| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3100 |
| Sensor Type | Tunable Diode Laser (TDLAS) |
| Measurement Ranges | H₂S: 0–100 ppm / 0–5000 ppm |
| O₂ | 0–5 %vol (customizable up to 100 %vol) |
| CO | 0–100 %vol |
| CO₂ | 0–100 %vol |
| CH₄ | 0–20 %vol |
| Accuracy | ≤ ±1 % FS |
| Repeatability | ≤ ±1 % FS |
| Resolution | 0.01 %vol |
| Response Time (T90) | ≤ 1 s |
| Explosion Protection | Exd II CT6 Gb / Ex tb IIIC T80°C Db |
| Power Supply | 24 V DC, 24 W |
| Ambient Temperature | −20 to +60 °C |
| Purge Gas | Industrial nitrogen, 0.3–0.8 MPa |
| Communication | RS485, RS232 |
| Analog Outputs | 2 × 4–20 mA |
| Digital Outputs | 3 × relay |
| Installation | In-situ (transmission path) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3100 |
| Sensor Type | Tunable Diode Laser (TDLAS) |
| Measurement Ranges | H₂S: 0–100 ppm / 0–5000 ppm |
| O₂ | 0–5 %vol (customizable up to 100 %vol) |
| CO | 0–100 %vol |
| CO₂ | 0–100 %vol |
| CH₄ | 0–20 %vol |
| Accuracy | ≤ ±1 %FS |
| Repeatability | ≤ ±1 %FS |
| Resolution | 0.01 %vol |
| Response Time (T90) | ≤ 1 s |
| Explosion Protection | Exd II CT6 Gb / Ex tb IIIC T80°C Db |
| Power Supply | 24 V DC, 24 W |
| Ambient Temperature | −20 to +60 °C |
| Purge Gas | Industrial N₂, 0.3–0.8 MPa |
| Output Signals | 2 × 4–20 mA, 3 × relay |
| Communication | RS485, RS232 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3100 |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Sampling Method | In-situ |
| Linearity Error | ≤±1% F.S. |
| Repeatability | ≤±1% |
| Span Drift | ≤±1% F.S. |
| Response Time | T90 ≤ 1 s |
| Explosion Protection Rating | Ex db IIC T6 Gb / Ex tb IIIC T80°C Db |
| Measured Gases | H₂S (0–100 ppm / 0–5000 ppm), O₂ (0–5 %vol, customizable to 100 %vol), CO (0–100 %vol), CO₂ (0–100 %vol), CH₄ (0–20 %vol) |
| Resolution | 0.01 %vol |
| Power Supply | 24 V DC, 24 W |
| Ambient Temperature Range | −20 to +60 °C |
| Purge Gas | Industrial nitrogen, 0.3–0.8 MPa |
| Output Signals | 2 × 4–20 mA, 3 × relay outputs |
| Communication Interface | RS485, RS232 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3100-O2 |
| Sensor Type | Tunable Diode Laser (TDLAS) |
| Measurement Range | O₂: 0–5% vol (customizable up to 100% vol) |
| Accuracy | ≤±1% F.S. |
| Repeatability | ≤±1% F.S. |
| Resolution | 0.01% vol |
| Response Time (T90) | ≤4 s |
| Environmental Operating Temperature | −20 to +60 °C |
| Power Supply | 24 V DC, 24 W |
| Explosion Protection | Exd II CT6 |
| Output Signals | 2 × 4–20 mA, 3 × relay outputs |
| Communication Interface | RS485, RS232 |
| Purge Gas Requirement | Industrial nitrogen, 0.3–0.8 MPa |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GasTDL-3110 |
| Pricing | Upon Request |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3110 |
| Linearity Error | ≤±1% F.S. |
| Repeatability | ≤±1% |
| Span Drift | ≤±1% F.S. |
| Explosion Protection Rating | Ex db IIC T6 Gb / Ex tb IIIC T80℃ Db |
| Measurement Principle | TDLAS (Transmittance Configuration) |
| Measured Gases | H₂S (0–100 ppm / 0–5000 ppm), O₂ (0–5% vol, optional up to 100%), CO (0–100% vol), CO₂ (0–100% vol), CH₄ (0–20% vol) |
| Resolution | 0.01% vol |
| Ambient Temperature Range | −20 to +60 °C |
| Power Supply | 220 V AC, 50 Hz |
| Sample Gas Pressure | 0.3–0.8 MPa |
| Output Signals | 2 × 4–20 mA, 3 × Relay |
| Communication | RS485, RS232 |
