| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PHBJ-260 |
| Instrument Type | Portable |
| Parameter Type | Single-Parameter (pH only) |
| Measurement Range | −2.00 to 20.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Standards | NIST-traceable Chinese national buffer solutions (pH 4.01, 6.86, 7.00, 9.18, 10.01) |
| Temperature Compensation | Automatic and Manual |
| Display | Backlit LCD (adjustable blue backlight) |
| Data Storage | Internal memory for calibration records and measurement logs |
| Connectivity | RS-232 serial interface (compatible with TP-16 printer and REX data acquisition software) |
| Protection Rating | IP65 |
| Power Supply | Battery-operated with low-battery indicator and auto-power-off function |
| Electrode Compatibility | Standard BNC connector |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | PHBJ-260 |
| Instrument Type | Portable |
| Parameter Types | Multi-parameter (pH, mV, Temperature) |
| pH Resolution | 0.01 pH |
| pH Range | –2.00 to 20.00 pH |
| Accuracy | ±0.01 pH |
| mV Range | –2000.0 to 2000.0 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1% FS or ±0.3 mV |
| Temperature Range | –5.0 to 110.0 °C (23.0 to 230.0 °F) |
| Temp. Resolution | 0.1 °C/°F |
| Temp. Accuracy | ±0.2 °C |
| Calibration Standards | GB, DIN, NIST |
| Calibration Points | 1–5-point pH calibration |
| Data Storage Capacity | 500 datasets |
| Protection Rating | IP65 |
| Power Supply | Rechargeable Li-ion battery (DC5V input via AC adapter, USB-compatible charging) |
| Dimensions | 80 × 255 × 35 mm |
| Weight | 0.4 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | PHBJ-260F |
| Price Range | USD 420–690 |
| Instrument Type | Portable |
| Parameter Types | Multi-parameter |
| pH Accuracy | ±0.01 pH |
| pH Measurement Range | −2.00 to 20.00 pH |
| pH Resolution | 0.01 pH |
| mV Range | −2000.0 to +2000.0 mV |
| mV Resolution | 0.1 mV |
| Temperature Range | −5.0 to 110.0 °C (23.0 to 230.0 °F) |
| Temperature Resolution | 0.1 °C/°F |
| Temperature Accuracy | ±0.2 °C |
| Calibration Standards Supported | GB, DIN, NIST |
| IP Rating | IP65 |
| Data Storage Capacity | 1000 datasets |
| Power Source | Rechargeable Li-ion battery (DC5V input via AC adapter or USB power bank) |
| Dimensions | 90 × 255 × 40 mm |
| Weight | 0.5 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | PHBJ-261L |
| Instrument Type | Portable |
| Parameter Type | Single-parameter (pH/mV/°C) |
| Measurement Range | –2.000 to 20.000 pH |
| Resolution | 0.001 pH |
| Accuracy | ±0.002 pH |
| Calibration Standards Supported | GB, DIN, NIST, USA, MERK, JIS |
| Temperature Compensation | Automatic and Manual |
| Calibration Points | Up to 8-point pH, 1-point ORP |
| Data Storage Capacity | 1,000 datasets |
| IP Rating | IP65 |
| Display | Color TFT Touchscreen |
| Connectivity | USB, Bluetooth 5.0, U-disk interface, Barcode scanner compatible |
| Power | Rechargeable Li-ion battery with PC/mobile power bank charging support |
| Compliance | GLP-compliant data logging with audit trail, LIMS-ready |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | PHBJ-261L |
| Instrument Type | Portable |
| Parameter Types | Multi-parameter |
| pH Measurement Accuracy | ±0.002 pH |
| pH Range | −2.000 to 20.000 pH |
| pH Resolution | 0.001 pH |
| mV Range | −2000.00 to 2000.00 mV |
| mV Resolution | 0.01 mV |
| Temperature Range | −10.0 to 135.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Calibration Standards Supported | GB, DIN, NIST, USA, MERCK, JIS |
| IP Rating | IP65 |
| Battery | Rechargeable Li-ion |
| Dimensions (L×W×H) | 90 × 255 × 40 mm |
| Weight | 0.5 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | PHS-25 |
| Price Range | USD 70–140 |
| Instrument Type | Benchtop |
| Parameter Types | Dual (pH and mV) |
| pH Accuracy | ±0.05 pH |
| pH Range | 0.00–14.00 pH |
| pH Resolution | 0.01 pH |
| mV Range | −1400 to +1400 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±1% FS |
| Temperature Compensation | Manual |
| Calibration Buffers | GB Standard Solutions at pH 4.00, 6.86, and 9.18 |
