Pipette
Filter
Showing 31–60 of 103 results
| Brand | Eppendorf |
|---|---|
| Model | Research® plus 0.5–5 mL |
| Type | Manual Air-Displacement Pipette |
| Channel Count | Single |
| Volume Range | 0.5–5 mL |
| Color Code | Purple |
| Compliance | ISO 8655-2, ISO 8655-5, GLP/GMP-ready documentation support |
| Ergonomic Design | PhysioCare Concept certified |
| Brand | ESEN |
|---|---|
| Origin | Zhejiang, China |
| Model | ADR-60 |
| Material | ETFE/FEP/PFA/PP |
| Sterilization | Autoclavable (121°C, 20 min) & UV-compatible |
| Certifications | ISO 9001:2015, ISO 13485:2016, CE, ISO/IEC 17025 compliant |
| Valve Type | Spring-free recirculating valve |
| Dispensing Range | Adjustable via dual-scale graduated cylinder (precise volume setting) |
| Rotational Design | 360° swivel nozzle |
| Filling Tube | Telescopic (170–300 mm), chemically resistant |
| Sealing System | Wiper-sealed piston with integrated cleaning interface |
| Safety Feature | Lockable recirculation switch to prevent sample loss and reagent waste |
| Brand | FOUR E'S SCIENTIFIC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model Range | Preci2 / Preci10 / Preci20 / Preci50 / Preci100 / Preci200 / Preci1K / Preci5K / Preci10K |
| Pipette Type | Manual Single-Channel Adjustable Volume Pipette |
| Volume Range | 0.1 µL – 10 mL |
| Maximum Capacity | 10 mL |
| Accuracy (Max System Error) | ±0.60% (varies by model |
| Precision (Max Random Error) | ≤0.20% (model-dependent) |
| Calibration Standard | ISO 8655 compliant |
| Tip Compatibility | Universal fit for standard conical polypropylene tips (e.g., Gilson, Eppendorf, Rainin, Thermo Fisher) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Type | Fixed-Volume and Adjustable-Volume Single-Channel Pipette |
| Volume Range | 5–1000 µL (10 models: 5, 10, 20, 25, 50, 100, 200, 250, 500, 1000 µL) |
| Accuracy | ±1% of nominal volume |
| Precision | ≤0.5% CV |
| Sterilization | Fully autoclavable (121 °C, 20 min, 1 bar) |
| Calibration Compliance | ISO 8655-6 |
| Tip Ejector | Integrated ergonomic push-button |
| Piston Coating | Diamond-Like Carbon (DLC) |
| Grip Options | Three interchangeable ergonomic grips (soft-touch TPE, textured polymer, low-thermal-conductivity composite) |
| Volume Display | Large, bottom-aligned digital scale with high-contrast markings |
| Locking Mechanism | Mechanical volume lock |
| Chemical Resistance | Resistant to UV, alcohols, chlorinated solvents, and common lab acids/bases |
| Maintenance | Tool-free disassembly for cleaning and recalibration |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Product Type | Manual Multichannel Pipette |
| Channels | 12 |
| Volume Range | 0.5–10 µL |
| Maximum Volume | 10 µL |
| Accuracy | ±0.2 µL or ±2% (whichever is greater) |
| Sterilization | Full-unit autoclavable (121 °C, 20 min) |
| Tip Cone Material | DLC-coated (Diamond-Like Carbon) stainless steel |
| Ergonomic Grip Options | Three interchangeable grip modules (soft-touch polymer, textured rubber, contoured silicone) |
| Volume Adjustment | Single-hand rotary dial with lockable setting |
| Display | Large, parallax-free mechanical volume readout |
| Thermal Isolation | Air-gap insulated handle and shaft |
| Serviceability | Tool-free piston assembly disassembly for cleaning and calibration |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | IKA Pette multi 12 x 10–100 µL |
| Instrument Type | Multichannel Pipette |
| Automation Level | Manual |
| Number of Channels | 12 |
| Volume Range | 10–100 µL |
| Maximum Volume | 100 µL |
| Accuracy | ±0.8 µL or ±0.8 % (whichever is greater) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | IKA Pette Multi 12 × 20–200 µL |
| Pipette Type | Multichannel Manual Pipette |
| Number of Channels | 12 |
| Volume Range | 20–200 µL |
