Oxygen Nitrogen Analyzer
Filter
Showing all 22 results
| Brand | Baoying |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Oxygen-Nitrogen Analyzer |
| Model | ON-316 |
| Detection Principle | Inert Gas Fusion Coupled with Non-Dispersive Infrared (NDIR) and Thermal Conductivity Detection (TCD) |
| Oxygen Range | 0.1 ppm – 5000 ppm (low), 0.5% – 20% (high) |
| Nitrogen Range | 0.1 ppm – 5000 ppm (low), 0.5% – 50% (high) |
| Detection Limit | 0.01 ppm |
| Accuracy | ±1 ppm or RSD ≤ 1% (O₂/N₂) |
| Analysis Time | O₂: 120–180 s |
| N₂ | 120–240 s |
| Pulse Furnace Power | 8.0 kW |
| Detector Configuration | Dual-channel NDIR for oxygen, TCD for nitrogen |
| Sample Form | Solid metals and non-metals (powders, chips, rods, pellets) |
| Compliance Support | ASTM E1019, ISO 14284, GB/T 11261, JIS G 1211 |
| Brand | Baoying Technology |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ONH-316 |
| Instrument Type | Oxygen/Nitrogen/Hydrogen Elemental Analyzer |
| Oxygen Range | Low-O: 0.1–5000 ppm |
| High-O | 0.5–20 wt% |
| Nitrogen Range | Low-N: 0.1–5000 ppm |
| High-N | 0.5–50 wt% |
| Hydrogen Range | 0.1–5000 ppm |
| Accuracy | O/N: ±1 ppm or RSD ≤ 1% |
| H | ±0.2 ppm or RSD ≤ 2% (relative to certified reference material uncertainty) |
| Sensitivity | 0.01 ppm |
| Analysis Time (O) | 120–180 s |
| Pulse Furnace Power | 8.0 kW |
| Brand | Baoying |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Oxygen-Nitrogen-Hydrogen Analyzer |
| Model | ONH-316 |
| Detection Principle | Inert Gas Fusion Coupled with Non-Dispersive Infrared (NDIR) and Thermal Conductivity Detection (TCD) |
| Oxygen Range | High-O: 0.5–20 wt% |
| Low-O | 0.1–5000 ppm |
| Nitrogen Range | High-N: 0.5–50 wt% |
| Low-N | 0.1–5000 ppm |
| Hydrogen Range | 0.1–5000 ppm |
| Precision | O/N: ±1 ppm or RSD ≤ 1% |
| H | ±0.2 ppm or RSD ≤ 2% |
| Sensitivity | 0.01 ppm |
| Analysis Time | O: 120–180 s |
| N | 120–240 s |
| H | 120–180 s |
| Pulse Furnace Power | 8.0 kW |
| Detector Configuration | Dual-channel NDIR for O/C (CO), Single-channel TCD for H₂ and N₂ |
| Gas Handling | EPC-controlled pneumatic architecture with independent electronic pressure control (EPC) per gas path |
| Calibration Options | Single-point, multi-point, and slope/intercept correction |
| Software Compliance | Audit trail, user-level access control, data export in CSV/Excel, optional 21 CFR Part 11 compliance module |
| Structural Design | Integrated monolithic chassis housing furnace, gas analysis module, electronics, and industrial-grade embedded PC |
| Brand | Baoying Technology |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Line | TC-306 Series |
| Instrument Type | Oxygen-Nitrogen-Hydrogen Elemental Analyzer |
| Analytical Range | O: 0.1 ppm – 10 wt% |
| Low N | 0.1 ppm – 5000 ppm |
| High N | 0.5 – 30 wt% |
| H | 0.1 ppm – 5000 ppm |
| Analytical Precision | O & N: ±1 ppm or RSD ≤ 1.0% |
| H | ±0.2 ppm or RSD ≤ 2.0% |
| Sensitivity | 0.01 ppm |
| Analysis Time | O: 120–180 s |
| N | 120–240 s |
| H | 120–180 s |
| Pulse Furnace Power | 8.0 kW |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | G4 PHOENIX DH |
| Detection Principle | Thermal Desorption Mass Spectrometry (TDMS) & Thermal Conductivity Detection (TCD) |
| Detection Limit | <1 ng/g (with optional quadrupole MS) / <50 ng/g (standard TCD) |
| Furnace Max Temp | 900 °C (IR-heated, low thermal mass) |
