Other Industrial Process Control & Online Analyzers
Filter
Showing 211–240 of 270 results
| Brand | Sinoptic |
|---|---|
| Model | iLAS |
| Type | In-Situ Cross-Beam Tunable Diode Laser Absorption Spectroscopy (TDLAS) Gas Analyzer |
| Origin | Hubei, China |
| Manufacturer | Sinoptic Instrument Co., Ltd. |
| Explosion Protection | Exd II CT6 |
| IP Rating | IP66 |
| Optical Path Length | ≤15 m |
| Sample Gas Temperature | ≤800 °C |
| Ambient Temperature | −30 to 55 °C |
| Humidity | ≤90% RH (non-condensing) |
| Power Supply | AC 220 V / DC 24 V |
| Analog Inputs | 2 × 4–20 mA |
| Analog Outputs | 2 × 4–20 mA (max. load 750 Ω) |
| Digital Interface | RS485, MODBUS RTU |
| Relay Outputs | 3 × (24 V, 1 A) |
| Purge Gas | N₂, 0.4–0.6 MPa |
| Measurable Gases | O₂, CO, CO₂, CH₄, NH₃, HCl, HF, H₂S, C₂H₆, HCN, H₂O (customizable) |
| Detection Limit | 0.01% vol |
| Full Scale Range | 0–99.99% vol |
| Operating Pressure | Atmospheric ±5 kPa |
| Brand | Sinoptic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | iLAS-200 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-425 |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Measurement Ranges | 0–1%, 0–5%, 0–10%, 0–25%, 0–100% O₂ (selectable) |
| Accuracy | < ±1% FS |
| Sensor Type | Miniaturized Electrochemical Fuel Cell |
| Operating Temperature | –10 to +50 °C |
| Temperature Compensation | Built-in |
| Enclosure Dimensions | 241 × 165 × 96 mm |
| Power Supply | 12–24 VDC, 25 mA |
| Output Signals | 4–20 mA, 0–10 VDC, MODBUS RS485 (ASCII, bi-directional) |
| Sample Flow Rate | 230–2500 mL/min |
| Certified | CE |
| Warranty | 12 months |
| Compatible Gases | N₂, Ar, He, H₂, hydrocarbon streams, and other inert or reducing atmospheres |
| Acid-Gas Option | Available with corrosion-resistant sensor for CO₂, H₂S, or SO₂-containing streams |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | NIRSpec |
| Pricing | Available Upon Request |
| Brand | Systech Illinois |
|---|---|
| Origin | United Kingdom |
| Model | 8102 |
| Measurement Principle | Coulometric Sensor (Electrochemical Oxygen Detection) |
| Standards Compliance | ASTM D3985, ASTM F1307, ASTM F1927, DIN 53380-3, ISO 15105-2, JIS K 7126 |
| OTR Range | 0.05–432,000 cc/(m²·day) |
| Resolution | 0.01 cc/(m²·day) |
| Repeatability | ±0.015 cc/(m²·day) or ±1% |
| Test Chamber Temperature Range | 10–40 °C (±0.1 °C) |
| Film RH Control | 0–100% RH (dry to saturated via humidified sponge) |
| Package RH Control | Ambient or chamber-controlled |
| Sensor Technology | Long-life e-Metric® coulometric cell |
| Anti-Surge™ Protection | Yes |
| Gas Requirement | Ambient air only (no N₂/H₂ mix required) |
| Brand | Systech Illinois |
|---|---|
| Origin | United Kingdom |
| Model | 8107 |
| Measurement Principle | Coulometric Sensor (ASTM F1307) |
| Test Range | 0.00025–2000 cm³/(pkg·day) |
| Resolution | 0.00001 cm³/(pkg·day) |
| Repeatability | ±0.00001 cm³/(pkg·day) or ±2% |
| Sensor Technology | Long-life E-metric Coulometric Cell |
| Protection | Anti-Surge™ Over-O₂ Compensation |
| Gas Requirement | Ambient air only (no N₂/H₂ mix required) |
| Brand | Systech Illinois |
|---|---|
| Origin | United Kingdom |
| Model | 8700 |
| Measurement Range (Pack) | 0.00004–2000 cm³/pack/day |
| Measurement Range (Film) | 0.04–100,000 cm³/m²/day |
| Test Temperature | Ambient (with optional temperature-controlled chamber) |
| Relative Humidity Control | Dry to 100% RH (saturated) |
| Calibration Standards | NIST-traceable reference films and certified gases |
| Dimensions | 760 × 590 × 350 mm |
| Weight | 65 kg |
| Brand | Systech |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Cylinder Oxygen Sampling & Analysis System |
| Pricing | Available Upon Request |
| Brand | Teledyne Cetac |
