| Brand | ExtraSolution |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PackPerm |
| Pricing | Available Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GBPI Y310 2.0 |
| Price | USD 54,500 (FOB Guangzhou) |
| Test Principle | Coulometric Oxygen Sensor Method |
| Standards Compliance | GB/T 19789, ASTM D3985, ASTM F2622, ASTM F1927, ASTM F1307, ISO 15105-2, DIN 53380-3, JIS K-7126-B, YBB 00082003 |
| Measurement Range | 0.05–1000 cm³/(m²·24 h) (up to 260,000 cm³/(m²·24 h) with auxiliary mask) |
| Resolution | 0.001 cm³/(m²·24 h) |
| Temperature Control Range | 15–45 °C |
| Temperature Stability | ±0.1 °C |
| Test Area | 50.24 cm² (customizable down to 0.785 cm²) |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 independent test chambers |
| Carrier Gas Pressure | ≥0.1 MPa |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power Consumption | 750 W |
| Electrical Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | Y310-3 |
| Price Range | USD 14,000 – 72,000 |
| Test Range | 0.02–16,500 cm³/(m²·24h) (film) |
| O₂ Detection Resolution | 0.001 cm³/(m²·24h) |
| Temperature Control | 15–45°C (5–50°C optional) |
| Humidity Control | 0%RH (dry), 30–90%RH, 100%RH |
| Test Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions (W×D×H) | 700×560×370 mm |
| Weight | 100 kg |
| Power | 750 W |
| Supply | AC 220 V, 50 Hz |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® 2/22 H |
| Detection Principle | Coulometric Sensor (ASTM D3985) |
| Compliance | ASTM D3985, ISO 18369-4:2017, GB/T 11417.7–2012 |
| Sensor Type | Absolute, Zero-Calibration Coulometric Sensor |
| Measurement Range | Ultra-Low to High OTR (O₂) |
| Application Focus | Rigid Gas Permeable (RGP) & Soft Hydrogel/Silicone Hydrogel Contact Lens Materials |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® 2/22 |
| Detection Principle | Coulometric (COULOX®) Sensor-Based OTR Measurement |
| Compliance | ASTM D3985, ISO 15105-2, FDA 21 CFR Part 11 Ready (with optional software package) |
| Test Chamber | Horizontal, Interchangeable Sealed Test Cell with TruSeal® Dual-Gasket Design |
| Sample Handling | Manual single-sample loading per cycle |
| Typical OTR Range | 0.005–10,000 cm³/m²·day·atm (dependent on cell configuration and film barrier level) |
| Sensor Type | Absolute coulometric oxygen sensor (zero-calibration required) |
| Data Output | Real-time OTR curve, permeation onset time, steady-state slope calculation |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® 2/28 H |
| Detection Range | 0.05–200 cm³/(m²·day) |
| Sensor Type | Patented Coulometric Coulox® Absolute Sensor |
| Test Chambers | 4 Independent Horizontal Dual-Membrane Cells |
| Compliance | ASTM D3985, ISO 15105-2, FDA 21 CFR Part 11 (with optional audit trail software) |
| Temperature Control | Automatic, ±0.1 °C stability |
| Flow Control | Precision Mass Flow Controllers |
| Sealing Method | TruSeal™ Nitrogen Purge Ring |
| Sample Throughput | Up to 4 specimens simultaneously |
| Detection Limit | 0.05 cm³/(m²·day) |
| Response Time | <60 seconds to 90% signal stabilization |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® 2/40 |
| Test Principle | Coulometric Oxygen Detection |
| Sample Type | Whole Packages & Films |
| Standards Compliance | ASTM D3985, ASTM F1927, ISO 15105-2, JIS K-7126, ASTM F1307, GB/T 31354-2014 |
| Temperature Range | 10–50 °C (±0.2 °C) |
| Humidity Range | 5–90 %RH (±4 %RH) |
| OTR Range (Containers, Air) | 0.00025–1.0 cc/pkg·day |
| Resolution (Containers) | 0.0001 cc/pkg·day |
| Repeatability | ±0.0001 cc/pkg·day |
| Test Duration | 30–60 min |
| Sensor Type | Absolute Coulometric Oxygen Sensor (Faraday-based, calibration-free) |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® 2/48 |