| Sample Conditioning | Multi-stage filtration, automatic probe purge, condensate drainage |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LMS-1000 |
| Pricing | Upon Request |
| Measurement Principle | TDLAS |
| Measurand | H₂O vapor |
| Range | 0–50 ppm to 0–6000 ppm (customizable) |
| Accuracy | ±2% FS |
| Resolution | 0.1 ppm |
| Repeatability | ≤1.5% FS |
| Explosion Protection | Ex db IIC T6 Gb / Ex tb IIIC T80°C Db |
| Ingress Protection | IP66 |
| Ambient Temperature | −10°C to +50°C |
| Relative Humidity | 0–98% RH (non-condensing) |
| Sample Pressure | Inlet: 140–310 kPa |
| Measurement Cell | 800–1200 mbar(a) |
| Power Supply | 24 VDC ±20% or 100–240 VAC ±10%, 50/60 Hz, 10 W |
| Output Interfaces | 4–20 mA, RS-485, Modbus RTU/TCP, Ethernet |
| Display Options | Volume ratio (ppm(v)) and dew point temperature (°C/°F) |
| Dimensions (L×W×H) | 400 × 400 × 250 mm |
| Weight | 36 kg |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Not Applicable |
| Price | Upon Request |
| Linearity Error | ±2% F.S. |
| Repeatability | ±2% F.S. |
| Response Time (T90) | <10 s |
| Measurement Ranges | CO₂: 0–5,000 ppm |
| CO | 0–30% vol |
| CH₄ | 0–10% vol |
| Resolution | CO₂: 0.1 ppm |
| CO | 0.01% vol |
| CH₄ | 0.01% vol |
| Accuracy | ±2% F.S. for all gases |
| Stability | ≤±2% per month |
| Response Time (T90) | ≤30 s |
| Key | Brand: CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Explosion Protection Rating | Ex db IIC T6 Gb / Ex tb IIIC T80°C Db |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Measured Gases | O₂, CO, CO₂, H₂S, CH₄ |
| Response Time | <40 s (at 2 L/min) |
| Sample Flow Rate | 0.7–1.2 L/min (optimal), up to 2 L/min |
| Output Interfaces | RS-485, RS-232, 4–20 mA |
| Power Supply | AC 220 V, 50 Hz |
| Display | Integrated LCD |
| Built-in Zeroing | Air auto-zero pump |
| Diagnostic Capability | Real-time sensor self-diagnosis |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | AKTA pilot 600S / AKTA pilot 600R |
| Application Scope | GMP and non-GMP process development, scale-up studies, and small-batch cGMP manufacturing |
| Column ID Range | 26–200 mm |
| Pump Flow Rate Range | 0.01–600 mL/min |
| Maximum System Pressure | 20 MPa (200 bar) |
| Gradient Accuracy | ≤ ±0.5% RSD |
| Software Platform | UNICORN 7.x or later |
| Compliance | Designed to support 21 CFR Part 11, GAMP 5, and GLP/GMP documentation requirements |
| Modular Architecture | Yes |
| Prepacked Column Compatibility | ReadyToProcess™ 1 L and 2.5 L columns |
| AxiChrom™ Integration | Native via SmartPacking port |
| Footprint | Compact benchtop or ReadyKart-mountable design |
| Weight | < 90 kg |
| Brand | Drexelbrook |
|---|---|
| Origin | Shanghai, China |
| Model | DR5400 Series |
| Measurement Principle | FMCW (Frequency-Modulated Continuous Wave) Radar |
| Output Signal | 2-wire 4–20 mA with HART® Protocol |
| Max. Measuring Range | 30 m |
| Accuracy | ±5 mm (standard), ±10 mm (extended range) |
| Beam Angle | as low as 6° |
| Antenna Options | 316L Stainless Steel Horn or PP/PTFE Rod Antenna (extendable) |
| Process Temperature | –40 °C to +250 °C |
| Process Pressure | –0.1 MPa to +4 MPa |
| Enclosure Rating | IP66/IP67 |
| Brand | Drexelbrook |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-sourced) |
| Model | Usonic Series |
| Product Type | Ultrasonic Level Transmitter |
| Measurement Principle | Pulse-Echo Ultrasonic Time-of-Flight |
