial Application) |
| Measurement Principle | Refractive Index (Brix, ATC) |
| Accuracy | ±0.1% Brix, ±1°C/°F |
| Range | 0.00–80.00% Brix (ATC), -15–160.0°C |
| Temperature Compensation | 5–100°C |
| Output | 4–20 mA, RS-232C |
| IP Rating | IP67 |
| Light Source | LED (≈589 nm, sodium D-line equivalent) |
| Prism Material | Synthetic Sapphire |
| Cell Body Material | SUS316L Stainless Steel |
| Dimensions | 160 × 167 × 110 mm |
| Weight | 2.4 kg |
| Response Interval | ~1 sec (configurable up to 5 intervals) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-BX/SALT α |
| Measurement Range | Brix 0.0–93.0%, Salt 0.00–15.00% |
| Resolution | Brix 0.1%, Salt 0.01% |
| Accuracy | Brix ±0.5% |
| Temperature Control Range | 4–95 °C |
| Wetted Materials | SUS 316L stainless steel + synthetic sapphire prism |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 630 (FOB) |
| Measurement Range | 0–100 kg/cm² (0.1 kg/cm² resolution) |
| Pressure Transducer Type | High-precision hydraulic load cell |
| Display | LED, with dual-unit output (kg, N, lbf) |
| Hydraulic Oil Displacement Rate | 170 ± 15 mL/min |
| Dimensions (W×D×H) | 450 × 430 × 520 mm |
| Accuracy | ±1 kPa |
| Calibration Interface | Built-in traceable calibration routine compliant with ISO 7267-1 and ASTM D774 |
| Brand | Bacharach |
|---|---|
| Origin | USA |
| Model | 7100 |
| Measurement Range | 0–100 ppm / 0–1000 ppm |
| Sensor Type | Miniature Zirconia (ZR-400) |
| Accuracy | ±2.0% of reading or ±3 ppm (whichever is greater) |
| Response Time (T90) | <10 s at 500 mL/min |
| Display | 0.75" LED numeric |
| Enclosure Rating | Front panel NEMA 4 (IP66), Electronics chassis NEMA 1 (IP20) |
| Operating Temperature | 5–40°C |
| Humidity | 0–95% RH non-condensing |
| Power Input | 90–264 VAC or 24 VDC |
| Analog Outputs | 0–1 VDC, 0–5 VDC, 0–10 VDC, 4–20 mA |
| Digital Interface | RS-232 service port |
| Relay Outputs | 2 field-adjustable alarm relays + 1 fixed system fault relay |
| Sample Connection | 1/8" NPT female |
| Weight | <2.2 kg |
| Brand | Bacharach |
|---|---|
| Origin | USA |
| Model | 7100P |
| Measurement Range | 0–100 ppm / 0–1000 ppm (auto-ranging) |
| Sensor Type | Miniature Zirconia (ZR-400) |
| Accuracy | ±3 ppm or ±2.0% of reading (whichever is greater) |
| Response Time | <15 s T90 at 500 mL/min |
| Sample Interface | 1/8" NPT female |
| Enclosure Rating | Front Panel — NEMA 4 (IP66), Electronics Chassis — NEMA 1 (IP20) |
| Display | 0.75" LED, dual-color (green = normal/online, yellow = fault) |
| Alarms | Two user-configurable relay alarms + one fixed system-fault relay |
| Analog Outputs | 0–1 VDC, 0–5 VDC, 0–10 VDC, and 4–20 mA |
| Digital Interface | RS-232 service port |
| Power Supply | 90–264 VAC or 24 VDC |
| Operating Temperature | 5–40 °C (41–104 °F) |
| Relative Humidity | 0–95% RH (non-condensing) |
| Weight | <2.2 kg |
| Brand | BAIF-MAIHAK |
|---|---|
| Model | BM08 Ex |
| Measurement Principle | Infrared Photoacoustic Spectroscopy (PAS) with Optional Electrochemical, Thermal Conductivity & Trace Moisture Modules |
| Maximum Module Capacity | 3 (e.g., dual PAS + 1 TCD or electrochemical O₂) |
| Response Time per Component | 0.5–20 s (dependent on number of components and measurement ranges) |
| Enclosure Rating | Explosion-Proof (Ex d IIB T4 Gb / Ex ib IIB T4 Gb configurable per module) |
| Display | 7-inch capacitive touchscreen HMI |
| Analog Outputs | 4 × 0–20 mA (configurable per channel) |
| Digital Interfaces | RS232, MODBUS-RTU |
| Relay Outputs | 5–8 programmable (zero calibration, span calibration, fault, alarm, etc.) |
| Mid-Range Scaling | Supported (non-zero start span definition) |
| Zero Gas Options | Dual independent zero gas references (including negative offset for cross-sensitivity compensation) |
| Span Calibration Gases | Up to 4 user-defined calibration gas values with component-specific assignment |
| Data Hold Function | Active during calibration or maintenance operations |
| Compliance | Designed to meet GB 3836.1–2010 / GB 3836.2–2010 (China Ex), CE marking applicable per module configuration |
| Origin | Beijing, China |
| Distributor Type | Authorized distributor (non-manufacturer) |
| Brand | BAIF-MAIHAK |
|---|---|
| Model | QGS-08C EX |
| Type | Non-Dispersive Infrared (NDIR) Gas Analyzer |
| Detection Principle | Selective Infrared Absorption |
| Light Source | High-Power Stable IR Source |
| Detector | Thin-Film Microphone Detector (Capacitive) |
| Optical Path | Single-Source, Series Dual-Absorption Chamber |
| Display | Backlit LCD with Full Chinese Menu Interface |
| Signal Processing | Fully Digital Signal Processing (DSP) |
