| Brand | Aero Laser |
|---|---|
| Origin | Italy |
| Model | AL2021SC |
| Detection Principle | Enzyme-catalyzed fluorometric assay (horseradish peroxidase or catalase-based) |
| Linear Range | 0.1–2000 ppb (gas phase), 150 ng/L–5 mg/L (liquid phase) |
| LOD | <100 ppt (gas), <150 ng/L (liquid), <2×10⁻⁹ mol (liquid) |
| Response Time (10–90%) | 90 s |
| System Delay | ~300 s |
| Noise Level | ≤2% FS |
| Sample Temp. Range | >0 °C to +120 °C |
| Calibration | Auto-zero + semi-automated liquid standard calibration (optional) |
| Interface | Touchscreen GUI + remote operation via Android tablet or PC |
| Connectivity | LAN, RS232 |
| Data Logging | Internal memory + USB export |
| Software | SOL-based graphical data recording & visualization |
| Dimensions | 45 cm × 15 cm × 56 cm (19″ rack-mountable) |
| Weight | 15 kg |
| Power | 110/220 VAC, 110 W |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AL-6000 |
| Price Range | USD 21,000 – 28,000 |
| Brand | Ailun |
|---|---|
| Origin | Shandong, China |
| Model | AL-6800 |
| Measurement Range | 0–200 µg/L (standard), 0–2000 µg/L (extended) |
| Accuracy | ±2% F.S. |
| Resolution | 0.1 µg/L |
| Repeatability | ≤1.5% |
| Stability | ±1.5% F.S. / 4 h |
| Display | 7.0-inch color TFT touchscreen |
| Power Supply | 85–265 VAC, 45–65 Hz |
| Power Consumption | 30 W |
| Dimensions (L×W×H) | 280 × 310 × 180 mm |
| Weight | 5 kg |
| Enclosure | Stainless steel, IP65-rated housing |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory environments, supports GLP data integrity requirements |
| Brand | Ailun General (Qingdao Ailun) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AL-3010 |
| Price | USD 1,550 (approx.) |
| Flow Range | 0–40 m³/s |
| Sampling Frequency | 3 Hz |
| Level Measurement Accuracy | ≤ ±0.5 mm |
| Flow Measurement Accuracy | ≤ ±1% FS |
| Level Resolution | ≤ 0.1 mm |
| Output Interface | USB |
| Operating Temperature | 0–40 °C |
| Operating Humidity | ≤ 85% RH |
| Battery | 24 V DC Li-ion |
| Continuous Operation Time | 72 h |
| Dimensions | 400 × 300 × 110 mm |
| Weight | 4 kg |
| Brand | Ailun General (Qingdao Ailun) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AL-3020 |
| Liquid Level Range | 0–1000.0 mm (0.1 mm resolution, ≤ ±0.5 mm accuracy) |
| Atmospheric Pressure Range | 60–120 kPa (0.1 kPa resolution, ±0.5 kPa accuracy) |
| Ambient Temperature Range | −40 to +85 °C (0.1 °C resolution, ±2 °C accuracy) |
| Flow Measurement Error | ≤ ±1% |
| Compatible Weirs & Flumes | Triangular Notch Thin-Plate Weir, Rectangular Notch Thin-Plate Weir, Constant-Width Thin-Plate Weir, Parshall Flume |
| Operating Temperature | −5 to +40 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Noise Level | <50 dB |
| Host Weight | ~3.0 kg |
| Dimensions | 280 × 246 × 106 mm |
| Battery | 14.8 V / 10 Ah Li-ion, ≥12 h runtime |
| Power Input | 220 V AC, 50 Hz |
| Power Consumption | ≤40 W |
| Enclosure Rating | IP67 |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-H2 |
| Pricing | Upon Request |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-H2S |
| Price | Upon Request |
| Measurement Principle | Amperometric (Clark-type, 3-electrode) |
| Power Supply | 9–30 VDC |
| Output Signal | 0–5 VDC |
| Dimensions | Ø24 mm × 235 mm |
