Polymerase Chain Reaction Instrument
Filter
Showing 61–90 of 90 results
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | CFX Opus Deepwell |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Capacity | 96-well format |
| Heating Rate | 2.5°C/sec |
| Temperature Accuracy | ±0.2°C |
| Well-to-Well Temperature Uniformity | ±0.4°C |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | CFX384 Touch |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 384-well format |
| Maximum Heating Rate | 2.5 °C/s (adjustable from 0.1 to 2.5 °C/s) |
| Temperature Accuracy | ±0.2 °C at 90 °C setpoint |
| Well-to-Well Temperature Uniformity | ±0.4 °C within 10 seconds after reaching 90 °C |
| Excitation Range | 5 LEDs (400–650 nm) |
| Emission Detection Range | 5 Photodiodes (515–690 nm) |
| Supported Applications | Absolute Quantification, Gene Expression Analysis, SNP Genotyping, HRM (High-Resolution Melting), Multiplex Detection (up to 4 targets per well) |
| Software | CFX Maestro Secure Edition (21 CFR Part 11 compliant, audit trail, user access control) |
| Thermal Block | Integrated C1000 Touch thermal cycler engine |
| Gradient PCR | Yes, 30–100 °C range, max ΔT = 24 °C |
| Dimensions (W × D × H) | 33 × 45.7 × 35.6 cm |
| Weight | 21 kg (47 lb) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | CFX96 Touch |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well (0.2 mL tubes) |
| Max Heating Rate | 5 °C/s (adjustable from 0.1 to 5 °C/s) |
| Temperature Accuracy | ±0.2 °C at 90 °C setpoint |
| Well-to-Well Temperature Uniformity | ±0.4 °C within 10 seconds after reaching 90 °C |
| Excitation Range | 6 LEDs (450–684 nm) |
| Emission Detection Range | 6 Photodiodes (515–730 nm) |
| Gradient PCR | Yes, 30–100 °C, max ΔT = 24 °C |
| High-Resolution Melting (HRM) Support | Yes |
| Interface | USB |
| Dimensions (W×D×H) | 33 × 45.7 × 35.6 cm |
| Weight | 21 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PTC Tempo |
| Instrument Type | Standard Thermal Cycler |
| Sample Capacity | 96-well, 384-well, 48/48 dual-block |
| Heating Rate | 5°C/s |
| Temperature Accuracy | ±0.2°C (measured at 90°C) |
| Well-to-Well Temperature Uniformity | ±0.4°C (measured at 90°C) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | QX Continuum™ |
| Instrument Type | Digital PCR System |
| Sample Throughput | 96-well format |
| Certified Performance | NMI-traceable reference material validation |
| Droplet Generation | >20,000 droplets per 16 µL sample |
| Multiplexing Capacity | Up to 4 targets per well |
| Thermal Zones | Up to 8 independent temperature zones per plate |
| Software | QX Insight Analysis Software |
| Regulatory Status | For Research Use Only (RUO), not for clinical diagnostic use |
| Compliance | Designed to support GLP/GMP-aligned data integrity practices |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | QX ONE |
| Instrument Type | Digital PCR System |
| Sample Throughput | 32–480 wells per run |
| Heating Rate | 2.5 °C/s |
| Temperature Accuracy | ±0.2 °C (at 90 °C) |
| Well-to-Well Temperature Uniformity | ±0.4 °C (at 90 °C) |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | QX200 |
| Instrument Type | Digital PCR System |
| Sample Throughput | 96-well format |
| Heating Rate | 0.1–5.0°C/s (typical setting: 2.0°C/s) |
| Temperature Accuracy | ±0.2°C (at 90°C) |
| Well-to-Well Temperature Uniformity | ±0.4°C (at 90°C) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Instrument Type | Digital PCR System |
| Model | QX600 |
| Detection Channels | 6-color (FAM, HEX, Cy5, Cy5.5, ROX, ATTO 590) |
| Multiplex Capacity | up to 12-plex per well (CNV applications) |
