Petroleum Distillation Apparatus
Filter
Showing all 19 results
| Brand | AD Systems |
|---|---|
| Origin | France |
| Model | VD10 |
| Operating Pressure | Atmospheric |
| Temperature Range | 0–450 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Temperature Range | 0–65 °C |
| Distillation Rate | 2–10 mL/min |
| Volume Detection Range | 0–100 mL |
| Volume Resolution | 0.1 mL |
| Brand | Benteng |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BT-2001 |
| Price Range | USD 7,000–14,000 (FOB) |
| Operating Pressure | Atmospheric |
| Temperature Measurement Range | 0–450 °C |
| Temperature Accuracy | ±0.2 °C |
| Cold Bath Temperature Range | 0–80 °C |
| Distillation Rate | 2–10 mL/min (programmable & auto-regulated) |
| Volume Detection Range | 0–101 mL |
| Volume Resolution | 0.1 mL |
| Atmospheric Pressure Sensing Range | 300–1100 hPa |
| Pressure Accuracy | ±3 hPa |
| Cold Trap Temperature Range | 0–60 °C |
| Cold Trap Control Accuracy | ±0.3 °C |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYD-6536A |
| Test Pressure | Atmospheric (0.1 MPa nominal) |
| Temperature Control Range | (Ambient + 10)°C to 60°C (adjustable in 0.1°C increments) |
| Temperature Accuracy | ±0.5°C |
| Condensate Volume Measurement | 100 mL graduated cylinder (1 mL graduation) |
| Power Supply | AC (220 ± 10%) V, 50 Hz |
| Dual-Sample Capability | Yes (independent dual-channel operation) |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | SYD-9168A |
| Test Mode | Vacuum (Reduced Pressure) |
| Temperature Range | 30 °C to 80 °C ±3 °C (for condenser cooling bath) |
| Temperature Accuracy | ±0.5 °C |
| Absolute Pressure Control Range | 2, 5, 10, 20, 50 mmHg |
| Pressure Measurement Range | 2.00–170.00 mmHg ±0.01 mmHg |
| Pressure Control Precision | <0.01 mmHg (at residual pressure <7.5 mmHg) |
| Cold Trap Temperature | ≤−40 °C (Peltier-cooled) |
| Heating Power | 0–500 W adjustable |
| Total Power Consumption | ≤1800 W |
| Compliance | GB/T 9168 |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MINIDIS ADXpert |
| Test Pressure | Atmospheric (0 kPa gauge) |
| Temperature Range | 0–400 °C (32–752 °F) |
| Temperature Accuracy | ±0.1 °C |
| Distillation Time (Gasoline) | 15 min |
| Sample Volume | 6 mL |
| Residue Measurement | Integrated analytical balance (±0.003 g) |
| Predefined Methods | 10 (ASTM D86 Group 0–4, ASTM D7344, ISO 3045, IP 123) |
| Cleaning Volume per Cycle | 4 mL (acetone) |
| Dimensions (W×H×D) | 200 × 320 × 220 mm |
| Weight | 13 kg |
| Power Supply | 100–240 V AC, 50/60 Hz, 150 W or 12 V DC (optional vehicle battery) |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MiniDIS ADXpert |
| Temperature Range | 0–400 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Range | 0–50 °C |
| Distillation Rate | 0–12 mL/min |
| Volume Detection Range | 0–110 mL |
| Volume Resolution | 6 µL |
| Sample Volume | 6 mL |
| Residue Measurement Accuracy | ±0.003 g |
| Dimensions | 200 × 320 × 220 mm |
| Weight | 13 kg |
| Power Supply | 100–240 V AC, 50/60 Hz, 150 W |
| Optional DC Input | 12 V / 10 A |
| Predefined Methods | 10 (ASTM D86 Groups 0–4) |
| Data Storage Capacity | 75 test results |
| Compliance | ASTM D86, ASTM D7344, ISO 3405, IP 123, DIN 51751 |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MiniDIS |
| Temperature Range | 0–400 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Temperature Range | −20 °C to +60 °C |
| Distillation Rate | 1–11 mL/min |
| Volume Detection Range | 0.1 mL |
| Volume Resolution | 0.1 mL |
| Sample Volume | 6 mL |
| Residue Measurement Accuracy | ±0.003 g |
| Dimensions (W×H×D) | 200×320×220 mm |
| Weight | 13 kg |
| Power Supply | 100–240 V AC, 50/60 Hz, 150 W |
| Optional DC Input | 12 V/10 A |
| Compliance | ASTM D7344, ASTM D86, ISO 3405, IP 123, DIN 51751 (Groups 0–4) |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MiniVAP VPSH+ Crude Oil Package |
| Application | Crude oil vapor pressure (RVP/TVPR) determination per ASTM D323, D6377, and ISO 3014 |
| Sample Handling | Mobile piston cylinder sampling system with pressurized transfer and mechanical agitation |
| Automation | Fully automated measurement cycle including purge, equilibration, pressure stabilization, and cleaning |
| Compliance | Designed to meet ASTM D6377 (TVPR), ASTM D323 (RVP), ISO 3014, and EN 13016-1 requirements |
| Operating Temperature | 37.8 °C (100 °F) controlled bath |
