| Brand | INFICON |
|---|---|
| Origin | Germany |
| Model | IC6 Thin Film Deposition Controller |
| Measurement Principle | Quartz Crystal Microbalance (QCM) with ModeLock Frequency Detection |
| Resolution | 0.00433 Å/s @ 100 ms sampling |
| Frequency Stability | ±0.0035 Hz |
| Max Simultaneous Sources | 6 |
| Layer Capacity | 50 processes × 200 layers = 10,000 total layers |
| Sensor Inputs | Up to 8 QCM sensors (averaged or independent) |
| Display | Color TFT LCD |
| I/O | 28 digital inputs, 24 relay outputs, 14 TTL outputs, 6 standard DACs + 6 optional DACs |
| Logic Engine | 100 programmable logic statements |
| Data Storage | Internal logging, screenshot capture, recipe storage |
| Communication | RS-232/485, optional Ethernet |
| Compliance | RoHS-compliant |
| Software Support | IC6 Configuration Editor (LabVIEW®-based, Windows®) |
| Brand | Shanghai Xiande |
|---|---|
| Origin | Shanghai, China |
| Model | GMVC-3000pro |
| Control Range | 1–800 mmHg (Torr), 1–1066 hPa (mbar), 0–106.6 kPa, 0 to –0.01 MPa |
| Pressure Type | Negative (Vacuum) |
| Display | Digital Touchscreen (5.5″ Color LCD) |
| Ultimate Vacuum | 8 mbar |
| Max Pumping Speed | 20 or 30 L/min |
| Interface | Quick-Connect Ø10 mm |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 130 W |
| Standby Power | 3 W |
| Noise Level | ≤55 dB(A) |
| Operating Temperature | 5–40 °C |
| IP Rating | IP20 |
| Dimensions (L×W×H) | 185 × 310 × 310 mm |
| Weight | 13 kg |
| Optional Steam Temperature Monitoring | –20 to 200 °C |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | RPM10 |
| Sensor Technology | Thermal Mass Flow-Based Differential Pressure Sensing |
| Compliance | ANSI/ASHRAE/ASHE Standard 170-2008, FGI Guidelines 2010, CDC Environmental Infection Control Guidelines, USP <797> |
| Alarm Types | Visual (LED status ring + touchscreen icon) and Audible (adjustable threshold & delay) |
| Operating Modes | Isolation (AII/PE), Neutral/Non-Isolation |
| Interface | Local touch-screen programming, BACnet MS/TP or Modbus RTU (optional), physical mode toggle switch |
| Security | Password-protected configuration access |
| Display | Color LCD with intuitive status visualization (e.g., green = nominal, amber = warning, red = alarm) |
| Enclosure Rating | IP42 |
| Power | 24 VDC (PoE-compatible option available) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8682-ST |
| Control Channels | Up to 5 independent duct systems |
| Pressure Sensing | Differential pressure transducer input |
| Output Interfaces | Analog (4–20 mA / 0–10 V), Relay alarms, MODBUS RTU (RS-485) |
| Power Supply | 120 VAC to 24 VAC transformer included (25 VA) |
| Enclosure | NEMA 1 indoor-rated |
| Compliance | CE, RoHS |
| Software Integration | Compatible with BMS via open MODBUS protocol |
| Alarm Logic | Adjustable delay to suppress transient false alarms |
| Local Interface | Backlit keypad and LCD display with password-protected configuration |
| Brand | VACUUBRAND® |
|---|---|
| Origin | Germany |
| Model | VACUU·SELECT |
| Control Range | Down to 10⁻³ mbar |
| Control Methods | Two-Point (Solenoid Valve) & VARIO® Variable-Speed Drive |
| Display | Capacitive Touchscreen Interface |
| Language Support | 14 Languages |
| Material Compatibility | Chemically Resistant (PTFE, FKM, PP, Borosilicate Glass) |
| Compliance | CE, RoHS, ISO 9001 Certified |
| Application Scope | Laboratory Vacuum Networks, Rotary Evaporation, Freeze Drying, Schlenk Line Operations, Chemical Distillation |
| Brand | York Instruments |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | CPC4000 |
| Operating Principle | Electronic Pressure Control |
| Display | Digital |
| Control Stability | < 0.005 % FS |
| Control Speed | < 10 s |
| Accuracy | 0.02 % of reading (50–100 % FS), 0.02 % of half-scale (0–50 % FS) |
| Pressure Range | –0.1 to 21 MPa |
| Uncertainty Budget | Expanded uncertainty (k = 2) per ISO/IEC 17025, incorporating sensor intrinsic performance, reference standard uncertainty, long-term drift, thermal effects, zero-shift beyond auto-compensation range, and environmental influences |