Other Non-destructive Testing Equipment
Filter
Showing 1–30 of 32 results
| Brand | ACS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A1040 MIRA 3D |
| Frequency Bandwidth | 10–100 kHz |
| Parallel DAQ Channels | 32 |
| Maximum Penetration Depth | 3 m (concrete-dependent) |
| Maximum Coverage Area | 10 × 10 m |
| Frame Rate | 25 Hz (2D), 2 Hz (3D) |
| Battery Life | Up to 10 h per charge |
| Sensor Configuration | 4 × 8 A-DPC® array (expandable) |
| Compliance | T/CECS XXX-202X, JGJ/T 485-2019, DB32/T 3754-2020, DB34/T 5072-2017, DB37/T 5106-2018, DG/TJ 08-2252-2018, DB13(J)/T 8327-2019, DBJ/T-199-2020 |
| Brand | ACS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A1040 MIRA 3D Pro |
| Frequency Bandwidth | 10–100 kHz |
| Parallel DAQ Channels | 64 |
| Maximum Penetration Depth | 4 m (concrete-dependent) |
| Maximum Scanning Area | 10 × 10 m |
| Frame Rate | 12 Hz (2D), 0.3 Hz (3D) |
| Battery Life | Up to 10 h per charge |
| Sensor Configuration | 4 × 16 or 8 × 8 A-DPC® array (expandable) |
| Compliance | T/CECS XXX-202X, JGJ/T 485–2019, DB32/T 3754–2020, DB34/T 5072–2017, DB37/T 5106–2018, DG/TJ 08–2252–2018, DB13(J)/T 8327–2019, DBJ/T–199–2020 |
| Brand | ACS |
|---|---|
| Origin | Hong Kong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | A1052 MultiSONIC |
| Price Range | USD 1–2 (Unit Price Indicative |
| Channels | 32-channel pulser-receiver array |
| Connectivity | Integrated Wi-Fi interface (IEEE 802.11 b/g/n, 2.4 GHz) |
| Power Supply | Rechargeable Li-ion battery (operational autonomy ≥ 6 h) |
| Excitation | Bipolar pulse burst with user-defined frequency, half-cycle duration, and number of half-cycles |
| Compatible Transducers | All ACS dry-point contact ultrasonic transducers (e.g., A101x series, 20–500 kHz nominal bandwidth) |
| Encoding Support | Golay complementary sequence excitation (length up to 64 bits) |
| Software | MATHILDA32 (free demonstration version included) |
| Operating Modes | Pulse-echo, through-transmission, pitch-catch |
| Compliance | CE, RoHS, FCC Part 15 Subpart B |
| Brand | ACS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A1410 Pulsar |
| Price | USD 6,800 (FOB Italy) |
| Brand | ACS |
|---|---|
| Origin | Russia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A1040 MIRA |
| Pricing | Upon Request |
| Brand | ADVANTEST |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | TS9001 TDR Analysis System |
| Price | USD 70,000 (FOB Shanghai) |
| Brand | Aisida |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Zhengye XG5120 |
| Quotation | Available Upon Request |
| Detection Efficiency | ≥60 ppm |
| False Positive Rate | ≤2% |
| False Negative Rate | 0% |
| Yield Accuracy | 99.5% |
| Measurement Resolution | 40 µm |
| Radiation Dose Rate | ≤1 µSv/hr (per IEC 61000-4-2 & ISO 13783 compliance) |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Model | ARB-IPR-1210 (PCI-E) |
| Bus Interface | PCI Express |
| ADC Resolution | 12-bit |
| Sampling Rate | 100 MSPS (selectable: 100/50/25/10/5 MSPS) |
| Input Bandwidth | 0.5–30 MHz (+3 dB) |
| Gain Range | –20 to +80 dB (0.1 dB step) |
| Pulse Generator | Up to 400 V peak (<5 ns rise time), programmable pulse width & damping |
| DAC Memory | 128 KB RAM (64K points) |
| Trigger Modes | Software, external TTL, signal threshold |
| Gate Count | 4 independent gates |
| Time-of-Flight Resolution | 16-bit (10 ns) |
| Amplitude Resolution | 12-bit (488 µV) |
| Operating Temperature | 5–40 °C |
| Form Factor | Full-length PCI-E card |
| Compliance | RoHS, CE, FCC Class A |
| Software Support | LabVIEW and C++ drivers included |