| Calibration Points | 1–2 point |
| Display | LCD with stability indicator |
| Enclosure Rating | IP54 |
| Power Supply | AC 100–240 V input, DC 20 V / 1500 mA output |
| Dimensions (L×W×H) | 200 × 160 × 63 mm |
| Weight | 0.6 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Benchtop |
| Parameter Type | Dual (pH/mV) |
| pH Measurement Range | 0.00–14.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.01 pH |
| mV Range | −1400 to +1400 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±0.1% FS |
| Input Impedance | ≥1×10¹² Ω |
| Temperature Compensation | Manual, 0.0–60.0 °C |
| Calibration Options | 1–2 point |
| Display | 6-inch HD LCD |
| IP Rating | IP54 |
| Dimensions | 290 × 210 × 95 mm |
| Weight | 1.5 kg |
| Power Supply | AC 100–240 V adapter |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PHS-2F |
| Price Range | USD 140–280 |
| Instrument Type | Benchtop |
| Parameter Types | Dual (pH + mV) |
| pH Accuracy | ±0.01 pH |
| pH Range | 0.00–14.00 pH |
| pH Resolution | 0.01 pH |
| mV Range | −1800 to +1800 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±0.1% FS |
| Temperature Compensation | Manual |
| Calibration Standards | GB Standard Buffers (pH 4.00, 6.86, 9.18) |
| Calibration Points | 1–2 point |
| Display | High-contrast LCD with stability indicator |
| Enclosure Rating | IP54 |
| Power Supply | AC/DC adapter (Input: 100–240 VAC, Output: 20 VDC / 1500 mA) |
| Dimensions (L×W×H) | 200 × 160 × 63 mm |
| Weight | 0.6 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Benchtop |
| Measurement Mode | Multi-parameter |
| pH Range | –2.00 to 18.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Points | 1–3 point manual calibration |
| Buffer Recognition | Automatic identification of GB standard buffers (pH 4.00, 6.86, 9.18) |
| Temperature Compensation | Manual |
| Data Storage | 50 measurement sets |
| Display | High-definition LCD |
| Protection Rating | IP54 |
| Included Accessories | Composite pH electrode, electrode stand, dust cover, and powdered buffer kits |
| Power Management | Auto-off, power-loss data retention, factory reset |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | PHS-3C |
| Instrument Type | Benchtop |
| Parameter Type | Dual-parameter (pH/mV) |
| pH Accuracy | ±0.01 pH |
| pH Range | –2.00 to 18.00 pH |
| Resolution | 0.01 pH |
| mV Range | –1999 to +1999 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±0.1% FS |
| Temperature Compensation | Manual |
| Calibration Points | 1–3 point pH calibration |
| Buffer Recognition | Automatic identification of GB standard buffers (pH 4.00, 6.86, 9.18) |
| Data Storage | 50 measurement sets |
| Display | LCD with backlight |
| Protection Rating | IP54 |
| Power Supply | AC 100–240 V input, DC 20 V / 1500 mA output |
| Dimensions (W×D×H) | 242 × 195 × 68 mm |
| Weight | 0.9 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | PHS-3E |
| Price Range | USD 280–420 |
| Instrument Type | Benchtop |
| Parameter Types | Multi-parameter (pH, mV, Temperature) |
| pH Accuracy | ±0.01 pH |
| pH Measurement Range | −2.00 to +18.00 pH |
| pH Resolution | 0.01 pH |
| mV Range | −1999 to +1999 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±0.1% FS |
| Temperature Range | −5.0 to 110.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Calibration Standards | GB Standard Buffers at pH 4.00, 6.86, and 9.18 |
| Calibration Points | 1–3-point automatic buffer recognition |
| Data Storage | 50 measurement sets |
| Protection Rating | IP54 |
| Power Supply | AC 100–240 V input, DC 20 V / 1500 mA output |
| Dimensions | 242 × 195 × 68 mm |
| Weight | 0.9 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PHS-3G |
| Price Range | USD 420 – 690 |
| Instrument Type | Benchtop |
| Parameter Types | Dual (pH and mV) |
| Measurement Accuracy | ±0.01 pH |
| pH Range | −2.00 to 19.99 pH |
| mV Range | −1999 to +1999 mV |
| pH Resolution | 0.01 pH |
| mV Resolution | 1 mV |
| Accuracy | ±0.01 pH, ±0.1% FS (mV) |