| Limit of Detection | <0.1% mutant allele frequency |
| Quantification Precision | ±10% CV |
| Regulatory Compliance | FDA 21 CFR Part 11 (Advanced Software), GLP/GMP-ready audit trail |
| Platform Compatibility | Fully compatible with Manual DG and AutoDG droplet generators |
| Assay Support | TaqMan probe-based and EvaGreen dye-based ddPCR assays |
| Certification | Traceable calibration verified by Australia’s National Measurement Institute (NMI) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | QX700™ E |
| Instrument Type | Digital PCR System |
| Sample Throughput | 48-well |
| Detection Channels | 7-color multiplexing |
| Sample Input Volume | 5 µL per reaction |
| Droplets per Sample | ≥17,000 |
| Automation Level | Fully integrated, walk-away operation |
| Run Time for 48 Samples | 2.5 hours |
| Chip Format | Single disposable cartridge accommodating up to 48 samples |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | QX700™ HT |
| Instrument Type | Digital PCR System |
| Sample Throughput | 384-well format |
| Detection Channels | 7-color multiplexing |
| Sample Input Volume | 5 µL |
| Effective Droplets per Sample | ≥17,000 |
| Automation Level | Fully integrated workflow (droplet generation, thermal cycling, and fluorescence reading) |
| Max. Chip Capacity per Run | 2 microfluidic chips |
| Time to Result | ≤2.5 hours for 96 samples |
| Time to Result | ≤8 hours for 384 samples |
| On-demand Loading | Yes, with independent thermal control per 16-well chip segment |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | QX700™ S |
| Instrument Type | Digital PCR System |
| Sample Throughput | 192-well format |
| Detection Channels | 7-color simultaneous detection |
| Sample Input Volume | 5 µL |
| Effective Droplet Partitions per Sample | ≥17,000 |
| Automation Level | Fully automated end-to-end workflow |
| Chip Format | 16-well disposable cartridge (scalable to 192 samples per run) |
| Run Time for 192 Samples | 8 hours |
| Run Time for 96 Samples | 5 hours |
| Thermal Cycling | Independent programmable thermal cycling per well |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | S1000™ 384 Well |
| Instrument Type | Gradient PCR System |
| Sample Capacity | 384-well plate |
| Max Heating Rate | 2.5°C/s |
| Temperature Accuracy | ±0.2°C at 90°C |
| Inter-well Temperature Uniformity | ±0.4°C within 10 s at 90°C |
| Gradient Range | 1–24°C across 12 columns |
| Gradient Accuracy (last column) | ±0.2°C |
| Operating Temperature Range | 0–100°C |
| Input Power | 400 W max |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | S1000™ 96 Deep Well |
| Sample Capacity | 96 × 0.2 mL tubes or 1 × 96-well plate |
| Max Ramp Rate | 2.5°C/s |
| Temperature Accuracy | ±0.2°C at 90°C |
| Well-to-Well Uniformity | ±0.4°C within 10 s at 90°C |
| Gradient Range | 30–100°C, Span 1–24°C |
| Gradient Accuracy (Last Column) | ±0.2°C |
| Gradient Uniformity (Within Column) | ±0.4°C within 10 s |
| Input Power | 400 W max |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| PCR Licensing | Yes |
| Onboard Memory | >1,000 protocols |
| USB Ports | 4 × Type-A, 1 × Type-B |
| Display | LCD |
| Heating Technology | Instant-On Peltier |
| Thermal Block Design | Patented honeycomb architecture |
| Programmable Interface | Text-based and semi-graphical editing |
| Heat Lid | Adjustable pressure, auto-lift compatible |
| Safety | Password-protected protocol folders |
| PC Connectivity | Windows XP or later via C1000 Touch controller (up to 3 S1000 units per C1000) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | S1000™ 96-Well |
| Sample Capacity | 96 × 0.2 mL tubes or 1 × 96-well plate |
| Max Heating/Cooling Rate | 5°C/sec |