| Maximum Volume | 200 µL |
| Accuracy | ±1.6 µL or ±0.8 % (at nominal volume) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Instrument |
| Model | IKA Pette Multi 8 × 10–100 µL |
| Pipette Type | Multichannel Manual Pipette |
| Channel Count | 8 |
| Volume Range | 10–100 µL |
| Maximum Volume | 100 µL |
| Accuracy | ±0.8 µL or ±0.8% (whichever is greater) |
| Sterilization | Full-unit autoclavable (121 °C, 20 min) |
| Tip Cone Coating | Diamond-Like Carbon (DLC) |
| Ergonomic Grip Options | Three interchangeable grip modules (soft-touch thermoplastic elastomer, textured polymer, low-profile rigid polymer) |
| Calibration | Tool-free adjustment |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | IKA Pette Multi 8 x 0.5–10 µL |
| Instrument Type | Multichannel Pipette |
| Automation Level | Manual |
| Number of Channels | 8 |
| Volume Range | 0.5–10 µL |
| Maximum Volume | 10 µL |
| Accuracy | ±0.2 µL or ±2% (whichever is greater) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Instrument |
| Model | IKA Pette Multi 8 x 20–200 µL |
| Instrument Type | Multichannel Pipette |
| Automation Level | Manual |
| Number of Channels | 8 |
| Volume Range | 20–200 µL |
| Maximum Volume | 200 µL |
| Accuracy | ±1.6 µL or ±0.8 % (at 200 µL), per ISO 8655-2 |
| Calibration Compliance | ISO 8655, ISO/IEC 17025-accredited calibration procedures available |
| Sterilization | Full autoclave-compatible (121 °C, 20 min, saturated steam) |
| Tip Cone Coating | Diamond-Like Carbon (DLC) |
| Ergonomic Grip Options | Three interchangeable grip modules (soft-touch elastomer, contoured rigid, low-profile) |
| Volume Adjustment | Single-hand rotary dial with tactile feedback and volume lock |
| Display | Large, parallax-free mechanical volume readout |
| Thermal Isolation | Air-gap insulated handle and shaft to minimize heat transfer from hand |
| Serviceability | Tool-free disassembly of piston assembly |
| Robotic Calibration System | IKA “Pit” & “Patty” automated calibration platforms (ISO/IEC 17025 traceable) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Type | Imported |
| Model | PETTE vario (Adjustable-Volume) / PETTE fix (Fixed-Volume) |
| Instrument Type | Single-Channel Manual Pipette |
| Volume Range | 0.1 µL – 10 mL |
| Accuracy | ±1% (per ISO 8655-2) |
| Sterilization | Fully Autoclavable (121 °C, 20 min) |
| Compliance | ISO 8655-1 to -6, GLP/GMP-ready |
| Dimensions | 30 × 254 × 63 mm |
| Weight | 89 g |
| Operating Environment | 5–40 °C, ≤90% RH |
| Brand | Innoteg |
|---|---|
| Origin | Germany |
| Model | Pett Fix |
| Type | Single-Channel Fixed-Volume Pipette |
| Maximum Volume | 1000 µL |
| Sterilization | Full-Assembly Autoclavable (121°C, 20 min) |
| Tip Compatibility | Standard Conical Tips (ISO 8655-compliant) |
| Operating Temperature Range | 15–30°C |
| Relative Humidity | 30–70% RH (non-condensing) |
| Calibration Interval | Recommended annually per ISO 8655-5 |
| Compliance | ISO 8655-1, -2, -5 |
| Brand | INNOTEG |
|---|---|
| Origin | Germany |
| Model | Pett Vario |
| Type | Manual Single-Channel Pipette |
| Maximum Volume | 10 mL |
| Sterilization | Full-Autoclavable (121°C, 20 min) |
| Tip Compatibility | Universal Conical Tips (ISO 8655-compliant) |
| Display | Large Backlit LCD |
| Ergonomic Options | Interchangeable Grip Inserts (Soft-Grip Polymer & Textured Rubber) |
| Piston & Cone Coating | Diamond-Like Carbon (DLC) |
| Volume Range Coverage | 0.1–2 µL to 1–10 mL (model-dependent) |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Acid6 |
| Instrument Type | Multichannel Pipettor |
| Automation Level | Motorized Pipettor |
| Number of Channels | 6 |
| Accuracy | ≤1% |
| Fluid Delivery Mechanism | High-Precision Peristaltic Pumps |
| Reagent Pathway Material | PFA Tubing |