|---|---|
| Origin | USA |
| Model | 3110 |
| Measurement Range | 0–10 ppm to 0–25% O₂ |
| Output | 0–1 VDC analog |
| Sensor Type | Electrochemical fuel cell (B-2C for trace, B-1 for percent) |
| Response Time | <60 s (trace), <7 s (percent) |
| Operating Temperature | 0–40°C |
| Repeatability | ±1% of reading |
| Power | Rechargeable NiCd battery (>100 h per charge, 5-year service life) + AC adapter (110/220 VAC, 50/60 Hz) |
| Weight | 2.71 kg (6 lbs) |
| Certifications | FM/FMc Class I Div 1 Groups A–D T6, ATEX Ex ia IIC T3, CE marked |
| Ingress Protection | Not specified |
| Data Logging | Integrated |
| Safety Rating | Intrinsically safe |
| Brand | TH-analyzer |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TH-analyzer Co., Ltd. |
| Model | EZGAS2000H2 |
| Measuring Range (H₂) | 0–10%, 0–50%, 0–100% |
| Linearity Error | ±2% FS |
| Stability | ±2% FS / 7 days |
| Repeatability | ≤1% FS |
| Response Time (T90) | ≤30 s |
| Operating Ambient Temperature | 5–45 °C |
| Sample Gas Pressure | ≤20 kPa |
| Sample Flow Rate | 0.2–1.0 L/min |
| Power Supply | 12–24 VDC |
| Output Signal | 4–20 mA (isolated) |
| Communication Interface | RS485 (Modbus RTU protocol) |
| Dimensions | 50 × 74 × 75 mm (W × H × D) |
| Enclosure Rating | IP65 (module housing) |
| Brand | TH-analyzer |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Domestic Industrial Oxygen Analyzer |
| Model | EZGAS7000-O |
| Measuring Principle | Paramagnetic Pressure Detection |
| Typical Ranges | 0–5%, 0–10%, 0–21%, 0–100%, 90–100% O₂ (v/v) |
| Linearity Error | ±2% FS |
| Stability | ±2% FS over 7 days |
| Repeatability | ≤1% FS |
| Response Time (T₉₀) | ≤35 s |
| Operating Temperature | 5–45 °C |
| Sample Flow Rate | 0.5 L/min |
| Reference Gas Flow | ~10 mL/min |
| Power Supply | 220 V AC, 50 Hz |
| Analog Output | 4–20 mA (isolated) |
| Digital Interface | RS485 (Modbus RTU protocol) |
| Brand | TH-analyzer |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TH-analyzer |
| Model | THA-IEX-1 |
| Linearity Error | ±2% FS |
| Repeatability | 1% |
| Response Time (T90) | ≤25 s |
| Explosion Protection Rating | Ex d IIC T6 Gb |
| Operating Temperature | 5–45 °C |
| Stability | ±2% FS / 7 days |
| Ambient Temperature Effect | ±2% FS (5–45 °C) |
| Measurement Principle | NDIR (Non-Dispersive Infrared) Absorption |
| Detectable Gases | CO, CO₂, CH₄, SO₂, NO, NO₂, N₂O, SF₆, NH₃, O₂ (optional) |
| Brand | TH-analyzer |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Manufacture | Domestic (China) |
| Model | THA100R |
| Measurement Principle | Thermal Conductivity Detection |
| Measuring Range | H₂ 0–100% vol |
| Standard H₂ Ranges | 0–1%, 0–10%, 35–75%, 40–80%, 75–100%, 98–100% |
| Operating Ambient Temperature | 5–45 °C |
| Stability | ±2% FS / 7 days |
| Repeatability | ±1% FS |
| Linearity Deviation | ±2% FS |
| Response Time (T₉₀) | ≤30 s |
| Output | Isolated 4–20 mA current loop |
| Digital Outputs | 8 relay (switching) outputs |
| Display | Color LCD with touch interface |
| Enclosure | 483 mm (19″) rack-mount chassis |
| Certification | Non-explosion-proof (not for hazardous areas) |
| Pressure Compensation | Built-in atmospheric pressure compensation |
| Temperature Control | Precision thermostatic regulation of sensor block |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Thermo Fisher 8000 Series Online Gas Chromatograph |
| Pricing | Available Upon Request |
| Brand | PROCESS INSTRUMENTS |
|---|---|
| Origin | USA |
| Model | CG1000 |
| Type | Portable Oxygen Analyzer |
| Application | Industrial Process Control & Online Monitoring |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Tianyan Instrument Co., Ltd. |
| Model | TY-NIR-HT |
| Temperature Range | 0–500 °C |
| Moisture Range | 0–100 wt% |