| Compliance | ASTM D3985 |
| Sensor Type | Coulometric (Coulox®) |
| Chamber Configuration | 8-chamber (4 conditioning + 4 testing, parallel operation) |
| Humidity & Flow Control | Automated RH and carrier gas flow in both conditioning and test chambers |
| Sealing Technology | TruSeal® integrated seal verification |
| Warranty | 4-year sensor warranty |
| Software | MOCON Permatran-W® v6.x with 21 CFR Part 11 compliance options |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | Ox-TRAN® 2/48 |
| Compliance | ASTM D3985 |
| Sensor Technology | Coulometric (Coulox®) |
| Test Chambers | 8 (4 conditioning + 4 testing, parallel operation) |
| Humidity & Flow Control | Automated in both conditioning and test chambers |
| Sealing System | TruSeal® integrated |
| Warranty | 4-year sensor warranty |
| Software | Touchscreen GUI with audit trail, user-level access control, and GLP-compliant reporting |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® Model 2/12 |
| Test Range (Film) | 0.5–144,000 cc/m²·day |
| Test Range (Container) | 0.0025–720 cc/pkg·day |
| Resolution (Film) | 0.05 cc/m²·day |
| Repeatability | ±0.25 cc/m²·day |
| Temperature Range | 5–50 °C |
| Humidity Range (Film) | 0–90 %RH (±3 %RH) |
| Dual Test Cells | 2 × 50 cm² |
| Sample Size (Film) | 10.8 cm × 10.8 cm |
| Container Capacity | Up to 3 L |
| Compliance | ASTM F2622, ASTM D3985 |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® Model 2/22 |
| Standards Compliance | ASTM D3985, ASTM F1927, ASTM F1307, ISO 15105-2, GB/T 19789-2005, GB/T 31354-2014, YBB00082003-2015 |
| Test Range (Film) | 0.0005–200 cm³/(m²·day) |
| Resolution | 0.0002 cm³/(m²·day) |
| Temperature Control | 10–40 °C (±0.2 °C) |
| Humidity Control | 0–90% RH (dual-side independent) |
| Test Chamber | Dual 50 cm² chambers (standard), optional 5.64 cm² |
| Sample Format | Flat films (10.8 × 10.8 cm) or packages (≤3 L) |
| Sensor | Coulometric (Coulox®), NIST-traceable, zero-calibration required |
| Automation | Fully automated gas flow, pressure, temperature, and humidity control |
| Sealing Technology | TruSeal™ nitrogen curtain sealing |
| Interface | Integrated touchscreen, USB, Ethernet, remote operation via PermNet® Lite |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | OX2/231 |
| Price Range | USD 28,000 – 42,500 |
| Measurement Principle | Coulometric Sensor (ISO 15105-2 Compliant) |
| Test Method | Isobaric Equal-Pressure Mode |
| Chambers | 3 Independent Testing Cells |
| Temperature Control Range | 5–95 °C |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control | 0%RH, 35–90%RH (±1%RH accuracy) |
| Film OTR Range | 0.01–6500 cm³/m²·d (standard), up to 63,000 cm³/m²·d (optional) |
| Container OTR Range | 0.0001–62 cm³/pkg·d |
| Film Resolution | 0.001 cm³/m²·d |
| Container Resolution | 0.00001 cm³/pkg·d |
| Test Area | 48 cm² |
| Sample Size (Film) | ≥150 mm × 94 mm or circular |
| Sample Size (Container) | ≤Φ120 mm × 400 mm (H) |
| Max. Thickness | 3 mm |
| Carrier Gas | 99.999% High-Purity N₂ |
| Flow Rate | 0–200 mL/min |
| Interface | 1/8″ Stainless Steel Tubing |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 730 × 590 × 350 mm |
| Net Weight | 56 kg |
| Standards Compliance | GB/T 19789, ASTM D3985, ASTM F2622, ASTM F1307, ASTM F1927, ISO 15105-2, JIS K7126-B, YBB 00082003 |
| Software | Embedded Win-based Control & Analysis Suite with Audit Trail, Multi-level User Access (5 tiers), Real-time Curve Logging (T, RH, Flow, OTR), Optional DSM Laboratory Data Management System Integration |
| Brand | Youyunpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YP-DK3 |
| Price | USD 2,500 (FOB) |