| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | POM |
| Instrument Type | Portable |
| Measurement Range | 0–10 ppm |
| LOD | 4 ppb |
| Response Time | 10 s |
| Zero Drift | 1.5 ppb |
| Resolution | 1 ppb |
| Detection Principle | UV Absorption at 254 nm |
| FEM Designation | EQOA-0815-227 |
| NIST-Traceable Calibration | Yes |
| Operating Temperature | 0–50 °C |
| Pressure Range | 150–1013 mbar |
| Data Storage Capacity | 8,192 records |
| Power | 7.4 V Li-ion battery (5–8 h) or AC adapter (100–240 VAC to 12 VDC) |
| Dimensions (with GPS) | 12.7 × 7.6 × 3.8 cm |
| Weight (with battery) | 450 g |
| Brand | 4FD |
|---|---|
| Origin | USA |
| Model | BT200 |
| Instrument Type | Online |
| Measurement Range | 0–1 ppmv to 0–20 vol.% |
| Detection Limit | 0.0001 ppmv (at 0–1 ppmv range) |
| Response Time (t95) | <30 s (low-concentration mode) |
| Zero Drift Compensation | Automatic zero-cleaning cycle |
| Resolution | 0.0001 ppmv |
| Analog Output | 4–20 mA or 0–10 V |
| Power Supply | DC 12 V, 1.5 A (AC 100–240 V, 50–60 Hz) |
| Operating Temperature | 0–40 °C |
| Operating Humidity | <90% RH (non-condensing) |
| UV Lamp Lifetime | 20,000 hours (50% output degradation) |
| Calibration Interval | 12 months |
| Accuracy | ±1% of reading or ±10% of full scale, whichever is greater (within validated range |
| Brand | AERODYNE |
|---|---|
| Origin | Beijing, China |
| Model | EcoCosm |
| Instrument Type | Online Fixed-Station System |
| Measurement Range | O₃: 0–200 nmol·mol⁻¹ (ppb) |
| CO₂ | 0–1000 ppm |
| Co-measured Gases | CO, CH₄, N₂O, NO, NO₂ |
| OTC Capacity | Up to 15 Open-Top Chambers (OTCs) |
| Control Resolution | < ±2 nmol·mol⁻¹ O₃ |
| Sampling Interval | Configurable (default 10 min) |
| Imaging Frequency | 1 image per OTC per hour |
| Compliance | Designed for GLP-aligned environmental exposure studies |
| Brand | AeroNose |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Portable |
| Measurement Range | 0.1 ppb – 100 ppm |
| Detection Limit | ±1% of reading @ 100 ppb – 100 ppm |
| Response Time | 40 sec @ 500 ppb |
| Zero Drift Compensation | Automatic dual-channel switching |
| Resolution | 1% of Full Scale (F.S.) |
| Analog Output Options | 4–20 mA / 0–1 VDC / 1–5 VDC (selectable) |
| Data Update Interval | 0.1 sec – 25,500 min (configurable) |
| Sampling Flow Rate | 1.0–1.5 L/min (integrated pump) |
| Operating Temperature | 0–40 °C |
| Power Supply | DC 12 V, 1.5 A max. |
| Weight | 1.5 kg (including ozone scrubber and particulate filter) |
| Communication Interface | USB (for real-time temperature, pressure, and concentration logging) |
| Alarm Outputs | LED indicators for particle filter status, light source health, ozone scrubber saturation, and calibration due date |
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Instrument Type | Portable |
| Measurement Range (Low) | 0–0.5 ppm |
| Detection Limit (Low) | 1 ppb |
| Response Time (Low) | < 95 s |
| Measurement Range (High) | 0–10.00 ppm |
| Resolution (High) | 0.01 ppm |
| Response Time (High) | < 35 s |
| Leakage Probe Range | 0–50.00 ppm (up to 100 ppm) |
| Resolution (Leak) | 0.01 ppm |
| Response Time (Leak) | < 10 s |