| Control Interface | Wireless PAD with Graphical UI |
| Safety Features | Integrated Acid Fume Exhaust System, HEPA-Filtered Intake, Delayed Fan Shutdown, Real-Time Warning System |
| Mechanical Architecture | XYZ Three-Axis Robotic Arm |
| Ventilation Design | Built-in Illuminated Hood with Space-Saving Integrated Exhaust |
| Brand | Rainin |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model | E4 XLS+ |
| Instrument Type | Multichannel Pipette |
| Automation Level | Electronic Pipette |
| Channels | 8 |
| Volume Range | 1–300 µL |
| Maximum Capacity | 300 µL |
| Accuracy | ±1.0% at 0.2 µL, ±0.8% at 1.6 µL |
| Brand | Rainin |
|---|---|
| Origin | USA |
| Model | E4-10XLS+, E4-20XLS+, E4-1000XLS+ |
| Volume Range | 0.5–1000 µL |
| Max Capacity | 1000 µL |
| Accuracy | ±1% at 10 µL, ±0.8% at 8.0 µL |
| Display | Full-color high-resolution LCD |
| Control | Ergonomic joystick + rotary navigation dial |
| Calibration | Auto-zero reset after each dispense |
| Motor | 4,000-step precision stepper motor |
| Battery | Rechargeable Li-ion, >1,000 cycles, full-day operation |
| Compliance | GLP/GMP-ready, password-protected settings & service logs, tamper-proof audit trail |
| Tip Ejection Force | 0.6 kg (LTS system) |
| Software Integration | PureSpeed™ pre-installed, compatible with Rainin Liquid Handling Suite (LHS) |
| Brand | Rainin |
|---|---|
| Origin | USA |
| Model | LA6-300XLS / LA8-50XLS / LA8-1200XLS |
| Automation Level | Manual |
| Channels | 6 or 8 |
| Volume Range | 20 µL – 1,200 µL |
| Max Capacity | 1,200 µL |
| Accuracy | ±0.8 % at 50 µL, ±0.8 % at 300 µL, ±0.8 % at 1,200 µL |
| Channel Spacing Adjustment Range | 9–19 mm (6-channel), 9–14 mm (8-channel) |
| Tip System | LTS (Low Retention Standard) |
| Compliance | ISO 8655-2:2022, USP <1251>, GLP/GMP-ready documentation support |
| Brand | RAININ |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Liquidator™ 96 |
| Instrument Type | 96-Channel Manual Pipettor |
| Automation Level | Manual (Non-Motorized) |
| Channel Count | 96 |
| Volume Range | 0.5–20 µL and 5–200 µL |
| Maximum Capacity | 200 µL |
| Accuracy | ±1.0% at full scale |
| Precision (CV) | ≤1.5% (typical, per ISO 8655-6) |
| Power Requirement | None (mechanical actuation only) |
| Dimensions (W×D×H) | 14.5 × 6.5 × 12.0 cm |
| Weight | 320 g |
| Brand | RAININ |
|---|---|
| Origin | USA |
| Instrument Type | Single-Channel Manual Pipette |
| Volume Range Options | 0.1–2 µL to 1–10 mL |
| Technology | Magnetic-Assisted Piston Drive |
| Tip Ejection System | LTS (Low-Touch Tip Ejection) |
| Compliance | ISO 8655-2, ISO 8655-5, GLP/GMP-ready design |
| Brand | RAININ |
|---|---|
| Origin | USA |
| Model | Mettler Toledo Pipet-Lite XLS+ 8-Channel Pipettor |
| Automation Level | Manual |
| Channels | 8 |
| Volume Range | 0.5–300 µL |
| Max Capacity | 300 µL |
| Accuracy | ±4% at 1 µL, ±0.8% at 50 µL, ±0.8% at 300 µL |
| Brand | RAININ |
|---|---|
| Origin | USA |
| Model | Pipet-X |
| Type | Single-Channel Electronic Pipette Controller |
| Operating Volume Range | 0.1–100 mL |
| Power Source | Rechargeable NiMH Battery (up to 8 h continuous operation) |
| Dispensing Modes | Gravity-fed and Motor-driven |
| Filtration | Integrated 0.2 µm hydrophobic filter |
| Compatibility | Standard glass and plastic serological pipettes (Class A, ASTM E969, ISO 648) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | E4 XLS+ |
| Instrument Type | Multichannel Electronic Pipette |
| Automation Level | Motorized |
| Channel Count | Adjustable (1–12 channels via interchangeable tips) |
| Volume Range | 0.5–1250 µL (model-dependent configuration) |
| Accuracy | ±0.8%–±2.0% (volume-dependent, per ISO 8655) |
| Precision (CV) | ≤0.5%–≤1.5% (volume-dependent, per ISO 8655) |