| Sample Chamber Diameter | 30 mm |
| Calibration | 10-volume automated gas standard system |
| Compliance | Fully compatible with ISO 3690, AWS A4.3, ASTM E1442, EN ISO 17025 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | G8 GALILEO |
| Detection Principle | Inert Gas Fusion (IGF) coupled with Thermal Conductivity Detection (TCD) and Mass Spectrometry (MS) |
| Mass Range | 0–100 amu/mz |
| Detection Limits | <1 ppb (ng/g) for H, O, N (1 g sample) |
| Measurement Method | Direct gas-phase analysis via Smart Molecule Sequence™ |
| Furnace Options | Water-cooled graphite electrode furnace with FusionControl™ real-time non-contact temperature monitoring |
| Optional External IR Furnace | For diffusion hydrogen analysis per ISO 360 and AWS A4.3 |
| Compliance | Designed for GLP/GMP environments |
| Automation | Fully automated sample/crucible handling, electrode cleaning, and 10-step gas dosing calibration |
| MS Configuration | Industrial-grade quadrupole mass spectrometer optimized for H₂, N₂, O₂, Ar, and H₂O detection with reference channel stabilization |
| Particle Filtration | Integrated high-capacity dust collector + inline particulate filter |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | ONH5000 |
| Instrument Type | Oxygen-Nitrogen-Hydrogen Analyzer |
| Oxygen Range | 0.00001–3.0 wt% |
| Nitrogen Range | 0.00001–3.0 wt% |
| Hydrogen Range | 0.00000–0.25 wt% |
| Oxygen Precision | ±0.0001 wt% or RSD ≤ 1.0% |
| Nitrogen Precision | ±0.0001 wt% or RSD ≤ 1.0% |
| Hydrogen Precision | ±0.00002 wt% or RSD ≤ 2.0% |
| Sensitivity | 0.000001 wt% |
| Typical Analysis Time | 120–180 s (including purge, delay, and measurement) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Model | ONH5000 |
| Power Supply | 8.0 kW Pulse Electrode Furnace |
| Max Furnace Temperature | >3500 °C |
| Detection Principles | Infrared Absorption (O), Thermal Conductivity (N, H) |
| Carrier Gases | He or N₂ |
| Compliance | ASTM E1019, ISO 14284, GB/T 11261–2022, GB/T 20123–2006 |
| Sample Form | Solid metallic & non-metallic materials |
| Measurement Elements | O, N, H (simultaneous or individual) |
| Brand | KEGUO |
|---|---|
| Origin | Shanghai, China |
| Model | ONH-506S |
| Instrument Type | O/N/H Elemental Analyzer |
| Hydrogen Detector | Thermal Conductivity Detector (TCD) |
| Analytical Range | O: 0.1 ppm – 20 wt% |
| N | 0.1 ppm – 50 wt% |
| H | 0.01 ppm – 2.0 wt% |
| Precision | O: ±1 ppm or RSD ≤ 1.0% |
| N | ±1 ppm or RSD ≤ 1.0% |
| H | ±0.2 ppm or RSD ≤ 2.0% |
| Sensitivity | 0.001 ppm |
| Analysis Time | 120–240 s |
| Pulse Furnace Power | 8.5 kVA |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ONH836 |
| Analysis Range | 0.00005–50 mg |
| Instrument Type | Oxygen-Nitrogen-Hydrogen Analyzer |
| Method | Inert Gas Fusion (Graphite Crucible, Pulse Heating) |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | H5500 |
| Instrument Type | Oxygen-Nitrogen-Hydrogen Analyzer |
| Hydrogen Analysis Range | Low-H: 0.1–200 ppm |
| High-H | 200–5000 ppm |
| Hydrogen Precision | ±0.2 ppm or RSD ≤ 2.0% |
| Sensitivity | 0.01 ppm |
| Analysis Time | 3 min |
| Pulse Furnace | 0–1500 A, 8.5 kVA, Max Temp: 3500 °C |
| Carrier Gas | Ultra-High-Purity N₂ (≥99.9995%) |
| Dimensions | 63 × 76 × 76 cm (W×D×H) |
| Weight | ~180 kg |
