Pipette
Filter
Showing 61–90 of 103 results
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet FII & VII |
| Type | Manual Single-Channel Adjustable-Volume Pipette |
| Volume Range | 10–1000 µL |
| Accuracy | ±0.5% to ±1.2% (varies by volume) |
| Coefficient of Variation (CV) | ≤0.2% to ≤0.6% (volume-dependent) |
| Tip Compatibility | BMT2-series and F-series sterile filtered tips (e.g., BMT2-SG, FSGRB, BMT2-LE, FLERB) |
| Operating Principle | Air-displacement positive displacement (FII: fixed-volume |
| VII | triple presettable volumes) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | ACCUPENSER JR |
| Instrument Type | Manual Adjustable Bottle-top Dispenser |
| Automation Level | Manual |
| Volume Range Options | 0.2–10 mL (AJ-1), 0.4–20 mL (AJ-2), 1–50 mL (AJ-5), 2–100 mL (AJ-10) |
| Minimum Increment | 0.05 mL (AJ-1), 0.1 mL (AJ-2 & AJ-5), 0.25 mL (AJ-10) |
| Coefficient of Variation (CV) | ≤0.1% |
| Bottle Compatibility | Standard 500 mL and 1 L reagent bottles (neck dimensions identical) |
| Bottle Dimensions (W × H, mm) | 75 × 210 (165), 100 × 210 (165), 146 × 210 (165) — values in parentheses indicate collapsed height when vernier head is folded |
| Materials in Contact with Liquids | Chemically resistant polymers |
| Sterilization | Autoclavable at 121°C for 20 minutes |
| Compliance | Designed to support GLP-compliant workflows |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Custom-Made Pipettes |
| Instrument Type | Single-Channel Manual Pipette |
| Automation Level | Manual |
| Channel Count | Single |
| Volume Range | Custom-Defined (Typically 0.1–10,000 µL) |
| Accuracy & Precision | Compliant with ISO 8655 (per customer-specified calibration range) |
| Regulatory Compliance | Designed to support GLP/GMP workflows and FDA 21 CFR Part 11–aligned documentation protocols |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL2100DG |
| Type | Manual Multi-Channel Continuous Dispenser |
| Dispensing Range Options | 0.2–1.0 mL (00-21DG-1), 0.4–2.0 mL (00-21DG-2), 1.0–5.0 mL (00-21DG-5), 2.0–10.0 mL (00-21DG-10) |
| Minimum Increment | 0.01–0.10 mL depending on model |
| Display Resolution | 0.01 mL (DG-1/DG-2), 0.02 mL (DG-5), 0.10 mL (DG-10) |
| Fluid Contact Materials | PTFE, Tygon® tubing, polypropylene, Pyrex® glass, ceramic, platinum-iridium alloy |
| Housing | Impact-resistant polymer shell protecting internal glass and piston components |
| Ergonomics | Single-hand operation, lightweight design (<300 g) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL3100 |
| Pipette Type | Manual Multi-Channel Pipette |
| Volume Range Options | 0.2–1.0 mL, 0.4–2.0 mL, 1.0–5.0 mL, 2.0–10.0 mL |
| Minimum Increment | 0.1 mL (for 0.2–1.0 & 0.4–2.0 mL ranges), 0.5 mL (for 1.0–5.0 & 2.0–10.0 mL ranges) |
| Accuracy | ±1.0% |
| Coefficient of Variation (CV) | ≤1.0% |
| Tip Compatibility | Nichiryo Standard Clear Tips (00-MPT-1, 00-MPT-2, 00-BMT2-X, 00-BMT2-Z) |
| Piston Material | PTFE-Coated Stainless Steel |
| Tip Packaging | 1000 or 2000 per pack |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL5100 |
| Pipette Type | Single-Channel Manual Pipette |
| Adjustable Volume Range | 15–25 mL and 30–50 mL (via interchangeable volume adjustment tubes) |
| Accuracy | ±1.0% |
| Coefficient of Variation (CV) | ≤1.0% |