| Pressure Range | 0–200 kPa (0–29 psi) absolute |
| Resolution | 0.1 kPa |
| Repeatability | ≤0.5 kPa (per ASTM D6377) |
| Brand | NORMAG |
|---|---|
| Origin | Germany |
| Model | 50L Reactive Distillation System |
| Configuration | Integrated vacuum-rated reactor vessel, packed/tray distillation column, reflux separator, fraction receivers, programmable temperature & vacuum control unit, corrosion-resistant fluid handling system |
| Compliance | Designed per DIN EN ISO 9001 manufacturing standards |
| Control Architecture | PLC-based with HMI touchscreen interface and Ethernet-enabled data logging |
| Brand | NORMAG |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Normag |
| Pricing | Upon Request |
| Brand | NORMAG |
|---|---|
| Origin | Germany |
| Model | DSV80 |
| Operating Pressure Range | 760 mbar to 10⁻³ mbar |
| Max. Heating Temperature | 250 °C |
| Feed Rate | 0.3–1 kg/h |
| Evaporator Type | Thin-Film & Falling-Film Configurable |
| Vacuum Compatibility | High-vacuum (≤10⁻³ mbar) |
| Application Scope | Thermally labile, high-viscosity, and heat-sensitive compounds |
| Brand | NORMAG |
|---|---|
| Origin | Germany |
| Model | Normag Micro SBC-100 |
| Theoretical Plates (at 1 atm, total reflux) | 50 |
| Effective Column Height | 100 cm |
| Column Inner Diameter | DN6 (≈6 mm) |
| Brand | NORMAG |
|---|---|
| Origin | Germany |
| Model | Normag |
| Operating Pressure | Atmospheric and Vacuum (up to 0.1 mbar) |
| Temperature Range | Up to 200 °C |
| Reflux Ratio Control | Manual and Automated |
| Condensate Flow Monitoring | Yes, with automatic shutoff safety interlock |
| Feed/Collection | Continuous inlet and outlet |
| Construction Materials | Borosilicate glass (DIN ISO 3585) and PTFE-sealed piston valves |
| Joint Standards | NS-ground, spherical ground, and flange connections |
| Safety Certification | Non-explosion-proof (suitable for standard laboratory environments per EN 61000-6-3 and EN 61000-6-4) |
| Brand | NORMAG |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Normag |
| Pricing | Available Upon Request |
| Brand | NORMAG |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Normag |
| Pricing | Upon Request |
| Brand | Pilodist |
|---|---|
| Origin | Germany |
| Model | TF 650 |
| Operating Temperature Range | up to 250 °C |
| Operating Pressure Range | 0.1–10 mbar (absolute) |
| Feed Rate | 0.5–10 L/h |
| Evaporation Area | 6.5 dm² |
| Construction Material | High-grade stainless steel (SS 316L standard) |
| Dimensions (W × H × D) | 1.20 × 1.80 × 0.60 m |
| Ultimate Vacuum Capability | ≤0.001 mbar (with compatible vacuum system) |
| Brand | SPECTRA INVENT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HX-DR1505A |
| Pressure Mode | Vacuum (Reduced-Pressure) |
| Temperature Range (Distillation) | Ambient to 400 °C |
| Cold Bath Temperature Range | 5–80 °C |
| Compliance | ASTM D1160, ASTM D2892, ASTM D5236, ISO 3405, GB/T 6536 (Vacuum Mode Adaptation), IP 123 |
| Brand | ORBIS BV |
|---|---|
| Origin | Netherlands |
| Model | STARDist micro |
| Sample Volume | 10 mL ± 0.3 mL |
| Analysis Time | < 10 minutes |
| Temperature Range | 0–500 °C |
| Temperature Resolution | 0.1 °C |
| Heating Power | 140 W |
| Power Supply | AC 100–240 V, 50/60 Hz, 300 W |
| Flash Point Prediction | Closed-cup flash point estimation for diesel and kerosene |
| Compliance | ASTM D7345, EN 17306, IP 596 (directly correlated to ASTM D86, ISO 3405, IP 123) |
| Operating System | Windows-based with capacitive touchscreen and stylus support |
| Form Factor | Benchtop, space-optimized design for mobile or constrained laboratories |
| Brand | Xuxin Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | ST-1572 |
| Price Range | USD 1,400–4,200 (FOB) |
| Temperature Range | Ambient to 400 °C |
| Temperature Accuracy | ±0.5 °C |
| Condenser Bath Temperature Range | Ambient to 60 °C |
| Distillation Rate | 1–5 mL/min |
| Volume Measurement Range | 0–125 mL |
| Volume Resolution | 0.1 mL |
| Heating Power | 1000 W (continuously adjustable) |
| Total Power Consumption | ≤1700 W |
| Condenser Material | Stainless Steel |
| Distillation Flask | 125 mL borosilicate glass (≥500 °C thermal resistance) |
| Graduated Cylinder Options | 10 mL and 100 mL |
| Cooling Method | Water-cooled |
| Input Voltage | AC 220 V ±10%, 50 Hz ±10% |
| Operating Environment | 5–45 °C, 10–80% RH |