| Moisture Accuracy | ±0.2 wt% (under stable composition conditions) |
| Temperature Accuracy | ±1% FS or ±1.5 °C |
| Optical Spot Diameter | 60–75 mm |
| Measurement Height Adjustment Range | 350 mm ± 100 mm |
| Filter Cycle | 1–60 s |
| Number of Calibration Channels | 50 |
| Optical Window | High-borosilicate quartz glass |
| Power Supply | 220 VAC / 50 Hz |
| Power Consumption | 60 W |
| Ingress Protection | IP65 |
| Curve Fitting | Supports >10 auto-calibration points per moisture calibration curve |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Model | TY-NIR-HT |
| Measurement Principle | Near-Infrared Reflectance Spectroscopy (NIRS) |
| Moisture Range | 0–100% w/w |
| Moisture Accuracy | ±0.2% (dependent on material composition stability) |
| Temperature Monitoring | Integrated infrared port, range 0–500 °C, accuracy ±1% FS or ±1.5 °C |
| Optical Spot Diameter | 60–75 mm |
| Installation Height Range | 350 mm ± 100 mm |
| Sampling Channels | 50 |
| Light Source | Imported high-efficiency NIR source |
| Filter Cycle | 1–60 s adjustable |
| Optical Window | High-borosilicate quartz glass |
| Power Supply | 220 VAC, 50 Hz |
| Power Consumption | 60 W |
| Enclosure Rating | IP65 |
| Calibration Support | Auto-calibration with ≥10 user-defined moisture calibration points |
| Operating Environment | High-temperature industrial settings |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Tianyan Instrument Co., Ltd. |
| Model | TY-NIR-T |
| Measurement Principle | Near-Infrared Reflectance Spectroscopy (NIRS) |
| Measurement Range | 0–100% w/w (water content by weight) |
| Accuracy | ±0.2% w/w (dependent on material homogeneity and spectral stability) |
| Light Source | Imported high-stability NIR LED array |
| Optical Spot Diameter | 60–75 mm |
| Working Distance | 350 mm ± 100 mm |
| Spectral Channels | 50 discrete wavelength bands |
| Filter Integration Time | 1–60 s adjustable |
| Probe Window Material | High-borosilicate quartz glass |
| Operating Temperature | −40 °C to +70 °C |
| Relative Humidity | 5–95% RH (non-condensing) |
| Enclosure Rating | IP65 |
| Power Supply | 220 VAC, 50 Hz |
| Output Interfaces | RS485, 4–20 mA analog, RS232, Ethernet (LAN), LoRa wireless |
| Display | Integrated industrial-grade capacitive touchscreen |
| Probe Housing | Anodized aluminum alloy (ASTM B557-19 compliant) |
| Signal Processing | Full digital signal chain with adaptive noise filtering and baseline correction |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 1,700 (FOB) |
| Compliance | GB/T 4857.3–1992, GB/T 4857.4–1992 |
| Load Capacity | Up to 5,000 N (configurable) |
| Displacement Resolution | 0.01 mm |
| Test Speed Range | 1–500 mm/min (adjustable) |
| Data Storage | 20 test records |
| Output | Thermal printer interface, USB data export |
| Brand | FPI (Focus Photonics) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-made) |
| Model | UTS-2000 |
| Pricing | Upon Request |
| Brand | Vaisala |
|---|---|
| Origin | Finland |
| Manufacturer | Vaisala Oyj |
| Type | Optimus™ OPT100 DGA |
| Application | Online dissolved gas analysis (DGA) for sealed power transformers |
| Measurement Principle | Non-dispersive infrared (NDIR) spectroscopy with vacuum-assisted headspace gas extraction |
| Calibration | Automatic in-situ zero/span correction using internal reference gas cell |
| Materials in contact with oil | 316 stainless steel and anodized aluminum |
| Pumping system | Magnet-driven gear pump |
| Maintenance interval | Maintenance-free design (no consumables, no scheduled servicing) |
| Installation time | <2 hours |
| Data output interval | Configurable down to 1-hour intervals (no data averaging required) |
| User interface | Web-based HTML5 interface with TLS-secured remote access |