| Brand | NCS (China Iron & Steel Research Institute Group – National Center for Steel Quality Inspection) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Pulse-heated Inert Gas Fusion Nitrogen Analyzer |
| Measurement Principle | Thermal Conductivity Detection (TCD) after High-Temperature Inert Gas Fusion |
| Analysis Range | Low-N: 0.1 ppm – 0.5% |
| High-N | 0.5% – 50% |
| Precision | ±1 ppm or RSD ≤ 1.0% |
| Sensitivity | 0.01 ppm |
| Analysis Time | ~3 min per sample |
| Furnace Power | 0–1500 A, 8.5 kVA, max. temperature 3500 °C |
| Sample Mass | Typically 1 g (adjustable per matrix and concentration) |
| Carrier Gas | Ultra-high-purity helium (≥99.9995%) |
| Dimensions | 63 cm (W) × 76 cm (D) × 76 cm (H) |
| Weight | ~180 kg |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer | NCS (Beijing Central Iron and Steel Research Institute) |
| Model | O5500 |
| Instrument Type | Oxygen Analyzer |
| Analysis Range | Low-Oxygen Mode: 0.1 ppm – 0.5% |
| High-Oxygen Mode | 0.5% – 20% (range adjustable via sample mass) |
| Precision | ±1 ppm or RSD ≤ 1.0% |
| Sensitivity | 0.01 ppm |
| Analysis Time | ~3 min |
| Pulse Furnace | 0–1500 A, 7.5 kVA, max. temperature 3500 °C |
| Sample Mass | Typically 1.0 g |
| Carrier Gas | Ultra-high-purity argon (≥99.9995%) |
| Dimensions | 63 cm (W) × 76 cm (D) × 76 cm (H) |
| Weight | ~180 kg |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer | NCS (Beijing Central Iron and Steel Research Institute) |
| Model | OH5500 |
| Instrument Type | Oxygen-Hydrogen Analyzer |
| Oxygen Range | Low-O: 0.1 ppm – 0.5 wt% |
| High-O | 0.5 wt% – 20 wt% |
| Hydrogen Range | Low-H: 0.1 ppm – 200 ppm |
| High-H | 200 ppm – 5000 ppm |
| Accuracy | O₂: ±1 ppm or ±1.0% RSD |
| H₂ | ±0.2 ppm or ±2.0% RSD |
| Sensitivity | 0.01 ppm |
| Analysis Time | 3 min |
| Pulse Furnace | 0–1500 A, 7.5 kVA, max. temp. 3500 °C |
| Detection Principle | Non-Dispersive Infrared (NDIR) for oxygen |
| Carrier Gas | Ultra-high-purity N₂ (≥99.9995%) |
| Sample Mass | Typically 1 g (adjustable to extend range) |
| Dimensions | 63 cm × 76 cm × 76 cm (W×D×H) |
| Weight | ~180 kg |
| Brand | NCS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Oxygen and Nitrogen Analyzer |
| Model | ON3500 |
| Oxygen Range (Low) | 0.1 ppm–0.5% |
| Oxygen Range (High) | 0.5%–20% |
| Nitrogen Range (Low) | 0.1 ppm–0.5% |
| Nitrogen Range (High) | 0.5%–50% |
| Oxygen Precision | 1 ppm or RSD ≤ 1.0% |
| Nitrogen Precision | 1 ppm or RSD ≤ 1.0% |
| Sensitivity | 0.01 ppm |
| Analysis Time | 3 min |
| Pulse Furnace Power | 8.5 kVA |
| Detectors | Dual-channel NDIR (O₂), TCD (N₂) |
| Carrier Gas | Ultra-high-purity He |
| Auxiliary Gas | Industrial-grade N₂ |
| Furnace Power Supply | 220 VAC ±10%, 50 A |
| Instrument Power Supply | 220 VAC ±10%, 10 A |
| Dimensions (Main Unit) | 58 cm × 70 cm × 68 cm (W×D×H) |
| Dimensions (Furnace Unit) | 48 cm × 70 cm × 68 cm (W×D×H) |
| Weight | 180 kg |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer | NCS (Beijing) Technology Co., Ltd. |
| Model | ON5500 |
| Instrument Type | Oxygen and Nitrogen Analyzer |
| Sample Mass | 1.0 g (adjustable) |
| Oxygen Range | Low-O: 0.1 ppm–0.5 % |
| High-O | 0.5 %–20 % |
| Nitrogen Range | Low-N: 0.1 ppm–0.5 % |
| High-N | 0.5 %–50 % |
| Accuracy | ±1 ppm or RSD ≤ 1.0 % |
| Sensitivity | 0.01 ppm |
| Analysis Time | ~3 min |
| Pulse Furnace | 0–1500 A, 7.5 kVA, max. temp. 3500 °C |
| Carrier Gas | Ultra-high-purity He (≥99.9995 %) |