| Display | Full-color 2.4″ TFT touchscreen |
| Control Interface | Precision tactile joystick |
| Onboard Memory | ≥20 user-defined protocols |
| Compliance | GLP/GMP-ready with audit trail, password-protected settings, calibration lock, service interval alerts |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | Pipette Management Software & Hardware Platform |
| Model | EasyDirect |
| Automation Level | Semi-Automated Asset Tracking System |
| Compliance | Designed for GLP/GMP environments |
| Data Integrity | Audit-trail enabled, 21 CFR Part 11 compliant (with optional electronic signature module) |
| Deployment | On-premise or networked server installation |
| Integration | Compatible with METTLER TOLEDO pipettes (e.g., E4–XLS+, Rainin XLS+), third-party pipettes via manual entry or CSV import |
| User Roles | Admin, Technician, Lab Manager, QA Auditor |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Pipet-Lite XLS+ |
| Type | Single-Channel Manual Pipette |
| Sterilization | Autoclavable (full liquid end, including seals and piston) |
| RFID Integration | Yes, for GLP/GMP-compliant service and calibration traceability |
| Ergonomic Design | Low-force plunger activation, optimized grip geometry, glove-compatible volume lock |
| Tip Ejection | Reinforced high-density polymer ejector arm with one-step removal for cleaning |
| Compliance | Designed to support ISO 8655, ASTM E1154, and FDA 21 CFR Part 11–aligned laboratory documentation workflows |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | E4 XLS+ |
| Channel Configurations | 1-, 6-, 8-, and 12-channel |
| Volume Range | 0.5–10 µL, 1–10 µL, 2–20 µL, 5–50 µL, 10–100 µL, 20–200 µL, 20–300 µL, 100–1000 µL, 100–1200 µL, 200–2000 µL, 500–5000 µL, 1–10 mL, 2–20 mL |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Pipet-Lite XLS+ |
| Volume Range | 0.1–20 mL (multiple fixed-volume variants) |
| Sterilization | Autoclavable (121°C, 20 min) |
| Tip Compatibility | LTS (Low-Torque Seal) and universal conical tips |
| Ergonomic Design | Integrated finger hooks, thumb cushion, internal dampening mechanism |
| Compliance | ISO 8655 compliant |
| RFID | Embedded for asset tracking |
| Channel Options | 1-, 6-, 8-, and 12-channel |
| Adjustable Spacing | 9–14 mm (8-channel), 9–19 mm (6-channel) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | Pipet-One / LTS / XLS |
| Type | Manual Single-Channel Pipettes |
| Compliance | ISO 8655, GLP/GMP-ready |
| Tip Compatibility | LTS (Low-Torque Seal) and Universal Conical |
| Calibration Support | MCP Calibration Workstation (ISO 8655-compliant) |
| Ergonomics | Optimized grip geometry, reduced tip ejection force (<15 N), adjustable volume lock |
| Brand | RAININ |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | Single-Channel / Multi-Channel / Classic / Electronic / Manual |
| Pricing | Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | Pre-sterilized, Recyclable Tip Rack System |
| Material Composition | Primarily PETE (Polyethylene Terephthalate) |
| Sterilization | Gamma-irradiated, ISO 11137 compliant |
| Environmental Certification | 100% recyclable per ISO 14021 |
| Packaging Efficiency | 50% less plastic vs. conventional tip racks |
| Compressibility | High — post-use volume reduction >60% in waste stream |
| Regulatory Compliance | Meets EU Directive 2002/96/EC (WEEE) and EN 13432 for recoverability |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet Air |
| Volume Range Options | 0.1–2 µL (Gray), 0.5–10 µL (Pink), 2–20 µL (Beige), 10–100 µL (Orange), 20–200 µL (Yellow), 100–1000 µL (Blue), 500–5000 µL (Green), 1000–10000 µL (White) |
| Increment Resolution | 0.002–10 µL (model-dependent) |
| Operating Principle | Air-displacement positive displacement hybrid mechanism with low-force plunger actuation |