| Connector | SUBCONN BH-4-MP (optional alternatives available) |
| Warm-up Time | 5–15 min |
| Electrolyte Consumption | Low |
| Measurement Ranges | Type I: 0.05–10 mg/L H₂S |
| Type II | 0.5–50 mg/L H₂S |
| Type III | 0.01–3 mg/L H₂S |
| Accuracy | ±2% of reading |
| Operating Temperature | 0–30 °C |
| pH Range | 0–8.5 |
| Response Time (t₉₀) | <200 ms |
| Typical Service Life | 5–9 months |
| Pressure Rating | >10 bar |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-O3 |
| Pricing | Upon Request |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-ORP |
| Price | Upon Request |
| Measurement Range | ±2000 mV |
| Resolution | 0.1 mV |
| Accuracy | ±2 mV |
| Power Supply | 9.5–18 VDC |
| Output Signal | 0–5 VDC |
| Dimensions | Ø30 mm × 250 mm |
| Pressure Rating | 600 dbar |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Not Specified |
| Price | Upon Request |
| Dimensions | 220 mm × 160 mm × 250 mm |
| Power Supply | 230 V AC |
| Flow Rate | 10–12 mL/min |
| Dissolved Oxygen Range | 0.4 µg/L – 9.95 mg/L |
| Accuracy | ±0.25% of reading |
| Response Time | ≤5 min |
| Deoxygenation Efficiency | Residual O₂ < 35 µg/L |
| Deaeration Protocol | 45-min purge followed by ~5-min equilibration |
| Calibration Reference Method | Winkler titration per DIN 38408-21 (modified) |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | AMT G200 Coulometric H₂S Sulfide Generator |
| Price | Upon Request |
| Concentration Range | 0.002–60.0 mg/L H₂S (0.062–1871 µmol/L H₂S) |
| Electrode Capacity | ≈350 mAh |
| Dimensions | 220 mm (L) × 160 mm (W) × 250 mm (H) |
| Accuracy | ±0.25% (amperometric probe) |
| Purge Time | ~45 min |
| First Concentration Transition | ~15–30 min |
| Concentration Step Response Time | 1 h per 10 steps (dependent on step magnitude and gas flow rate) |
| Repeatability | 99.78% (amperometric), 97.51% (methylene blue) |
| Dry-Run Tolerance | ~4 working days |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | MS08 |
| Pricing | Upon Request |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | pH |
| Price | Upon Request |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Model | AMT-H2O2 |
| Electrode Configuration | 3-electrode amperometric |
| Membrane Material | Silicone elastomer |
| Output Signal | 0–5 V DC proportional to partial pressure (0–400 Pa) |
| Measurement Range (Type I) | 0.02–10% w/w H₂O₂ |
| Accuracy | ±1% of full scale |
| Response Time (t₉₀) | 1–2 s |
| Operating Temperature | 0–30 °C |
| pH Range | 0–11 |
| Pressure Rating | >10 bar |
| Housing Material | Titanium |
| Typical Service Life | 5–9 months |
| Polarization Time | 5–15 min |
| Probe Replaceability | Yes |
| Brand | ANDalyze |
|---|---|
| Origin | USA |
| Model | AND1100 |
| Measurement Principle | DNAzyme-based Fluorescence Detection |
| Detection Time | ≤60 s per sample |
| Detection Units | ppb or ppm |
| IP Rating | IP54 |
| Certifications | CE |
| Data Interface | USB |
| Software Update | Over-the-air via USB |
| Operating Languages | Multilingual (including Chinese) |
| Sensor Format | Discrete color-coded single-use cartridges |
| Sample Volume | 1 mL |
| Power | Rechargeable battery (USB charging) |
| Brand | ANDalyze |
|---|---|
| Origin | USA |
| Model | AND1100 |
| Detection Principle | DNAzyme-based Fluorescence Assay |