| Output | Isolated 4–20 mA (also supports 0/2–20 mA), Load ≤ 400 Ω |
| Communication | RS-232, Modbus-RTU |
| Safety Certification | Ex d IIB T6 Gb (for QGS-08C EX variant) |
| Environmental Protection Compliance | Meets China’s HJ 75–2017 & HJ 76–2017 for CEMS applications |
| Enclosure Rating | IP65 (industrial dust/water resistance) |
| Power Supply | AC 220 V ± 10 %, 50 Hz |
| Warm-up Time | ≤ 30 min to operational stability |
| Operating Temperature | –10 °C to +50 °C |
| Storage Temperature | –20 °C to +60 °C |
| Brand | BAIF-MAIHAK |
|---|---|
| Model | QGS-08CN |
| Origin | Beijing, China |
| Detection Principle | Infrared Photoacoustic Spectroscopy (PAS) |
| Configurable Modules | Up to 3 (e.g., Photoacoustic IR, Paramagnetic O₂, Electrochemical, Thermal Conductivity) |
| Max Simultaneous Gases | 3 |
| Measurement Interval | 0.5–20 s (gas-dependent) |
| Display | 7-inch TFT capacitive touchscreen |
| Analog Outputs | 4 × 0–20 mA (configurable per channel) |
| Digital Interfaces | RS232, MODBUS-RTU |
| Relay Outputs | 8 programmable (zero cal, span cal, fault, alarm, etc.) |
| Zero Gas Options | 2 independent zero references (including negative offset for cross-sensitivity compensation) |
| Span Calibration Gases | Up to 4 user-defined calibration standards |
| Intermediate Range Functionality | Supported (non-zero-start measurement ranges) |
| Data Hold | Active during calibration or maintenance |
| Cross-Sensitivity Compensation | Built-in lateral sensitivity correction algorithm |
| Compliance Status | Listed in Zhongguancun National Innovation Demonstration Zone’s 2016 Government Procurement Catalog for New Technologies and Products |
| Brand | BAIF-MAIHAK |
|---|---|
| Model | QRD-1102C |
| Detection Principle | Thermal Conductivity Differential Measurement |
| Target Gases | H₂, Ar, and other binary/multicomponent gas mixtures |
| Output Signals | Isolated 4–20 mA (≤400 Ω load), relay status outputs (calibration, fault, alarm, range switching) |
| Communication | RS-232, Modbus-RTU |
| Display | Backlit LCD with Chinese menu interface |
| Construction | All-metal gas path, corrosion-resistant sensor elements |
| Environmental Rating | Industrial-grade housing, pressure-rated flow path |
| Certifications | Compliant with GB/T 13283–2008 (Industrial Process Analyzers), designed for GLP-aligned operation in continuous monitoring environments |
| Power | AC 220 V ±10%, 50 Hz |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Brand | Baoying |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Baoying Technology Co., Ltd. |
| Model | GW-03 |
| Measured Gases | O₂ (0–10% / 25% auto-range), CO (0–2.5%), NO (0–2500 ppm), NOₓ, SO₂ |
| Max. Operating Temperature | 1400 °C |
| Dust Tolerance | Unrestricted (cement kiln applications) |
| Ambient Temp. Range | −20 °C to 45 °C |
| Relative Humidity | <90% RH |
| Filter Material | Titanium alloy sintered metal |
| Filtration Precision | ≤0.1 µm |
| Output Alarm | Dry contact, 1 A/220 V AC, interlock-capable |
| Cooling Method | Oil-cooled dry extraction (thermic oil medium) |
| Certified Components | ABB EL3020 or Siemens Ultramat 23 IR analyzers |
| Probe Integrity | SGS-certified materials & welds |
| Optional Features | Motorized telescopic cleaning rod, Kstar 10 kVA UPS backup |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BASELINE 9100 |
| Pricing | Available Upon Request |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | MGA-3000 |
| Sensor Type | Paramagnetic |
| O₂ Range | 0–100% vol |
| O₂ Resolution | 0.01% vol |
| O₂ Accuracy | ±1% FS |
| CO Range | 0–10 ppm |
| CO Resolution | 0.01 ppm |
| CO Accuracy | ±2% FS |
| CO₂ Range | 0–500 ppm |
| CO₂ Resolution | 0.1 ppm |
| CO₂ Accuracy | ±2% FS |
| Dew Point Temperature Range | −50 to +100 °C |
| Dew Point Resolution | 0.1 °C |
| Dew Point Accuracy | ±0.5 °C |
| Barometric Pressure Range | 50–110 kPa |
| Pressure Resolution | 0.01 kPa |
| Pressure Accuracy | ±0.5 kPa |
| Zero Drift | ≤2% FS |
| Span Drift | ≤±2% FS |
| Data Storage | Scheduled auto-storage |
| Analog Output | 4–20 mA |
| Digital Interfaces | RS232 / RS485 / USB / Ethernet |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | MGA-6000 |
| Sensor Type | Paramagnetic |
| Measurement Range | 80/98–99.99% O₂ (user-selectable span) |
| Accuracy | ±0.1% FS |
| Repeatability | ±0.01% FS |
| Resolution | 0.01% O₂ |
| Response Time | T₉₀ ≤ 15 s |
| Sample Flow Rate | 400 ± 50 mL/min |
| Operating Temperature | –15 °C to +45 °C |
| Relative Humidity | ≤ 90% RH (non-condensing) |
| Data Storage | Scheduled automatic logging |
| Output Interfaces | 4–20 mA analog, RS232 / RS485 serial, USB, Ethernet (TCP/IP) |