| Calibration Buffers | pH 4.00, 6.86, and 9.18 standard solutions |
| Temperature Compensation | Manual, 0.0–60.0 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Dimensions (W×D×H) | 210 × 310 × 95 mm |
| Weight | 2 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Benchtop |
| Parameter Types | Multi-parameter (pH, mV, Temperature) |
| Measurement Range | (−2.00 to 20.00) pH |
| Resolution | 0.01 pH (selectable to 0.1 pH) |
| Accuracy | ±0.01 pH |
| Temperature Compensation | Automatic and Manual |
| Calibration Points | 1–5-point pH calibration |
| Buffer Recognition | Auto-identification of GB, DIN, and NIST standard buffer sets |
| Data Storage Capacity | 500 measurement records |
| Compliance | GLP-compliant data management |
| Connectivity | RS-232 (for serial printers), USB (for PC communication) |
| Protection Rating | IP54 |
| Standard Accessories | Tri-combination pH electrode, electrode stand, dust cover, calibration buffer solutions |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Model | PHSJ-3F |
| Price Range | USD 420–690 |
| Instrument Type | Benchtop |
| Parameter Types | Multi-parameter (pH, mV, Temperature) |
| Measurement Accuracy | ±0.01 pH |
| pH Range | (−2.00 to 20.00) pH |
| Resolution | 0.01 pH |
| mV Range | (−2000.0 to 2000.0) mV |
| mV Resolution | 0.1 mV |
| Temperature Range | (−5.0 to 110.0) °C / (23.0 to 230.0) °F |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| Temperature Accuracy | ±0.2 °C |
| Calibration Standards Supported | GB, DIN, NIST |
| IP Rating | IP54 |
| Data Storage Capacity | 500 datasets |
| Interface | RS-232, USB |
| Power Supply | AC 100–240 V input, DC 9 V output |
| Dimensions (L×W×H) | 242 × 195 × 68 mm |
| Weight | 0.9 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PHSJ-4F |
| Price Range | USD 420–690 |
| Instrument Type | Benchtop |
| Parameter Type | Single-Parameter (pH/mV/Temp) |
| Measurement Accuracy | ±0.002 pH |
| pH Range | −2.000 to 20.000 pH |
| Resolution | 0.001 pH / 0.01 mV / 0.1 °C |
| Temperature Compensation | Automatic & Manual |
| Calibration Points | 1–5-point pH calibration |
| Buffer Recognition | GB, DIN, NIST, USA, MERK standard buffer sets |
| IP Rating | IP54 |
| Data Storage | 500 measurement records |
| Interface | RS-232 (printer), USB (PC connectivity) |
| Compliance | GLP-compliant data management |
| Power Supply | AC 100–240 V input, DC 9 V output |
| Dimensions (L×W×H) | 242 × 195 × 68 mm |
| Weight | 0.9 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PHSJ-5T |
| Price Range | USD 700–1,400 |
| Instrument Type | Benchtop |
| Parameter Type | Single-Parameter (pH/mV/ORP/Temperature) |
| Measurement Accuracy | ±0.002 pH |
| pH Range | −2.000 to 20.000 pH |
| Resolution | 0.001 pH / 0.01 mV / 0.1 °C |
| Calibration Standard | NIST-traceable buffers |
| IP Rating | IP54 |
| Compliance | GLP, GMP-ready, FDA 21 CFR Part 11-compatible data management |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Benchtop |
| Parameter Types | pH, mV, Temperature |
| Measurement Range | pH: –2.000 to 20.000 |
| mV | –2000.00 to 2000.00 mV |
| Resolution | 0.001 pH / 0.01 mV |
| Accuracy | ±0.002 pH / ±0.03% FS (mV) |
| Temperature Compensation | Automatic (ATC), –5.0 to 135.0 °C |
| Calibration | Up to 6-point automatic calibration with auto-buffer recognition (GB, DIN, NIST, and 22 additional standard buffer sets) |
| Data Storage | 1000 measurement records with timestamp, electrode ID, calibration history, and user log |
| Compliance | GLP-compliant data management, audit trail support, 21 CFR Part 11–ready software configuration (when used with Leici LabManager Pro v3.2+) |
| Connectivity | RS-232, USB host/device, optional auto-sampler interface |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | PHSJ-6L |
| Instrument Type | Benchtop |
| Parameter Types | Multi-parameter |
| Measurement Accuracy | 0.001 pH / ±0.002 pH |
| Measurement Range | (−2.000 to 20.000) pH |
| Resolution | 0.001 pH |
| Temperature Range | (−10.0 to 135.0) °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C (electronic unit) |