| Environmental rating | IP65 enclosure |
| Compliance | Designed for IEC 60599, IEEE C57.104, and compatible with ISO/IEC 17025-accredited DGA workflows |
| Brand | VC Plasma |
|---|---|
| Model | JBT460 |
| Track Length | 850 mm |
| PCB Size Range | 30–460 mm |
| Conveyor Height | 900 ± 20 mm |
| Transmission Direction | Left-to-Right or Right-to-Left |
| Power Supply | 220 V / 50 Hz |
| Control System | Single-Chip Microcomputer |
| Conveyor Type | Flat Belt |
| Communication Interface | Dual SMEMA (Standardized Machine Equipment Manufacturer’s Association) |
| Dimensions (L×W×H) | 850 × 820 × 1100 mm |
| Brand | VC Plasma |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Dry Ice Capacity Options | 20 kg / 40 kg / 60 kg / 100 kg |
| Core Insulation Materials | Vacuum Insulation Panels (VIPs, 280–330 kg/m³) + Hollow Density Board (90 kg/m³) + Polyurethane (PU) Foam (55–60 kg/m³) |
| Thermal Conductivity (λ) | <0.0025 W/m·K |
| Average Daily Dry Ice Sublimation Rate | ≤5% |
| Brand | VC Plasma |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Application | Plasma Process Simulation & Industrial Plasma Source Driving |
| Key Features | Simple Operation, High Cost Performance, Low-Temperature Anti-Static Design, Compatible with Pointed and Rotating Transmitters |
| Brand | VC Plasma |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Power Architecture | DPM-Based Digital Platform |
| Input Power Factor Correction (PFC) | Integrated |
| Output Topology | High-Efficiency Full-Bridge Inverter |
| Output Waveform | Quasi-Sinusoidal |
| Control Method | Vector-Controlled Constant-Power Delivery |
| Frequency Management | Digital Variable-Frequency & Dynamic Frequency-Hopping |
| Human-Machine Interface | Touchscreen with Real-Time Parameter Visualization |
| Operating Temperature Range | 50–70 °C (customizable) |
| Output Potential | <23 V (customizable) |
| Energy Intensity Monitoring | Integrated Spectroscopic Detection |
| Emitter Compatibility | Direct-Injection & Rotary Plasma Emitters |
| Fault Diagnostics | 21-Channel Real-Time Fault Logging & Alarm System |
| Monitoring Capabilities | Dual-Loop Real-Time Supervision of Power Supply (voltage, current, power, air pressure, operating frequency, spray gun RPM, module temperature, fan status, communication integrity) and Motor Subsystem (voltage, current, power, torque, operational mode, health index, communication return rate, speed profile) |
| Brand | VC Plasma |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | NA |
| Pricing | Available Upon Request |
| Brand | Vcam |
|---|---|
| Model | GA2000 CH1-14 |
| Origin | Guangdong, China |
| Channel Capacity | 2–14 configurable analog input channels |
| Measurement Range | 1 ppm – 25% O₂ (full-scale selectable per channel) |
| Accuracy | ±3% of reading for 25%–1% O₂ |
| Response Time (T90) | <60 s |
| Output Interface | 4–20 mA / RS485 Modbus RTU / Ethernet (optional) |
| Compliance | Designed to support GLP/GMP-aligned process validation and FDA 21 CFR Part 11 audit-trail readiness via optional software module |
| Brand | Vcam |
|---|---|
| Model | GA2000-1 |
| Origin | Guangdong, China |
| Measurement Range | 25%–1% ±3% |
| Response Time | T90 < 60 s |
| Brand | Vcam |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NS100 |
| Pricing | Available Upon Request |
| Brand | VEGA |
|---|---|
| Origin | Germany |
| Manufacturer | VEGA Grieshaber KG |
| Product Type | Conductive Level Switch |
| Model | EL 1 |
| Electrode Insulation | PTFE |
| Max. Electrode Length | 4 m |
| Compatible Controllers | VEGATOR 131, VEGATOR 132, VEGATOR 130 Series |
| Application | Overflow & Dry-Run Protection |
| Compliance | ATEX, IECEx, SIL 2 (per IEC 61508), RoHS, CE |