Particle Dispersion Analyzer
Filter
Showing all 8 results
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | BeScan Lab |
| Pricing | Upon Request |
| Brand | Formulaction |
|---|---|
| Origin | France |
| Model | Turbiscan AGS |
| Particle Size Range | 0.05–1000 µm |
| Concentration Range | up to 95% v/v |
| Temperature Control | 25–60 °C (±0.5 °C) |
| Sample Capacity | 54 positions (3 × 18-well thermostated modules) |
| Scan Resolution | 40 µm along 55 mm height |
| Scan Interval | as low as 20 s per scan |
| Light Source | Pulsed NIR LED (880 nm) |
| Detectors | Synchronized transmission and backscattering photodiodes |
| Compliance | ASTM D7809, ISO 13321, USP <729>, GLP-ready data audit trail |
| Brand | Labman |
|---|---|
| Origin | Germany |
| Model | TIDAS |
| Measurement Principle | Hegman-type grind gauge imaging analysis |
| Sample Application | Liquid dispersions (paints, inks, coatings, slurries) |
| Plate Range Compatibility | 0–15 µm, 0–25 µm, 0–50 µm, 100 µm, 250 µm (custom plates available) |
| Imaging Resolution | High-definition digital capture |
| Analysis Time | ≤1 s per image |
| Total Cycle Time | ~15 s (including auto-coating) |
| Software Platform | Windows 7/8/10 native |
| Data Output | Histograms, particle size distribution profiles, pass/fail grading per ISO 1524 or ASTM D1316 |
| Compliance Support | Audit-trail ready, GLP/GMP-compatible metadata logging |
| Interface | USB 2.0 |
| System Lifespan | ≥12 years (field-validated) |
| Brand | LUM GmbH |
|---|---|
| Origin | Germany |
| Model | LUMiSizer 65X |
| Measurement Principle | STEP-Technology (Spatial and Temporal Extinction Profiles) |
| Sample Throughput | 12 positions simultaneously |
| Temperature Control Range | 4 °C to 60 °C (±1 K) |
| Particle Size Range (ISO 13318-2) | 20 nm – 100 µm |
| Stability & Sedimentation Velocity Range | 10 nm – 1000 µm |
| Concentration Range | 0.00015 % – 90 % w/w |
| Density Range | up to 22 g/cm³ |
| Viscosity Range | 0.8 – 10⁸ mPa·s |
| Acceleration Force | 6 × g to 2300 × g |
| Optical Wavelength Options | 470 nm (blue) and 865 nm (NIR) |
| Sample Volume | 0.05 – 2.0 mL |
| Compliance | ISO/TR 13097, ISO 13318-2, FDA 21 CFR Part 11 (via SEPView software audit trail), GLP/GMP-ready |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Model | LUMiFuge® |
| Measurement Principle | Spatially Resolved Extinction Profile Analysis under Controlled Centrifugal Force |
| Sample Throughput | Up to 8 samples per run |
| Rotor Speed Range | 0–4,000 rpm (variable, programmable) |
| Detection Method | Polydisperse near-infrared (NIR) light transmission at 870 nm |
| Spatial Resolution | 10 µm per data point across 5 cm sample path |
| Data Acquisition Frequency | Up to 1 scan/s (adjustable) |
| Temperature Control | 5–40 °C (±0.5 °C) |
| Sample Volume per Cell | 0.1–2.0 mL |
| Compliance | ASTM D7713-19 (Standard Practice for Stability Evaluation of Dispersions by Centrifugation), ISO 13321 (Particle Size Analysis – Photon Correlation Spectroscopy), GLP-ready with audit trail and user access control |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Model | LUMiFuge |
| Centrifugal Acceleration | up to 1200 × g |
| Sample Capacity | 8 positions |
| Temperature Control Range | 4–60 °C (in three programmable zones) |
| Sample Volume | 0.1–2 mL |
| Particle Size Range | 0.05–1000 µm |
| Concentration Range | 1–90 vol% |
| Viscosity Range | 0.8–10⁸ mPa·s |
| Density Range | 0.01–10 g/cm³ |
| Separation Velocity Resolution | 0.01–1000 µm/s |
| Compliance | ISO 13318-2 |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Model | LUMiReader® PSA |
| Measurement Principle | Spatially Resolved Transmission Analysis (SRTA) with Multi-Wavelength Optical Detection |
| Compliance | Designed for GLP/GMP environments |
| Brand | Formulaction |
|---|---|
| Origin | France |
| Model | TURBISCAN DNS |
| Measurement Principle | Static Multiple Light Scattering (SMLS) |
| Detection Modes | Transmittance (T) and Backscattering (BS) |
| Sample Volume | 1.5–30 mL |
| Concentration Range | 0.0001–95% v/v |
| Particle Size Range | 10 nm–1 mm |
| Spatial Resolution | Vertical scanning with high-frequency acquisition |
| In-situ Options | T-MIX (stirred mode), T-LOOP (circulation mode) |
| Output Metric | Turbiscan Stability Index (TSI) |