| Measurement Time | ≤60 s per sample |
| Detection Units | ppb or ppm |
| IP Rating | IP54 |
| Certifications | CE |
| Data Interface | USB |
| Software Updates | Over-the-air via USB |
| Operating Languages | English, Chinese, and others |
| Power | Rechargeable battery (USB charging) |
| Sample Volume | 1 mL |
| Sensor Format | Discrete, color-coded single-use cartridges |
| Brand | AQUALABO |
|---|---|
| Origin | France |
| Model | 110 Series |
| Cable Length Options | 15–100 m (aluminum frame) or 120–500 m (acrylic tripod) |
| Operating Temperature | −30 °C to +75 °C |
| Temperature Range | −15 °C to +80 °C |
| Temperature Accuracy | < ±0.1 °C |
| Probe Material | 316 stainless steel & nickel-plated brass |
| Probe Dimensions | Ø15 mm × 180 mm |
| IP Rating (Probe) | IP68 |
| IP Rating (Handle/Display Unit) | IP64 |
| Power Supply | 4 × 1.5 V AA batteries |
| Display | High-contrast LCD with tactile waterproof keypad |
| Acoustic & Visual Contact Detection | Yes |
| Optional Bottom Sensor for Depth Measurement | Yes |
| Calibration | Factory-calibrated |
| Brand | AQUALABO |
|---|---|
| Origin | France |
| Model | UVILINE 8100C / 9100C / 9400C |
| Wavelength Range | 320–1100 nm (8100C/9100C), 190–1100 nm (9400C) |
| Light Source | Tungsten-Halogen (8100C/9100C), Xenon Flash Lamp (9400C) |
| Spectral Bandwidth | 6 nm (8100C), 4 nm (9100C/9400C) |
| Wavelength Accuracy | ±2 nm (8100C), ±1 nm (9100C/9400C) |
| Wavelength Repeatability | ±0.5 nm |
| Absorbance Range | ±3300 Abs |
| Absorbance Resolution | 0.001 Abs or 0.1% T |
| Photometric Accuracy | ±0.005–0.016 Abs (dependent on range) |
| Stray Light | <0.1% at 340 nm (NaNO₂), <1% at 220–400 nm (GG375/GG408/NaI) |
| Baseline Stability | ±0.01 Abs |
| Scan Speed | Low/Medium/Fast |
| Interface | 1× USB-A, 1× USB-B |
| Power Supply | 110–220 V, 50/60 Hz |
| Operating Temperature | 10–35 °C |
| Dimensions (L×W×H) | 404 × 314 × 197 mm |
| Weight | 4.7 kg (8100C), 4.0 kg (9100C/9400C) |
| IP Rating | IP30 |
| Software | Spectralab v5.x (GLP-compliant) |
| Brand | AQUALABO |
|---|---|
| Origin | France |
| Model | UVILINE 9300 / UVILINE 9600 |
| Wavelength Range | 320–1100 nm (9300) / 190–1100 nm (9600) |
| Light Source | Tungsten-Halogen Lamp (9300) / Xenon Flash Lamp (9600) |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.5 nm |
| Absorbance Range | ±3500 Abs |
| Absorbance Resolution | 0.001 Abs or 0.1% T |
| Photometric Accuracy | ±0.003 Abs (0.5 Abs), ±0.005 Abs (1.0 Abs), ±0.010 Abs (2.0 Abs) |
| Stray Light | <0.1% T at 340 nm (GG375), <0.05% T at 340 nm (GG375) for 9600 |
| Baseline Stability | ±0.002 Abs |
| Scan Speed | >600 nm/min (9300), >800 nm/min (9600) |
| Interface | USB-A, USB-B, RJ45 |
| IP Rating | IP30 |
| Power Supply | 110–220 V, 50/60 Hz |
| Operating Temperature | 10–35 °C |
| Dimensions | 404 × 197 × 314 mm |
| Weight | 4 kg |
| Brand | Aquaread |
|---|---|
| Origin | United Kingdom |
| Model | AP-7000 |
| IP Rating | IP68 (submersible to 100 m) |
| Operating Temperature | −5 °C to +50 °C |
| Dimensions (L × Ø) | 450 mm × 77 mm |
| Weight (without cable) | 1350 g |
| Standard Optical Sensors | Dissolved Oxygen (optical), pH, ORP, EC, Depth, Temperature |
| Additional Sensor Capacity | 6 configurable ISE or optical sensor ports |