| Compatible Tip Type | Nichiryo TL50 Series (e.g., 00-51TL50) |
| Tip Packaging | 50 pcs per pack |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL8100 |
| Type | Motorized Multi-Step Electronic Dispenser |
| Sample Volume Range | 1 µL – 5 mL (configurable via 7 interchangeable syringe barrels) |
| Accuracy | ±0.8% to ±2.5% (volume-dependent) |
| Precision (CV) | ≤0.3% to ≤4.0% (volume-dependent) |
| Max. Dispensing Cycles per Fill | 10–58 (barrel-dependent) |
| Sterilization | Autoclavable at 121 °C for 20 min (all barrels except 3.0 mL and 60 mL) |
| Syringe Tip Length | 50 mm |
| Materials | PP (standard), PE (N3 and Z barrels) |
| Drive Mechanism | Pulse-driven positive displacement |
| Compliance | Designed for GLP-compliant liquid handling workflows |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL8800 |
| Instrument Type | Multi-Channel Manual Continuous Dispenser |
| Number of Channels | 8 |
| Operating Range | 10–100 µL (6 preset volumes: 10, 20, 25, 40, 50, 100 µL) |
| Accuracy | ±2.0% (at specified volumes) |
| Coefficient of Variation (CV) | ≤1.2% |
| Syringe Options | A (520 µL), B (1300 µL) |
| Max. Sequential Dispensing Cycles | 50 (at 10 µL), 25 (at 20/25 µL), 12 (at 40/50/100 µL) |
| Dimensions (with syringes installed) | 285 × 82 × 23 mm |
| Sterilization Compatibility | Autoclavable at 121°C for 20 min |
| Actuation | Manual lever-driven continuous dispensing |
| Brand | AS ONE (Nichiryo) |
|---|---|
| Origin | Japan |
| Manufacturer | Nichiryo Co., Ltd. |
| Model | 00-NSTP (equivalent to AS ONE catalog no. 2-5001-01) |
| Dispensing Range | 1–5000 µL |
| Dispense Increment | 1 µL |
| Drive Type | Motorized (Electric) |
| Channel Configuration | Single-Channel |
| Compliance | CE-marked, ISO 8655-compliant design principles |
| Calibration | Factory-calibrated per ISO 8655-6 |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | NPLO2 |
| Pipette Type | Manual Single-Channel |
| Volume Range | 0.5 µL – 50 mL (via interchangeable syringe barrels) |
| Accuracy | ±0.3% to ±5% (volume-dependent) |
| Precision (CV) | <0.2% to <8.0% (volume-dependent) |
| Sterilizable Options | Yes (selected syringe barrels) |
| Compatible Tips | BMT-UT tips (NS-V), NS-ASP adapters (NS-Y/Z), Eppendorf 4780-compatible syringes |
| Syringe Material | Polypropylene (barrel), Polyethylene (plunger) |
| Max Sequential Dispensing Cycles | 48 |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet ECO |
| Pipette Type | Single-channel Manual Pipette |
| Volume Range | 20 µL – 10 mL |
| Maximum Capacity | 10 mL |
| Accuracy | ±3.0% to ±6.0% |
| Precision (CV) | ≤3.0% to ≤6.0% |
| Tip Compatibility | Nichiryo Glass Tips (S, L, X, Z series) |
| Operating Principle | Air-displacement with ceramic piston and PTFE-coated tip cone |
| Sealing | Dual O-ring tip ejection mechanism |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | EX II MULTI |
| Pipette Type | Manual Multi-Channel Pipette |
| Channels | 8 or 12 |
| Volume Range Options | 0.5–10 µL (V), 5–100 µL (S), 20–200 µL (L), 30–300 µL (K) |
| Minimum Increment | 0.01 µL (V), 0.1 µL (S), 0.2 µL (L), 1 µL (K) |
| Sterilization | Full-unit autoclavable at 121°C for 20 min |
| Tip Compatibility | BMT2-UT/UTWR/UTWRB, FUT/FUTRB, BMT2-SG/SGR/SGRB, FSE/FSERB, FAG/FAGRB, BMT2-K/KR/KRB |