| Maximum Range | 9.1 m |
| Beam Angle | 5° |
| Brand | LINGXI OPTOELECTRONICS |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | TGA-321 |
| Pricing | Upon Request |
| Brand | LINGXI OPTOELECTRONICS |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | TGA-323 |
| Pricing | Upon Request |
| Brand | LINGXI OPTOELECTRONICS |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TGA-327 |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CLA-8000 |
| Pricing | Available upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | GC-1010-AA/AE |
| Pricing | Upon Request |
| Channel Count | 10 |
| Mounting Type | Wall-Mounted |
| Sensor Interface | 2-wire & 3-wire toxic/combustible gas detectors |
| Display | LCD + High-Brightness LED Indicators |
| Communication Interfaces | RS485, Ethernet |
| Output | 1 × 24 V DC Active Output |
| Alarm Logic | Multi-sensor Intelligent Voting Algorithm |
| Signal Acquisition | Synchronized Real-Time Sampling |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GRD-2000 |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GRD-3000 |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM/ODM) |
| Country of Origin | China |
| Model | GRTU-100 |
| Pricing | Available upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | GRTU-200 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GT-1020-TF |
| Pricing | Upon Request |
| Certification | Ex d IIB T6 Gb |
| Hazardous Area Classification | Zone 1 & Zone 2 |
| Sensor Technology | Electrochemical (Imported) |
| Output Signal | 4–20 mA / RS485 |
| Alarm | Integrated Visual-Audible Alarm |
| Environmental Protection | IP66 |
| Compensation | Built-in Temperature & Concentration Compensation |
| Enclosure Material | Stainless Steel with Multi-Layer Corrosion Protection |
| Remote Operation | Infrared Bidirectional Handheld Remote (Display Enabled, No-Open-Box Configuration) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GT-1020/1030/1031-TF |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | GT-1030 |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | GT-1030/1031-TS |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GT-1040 |
| Pricing | Available Upon Request |
| Certification | Ex d II CT6 Gb |
| Operating Zones | Zone 1 & Zone 2 Hazardous Areas |
| Response Time (T90) | <10 s |
| Sensor Type | Imported High-Stability PID Sensor |
| Compensation | Integrated Temperature & Concentration Compensation |
| Enclosure | Corrosion-Resistant Multi-Layer Surface Treatment |
| Alarm Output | Integrated Visual-Audible Alarm Module |
| Communication | Infrared Bidirectional Remote Control with Display (No-Open-Cover Maintenance) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GT-1041 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | GT-1121 |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GT-2121 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GT-FL |
| Communication Interface | RS485 Modbus RTU |
| Maximum Node Capacity | 64 detectors per bus |
| Display | None (Bus-Only Variant) |
| Remote Configuration | Infrared bidirectional handheld remote (no cover removal required) |
| Sensor Compensation | Built-in temperature and concentration compensation algorithm |
| Status Indication | Dual-color (red/green) LED |
| Compliance | Designed for industrial hazardous area monitoring per GB 50493, compatible with SIL2-capable control systems |