| Calibration Standards Supported | GB, DIN, NIST, USA, MERK, JIS |
| Protection Rating | IP54 |
| Channels | 4 modular slots (expandable to 4 pH modules) |
| Data Storage Capacity | 1000 pH measurements, 100 calibration records, 1000 standard verification logs |
| Interface | RS-232, USB, optional barcode scanner & autosampler integration |
| Compliance | GLP-compliant |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Portable |
| Parameter Types | Multi-parameter (pH, ORP, mV, Temperature) |
| pH Measurement Range | –2.00 to 20.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.02 pH |
| Calibration | Automatic recognition of GB, DIN, NIST, and other standard pH buffer solutions |
| Data Storage | 500 measurement records with GLP-compliant metadata |
| Environmental Rating | IP65 |
| Connectivity | RS232 printer port, USB interface for PC communication and firmware updates |
| Calibration Options | 1–5 point pH calibration, 1-point ORP calibration |
| Measurement Modes | Continuous, equilibrium-based, and programmable timed (interval or continuous timing) |
| User Management | Configurable user ID and sample ID fields |
| Display | Backlit LCD with graphical curve visualization |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 826 |
| Instrument Type | Portable |
| Parameter Type | Single-Parameter |
| Connectivity | IrDA (Infrared Data Association) |
| GLP Compliance | Yes |
| Data Storage Capacity | 200 measurements (with timestamp, date, and ID) |
| Power Supply | 4 × 1.5 V LR6 (AA) alkaline batteries |
| Battery Life | ≥500 hours |
| Ingress Protection Rating | IP67 |
| Electrode Compatibility | Primatrode series (e.g., 6.0228.020) |
| Calibration | Auto-buffer recognition, automatic temperature compensation (ATC), up to 3-point calibration |
| Software Integration | Metrodata VESUV 3.0, LIMS-compatible export |
| Operating Interface | Cursor-controlled text-guided menu |
| Enclosure Material | High-grade polymer with ergonomic, lab-grade finish |
| Optional Accessory | Integrated carry case with fold-out workstation surface |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 827 |
| Pricing | Available Upon Request |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Product Type | Imported |
| Model | 867 |
| Form Factor | Portable |
| Measurement Modes | pH, mV (Redox), Temperature, Ion Concentration (via ISE) |
| Calibration Points | 1–9-point |
| Interface | 2× USB, 4× MSB (Metrohm Serial Bus) |
| Regulatory Compliance | FDA 21 CFR Part 11–ready (when integrated with tiamo™ or TitraLab® software), GLP/GMP-compliant data handling |
| Electrode Support | Compatible with iTronde™ intelligent electrodes and conventional analog electrodes |
| System Integration | Standalone operation or fully embedded in Metrohm Titrando® titration systems and tiamo™ software platform |
| Configuration Options | 2.867.0010 (Basic pH Module), 2.867.0110 (pH Module with Touch Control), 2.867.0210 (pH Module with tiamo™ integration) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 913 |
| Instrument Type | Portable |
| Parameter Type | Single-Parameter (pH) |
| Measurement Accuracy | ±0.001 pH |
| IP Rating | IP67 |
| Display | Color LCD with Multilingual Support |
| Data Management | GLP-Compliant Logging, tiBase Integration, LIMS/Excel Export Capability |
| Electrode Interface | Standard BNC + Optional Smart Electrode Adapters |
| Operating Modes | Field, Laboratory, and Process-Support Configurations |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Product Type | Benchtop pH Meter |
| Model | 949 |
| Measurement Modes | pH, mV, ORP, Temperature |
| pH Range | −2.00 to 16.00 (resolution: 0.01 pH) |
| mV/ORP Range | −1000.0 to +1999.9 mV (resolution: 0.1 mV) |
| Temperature Range | −10.0 to +110.0 °C (resolution: 0.1 °C) |
| Calibration | Automatic buffer recognition (built-in IUPAC/NIST/USP/DIN buffer tables), up to 5-point calibration |
| Temperature Compensation | Automatic (ATC) and manual |