| Material | UV-resistant polymer housing |
| Weight Reduction | ~30% vs. previous generation |
| Ergonomic Design | Rotatable 360° plunger knob, reduced plunger force, serviceable modular construction |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet EX II |
| Type | Manual Single-Channel Pipette |
| Volume Range | 0.1–10,000 µL |
| Maximum Capacity | 10 mL |
| Accuracy | ±2.0% |
| Sterilization | Autoclavable at 121°C for 20 min |
| Tip Ejection | Non-contact, plastic ejector mechanism |
| Sealing Material | PTFE in air-tight components |
| Piston Material | Ceramic (for ≥200 µL models) |
| Filter Tip Compatibility | Integrated filter sleeve (≥1000 µL models) |
| Volume Adjustment | Digital dial with lockable knob |
| Minimum Increment | 0.002–10 µL (model-dependent) |
| Tip Compatibility | BMT2-series tips (UT, SS, SG, LE, X, Z) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet EX Plus II |
| Pipette Type | Manual Single-Channel |
| Volume Range | 0.1–10,000 µL |
| Maximum Capacity | 10 mL |
| Accuracy | ±2.0% |
| Tip Compatibility | BMT2-series (UT, SS, SE, L, X, Z) |
| Sterilization | Autoclavable (121°C, 20 min) & UV-Capable |
| Calibration | In-lab adjustable via integrated locking dial |
| Piston Material | Ceramic (≥100 µL), Fluoropolymer-coated stainless steel (≤10 µL) |
| O-rings | FKM (fluoroelastomer) |
| Spring | Corrosion-resistant alloy |
| Chemical Resistance | Verified against strong acids, bases, ketones, esters, aldehydes, and inorganic/organic solvents |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Pipette Mate NEO |
| Power Source | Rechargeable Lithium-Ion Battery (Charging Time: 4 h |
| Input Voltage | 100–240 V, 50/60 Hz, 0.2 A |
| Filter | Hydrophobic PTFE, 20 mm × 0.2 µm |
| Compatible Pipettes | 1–100 mL glass or plastic serological pipettes |
| Sterilization | Autoclavable at 121 °C for 20 min (liquid-contact components only) |
| Weight | 167 g |
| Certifications | CE, RoHS |
| Operating Environment | Compatible with laminar flow hoods and UV sterilization workflows |
| Ergonomics | Integrated speed control dial, vertical stand-alone design (no support rack required) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Type | Sterilizable Disposable Pipette Tips |
| Packaging Options | Bulk (1000 pcs) and Rack (96-well or 50-well formats, sterilized or non-sterilized) |
| Volume Range | 0.1–10 µL, 0.5–10 µL, 2–200 µL, 50–300 µL, 100–1000 µL, 1000–5000 µL, 1000–10000 µL |
| Material | High-purity polypropylene (PP) |
| Sterilization | Autoclavable at 121 °C for 20 minutes |
| DNase/RNase-Free | Yes (except X and Z series) |
| UV-Compatible | Yes |
| Brand | RAININ |
|---|---|
| Origin | USA |
| Model | BenchSmart™ 96 |
| Instrument Type | Multi-Channel Pipettor |
| Automation Level | Semi-Automatic |
| Channel Configuration | 96-channel (with optional 384-well compatibility) |
| Volume Range | 0.5–1000 µL |
| Maximum Capacity | 1000 µL |
| Accuracy | ±1% |
| Interchangeable Pipetting Heads | Three (0.5–20 µL, 20–200 µL, 100–1000 µL) |
| Brand | Rainin |
|---|---|
| Origin | USA |
| Model | E-Man |
| Type | Electronic Hybrid Pipette with Real-time Piston Sensing |
| Volume Range Options | 0.1–2 µL, 0.5–10 µL, 2–20 µL, 10–100 µL, 20–200 µL, 20–300 µL, 100–1000 µL, 200–2000 µL |
