Other X Ray Diffractometers
Filter
Showing all 6 results
| Brand | Auniontech |
|---|---|
| Model | micro-CT |
| X-ray Tube Voltage | Up to 200 kV |
| Detector Resolution | Up to 16 MP |
| Scan Speed | < 10 s per scan |
| Number of Projections | Up to 8-axis acquisition |
| Spatial Resolution | 0.4 µm – 5 µm |
| System Weight | 20 kg (CT-PORTABLE variant) |
| Radiation Leakage | < 1 µSv/h |
| Power Output | Up to 65 W (CT-XPRESS variant) |
| Brand | Auniontech |
|---|---|
| Model | MICRO FOCUS X |
| Target Spot Size | 5–10 µm (power-dependent) |
| Operating Voltage | 20–100 kV |
| Max Power | 15 W |
| Focus-to-Window Distance (FOD) | 7 mm |
| Anode Material | Tungsten (W) / Copper (Cu) |
| Input Power | 24 VDC / 2 A |
| Weight | 4.5 kg |
| Dimensions | 524 × 490.25 × 206.5 mm |
| Window Thickness | 0.254 mm |
| Beam Divergence | 95° conical |
| Cooling | Integrated fan (sufficient for ambient ≤28°C) |
| Operating Temp | +10°C to +40°C |
| HV Ripple (full load) | ≤0.1% p-p |
| Voltage/Current Regulation | ±0.25% |
| Interface | RS-232C |
| OS Compatibility | Windows 7/8.1/10 |
| Window Type | Side-window and end-window configurations available |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MED-1 |
| Price | €200,000 |
| Brand | BosinTech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | FD-25 |
| Pricing | Available Upon Request |
| Brand | Pulstec |
|---|---|
| Origin | Japan |
| Model | s-Laue/m-Laue |
| X-ray Source | Tungsten anode |
| Voltage/Current | 30 kV / 1.6 mA |
| Cooling | Air-cooled |
| Irradiation Spot Size | φ0.8 mm (standard collimator) |
| Sample-to-Detector Distance | 33 mm |
| Typical Exposure Time | 15 s |
| Sample Stage | 6-axis (Θ, translation, radial, X, Y, Z) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Max. Power Consumption | 150 W |
| Safety | Integrated door interlock |
| Dimensions (s-Laue) | 224 × 414 × 480 mm |
| Dimensions (m-Laue) | 800 × 600 × 600 mm |
| XY Translation Stage | Included on m-Laue only |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | Miniflex 600 |
| X-ray Tube Power | 600 W |
| Dimensions (W×H×D) | 560 × 700 × 395 mm |
| Weight | 80 kg |
| Goniometer Accuracy | ±0.01° 2θ |
| Safety | Interlocked X-ray shutter with automatic beam cutoff during sample loading |
| Detector | Standard scintillation counter |
| Sample Stage | Manual stage standard |
| Software Suite | PDXL (with ICDD PDF-4+ database), Qualitative & Quantitative Analysis modules, Multi-scan acquisition, Dust-specific quantification (e.g., respirable crystalline silica per ISO 16258-1, NIOSH 7500) |