| Data Storage | Up to 1,000 measurement records with timestamp (date/time stamping) |
| Interface | RS232 serial port for printer or PC connection |
| Compliance | GLP-compliant reporting, audit-ready data logging, electrode calibration reminder |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Benchtop |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | −2.00 to 16.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Standards | Chinese JJG 119 / USP |
| Display | Large backlit LCD |
| Connectivity | RS232 and USB ports |
| Electrode Holder | Removable and stowable |
| Dimensions | 227 × 147 × 70 mm |
| Weight | 0.63 kg |
| Compliance | Designed for GLP-compliant workflows |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FiveEasyPlus™ |
| pH Range | −2.00 to 16.00 |
| pH Resolution/Accuracy | 0.01 / ±0.01 |
| Temperature Range | 0 to 105 °C |
| Temperature Resolution/Accuracy | 0.1 °C / ±0.3 °C |
| Temperature Compensation | Automatic (ATC) and Manual (MTC) |
| Data Storage | 200 measurement records + current calibration data |
| Buffer Sets | Predefined 4-point calibration sets |
| Interfaces | RS232 and USB |
| Electrode Compatibility | LE438, LE410, LE422, LE420, and other standard BNC-compatible pH electrodes |
| Display | Large backlit LCD with intuitive icon-based interface |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FE28 |
| Instrument Type | Benchtop |
| Parameter Types | pH and mV |
| Measurement Range | –2.00 to 16.00 pH |
| Resolution | 0.01 pH / 0.1 mV |
| Accuracy | ±0.01 pH |
| Calibration | Manual 1–3 point calibration with standard buffers (e.g., pH 4.01, 7.00, 10.01) |
| Connectivity | RS232 and USB interfaces |
| Display | Large backlit LCD with icon-based status indicators |
| Electrode Holder | Integrated retractable holder |
| Compliance | Designed in accordance with IEC 61010-1 for laboratory electrical safety |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | F2 |
| Instrument Type | Portable |
| IP Rating | IP67 |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| mV Range | −1999 to +1999 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±1 mV |
| Temperature Range | 0 °C to 100 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration | Up to 3-point with 4 preset buffer sets |
| Endpoint Detection | Auto/manual with audible and visual indication |
| Temperature Compensation | Automatic/manual |
| Electrode Interfaces | BNC, Cinch, NTC 30 kΩ |
| Data Storage | 200 measurement records |
| Display | 3.1-inch segmented LCD |
| Power Supply | 4 × AAA batteries (>200 h battery life) |
| Housing Material | ABS |
| Dimensions | 188 × 77 × 33 mm |
| Weight | 0.26 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FiveGo F2 |
| Instrument Type | Portable |
| Parameter Type | Single-parameter (pH/mV/°C) |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| mV Range | −1999 to +1999 mV |
| Temperature Range | 0.0–100.0 °C |
| Temperature Compensation | Automatic or Manual |
| Calibration | Up to 3-point calibration with 4 built-in buffer sets |
| Data Storage | 200 measurement records |
| Protection Rating | IP67 |
| Power Supply | Standard AA batteries |
| Compliance | International buffer standards (DIN, NIST, JIS, etc.) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | F3 |
| Instrument Type | Portable |
| Measurement Range | Conductivity: 0.00 µS/cm to 200 mS/cm |
| TDS | 0.01 mg/L to 200 g/L |
| Temperature | 0 °C to 100 °C |
| Resolution | Conductivity (auto-ranging), Temperature: 0.1 °C |
| Accuracy | Conductivity: ±0.5 %, Temperature: ±0.5 °C |
| Endpoint Detection | Auto/Manual with audible and visual indication |
| Temperature Compensation | Linear, 0.00–10.00 %/°C |
| Reference Temp | 20 °C or 25 °C |
| Calibration | 1-point, with 3 pre-stored standard solutions |
| Data Storage | 200 measurement records |
| Electrode Interface | LTW 7-pin |
| IP Rating | IP67 |
| Power Supply | 4 × AAA batteries (>200 h operation) |
| Display | 3.1-inch segment LCD |
| Housing Material | ABS |
| Dimensions/Weight | 188 × 77 × 33 mm / 0.26 kg |