| Temperature Accuracy | ±0.2°C at 90°C |
| Well-to-Well Temperature Uniformity | ±0.4°C within 10 sec at 90°C |
| Gradient Range | 30–100°C, Span 1–24°C |
| Gradient Accuracy (Last Column) | ±0.2°C |
| Column Uniformity | ±0.4°C within 10 sec per column at target temperature |
| Input Power | 400 W max |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | S1000™ Dual 48 Well |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Throughput | 2 × 48 wells (0.2 mL tubes or plates) |
| Max Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.2 °C at 90 °C |
| Well-to-Well Temperature Uniformity | ±0.4 °C within 10 s at 90 °C |
| Gradient Range | 30–100 °C, Span 1–24 °C |
| Temperature Range | 0–100 °C |
| Input Power | 400 W max |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | T100™ |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well (0.2 mL plates or tubes) |
| Max Heating/Cooling Rate | 4 °C/s |
| Temperature Accuracy | ±0.2 °C (at 90 °C) |
| Well-to-Well Uniformity | ±0.4 °C (at 90 °C) |
| Gradient Range | 30–100 °C |
| Gradient Span | 1–25 °C |
| Operating Temperature Range | 4–100 °C |
| Onboard Memory | 500 protocols |
| Display | 5.7" high-resolution color touchscreen |
| Interface | 1 × USB port |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | FQD-96A |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well |
| Max Heating Rate | 5.0°C/s |
| Temperature Accuracy | ≤ ±0.1°C |
| Well-to-Well Temperature Uniformity | ≤ ±0.3°C |
| Excitation Source | Long-Life LED |
| Detection Mode | Bottom-Reading Optical System (Patented) |
| Thermal Control | Multi-Point PID with Peltier-based Semiconductor Modules (Ferrotec Custom) |
| Power Input | AC 100–240 V, 50/60 Hz, 650 W |
| Dimensions (L×W×H) | 410 × 386 × 352 mm |
| Net Weight | 28 kg |
| Interfaces | RS232, USB, Bluetooth |
| OS Compatibility | Windows 7 / 8.1 / 10 |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | CFX96 Deep Well Dx |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well format |
| Heating Rate | 2.5 °C/sec |
| Temperature Accuracy | ±0.2 °C |
| Well-to-Well Temperature Uniformity | ±0.4 °C |
| Excitation Channels | 5 + 1 (including reference channel) |
| Detection Method | Scanning-based fluorescence acquisition |
| Max Reaction Volume | 125 µL |
| LED Light Source Lifetime | >50,000 hours |
| Compliance | MIQE-guided software, FDA 21 CFR Part 11–ready audit trail, ISO 13485-aligned IVD design |
| Brand | Genemeter |
|---|---|
| Model | DiOne |
| Instrument Type | Digital PCR System |
| Sample Throughput | 4–32 samples per run (integrated droplet generation, thermal cycling, and fluorescence readout) |
| Heating Rate | ≥8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Origin | Sichuan, China |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC-manufactured) |
| Brand | HUXI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | HUXI Scientific Instrument Co., Ltd. |
| Model | HX-PCR200 |
| Sample Capacity | Dual 48×0.2 mL (individual tubes or 8-tube strips) |
| Max Heating Rate | 6 °C/s |
| Temperature Accuracy | ≤ ±0.2 °C (block), ≤ ±0.3 °C (gradient) |
| Block Uniformity | ≤ ±0.25 °C |
| Gradient Range | 30–105 °C |
| Gradient Span | 0.1–30 °C |
| Gradient Uniformity | ≤ ±0.3 °C |
| Thermal Lid Temperature | 30–110 °C |
| Temperature Resolution | 0.1 °C |
| Ramp Rate Adjustment | 0.1–6 °C/s |
| Max Cycles | 99 |
| Max Steps per Program | 30 |
| Program Storage | >10,000 protocols |
| Touchdown & Long PCR Modes | Yes |
| Operating System | Embedded Linux |
| Display | 8-inch capacitive touchscreen (1024×768) |
| Power Input | AC 100–240 V, 50/60 Hz |
| Max Power | 800 W |