| Dimensions | 63 cm (W) × 76 cm (D) × 76 cm (H) |
| Weight | ~180 kg |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer | NCS (Central Iron and Steel Research Institute) |
| Model | ONH3500 |
| Instrument Type | Oxygen-Nitrogen-Hydrogen Analyzer |
| Oxygen Range | 0.1 ppm–0.5% (low), 0.5%–20% (high) |
| Nitrogen Range | 0.1 ppm–0.5% (low), 0.5%–50% (high) |
| Hydrogen Range | 0.1 ppm–200 ppm (low), 200 ppm–5000 ppm (high) |
| Accuracy | O₂: ±1 ppm or RSD ≤1.0%, N₂: ±1 ppm or RSD ≤1.0%, H₂: ±0.2 ppm or RSD ≤2.0% |
| Sensitivity | 0.01 ppm |
| Analysis Time | 3 min |
| Furnace Power | 8.5 kVA |
| Detection Principle | Non-Dispersive Infrared (NDIR) for oxygen |
| Carrier Gas | Ultra-High-Purity Helium or Nitrogen |
| Power Supply | Furnace: 220 VAC ±10%, 50 A |
| Electronics | 220 VAC ±10%, 10 A |
| Dimensions (Main Unit) | 58 × 70 × 68 cm (W×D×H) |
| (Furnace Unit) | 48 × 70 × 68 cm (W×D×H) |
| Weight | 180 kg |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ONH5500 |
| Instrument Type | Oxygen-Nitrogen-Hydrogen Analyzer |
| Analysis Range | O (Low: 0.1 ppm–0.5 wt% |
| High | 0.5–20 wt%), N (Low: 0.1 ppm–0.5 wt% |
| High | 0.5–50 wt%), H: 0.1–2000 ppm |
| Accuracy | O/N: ±1 ppm or RSD ≤1.0% |
| H | ±0.2 ppm or RSD ≤2.0% |
| Sensitivity | 0.01 ppm |
| Analysis Time | 3 min |
| Pulse Furnace | 0–1500 A, 8.5 kVA, max. temperature ≥3500 °C |
| Carrier Gas | Ultra-high-purity He (≥99.9995%) |
| Dimensions | 63 × 76 × 76 cm (W×D×H) |
| Weight | ~180 kg |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | Customized-6 |
| Pricing | Available Upon Request |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | DH603-G4 |
| Instrument Type | Diffusion Hydrogen Analyzer |
| Analysis Range | 0.05–3000 mL/100g |
| Analytical Precision | 0.001 mL/100g |
| Sensitivity | ±1% |
| Analysis Time | 3–10 min |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Beijing, China |
| Model | ONH836-G8 |
| Analysis Range | O: 0.01 ppm–5 wt% |
| N | 0.01 ppm–3 wt% |
| H | 0.01 ppm–0.3 wt% |
| Analytical Precision | O/N: ±0.25 ppm |
| H | ±0.5 ppm |
| Detection Limit | 0.001 ppm |
| Analysis Time | 90 s |
| Pulse Furnace Power | 10 kW |
| Brand | Yanrui |
|---|---|
| Model | ONH-530 |
| Origin | Chongqing, China |
| Instrument Type | Oxygen-Nitrogen-Hydrogen Elemental Analyzer |
| Analysis Elements | O, N, H |
| Sample Types | Ferrous & non-ferrous metals, ceramics, superconductors, semiconductors, refractory materials (e.g., steel, iron, copper, zirconium, titanium, tantalum, niobium, rare earths, hard alloys) |
| Analysis Principle | Inert gas fusion coupled with infrared absorption (O, H) and thermal conductivity detection (N) |
| Analysis Range | Low-O: 0.0001–3.0 wt% |
| Optional high-O | 0.1–50.0 wt% |
| Low-N | 0.0001–3.0 wt% |
| Optional high-N | 0.1–60.0 wt% |
| H | 0.00001–0.50 wt% |
| Detection Limit | 0.1 ppm (O, N) |
| Precision | O/N: ±0.0001 wt% or RSD ≤ 1.0% |
| H | ±0.0002 wt% or RSD ≤ 2.0% |
| Analysis Time | < 180 s per sample |
| Pulse Electrode Furnace Power | 8.5 kW (max. 9 kW), operating current ≤ 1500 A, peak temperature > 3500 °C |
| Balance Resolution | 0.1 mg |
| Reagents | Magnesium perchlorate (H₂O trap), sodium hydroxide asbestos (CO₂ absorbent), copper oxide (CO → CO₂ converter) |
| Dimensions (W×D×H) | 700 × 770 × 820 mm |
| Net Weight | ~165 kg |
| Compliance | Designed to support GLP/GMP workflows |