| Display | High-contrast LCD showing real-time piston position and 4-digit volume setting |
| Compliance | Designed for GLP/GMP environments with audit-ready maintenance tracking |
| Ergonomics | LTS (Low-Torque Seal) tip ejection system and ISO 8655-compliant ergonomic design |
| Accessories | CR-7 rotating stand, HU-M3 magnetic hook, HU-S3 adhesive hook, HU-A3 adapter |
| Brand | Rainin |
|---|---|
| Origin | USA |
| Model | E4 XLS |
| Instrument Type | Multichannel Pipette |
| Automation Level | Electronic Pipette |
| Channel Count | 6 or 8 |
| Volume Range | 5–1200 µL |
| Maximum Capacity | 1200 µL |
| Accuracy | ±0.8% at 1.2 µL and 9.6 µL |
| Compliance | GLP/GMP-ready, password-protected settings and service alerts, tamper-proof usage logs |
| Brand | Rainin |
|---|---|
| Origin | USA |
| Model | E4 XLS+ |
| Instrument Type | Multi-Channel Pipette |
| Automation Level | Electric |
| Channel Count | 8 or 12 |
| Volume Range | 0.01–1200 µL |
| Accuracy (at 0.04 µL) | ±4.0 % |
| Compliance | GLP/GMP-ready, FDA 21 CFR Part 11–compatible audit trail support |
| Tip System | LTS (Low Retention Standard) |
| Display | Full-color high-resolution LCD |
| Navigation | Rotary encoder + ergonomic joystick |
| Battery | Rechargeable Li-ion, >10,000 pipetting cycles per charge |
| Onboard Memory | Stores ≥20 user-defined protocols |
| Calibration | Auto-zero reset after each pipetting cycle |
| Ergonomics | Ambidextrous design, glove-compatible, tip ejection force ≤0.6 kg (with LTS tips) |
| Brand | Rainin |
|---|---|
| Origin | Switzerland |
| Model | SE4-10XLS+ |
| Volume Range | 0.5–10 µL |
| Type | Single-Channel Electronic Pipette |
| Drive Mechanism | Stepper Motor (4,000-step resolution) |
| Display | Full-color graphical LCD |
| Control Interface | Joystick + rotary navigation dial |
| Calibration | Auto-zeroing at end of each pipetting cycle |
| GLP/GMP Compliance | Password-protected settings, tamper-proof service logs, audit trail-capable |
| Power | Rechargeable lithium-ion battery (≥1 day runtime, >1,000 charge cycles) |
| Ergonomics | Ambidextrous design, LTS (Low-Torque Seal) tip ejection system (ejection force ≤0.6 kg), integrated finger hooks, glove-compatible operation |
| Software Integration | Preloaded PureSpeed™ mode for biomolecule purification (proteins, oligonucleotides) |
| Onboard Memory | Multiple user-defined protocols stored locally |
| Brand | RAININ |
|---|---|
| Origin | USA |
| Model | LA6 / LA8 |
| Volume Range Options | EA6-300 (20–300 µL, 6-channel), EA6-1200 (100–1200 µL, 6-channel), EA8-50 (5–50 µL, 8-channel), EA8-300 (20–300 µL, 8-channel), EA8-1200 (100–1200 µL, 8-channel) |
| Power | Rechargeable Lithium-ion Battery (Model 6107-040) |
| Accessories | CR-7 Rotating Stand, HU-M3 Magnetic Hook, HU-S3 Adhesive Hook, HU-A3 Hook Adapter, E3-WPS Wall-Mounted Charging Power Supply, E3-RCS Rapid Charging Station |
| Brand | Rainin |
|---|---|
| Origin | USA |
| Model | E3/SE3 |
| Volume Range Options | 1–10 µL to 100–1200 µL (8-, 12-, 16-, and 24-channel configurations) |
| Drive Mechanism | Microprocessor-Controlled Stepper Motor |
| Tip Ejection System | LTS (Low-Torque Tip System) |
| Power Source | Rechargeable Lithium-Ion Battery |
| Compliance | ISO 8655-2, ISO 8655-5, GLP/GMP-ready data integrity support |