| Dimensions (W×D×H) | 260×390×230 mm |
| Net Weight | 9 kg |
| Brand | KURABO |
|---|---|
| Origin | Japan |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | GF-Q150 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 10-well |
| Heating Rate | 8°C/sec |
| Temperature Accuracy | ±0.5°C |
| Inter-Well Temperature Uniformity | ±0.5°C |
| Reaction Volume | 10 µL |
| Operating Temperature Range (RT-PCR) | 35–65°C |
| PCR Temperature Range | 20–99°C (1.0°C increment) |
| Display | 4-line LCD |
| Built-in Protocols | 12 |
| Power Input | AC 100–230 V, 50/60 Hz (DC 12 V input) |
| Dimensions (W×L×H) | 20 × 20 × 12.5 cm |
| Weight | ≤3.2 kg |
| Data Analysis Modes | Real-time amplification curves, qualitative positive/negative calling, melting curve analysis, ΔCT and ΔΔCT-based gene expression quantification |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | AriaDNA-4 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 48-well microchip format |
| Heating Rate | 7 °C/s |
| Cooling Rate | 7 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Inter-well Temperature Uniformity | <0.3 °C |
| Sample Volume per Reaction | 1–2 µL |
| Minimum Detectable Target | 1–5 DNA/RNA copies per microreactor |
| Thermal Range | 0–99 °C |
| Detection Channels | 4 (FAM/SYBR Green, HEX/VIC, ROX, Cy5) |
| Power Consumption | 100 W |
| Dimensions | 185 × 260 × 285 mm |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | AriaDNA® |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 48-well or 32-well microchip format |
| Heating Rate | 12 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Inter-well Temperature Uniformity | ±0.1 °C |
| Cooling Rate | 10 °C/s |
| Minimum Detectable DNA Copies per Microreactor | 1–5 |
| Total Reaction Time for 45 Cycles | ≤20 min |
| Microreactors per Chip | 16–48 |
| Reagent Volume per Reaction | 0.5–1 µL (2× PCR mix) |
| Integrated Dried-Down Reagents | Yes |
| Detection Channels | Channel 1 (FAM, SYBR Green) |
| Control Interface | External PC with Dedicated PCR Analysis Software & Database |
| Power Consumption | 80 W |
| Dimensions (W×D×H) | 250 × 300 × 190 mm |
| Weight | 5 kg |
| Brand | LY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Gradient PCR Thermal Cycler |
| Heating Rate | 5°C/s |
| Cooling Rate | 4.5°C/s |
| Temperature Accuracy | ±0.2°C |
| Block Uniformity | ±0.25°C |
| Gradient Range | 30–105°C |
| Gradient Span | 0.1–42°C |
| Block Temperature Range | 0–105°C |
| Heat Lid Range | 30–110°C |
| Sample Capacity | 96 × 0.2 mL tubes (semi-skirted/unskirted), 12 × 8-tube strips, 8 × 12-tube strips, or individual tubes (20–23 mm height) |
| Step Time Range | 1 s – 59 min 59 s (0 = infinite) |
| Display | 5-inch high-resolution color touchscreen |
| Operating System | Industrial-grade embedded OS |
| Data Export | USB flash drive interface |
| Brand | Aperbio |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Digital PCR System |
| Model | NaicaEL |
| Compliance | CE-IVD, ISO 13485 certified manufacturing |
| Software | Crystal Miner™ v3.2 with FDA 21 CFR Part 11–compliant audit trail and electronic signature support |
| Detection Chemistry | TaqMan®-compatible hydrolysis probes & intercalating dyes |
| Partitioning Technology | Capillary-based microfluidic crystal formation (PRISM PCR™) |
| Brand | Aperbio |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 96-well format |
| Heating Rate | 8.5 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Thermal Control Technology | Marlow Semiconductor-based Peltier Modules |
| Optical Detection Architecture | Integrated Waveguide-Based Fluorescence Detection |