| Communication Interfaces | SDI-12 and Modbus RTU (RS-485) on AP-7000-SDI variant |
| Data Acquisition Modes | Real-time handheld reading (via Aquameter), autonomous logging (Aquaread Logger), and telemetry (Aquaread Telemetric System) |
| Brand | Aquaread |
|---|---|
| Origin | United Kingdom |
| Model | LeveLine |
| Power Source | 3.6 V Lithium Battery (10-year typical operational life) |
| Sampling Rate | Up to 10 Hz |
| Memory Capacity | 500,000 data points |
| Pressure Range Options | Absolute (up to 500 m H₂O) or Gauge (vented) |
| Housing Material | Titanium alloy body with corrosion-resistant connectors |
| Sensor Type | High-accuracy piezoresistive ceramic pressure sensor + NTC thermistor |
| Cable Options | Kevlar-reinforced vented (gauge) or unvented (absolute) cable |
| Optional Accessories | LeveLine-BARO barometric compensation unit, GPS-enabled LeveLine Meter, QuickDeploy Key |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 8000 (HM-1, HM-2, HM-3) and AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Measurement Range | Sub-ppb to ppm |
| Electrode Options | Gold, Mercury-film, Bismuth-film, and Bare Carbon Working Electrodes |
| Output Interfaces | Dual 4–20 mA analog outputs, RS-232, RS-485 |
| Compliance | Designed for ASTM D3559, ISO 11929 (uncertainty evaluation), USP <232>/<233>, and EPA Method 7000B |
| Software | Onboard data logging with timestamped audit trail, GLP-compliant reporting |
| Enclosure Rating | IP65 (AVVOR 8000 series), IP67 (AVVOR 9000 outdoor cabinet) |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AVVOR 8000 HM-1 |
| Price | Upon Request |
| Detection Principle | Anodic Stripping Voltammetry (ASV) & Cathodic Stripping Voltammetry (CSV) |
| Detection Range | Sub-ppb to low ppb levels (e.g., As(III): 0.05–100 µg/L |
| Cd | 0.02–50 µg/L |
| Pb | 0.03–100 µg/L |
| Hg | 0.01–20 µg/L |
| Cu | 0.05–200 µg/L |
| Zn | 0.1–500 µg/L |
| Ni, Cr, Mn | optional with dedicated electrodes) |
| Measurable Elements | As(III), Total As, Cd, Cr(VI), Cu, Pb, Hg, Mn, Ni, Zn |
| Operating Temperature | –20 °C to +70 °C |
| IP Rating | IP67 |
| Data Storage | 1,000 measurement records with sample ID, timestamp, and operator notes |
| Power Options | Rechargeable Li-ion battery (≥50 assays per charge), AC adapter, 12 V DC car socket |
| Display | 128 × 128 pixel backlit monochrome LCD |
| Interface | Joystick navigation, USB 2.0 for data export and firmware/software updates |
| Electrode System | Triple-electrode immersed probe (working, reference, counter), integrated stirrer and Pt100 temperature sensor |
| Expandability | Up to three working electrodes simultaneously installed |
| Compliance | CE-marked |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 8000 (portable), AVVOR 9000 (online) |
| Measurement Principle | Anodic Stripping Voltammetry (ASV) / Differential Pulse Anodic Stripping Voltammetry (DP-ASV) |
| Detection Range | Sub-ppb to low ppb (e.g., 0.05–100 µg/L, matrix-dependent) |
| Supported Elements | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U |
| Electrode Options | Gold, Mercury-film, Bismuth-film, Bare Carbon |
| Compliance | US EPA Methods 7063, 7472, 1001 |
| Output Interfaces | 4–20 mA (×8), RS-232, RS-485 |