| Sensor Technology | GSS (Gas Sensitive Semiconductor) with Built-in Compensation Algorithm |
| Operating Environment | –5 to 50 °C, 5–95% RH (non-condensing) |
| Sampling Method | Active pump-assisted aspiration |
| Optional Multi-gas Modules | VOC, CO, NH₃ |
| Brand | API |
|---|---|
| Origin | USA |
| Model | T400 |
| Instrument Type | Fixed-mount |
| Measurement Range | 0–10 ppb (standard), optional dual-range 0–100 ppb / 0–10 ppm |
| LOD | <0.6 ppb |
| Response Time (T95) | <20 s |
| Zero Drift | <1.0 ppb/24 h |
| Span Drift | <1% of reading/7 days |
| Resolution | 0.1 ppb (0–50 ppb range) |
| Sample Flow Rate | 800 cm³/min ±10% |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Power Supply | 100–240 V AC, 50/60 Hz, 250 W |
| Dimensions (H×W×D) | 178 × 432 × 597 mm |
| Weight | 18 kg |
| Output Signals | 0–10 V, 0–5 V, 0–1 V, 0–100 mV, 0–20 mA, or 4–20 mA (isolated) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A-21ZX |
| Instrument Type | Fixed-Mount |
| Measurement Range | 0–10 ppm |
| Detection Limit | 0.01 ppm (resolution) |
| Response Time | <60 seconds (T90) |
| Zero Drift | <±0.02 ppm/week |
| Resolution | 0.01 ppm |
| Dimensions | 110 × 220 × 64 mm (L×W×H) |
| Weight | 570 g |
| Power Supply | 12–24 VDC, 500 mA |
| Operating Temperature | 0–40 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | AQMS-300 |
| Instrument Type | Online Fixed-Mount Analyzer |
| Detection Principle | UV Photometry (254 nm) |
| Compliance | Designed for EPA EQOA-01, ISO 13964, and EN 14625 compliance frameworks |
| Output Interfaces | RS232, RS485, Ethernet, 4–20 mA analog output |
| Calibration | Remote automatic zero/span calibration with programmable schedule |
| Lamp Monitoring | Integrated mercury lamp intensity self-diagnostic with lifetime estimation |
| Flow Protection | Auto-shutdown at sub-threshold sample flow rate |
| Security | Role-based remote access control with firmware upgrade authorization |
| Enclosure Rating | IP54 (indoor industrial use) |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Online Continuous Emission Monitor |
| Detection Principle | Dual-Detector Gas Chromatography (GC-PID/GC-FID) |
| Sample Introduction | Stepper Motor-Driven Piston Sampling System with Temperature/Pressure Compensation |
| Preconcentration | Integrated Tenax TA or Cryo-Focused Trap with Thermal Desorption |
| Separation Architecture | Two-Dimensional GC (2D-GC) with Primary Pre-Separation Column and Analytical Capillary Column |
| Detector Configuration | Photoionization Detector (PID) + Flame Ionization Detector (FID) |
| Data Acquisition & Control | Embedded Industrial PC with Real-Time OS |
| Communication Interfaces | Ethernet, RS-232 (COM), USB, 4–20 mA Analog Output, Digital I/O |
| Compliance Support | Designed for EPA TO-15 / TO-17 alignment, compatible with ISO 8573-6 (hydrocarbon analysis in ambient air), supports audit-ready data logging per GLP/GMP principles |
| Brand | Jilin University Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GDYK-601S |
| Price | Upon Request |
| Detection Limit | 0.01 mg/m³ |
| Measurement Range | 0.0–1.0 mg/m³ |
| Accuracy | ±5% |
| Method Compliance | GB/T 18204.27–2000 |
| Analysis Time | ≤10 minutes |