| Standards Compatibility | Designed for ASTM E1158, ISO 12718, and EN 12668-1 compliant ultrasonic testing workflows |
| Brand | Astroda |
|---|---|
| Model | XG5120 |
| Origin | Guangdong, China |
| X-ray Tube Voltage | 90 kV |
| X-ray Tube Current | 200 µA |
| Focal Spot Size | 5 µm |
| Cooling Method | Forced Air Cooling |
| Detection Accuracy | 40 µm |
| Radiation Leakage | ≤1 µSv/hr (per IEC 61331-1 & FDA 21 CFR §1020.40) |
| Throughput | ≥30,000 units/day |
| Reconfiguration Time | 0.5–2 h |
| Compliance | CE, ISO 13485 (for medical device manufacturing support), GB/T 18871-2002, IEC 62495 |
| Brand | Astroda |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | XG5130 |
| Pricing | Available Upon Request |
| X-ray Tube Voltage | 90 kV |
| X-ray Tube Current | 200 µA |
| Focal Spot Size | 5 µm |
| Cooling Method | Forced Air Cooling |
| Detection Accuracy | 40 µm |
| Radiation Leakage | ≤1 µSv/hr (compliant with IEC 61000-4-3 & IEC 62471) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PAL-HIKARi 15 |
| Pricing | Available Upon Request |
| Brand | Force |
|---|---|
| Origin | Denmark |
| Model | ERE 20 |
| Type | Embedded Half-Cell Reference Electrode |
| Electrode Material | Manganese Dioxide (MnO₂) |
| Electrolyte pH | ~13.5 |
| Housing | Stainless Steel (AISI 316) |
| Ionic Membrane | Cementitious Mortar |
| Input Impedance Requirement | >100 MΩ |
| Compliance | EN 12696:2016, ASTM C876, ISO 15663-2 |
| Installation | Embeddable in Fresh or Existing Concrete |
| Output Interface | Standard BNC or Screw-Terminal Voltage Output |
| Operating Temperature Range | −10 °C to +60 °C |
| Long-Term Drift | < ±2 mV/year (typical, under stable alkaline conditions) |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | MagStress5c |
| Measurement Principle | Magnetic Barkhausen Noise (MBN) Analysis |
| Portability | Integrated battery-powered handheld unit with touch display and USB interface |
| Compliance | Designed for field-deployable NDT per ISO 10893-13 and ASTM E3027 guidelines |
| Sample Type | Ferromagnetic metallic components (e.g., bearing races, gear teeth, camshafts, turbine blades) |
| Output | Real-time MBN amplitude & frequency spectrum, quantitative burn index, pass/fail classification |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | StrainMaser Components |
| Pricing | Available Upon Request |
| Brand | LAwave |
|---|---|
| Origin | Germany |
| Model | LAwave |
| Type | Laser-based Surface Acoustic Wave (SAW) Dispersion Analyzer |
| Application | Thin-film elastic property characterization |
| Compliance | Designed for ISO/IEC 17025-aligned laboratories, compatible with GLP/GMP data integrity workflows |
| Brand | NCS (China Steel Research Institute) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | NC-CUT Series |
| Pricing | Upon Request |
| Brand | NCS (China Iron and Steel Research Institute Group) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | NC-GUFT Series |
| Pricing | Available Upon Request |
| Brand | NCS (China Iron and Steel Research Institute Group) |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | NC-C-SC-AN Series for Steel Plate Inspection |
| Ultrasound Channels | 16 (expandable to 64 via cascading) |
| Probe Configuration | Up to 4 probes, 128 total elements |
| Phased Array Beamforming Capacity | 1024 delay laws |
| Data Throughput | 40 MB/s via Gigabit Ethernet |
| Network Interface | Industrial Power + Dual-Mode Fiber Optic |
| Encoder Input | 2-channel quadrature (A/B phase) |