| Software Platform | CqMAN Quantitative Analysis Suite (Multi-language: English & Chinese) |
| Consumable Compatibility | Automated pressure-assisted sealing for both 0.1 mL and 0.2 mL tube formats |
| Automation Interface | RS-232/USB/Ethernet |
| Brand | PCRmax |
|---|---|
| Origin | United Kingdom |
| Model | AC-1 |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well (0.2 mL) or 384-well module (field-replaceable) |
| Max Heating/Cooling Rate | 3.4 °C/s |
| Temperature Accuracy | ±0.25 °C |
| Inter-well Temperature Uniformity | ±0.3 °C |
| Temperature Range | 4–100 °C |
| Gradient Range | 10–100 °C |
| Gradient Span | 1–29 °C |
| Gradient Channels | 12 independent temperature zones |
| Heat Lid Temperature | 35–115 °C (adjustable, manually pressure-controlled) |
| Heat Lid Uniformity | ±5 °C |
| Heat Lid Preheating Time | <2 min |
| Display | 7" 1080P full-color LCD touchscreen |
| OS | Embedded Android-based firmware |
| Onboard Program Storage | ≥1,000 protocols |
| USB Expansion Support | Yes (USB-A & USB-B) |
| Power Consumption (30-cycle run) | 0.3 kWh |
| Dimensions (W×D×H) | 200 × 260 × 430 mm |
| Rated Power | 425 W |
| Noise Level | <50 dB(A) |
| Brand | PCRmax |
|---|---|
| Origin | United Kingdom |
| Model | AC-2 |
| Sample Capacity | Two independent blocks (configurable as two 96-well, two 384-well, or mixed 96/384 modules) |
| Max Heating Rate | 3.4 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Block Uniformity | ±0.3 °C |
| Temperature Range | 4–100 °C |
| Gradient Range | 10–100 °C |
| Gradient Span | 1–29 °C |
| Gradient Steps | 12 distinct temperatures with identical hold times |
| Thermal Lid | Adjustable manual pressure, 35–115 °C (or off), uniformity ±5 °C, preheat time <2 min |
| Cooling Method | Peltier-based semiconductor |
| Programmable Cycles | Up to 99 |
| Onboard Storage | ≥1000 protocols |
| Interface | 1× USB-A, 1× USB-B |
| Power | 900 W |
| Dimensions (W×D×H) | 470 × 535 × 330 mm |
| Noise Level | <50 dB (per module) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | ASA-9600 |
| Price Range | USD 14,000–42,000 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 96-well format |
| Heating Rate | Avg. ≥1.5 °C/s, Max. ≥2.5 °C/s |
| Temperature Accuracy | ≤±0.5 °C |
| Well-to-Well Temperature Uniformity | ≤±1.0 °C |
| Cooling Rate | Avg. ≥1.5 °C/s, Max. ≥2.0 °C/s |
| Temperature Range | 4–99 °C |
| Lid Temperature | 104 °C |
| Excitation Wavelength Range | 380–780 nm |
| Emission Detection Channels | Up to 5 excitation + 5 emission filters |
| Fluorescence Detection Reproducibility (CV) | ≤3% |
| Inter-channel Crosstalk | Target-channel threshold not exceeded by adjacent channel signal |
| Linearity (R²) | ≥0.990 for fluorescence, ≥0.980 for sample concentration |
| Dynamic Range | 10 orders of magnitude |
| Brand | Tianhe (Shandong Tianhe Instrument Co., Ltd.) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | TH-YB416 |
| Price | USD 6,700 (approx. based on ¥48,000 at 1 USD ≈ ¥7.15) |
| Sample Capacity | 8 × 0.2 mL tubes |
| Reaction Volume | 5–120 µL |
| Temperature Range | 4–99 °C |
| Max Heating/Cooling Rate | ≥2 °C/s |
| Temperature Uniformity | ≤±0.2 °C |
| Temperature Accuracy | ≤±0.1 °C |
| Excitation Wavelength Range | 400–700 nm |
| Detection Channels | 1 channel (FAM/SYBR Green I) standard |
| Optical Detection | Imported photodetector array |
| Thermal Module | High-performance Peltier (Marlow) with PT1000 sensor and resistive edge compensation |
| Thermal Gradient | None |
| Real-time Data Acquisition | 3-second full-plate read |
| Display | 7-inch HD capacitive touchscreen |
| Noise Level | <45 dB |
| Dimensions (W×L×H) | 290 × 308 × 130 mm |
| Net Weight | ~3 kg |