| Sample Handling | Integrated pre-treatment module + single-use reagent kit |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Measurement Range | 0–500 ppb (expandable) |
| Limit of Detection (LOD) | ≤1 ppb |
| Response Time (T90) | ≤20 s |
| Zero Drift | ±2 ppb max over 24 h |
| Resolution | ≤1% of full scale |
| Display | 5-inch capacitive touchscreen |
| Positioning | Integrated BeiDou/GPS dual-mode module |
| Power Supply | Rechargeable high-capacity Li-ion battery |
| Data Connectivity | Wi-Fi, 4G LTE, Bluetooth |
| Onboard Storage | 8 GB internal flash memory |
| Filter Maintenance | Replaceable particulate filter (days), hydrophobic ozone scrubber (6 months) |
| Compliance | GB/T 18883–2022, HJ 590–2010, JJG 1077–2012, HJ 654–2013 |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LH-3S |
| Instrument Type | Portable |
| Measurement Ranges | 0–100 mg/L and 0–200 mg/L (user-selectable) |
| Limit of Detection | 0.1 mg/L |
| Response Time | ≤1 s |
| Zero Drift | ±0.1 mg/L (24 h) |
| Resolution | 0.1 mg/L |
| Principle | Dual-Wavelength UV Absorption (254 nm & 365 nm) |
| Dimensions | 120 × 260 × 206 mm |
| Brand | Lontec |
|---|---|
| Model | LT-200B |
| Measurement Principle | Dual-beam UV absorption at 254 nm (Lambert-Beer Law) |
| Measurement Range | 0–50 / 0–200 / 0–300 mg/L (customizable) |
| Response Time | <5 s |
| Zero Drift | <±0.5% F.S. |
| Resolution | 0.1 mg/L |
| Accuracy | ±2% of reading |
| Temperature Compensation | Yes |
| Pressure Compensation | Yes |
| Light Source Compensation | Yes |
| Output Signals | Isolated 0–10 V and/or 4–20 mA (selectable) |
| Display | LCD screen |
| Sample Inlet Pressure | <0.15 MPa |
| Operating Ambient Temperature | –20 to +50 °C |
| Dimensions | 400 × 300 × 155 mm |
| Power Supply | 220 VAC, 50 Hz |
| Weight | 11 kg |
| Lamp Lifetime | ~2 years (imported low-pressure Hg lamp, 254 nm) |
| Sampling Method | Positive-pressure sampling |
| Compliance | Designed for continuous industrial process monitoring per ISO 14644, EPA Method O3-UV, and aligned with GLP data integrity expectations |
| Brand | Sabio |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Model 2030 |
| Price | Upon Request |
| Measurement Principle | UV Absorption at 254 nm (Beer–Lambert Law) |
| Range Options | 0–100 / 0–200 / 0–500 ppb or 0–1 / 0–2 ppm |
| Detection Limit | 1 ppb |
| Zero Noise | 0.6 ppb RMS |
| Zero Drift | <1.0 ppb/24 hr, <2.0 ppb/7 days |
| Span Drift | <1% per month |
| Response Time | 20 s (10 s delay) |
| Accuracy | ±1 ppb |
| Linearity | ±1% of full scale |
| Sample Flow Rate | 1 L/min |
| Operating Temperature | 5–45 °C |
| Power Supply | 98–132 VAC / 196–264 VAC, 50/60 Hz |
| Analog Outputs | Four independent, scalable (0.1 V / 1 V / 2 V / 5 V / 10 V) |
| Digital Interfaces | USB, RS-232/RS-485 (DB-9) |
| Display | Color LCD with touchscreen, front-panel keys, external keyboard/mouse support |
| Data Storage | Internal logging with timestamped records |
| Built-in Ozone Generator | 0.05–1.5 ppm @ 5 SLM, ±2% of setpoint or ±3 ppb @ 5 SLM |
| Auto Zero Compensation | Yes |
| Temperature & Pressure Compensation | Yes |
| Dimensions | 15.6 cm H × 36.4 cm W × 31.6 cm D |
| Weight | 9.1 kg |