| Data Management | Onboard LCD (AVVOR 8000), Dual-screen option (AVVOR 9000), PC software with audit trail, GLP-compliant reporting |
| Power | Rechargeable Li-ion battery (AVVOR 8000) |
| Enclosure Rating | IP67 (AVVOR 8000) |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVVOR 9000 |
| Pricing | Upon Request |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Measurable Elements | As, Hg, Se, Zn, Cd, Pb, Cu, Mn, Sb, Sb³⁺, Tl, Fe, Ni, Sn, Cr, Cr⁶⁺, Co, Mo, Au, Ag, Pd, U |
| Electrode Options | Gold, Mercury-film, Bismuth-film, Bare Carbon |
| Max Modules | 2 |
| Max Simultaneous Parameters per Module | 5 |
| Analog Outputs | 8 × 4–20 mA |
| Digital Interfaces | RS-485, RS-232 |
| Compliance | Designed for ASTM D3559, ISO 11885, EPA Method 7063, and USP <232>/<233> trace metal guidance |
| Environmental Rating | IP65 enclosure with humidity-resistant design |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Electrode Options | Gold, Mercury-plated, Bismuth-plated, and Bare Carbon Working Electrodes |
| Max Simultaneous Metals | 5 per module (up to 2 modules) |
| Output Interfaces | 8 × 4–20 mA analog outputs, RS-485 & RS-232 digital interfaces |
| Compliance | Designed for continuous unattended operation in compliance with ISO 10560, ASTM D3559, and EPA Method 7063 for trace metal analysis in aqueous matrices |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Measurable Elements | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U |
| Electrode Options | Gold, Mercury-Film, Bismuth-Film, Bare Carbon |
| Max Modules | 2 |
| Simultaneous Parameters per Module | Up to 5 |
| Analog Outputs | 8 × 4–20 mA |
| Digital Interfaces | RS-485, RS-232 |
| Compliance | Designed for EPA Method 7063, ISO 11969, ASTM D3559, and GLP/GMP-aligned data integrity protocols |
| Brand | SYSTEA |
|---|---|
| Model | EasyColi |
| Measurement Principle | Standard Enzyme-Substrate Method (MPN, P/A, TTD) |
| Compliance | HJ 1001-2018, ISO 9308-1:2014 |
| Detection Limit | 1 MPN/100 mL |
| Upper Detection Range | >20,000 MPN/100 mL |
| Sample Throughput | 28 fully automated MPN tests per cycle |
| Sample Independence | Individual incubation chambers per sample |
| Integrated Cleaning Station | Yes |
| Regulatory Support | GLP-compliant data logging, audit trail enabled |
| Software Interface | Touchscreen GUI with real-time assay progress visualization |
| Application Scope | Surface water, drinking water, groundwater, recreational bathing waters, municipal wastewater, industrial effluents |
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China |
| Model | EasyTox Max |
| Detection Principle | Bioluminescent Bacterial Inhibition Assay (using *Aliivibrio fischeri*, *Photobacterium phosphoreum*, or *Vibrio qinghaiensis* Q67) |
| Toxicity Output | % Inhibition (qualitative) and EC50 (quantitative, 160× dilution capability) |
| Measurement Frequency | As fast as 2.5 min/cycle |
| Exposure Time | Programmable from 5 min to 24 h |
| Compliance | ISO 11348-3, GB/T 15441 |
| Reagent Storage | Integrated 4–8 °C refrigerated compartment |
| Cleaning | Automated washing station with dedicated rinse cycles |
| Control Interface | Industrial-grade capacitive touchscreen with full programmability |
| Bacterial Maintenance Interval | 8–16 weeks (with on-board reactivation of lyophilized cultures) |