| Trigger Mode | Internal or External (software-selectable) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| TCG (Time-Corrected Gain) | Integrated |
| Minimum Detectable Flaw | Ø3 mm flat-bottom hole (FBH) at full material thickness |
| Scanning Coverage | Adjustable multi-probe array with 15 mm overlap per 120 mm probe |
| Mechanical Architecture | Immersion-type water bath with dual staggered probe carriage assemblies |
| Compliance Standards | ISO 3183, GB/T 2970, ASTM A435, ASTM A578, ISO 10893-11 |
| Brand | NCS (China Iron and Steel Research Institute Group) |
|---|---|
| Model | NC-C-SCAN Series |
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Pricing | Available Upon Request |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | NC-DMT Series |
| Pricing | Available Upon Request |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | NC-MT Series |
| Pricing | Available Upon Request |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Domestic (China) |
| Model | NC-Series |
| Pricing | Available Upon Request |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Producer |
| Country of Origin | Domestic (China) |
| Model | NCS-MMTI600 |
| Price | USD 1 (Reference Only) |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer | NCS (National Center for Steel Research) |
| Type | Domestic |
| Model | NCS-RBET Series |
| Pricing | Upon Request |
| Brand | Neocera |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Magma EFI HiRes |
| Pricing | Upon Request |
| Brand | Neocera |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Magma EFI |
| Pricing | Upon Request |
| Brand | Neocera |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Magma SSM HiRes |
| Pricing | Available Upon Request |
| SQUID Spatial Resolution | 3 µm |
| HiRes Spatial Resolution | 250 nm |
| SQUID Scan Area | ≥100 mm × 100 mm |
| HiRes Scan Area | ≥100 mm × 100 mm |
| SQUID Current Sensitivity | 500 nA @ 333 µm, 1.5 µA @ 1000 µm |
| HiRes Current Sensitivity | 5 µA @ 2 µm, 100 µA @ 100 µm |
| SQUID Magnetic Field Sensitivity | 15 pT/√Hz (typ.) |
| HiRes Magnetic Field Sensitivity | 10 nT/√Hz (typ.) |
| SQUID Operating Frequency Range | DC–25 kHz |
| HiRes Operating Frequency Range | 10 kHz–200 kHz |
| SQUID Imaging Depth | ≤10 mm |
| HiRes Imaging Depth | <100 µm |
| Excitation Source | ±10 V @ 100 mA, DC–200 kHz |
| Optical Lens Resolution | 2 µm (NIR/Visible) |
| Power Supply | 110–120 V @ 20 A or 220–240 V @ 10 A |
| OS | Windows 10 64-bit |
| Brand | Neocera |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Magma SSM |
| Pricing | Upon Request |
| Spatial Resolution (SQUID) | 3 µm |
| Scan Area (SQUID) | ≥100 mm × 100 mm |
| Current Sensitivity | 500 nA @ 333 µm |
| Magnetic Field Sensitivity | 15 pT/√Hz (typ.) |
| Imaging Depth | 10 mm |
| SQUID Operating Frequency Range | DC to 25 kHz |
| Function Generator | ±10 V @ 100 mA, DC to 200 kHz |
| Optical Lens Resolution | 2 µm (NIR/Visible) |
| Power Supply | 110–120 V @ 20 A or 220–240 V @ 10 A |
| OS | Windows 10 64-bit |
| Brand | Dantec Dynamics |
|---|---|
| Model | FlawScout |
| Technology | Laser Shearography (Speckle Pattern Shearing Interferometry) |
| Origin | Germany |
| Detection Area per Frame | Up to 0.1 m² |
| Typical Inspection Time | <30 s per measurement |
| Excitation Options | Thermal, Vacuum, or Mechanical Vibration |
| Compliance | Designed for ISO 27958, ASTM E2614, and EN 13794-compliant NDT workflows |
| Software | FlawScout Control & Reporting Suite with Audit Trail and Export Capabilities |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MIV-X |
| Pricing | Available upon Request |