Penetration Tester
Filter
Showing all 5 results
| Brand | MITONG (Shanghai Mitong Instrument Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | SYD-2801C-1 |
| Penetration Range | 0–700 dmm |
| Temperature Control Range | 0–65 °C |
| Temperature Stability | ±0.1 °C at 25 °C |
| Penetration Resolution | 0.01 mm |
| Penetration Accuracy | ±1 dmm |
| Standard Needle | 50 mm length, 2.5 g ±0.05 g |
| Standard Cone | 102.5 g ±0.05 g |
| Timing Options | 5, 8, 10, 12, 30, 60 s (±0.1 s tolerance) |
| Bath Type | Rigid borosilicate glass cylinder with magnetic stirrer |
| Power Supply | AC 220 V ±10%, 50 Hz, ≤300 W |
| Brand | MITONG (Shanghai Mitong Instrument Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | SYP-0983 |
| Penetration Measurement Range | 0–700 dmm |
| Temperature Control Range | 0–65 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Penetration Resolution | 0.01 mm |
| Maximum Penetration Depth | ±1 dmm |
| Standard Cone (No. 1) | (102.5 ± 0.05) g |
| Cone Rod Mass | (47.5 ± 0.05) g |
| Timing Options | 5, 8, 10, 12, 30, 60 s (±0.1 s accuracy) |
| Power Supply | AC 220 V ±10 %, 50 Hz, ≤300 W |
| Dimensions (L×W×H) | 280 × 350 × 700 mm |
| Brand | NORMALAB |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NPN Tech |
| Price | Upon Request |
| Temperature Control Range | -10 to 150 °C |
| Temperature Control Accuracy | ±0.05 °C |
| Penetration Resolution | 0.01 mm |
| Maximum Penetration Depth | 75 mm |
| Brand | Qigao Instruments (SHQIGAO) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HSY-4509K |
| Pricing | Upon Request |
| Temperature Control Range | 20.00 °C to 50.00 °C |
| Temperature Control Accuracy | ≤ ±0.1 °C |
| Penetration Measurement Accuracy | ≤ ±0.1 mm |
| Maximum Penetration Depth | 660 penetration units (0.1 mm increments) |
| Brand | Shengtai Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SD-2801A |
| Temperature Control Range | Constant 25 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Penetration Measurement Accuracy | ±1 penetration unit |
| Maximum Penetration Depth | 700 penetration units |
| Penetration Time Control Accuracy | ±0.1 s |
| Resolution | 0.01 mm |
| Standard Cone Mass | 102.5 ± 0.05 g |
| Standard Needle Mass | 2.5 ± 0.05 g |
| Sample Cup Dimensions | Ø100 mm × ≥65 mm |
| Power Consumption | 80 W |
| Dimensions (L×W×H) | 340 × 282 × 515 mm |
| Net Weight | 11 kg |