| Brand | Rainin |
|---|---|
| Origin | USA |
| Model | EDP3 |
| Volume Range Options | 0.5–10 µL, 2–20 µL, 10–100 µL, 20–200 µL, 20–300 µL, 100–1000 µL, 200–2000 µL, 500–5000 µL, 1–10 mL, 2–20 mL |
| Tip System | LTS (Low Retention Technology) |
| Power Source | Rechargeable Lithium-ion Battery |
| Compliance | ISO 8655 compliant, GLP/GMP-ready with audit trail capability (via Liquidator™ Software) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Line | Rainin® |
| Tip Compatibility | LTS (Low-Torque Seal) and XLS+ platforms |
| Sterilization | Autoclavable (121°C, 20 min) |
| Material | Medical-grade polypropylene (PP) for tips |
| Volume Range | 10 µL, 250 µL, 1000 µL |
| Packaging Formats | Green-Pak™ single-box refills (96 tips), SpaceSaver™ stackable refills (8 or 10 trays per pack), TerraRack™ 100% recyclable racks, Bulk bags (1,000 tips/bag, 10 bags/box = 10,000 tips), StableStak™ high-density stacking system (768 tips per 10×96 configuration), StableRack™ dual-96 format (35% less plastic vs. two standard racks) |
| Regulatory Compliance | ISO 8573-1 Class 0 certified air purity, DNase/RNase-free, non-pyrogenic, tested per ASTM D257 (surface resistivity), USP <85> endotoxin testing ≤0.03 EU/mL |
| Brand | RAININ |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NanoRep |
| Instrument Type | Single-Channel Electronic Pipette |
| Automation Level | Motorized |
| Channels | 1 |
| Volume Range | 0.1 µL – 50,000 µL (100 nL – 50 mL) |
| Maximum Capacity | 50 mL |
| Dispensing Steps | Down to 1/10,000 of tip capacity |
| Max Dispense Cycles per Aspiration | 1,000 |
| Minimum Dispense Interval | 0.5 s |
| Piston Design | External Piston (Positive Displacement) |
| Compatible Tips | Three interchangeable dispensing tips covering full range |
| Compliance | ISO 8655-compliant design, supports GLP/GMP documentation workflows |
| Brand | Rainin |
|---|---|
| Origin | USA |
| Model | Pipet-Lite |
| Volume Range Options | 1–10 µL to 100–1200 µL (8- and 12-channel) |
| Tip Ejection System | LiteTouch™ (LTSTM) |
| Tip Interface | LTS Cylindrical |
| Compliance | ISO 8655–2, ISO 8655–6, GLP/GMP-ready documentation support |
| Brand | Rainin |
|---|---|
| Origin | USA |
| Model | Pipet-Lite XLS |
| Type | RFID-Enabled Manual Single-Channel Pipette |
| Compliance | ISO 8655 Compliant |
| Regulatory Support | FDA 21 CFR Part 11 Ready (via LabX Direct Pipette-Scan™) |
| Ergonomic Certification | Certified by independent biomechanical assessment per ISO 10075-3 |
| Brand | Rainin |
|---|---|
| Origin | USA |
| Model | Pipet-Lite XLS+ |
| Type | Manual Single-Channel Pipette |
| Volume Range | 0.1 µL to 20 mL |
| Maximum Capacity | 20 mL |
| Accuracy | ±0.6% |
| Tip Ejection Force | 0.6 kg |
| Brand | Rainin |
|---|---|
| Origin | USA |
| Model | L-10XLS+, L-20XLS+, L-100XLS+ |
| Type | Single-Channel Manual Pipette |
| Channels | 1 |
| Volume Range | 0.5–2000 µL |
| Maximum Capacity | 2000 µL |
| Accuracy | ±1% at 20 µL, ±0.8% at 200 µL |
| Sterilization | Fully autoclavable (liquid end, tip ejector, and sleeve) |
| Compliance | GLP/GMP-ready with embedded RFID for calibration traceability |
| Ergonomics | Magnetic Assist™ piston mechanism, LTS™ LiteTouch System, low-force plunger actuation, glove-friendly volume adjustment |